Which single-use supplies does a Canadian eye clinic reorder every month for lacrimal irrigation?

Six rolls of paper medical tape arranged on a white reflective surface

Which single-use supplies does a Canadian eye clinic reorder every month for lacrimal irrigation?

Syringing a tear duct takes about ninety seconds, uses five or six consumables, and answers a question no other test answers: whether the drainage system is open from punctum to nose. Because it is quick, the supplies are usually reordered from memory rather than from a count, which is how a clinic ends up short of cannulas on a list day.

Which single-use supplies does one irrigation use?

The set is small and almost entirely single use, because the parts that enter the punctal opening cannot be cleaned and re-used.

Item Per irrigation Single use Note
Lacrimal cannula 1 yes straight or curved, blunt tip, sized to the punctum
Syringe 1 yes 2 to 5 mL, luer tip, saline filled
Saline 2-5 mL yes single-use vial or a fresh draw
Fluorescein strip 1, when tested yes for patency and for dye disappearance testing
Cotton-tipped applicator 2 yes to hold the lid and to blot
Gauze 2-4 pieces yes to catch the return at the nostril

How many does a month of clinic lists consume?

The monthly figure is irrigations per week multiplied by 4.3, with a margin for the second attempt that a blocked duct frequently needs.

Irrigations per week Cannulas a month Fluorescein strips Saline, single-use vials
10 43 30 43
20 86 60 86
40 172 120 172

Stack of sterile gauze sponges with 12-Ply, Sterile and 200 pcs printed on the pack

A clinic that stocks to the average rather than to the peak will run out during a blockage-heavy week, because the repeat attempt uses a second cannula rather than the same one.

Which cannula is not interchangeable?

A blunt fill cannula sold for aesthetic injectables is not a lacrimal cannula. The fill version is made to transfer fluid from a vial through a septum, with a different length and tip geometry, and it is not intended for insertion at the punctum. The two products can sit in similar packaging in the same drawer, which is why the intended use on the label, not the look of the hub, should decide what goes on the trolley.

The same logic applies to the syringe. A 2 to 5 mL luer-tip syringe gives the control needed to irrigate gently; a larger barrel delivers a bolus that a closed system will not accept, and the reflex is to push harder rather than to stop.

Which standard should the order line cite?

Two families come up. Biological evaluation follows ISO 10993-1, and the published edition is 2025, following the withdrawal of the 2018 text on 18 November 2025; a specification that still cites 2018 is citing a withdrawn edition. Labelling follows ISO 15223-1:2021, which defines the symbols on the pack, including the struck-through numeral two that marks a device as single use.

Six rolls of paper medical tape arranged on a white reflective surface

Neither standard tells a clinic how many cannulas to buy. What they do is fix the paperwork: the device the clinic receives has to carry the symbols and the intended use it was ordered against, and a substitution that changes the intended use is a change to the clinical procedure, not a supply swap.

What has to be recorded per irrigation?

A procedure note that stands up to review carries the eye, the indication, the anaesthetic used, whether the system was patent, what came back and whether it was clear or purulent, the cannula and syringe used, and the lot if a recall is ever raised. That is a short list, and writing it at the time takes less effort than reconstructing it a month later.

What does the clinic stock, and what does it order in?

The cannula, the syringe and the saline vial are order-in lines, and this supplier does not stock any of the three. What it does stock covers the rest of the trolley: sterile gauze sponges, 12-ply, 200 per pack for catching the return, hypoallergenic paper tape, 1 inch by 10 yards for holding a pad in place after probing, and nitrile examination gloves, 1,000 per case for the procedure itself.

The useful split is between the lines that scale with the number of procedures and the lines that scale with the number of patients. Cannulas and syringes follow procedures; gauze and tape follow patient contacts, and a clinic that moves from ten to twenty irrigations a week will double the first group while barely moving the second.

Eye and surgical clinics buy on different rhythms, and the clinic consumables page groups the lines that sit outside the procedure-specific set.

Ordering for a clinic or a surgical centre? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines held for institutional buyers. Reselling? become a distributor.

References

  1. ISO 10993-1:2025 — Biological evaluation of medical devices, Part 1: Evaluation and testing within a risk management process (checked 7 November 2026)
  2. ISO 15223-1:2021 — Symbols to be used with information supplied by the manufacturer, Part 1: General requirements (checked 7 November 2026)

Printable companion: the free log and checklist library includes a procedure consumable sheet that can be printed and kept with the clinic’s own records.

Turning a clinic list into an order? The clinic supply and cost planner converts weekly procedures into monthly consumable quantities.

Related Reading

Frequently Asked Questions

What is used for one lacrimal irrigation?

A topical anaesthetic drop, a 2 to 5 mL syringe with a lacrimal cannula, a few millilitres of saline, a fluorescein strip if patency is being assessed, cotton-tipped applicators, and gauze to catch the return. Everything that touches the punctum is single use.

Is a blunt fill cannula the same as a lacrimal cannula?

No. A blunt fill cannula is made for transferring fluid from a vial, with a different length and tip, and it is not intended for insertion at the punctum. Buying on looks is the usual error, because the two sit in similar packaging.

How many cannulas does a clinic need a month?

Multiply irrigations per week by 4.3. At twenty a week that is about eighty-six cannulas, plus a margin for repeat syringing on the same patient, which a blocked duct often needs.

Which version of the biocompatibility standard should an order cite?

ISO 10993-1:2025 is the published edition, following the withdrawal of the 2018 text on 18 November 2025. A specification that still cites the 2018 edition is citing a withdrawn text and should be refreshed.

Last updated: November 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).

Vous travaillez déjà avec des cliniques ? Devenez représentant régional.