Where to Buy Pipette Tips for Diagnostic Laboratories in the GTA
Which pipette tips does a diagnostic laboratory in the GTA actually order?
Most GTA diagnostic laboratories run two tip families at once: a 200 µL racked tip for chemistry, serology and amplification set-up, and a 1000 µL tip for larger volumes and viscous samples. The smaller racked tip is the line that gets reordered most often, because a technologist touches it on every bench, several times a shift.
The MTC Bio 200 and 300 microlitre pipette tips, sterile racked, with gel-loading tips is that line in our catalogue, so it is worth knowing what the words in its name commit the supplier to.
Filtered and non-filtered tips are not interchangeable: a filtered tip keeps the pipettor barrel clean during amplification work and with volatile solvents, while a non-filtered tip suits routine chemistry and serology.
What does "sterile, racked" buy you?
Three separate commitments, usually sold as one phrase. Sterile means the lot was processed to a sterility assurance level of 10⁻⁶, which is the same target medical devices are held to. Racked means the tips arrive in a holder that fits the pipettor stand and can go into the cabinet without being handled one by one.

The third commitment is the one buyers forget: certified free of DNase, RNase and endotoxin. It is a different test from sterility, matters for molecular work, and belongs on the certificate.
How do you check a tip supplier before the first order?
Ask for the certificate for the lot you will receive, not one from last year. Then ask which pipettor models the tip is listed for. Tip fit is part of the measuring system under ISO 8655-2, so a loose fit shows up as a volume error in QC rather than a visible defect.
For Ontario laboratories, consumable control is part of the inspection conversation: laboratories and specimen collection centres licensed under Regulation 682 are asked how materials are received, stored and traced, and a tip lot with no recorded number is a gap that is easy to avoid.
What should arrive with a case of tips?

The lot number printed on the case, the sterility certificate for sterile lines, an expiry date where one applies, intact packaging and a named contact for a nonconformance. Photograph the case label before the racks go into the drawer; six months later that photograph is the only link between a result and a lot.
| Tip format | Volume range | Filter | Typical GTA bench use | Reorder signal |
|---|---|---|---|---|
| 200 µL standard, racked, sterile | 10 to 200 µL | No | chemistry and serology | empty rack at the bench |
| 200 µL filtered, racked, sterile | 10 to 200 µL | Yes | amplification set-up | weekly rack count |
| 1000 µL wide-bore | 100 to 1000 µL | No | serum and viscous reagents | first empty box |
| Gel-loading, flat tip | under 200 µL | No | polyacrylamide gels | flat-tip stock at half |
Where does GTA delivery time come from?
For a Toronto, Mississauga, Markham, Vaughan or Brampton laboratory the case clears the same warehouse as the rest of the order, so lead time is set by stock, not distance. Stock items ship in 2–3 business days.
Order it with the rest of the bench consumables — serological pipettes and parafilm and graduated specimen cups — so one delivery covers the week and one lot record covers the run.
Laboratories in the GTA and across Ontario can see the wider range on our diagnostic laboratory supplies page.
Ordering for a laboratory group or a multi-site diagnostic network? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B ordering collection lists the lines stocked for institutional buyers. Reselling? become a distributor.
References
- ISO 8655-2:2022, Piston-operated volumetric apparatus, part 2: pipettes (checked 23 November 2026)
- Ontario Regulation 682, Laboratory and specimen collection centre licensing (checked 23 November 2026)
Printable companion: the receipt and lot tracking templates record lot numbers against the bench they were issued to, the question an inspection asks after a repeat failure.
Rather than recount racks by hand, the laboratory supply planner turns your weekly rack count into a reorder quantity and a case count.
Related Reading
- Which Pipette Tips Does a Canadian Research Laboratory Reorder Monthly?
- Pipette Calibration in Canada vs the US: Which Intervals and Records Apply?
- Why Serological Pipettes Over-Deliver: Blow-Out and Drainage
Frequently Asked Questions
Are sterile pipette tips required in a diagnostic laboratory?
Not by a single federal rule. Sterility is required when the workflow needs it, for example cell culture, microbiology media or molecular set-up, and your own procedure should say so.
What is the difference between filtered and non-filtered tips?
A filtered tip carries an aerosol barrier that keeps the pipettor barrel clean when you are working with amplification reagents or volatile solvents. Non-filtered tips are fine for routine chemistry and serology.
Can one tip lot be used across two instruments?
Only if the supplier lists both pipettor models as compatible. Tip fit is part of the measuring system under ISO 8655-2, so a loose fit shows up as a volume error rather than as a visible defect.
What should arrive with a case of tips?
The lot number on the case, the sterility certificate for sterile lines, the expiry date where one applies, intact packaging, and a named contact for a nonconformance.
Last updated: November 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).