Where can I buy Class 5 chemical integrators for steam sterilization in Canada?

CliniEco Class 5 steam chemical integrator, 100 per pack

Where can I buy Class 5 chemical integrators for steam sterilization in Canada?

CliniEco Medical supplies Class 5 steam chemical integrators from Toronto, Ontario, and ships across Canada. Orders leave stock within one business day. The ISO 11140-1 Type 5 integrator is $19.99 per 100-pack, $32.99 per 200-pack, and $159.92 for a case of ten 100-packs, so the order format moves with the number of packs a practice releases in a week.

Where can I buy Class 5 chemical integrators in Canada?

From CliniEco Medical in Toronto, in three formats that hold the same strip.

Order format Integrators Price
100-pack 100 $19.99
200-pack 200 $32.99
Case of ten 100-packs 1,000 $159.92

A practice releasing forty packs a day runs through a 100-pack in three working days, so the case is the working order and the 100-pack the top-up. Nothing about the strip changes between formats, which means a clinic can start at 100 and move to a case without re-qualifying the indicator.

CliniEco steam chemical integrator, Class 5, ISO 11140-1 Type 5, colour-change indicator

How does Class 5 differ from the other classes?

The class system in ISO 11140-1 sorts chemical indicators by how many critical parameters they respond to. A Class 1 tape shows the pack went through a cycle. A Class 4 indicator responds to two parameters. A Class 1 autoclave indicator tape on the outside of a pouch therefore cannot stand in for the integrator inside it, and the two are bought together rather than chosen between.

A Class 5 integrator is specified to respond to all critical parameters of the steam cycle and to perform like a biological indicator in its response range. ISO 17665:2024, the moist heat standard, is the process standard the cycle is validated against; the integrator is the per-pack evidence that the cycle behaved.

Which packs need an integrator, and which do not?

CliniEco Class 5 steam chemical integrator, 100 per pack

Every pack that carries an instrument set for patient use needs one, and that includes a single-instrument pouch, because the pouch is released as a pack. Where a clinic uses a process challenge device for a load, the device carries its own indicator and the load is released on that reading.

The decision a buyer actually faces is pack count, not policy. Count the packs released in a working week, add the packs from a heavy implant or surgical list, and the reorder level follows. Clinics with a written load-release rule usually run short about a third of the way through a case, which is the point to set a second case as a standing order.

What should a buyer verify before ordering?

Three checks. The pack label has to state the class and the ISO standard, since Type 5 and Type 6 indicators are sold side by side and are not interchangeable. The strip has to be readable against a printed reference rather than a colour memory. And the lot has to be traceable to the loads it was used on, which is the record the reprocessing standard asks a clinic to keep.

Ordering for several sites? Wholesale and multi-site ordering covers case pricing and purchase-order billing, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.

Not sure how the class rules apply to your own cycles? Ask a sterilization compliance specialist for a written answer that cites the standard behind each line.

References

  1. ISO 11140-1:2014, Chemical indicators, Part 1: general requirements and class definitions (checked 13 November 2026)
  2. CSA Z314:23, Canadian medical device reprocessing in all health care settings — standard record (checked 13 November 2026)
  3. ISO 17665:2024, Sterilization of health care products — moist heat (checked 13 November 2026)

Printable companion: the sterilization log sheet carries the integrator result for every pack, which is the line an inspection reads first.

Integrators are consumed pack by pack. The clinic supply planner converts packs per week into 100-packs per order.

Related Reading

Frequently Asked Questions

Where can I buy Class 5 chemical integrators for steam sterilization in Canada?

CliniEco Medical supplies them from Toronto, Ontario, and ships across Canada: $19.99 per 100-pack, $32.99 per 200-pack, or $159.92 for a case of ten 100-packs, with orders leaving stock within one business day.

What does a Class 5 integrator measure that a strip does not?

It responds to three parameters together, time, temperature and saturated steam, and reads as one pass or fail window. A Class 4 strip responds to two parameters, and a Class 1 tape responds only to the cycle.

Does a Class 5 integrator replace a biological indicator?

No. It is a chemical indicator inside the pack and it is read on release; the biological indicator remains the check on the process itself, and CSA Z314:23 keeps the two in separate roles.

How many integrators does a pack need?

One per pack, placed in the position that is hardest for steam to reach, and the pouch for a single instrument counts as a pack. Load release reads the integrator from each pack, not a sample.

How should integrators be stored and read?

Sealed, dry and out of direct heat, and read against the printed reference on the strip rather than from memory. A window that arrives at the boundary colour is a fail, not a pass.

Last updated: November 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).

Vous travaillez déjà avec des cliniques ? Devenez représentant régional.