Which Rapid Antigen Kits Should a Clinic Hold, and How Should They Be Stored?

Clear graduated specimen container with a white screw cap, marked in ounces and millilitres

Quick facts

  • Buy only what appears on the federal list of authorized testing devices: Health Canada publishes the testing devices it has authorized, and a kit that is not on that list is not a kit a Canadian clinic can rely on.
  • Storage temperature comes from the instructions for use, not from the shipping carton; a kit stored outside its stated range has no valid result even if the pouch is sealed.
  • Lot rotation is FIFO with a written lot log, because a kit whose component expiry differs from the carton date will otherwise be discarded unused or used too late.
  • A clinic running a respiratory season should size stock from visits per month, not from the case size the supplier ships.
  • External controls per new lot, as the instructions specify, are the only check that separates a bad kit from a bad swab.
  • The authorization list and the regulations cited were read on 2026-10-21.

Respiratory season turns rapid antigen kits from a minor line item into a stock decision with a shelf life. The questions that matter are narrow: which analytes the clinic actually needs, how many tests a month of visits will consume, whether the storage space holds the temperature the instructions require, and how lots are rotated so that nothing expires in a drawer. Each of those is answerable with a number, and none of them is answered by a supplier's case size. This article sets out the analyte mix, a stock-sizing table, the storage conditions that invalidate a result when they are missed, the lot and control record, and the regulatory difference between Canadian authorization and the American route. The specimen collection containers ordered alongside the kits are used as the working example, since a kit is only as good as the swab and the tube that reach the bench with it.

Which analytes belong in a clinic's season stock?

Start from the differential the clinic actually manages. A primary care office seeing febrile respiratory illness needs influenza A and B and SARS-CoV-2, because the three drive different decisions about antivirals, isolation and return to work. A paediatric practice may add a group A streptococcus test, which is a different device with a different specimen site, and should be stocked and logged as a separate line rather than counted into the respiratory total.

The second question is who reads the result. A kit whose instructions describe visual read at a stated window suits an office where the result is read by the person who ran it. A kit that requires an instrument ties the practice to that instrument and to its maintenance, which is a different purchase decision.

The third question is the specimen. A kit validated for nasopharyngeal swabs is not interchangeable with one validated for anterior nasal swabs, and the difference shows up in sensitivity rather than in convenience. Buy the swab the kit was validated with, and keep the pairing on the shelf label.

How much should a clinic hold for a season?

Size from visits, then add a buffer for the week when three people are off sick and the testing rate doubles. The table below is a planning grid: read the row that matches your monthly visit volume and adjust the test rate to the share of visits that actually present with respiratory symptoms.

Monthly visits Tests per 100 visits Tests per month Kits of 25 to hold Buffer
600 6 36 2 1 kit
1,200 6 72 3 1 kit
2,000 8 160 7 2 kits
3,000 8 240 10 3 kits
4,000 10 400 16 4 kits

The buffer exists because kits expire, and a practice that holds exactly its expected consumption will run out in the one week it cannot afford to. The buffer should be sized in weeks of cover, not in cases, so that it moves with the season rather than with the supplier's packaging.

Clear graduated specimen container with a white screw cap, marked in ounces and millilitres

What does storage actually require?

The instructions for use state a temperature range and usually a prohibition on freezing. Both matter more than they look. A kit held below its range can lose reagent activity, and a kit held above it can dry the conjugate or degrade the membrane; in either case the result is not a false negative that announces itself, it is a faint line that gets read as negative.

Three habits keep a stock inside its range. Store kits away from an exterior wall and away from a door that opens to the outdoors, because those two positions swing the most in a Canadian winter. Keep a thermometer in the storage cupboard and read it on a schedule rather than when something looks wrong. And bring a kit to room temperature before opening, as the instructions direct, rather than warming it on a radiator.

The desiccant in the pouch is part of the device. A pouch left open, or a kit stored in a humid room, takes up moisture and the migration on the strip changes. If a pouch has been open for any length of time, treat the test as invalid rather than as borderline.

How should lots be rotated and checked?

First in, first out, with the lot number written on the shelf edge and in the log. The reason is not tidiness: the expiry printed on the outer carton and the expiry on the individual foil pouch are not always the same date, and a practice that rotates by carton date will find the discrepancy only when a pouch is opened after its own date has passed.

Second, the external control run. The instructions for use state whether a positive and negative control is required with each new lot, with each shipment, or at another interval; follow that statement rather than a habit carried over from a previous supplier. A control that fails on a new lot is a lot that does not enter service, and the log line is what proves the decision was made before the first patient.

Third, a discrepancy routine. A result that does not fit the clinical picture is repeated with a fresh kit from a different lot where the instructions allow it, and the event is recorded with both lot numbers. That single practice is what turns a suspicious result into evidence about the kit rather than about the patient.

Pair of blue nitrile examination gloves photographed on a white background

What does the record have to show?

Four fields per lot: lot number, expiry, date received, date the control was run and its result. Four fields per storage check: date, location, minimum and maximum temperature seen, initials. Together they answer the two questions an inspection asks - was the kit in date, and was it in range - without requiring anyone to reconstruct a season from memory.

Keep the temperature log continuous rather than episodic. A min-max thermometer read weekly gives a range for the week and takes a minute; a reading taken only when someone remembers gives a number with no coverage. Where the cupboard shares space with vaccines or reagents, one log covering the shared space is enough if it names every product family stored there.

The record should also name the kit's authorized status. A line that says which authorization the kit was purchased under converts a purchasing decision into a document, and it is the line that survives a change of supplier.

What differs between Canada and the United States?

Canada authorizes testing devices through Health Canada and publishes the devices it has authorized, so a clinic's first check is a list rather than a class. The device also sits inside the Medical Devices Regulations, which is what makes the manufacturer's licence file the document that supports the sale.

The United States adds a second layer that Canada does not have: the laboratory's own certificate. A clinic running the test is a laboratory for CLIA purposes, and the category of test determines which certificate applies. 42 CFR 493.15 sets out the laboratories that perform only waived tests, which is the category most office-based rapid testing falls into.

Item Canada United States
Device authorization Health Canada authorization; authorized devices are listed publicly FDA clearance, approval or authorization
Operator requirement Provincial rules on who may perform the test CLIA certificate; waived tests under 42 CFR 493.15
Storage and stability Instructions for use Instructions for use, plus CLIA quality requirements
Lot documentation Practice record Required laboratory record
Where the list lives Federal list of authorized testing devices FDA device database

Kits, swabs, tubes and the containers that travel with them are usually one order. The wholesale programme handles case pricing and an account, and the distributor route is for resellers. The graduated specimen containers are the item most often added to the kit order, and the diagnostic laboratory range lists the rest.

Sources

  1. Health Canada - COVID-19 medical devices: testing devices (authorized device list, read 2026-10-21)
  2. Medical Devices Regulations, SOR/98-282 (Justice Laws)
  3. 42 CFR 493.15 - Laboratories performing waived tests (Cornell LII, read 2026-10-21)
  4. Health Canada - medical devices portal
  5. FDA product classification database
  6. openFDA device classification API
  7. Provincial guidance for cleaning, disinfection and sterilization in health care settings (Public Health Ontario, PDF)
  8. CDC guideline for disinfection and sterilization in healthcare facilities - summary of recommendations
  9. CCOHS - OSH Answers index
  10. ISO 15189:2022 - Medical laboratories, requirements for quality and competence (reagent and lot records)

The lot log is the document that answers the question, and a free printable log sheet already carries the four fields - lot, expiry, receipt, control - in the order an inspection asks for them.

For a clinic with more than one storage cupboard, the log generator prints a separate temperature sheet per location, which is the difference between a range and a guess.

If your province imposes an operator requirement that the kit instructions do not mention, ask a compliance specialist: the reply is a written answer specific to your equipment and province, with the regulation or standard it is based on cited.

Related reading

CliniEco Medical is a Canadian medical device importer with MDEL #35334. Nothing in this article is clinical advice for a specific patient, and no product in it is presented as a substitute for the instructions supplied with a device.

Frequently Asked Questions

How many rapid antigen kits should a clinic keep?

Size from monthly visits and the share that present with respiratory symptoms, then add one to four kits of buffer depending on volume. A clinic seeing 1,200 visits a month at six tests per hundred visits needs about 72 tests a month, which is three kits of 25 plus one spare.

Can kits be stored in a fridge?

Only if the instructions for use state a refrigerated range. Many respiratory antigen kits are labelled for room temperature and prohibit freezing; putting them in a fridge because it feels safer moves them outside their stated range and invalidates the result.

What if the carton expiry and the pouch expiry differ?

Rotate by the pouch, not the carton. When the two disagree, the earlier date controls, and the lot log should record both so the discrepancy is visible before a pouch is opened after its own date.

Do I need to run controls with every new lot?

Follow the instructions for use. They state whether a positive and negative control is required per lot, per shipment or at another interval, and that statement replaces any habit carried over from a previous supplier.

Is a rapid antigen kit a laboratory test in Canada?

The device needs Health Canada authorization, and whether the person running it needs a provincial laboratory licence depends on the province and the setting. The device question and the operator question are separate, and both have to be answered before the first patient.

What temperature record is enough?

A min-max thermometer in the storage space, read weekly, with the range and initials written down. That gives continuous coverage; a reading taken only when something looks wrong gives none.