How Do ISO 11948 Absorbency Ratings Translate Into a Brief Change Schedule in Canadian Long-Term Care?

Packaged disposable underpads and bed sheets stacked in a care facility storeroom

How Do ISO 11948 Absorbency Ratings Translate Into a Brief Change Schedule in Canadian Long-Term Care?

On a 32-resident unit, the personal care aide changes a brief roughly five times across a day and a night shift. That is 160 changes a day, close to 4,800 a month, and the product decision behind every one of them is usually made once a year by somebody reading a spec sheet in an office.

The spec sheet leads with a number in millilitres. The aide works with a resident, a lift, a wash basin and a limited amount of time. Between those two positions sits a translation problem: how the laboratory figure relates to the interval that actually keeps a resident dry, and what a facility should write into a care plan so the answer is consistent across three shifts.

Quick facts

  • ISO 11948-1:1996 gives a method for determining the absorption capacity of the absorbent core of a body-worn urine-absorbing aid, and it was confirmed in 2023 rather than replaced.
  • ISO 11948-2:1998, which addressed short-time liquid release under light incontinence and low pressure, was withdrawn in December 2003.
  • Capacity is a whole-product core test. Rewet under body weight, fit, leg-cuff seal and odour control are outside its scope.
  • Absorbent incontinence garments are regulated as medical devices in Canada, and the licensing obligations sit with the licence holder rather than the purchaser. CliniEco Medical is a licensed medical device establishment (MDEL #35334).
  • A par level built from residents multiplied by changes multiplied by days, plus a buffer, is more reliable than a par level copied from another unit.
  • Recording the product code on the change record is what makes a leakage complaint answerable three weeks later.

What does an absorbency rating actually measure?

The standard is narrow and honest about it. ISO 11948-1 sets out a whole-product method for the absorption capacity of the absorbent core, which means a defined quantity of test liquid is introduced and the retained volume is measured. It produces a figure that lets two products be compared on the same basis, and that is the whole of its claim.

It does not describe what happens when a resident lies on the product. Pressure on a saturated core pushes liquid back toward the skin, and the amount pushed back depends on the core construction, the distribution layer and how the product is positioned. It does not describe leg-cuff seal, which is a fit question. And it does not describe odour, which depends on how the core locks away liquid and on how long the product is worn.

That is why a facility comparing two briefs on the millilitre figure alone is comparing only part of the product. The figure is useful, but it belongs next to fit, backsheet breathability and how the product behaves on a resident who is turned at night.

How does a millilitre figure relate to a change interval?

The arithmetic is simple once the units are aligned. Capacity is a laboratory figure for the core. The volume a resident produces between changes is measured in hundreds of millilitres, not thousands, so a 3,000 mL core has headroom by design. The interval is then set by how much liquid arrives between checks, by positioning and by skin tolerance rather than by the core figure.

Disposable underpad used in resident personal care alongside a brief

Consider what a five-change day actually divides. A resident producing roughly a litre and a half across twenty-four hours, spread over five or six changes, puts a few hundred millilitres into each product. The 3,000 mL core is not being filled; it is providing margin for the interval, for a resident who voids twice between checks, and for the pressure that squeezes liquid back when the product is saturated.

Where facilities get into difficulty is treating the figure as a budget. A care plan that stretches an interval because the pack claims a large capacity will produce leakage, and the leakage will be recorded as a product failure when it is a schedule failure. The reverse also happens: an interval shortened to compensate for a poor fit consumes more product than the absorbency ever required.

Product tier Typical use in a unit Change rhythm to assess What to watch
Day-use brief around 3,000 mL Mobile residents, toileting programme, daytime checks Every two to four hours while awake Leakage at the leg cuff after a long sit
Higher-capacity day brief around 4,000 mL Residents needing assistance to transfer, longer intervals Three to four checks a day plus one at night Core bunching when the resident is repositioned
Overnight brief around 5,000 mL Residents who sleep through, night-time only One change overnight, one at wake Skin dryness at the morning change
Pull-on style Rehabilitative residents who stand and walk Toileting schedule rather than clock Whether the product can be pulled down without tearing

Which factors move a change schedule more than absorbency?

Five factors routinely outweigh the millilitre figure. Fluid intake and diuretic timing concentrate urine into a predictable window, which is why a schedule that ignores medication timing produces two heavy changes and four light ones. Mobility decides whether a resident can be toileted instead of changed. Skin condition decides whether the interval can be extended at all, because a resident with compromised skin needs a shorter interval regardless of capacity.

Fit decides whether the product works. A brief that is too large gaps at the leg cuff; one that is too small leaves the core compressed and the backsheet stretched. Both failures look like absorbency problems in the leakage log and both are solved by refitting rather than by buying a higher tier.

The fifth factor is staffing rhythm. A change schedule that requires a two-person transfer at a time when only one aide is on the floor will slip, and a slipped schedule produces leakage that no product change will fix. Writing the schedule around the actual staffing pattern is a nursing decision, and it should be taken before the purchasing decision.

When does an underpad accompany a brief?

Underpads and briefs solve different problems, and facilities that buy them together usually get the ratio wrong once. An underpad protects the bed or chair surface during care, during a toileting programme, and for a resident who is repositioned frequently. A brief is worn. Many units use both for the same resident, and the consumption rates are unrelated: one resident may use five briefs a day and half an underpad, another two underpads and no brief.

Packaged disposable underpads and bed sheets stacked in a care facility storeroom

The image above shows the underpad in the position it is actually used, under the resident rather than as a substitute for a garment. The [60 by 90 cm five-layer underpad with a SAP core](https://clinieco.ca/products/clinieco-medical-underpad-60-90cm-5-layer-with-sap-vacuum-compressed-50-pack) is the size most Canadian long-term care units stock for bed protection, and it is bought on a different cycle from briefs because the count per resident per day is lower. Facilities that store both in the same room should label the shelves by product type rather than by supplier, because the two are picked at different moments in the care routine.

How should a unit build a par level it can hold?

Start with the arithmetic, then adjust it with observation. Residents multiplied by changes per day multiplied by thirty gives the monthly base. For a 32-resident unit at five changes a day that is 4,800 units. Add a buffer for admissions, for heavier-use days and for the days when a delivery slips, and the buffer is usually expressed as days of cover rather than as a percentage.

Line in the calculation 32-resident unit at five changes a day What changes it
Residents 32 Admissions, respite beds, unit closures
Changes per resident per day 5 Acuity, toileting programme, night roster
Days in the order cycle 30 Two deliveries a month shortens the cycle
Base monthly quantity 4,800 units —
Buffer as days of cover 5 to 7 days of use Delivery reliability, storeroom size

Then translate the buffer into storage. A month of briefs for 32 residents occupies a substantial volume, and a unit that orders monthly without the shelf space ends up storing cases in a corridor, which is a fire and infection-prevention problem rather than a supply problem. Splitting the order into two deliveries with the same total quantity solves it without changing the price basis.

The [long-term care collection](https://clinieco.ca/collections/for-long-term-care) groups the absorbent products by tier so a unit can price a mixed order without opening four product pages. Sizing the mix matters as much as sizing the total. A unit that stocks one tier will run short on the residents who need more, so most facilities carry a day tier, an overnight tier and a pull-on style for rehabilitative residents. The [day-use 3,000 mL brief](https://clinieco.ca/products/clinieco-medical-day-comfort-adult-incontinence-briefs-3-000ml-60-pack) covers the standard daytime routine, the [4,000 mL Day Pro brief](https://clinieco.ca/products/clinieco-medical-adult-incontinence-briefs-60-pack-m-l) covers residents who need a longer interval, and the [overnight 5,000 mL Night Plus brief](https://clinieco.ca/products/clinieco-medical-night-plus-adult-incontinence-briefs-5-000ml-overnight-60-pack) is bought for the night roster. Residents on a toileting programme are usually served by a [pull-on brief](https://clinieco.ca/products/clinieco-adult-pull-on-briefs-maximum-60-pack), which can be pulled down without being removed.

What should the change record contain?

Four fields, written at the point of care: the time, the product code, the skin condition, and any leakage observed. The product code is the field most often left out and the one that makes the record useful, because it turns a complaint into a comparison. When a unit changes supplier and leakage rises, the record shows whether the increase is tied to one product tier or to one shift.

That record also supports the assessment conversation. A resident whose changes have moved from four to six a day is a clinical signal, and the count is only visible if it has been written down. Facilities that document continence care for inspection purposes usually find that the same fields serve the assessment, the supply order and the audit.

What should a purchase order state?

Name the tier, the size range, the absorbency claim and the standard it is measured against. State the pack configuration, because a case of 60 and a case of 120 change the storage and handling picture without changing the unit price basis. Add the establishment number of the supplier, so the licensing position is on the file rather than in an email.

Then agree the review date. Absorbency tiers and resident acuity drift, and a product mix set two years ago is usually one tier too light for the current population. A quarterly review against the change records is the least costly correction available, and it costs one meeting rather than one complaint.

Units that buy briefs, underpads and gloves on the same cycle can consolidate through the [long-term care supply page](https://clinieco.ca/pages/long-term-care) and a [wholesale and bulk quote](https://clinieco.ca/pages/wholesale) that carries one invoice and lot-level documentation per line. Facilities recording product codes on the change record can keep the specification and lot details for each delivery in the [compliance log centre](https://clinieco.ca/pages/compliance-log-center), so a leakage review starts from documents rather than from memory. Reselling? become a distributor.

References

  1. ISO 11948-1:1996, Urine-absorbing aids, Part 1: Whole-product testing (checked 9 November 2026)
  2. ISO 11948-2:1998, Urine-absorbing aids, Part 2: Determination of short-time liquid release under conditions of light incontinence and low pressure (checked 9 November 2026)
  3. 21 CFR 876.5920, Protective garment for incontinence (checked 9 November 2026)
  4. ISO 10993-1:2018, Biological evaluation of medical devices (checked 9 November 2026)
  5. ISO 14971:2019, Medical devices, application of risk management to medical devices (checked 9 November 2026)
  6. ISO 13485:2016, Medical devices, quality management systems (checked 9 November 2026)
  7. ISO 15223-1:2021, Symbols to be used with information supplied by the manufacturer (checked 9 November 2026)
  8. ISO 2859-1:1999, Sampling procedures for inspection by attributes, schemes indexed by acceptance quality limit (checked 9 November 2026)
  9. ISO 2859-4:2020, Sampling procedures for inspection by attributes, assessment of declared quality levels (checked 9 November 2026)
  10. ISO 9073-1:1989, Textiles, test methods for nonwovens, determination of mass per unit area (checked 9 November 2026)
  11. ISO 9073-4:2021, Nonwovens, test methods, determination of tear resistance (checked 9 November 2026)
  12. OSHA 1910.1030, Bloodborne Pathogens (checked 9 November 2026)
  13. World Health Organization, WHO Guidelines on Hand Hygiene in Health Care (checked 9 November 2026)
  14. World Health Organization, Infection prevention and control (checked 9 November 2026)
  15. World Health Organization, Health-care waste fact sheet (checked 9 November 2026)

Printable companion: the free sterilization log sheet lays out the fields an inspection asks for, so the record is written down as you work instead of reconstructed later.

Want the sheet filled in for your cycle type rather than a blank form? The sterilization log generator prints a record with the columns your reprocessing documentation needs.

Buying for a facility? Open a wholesale and institutional account for case pricing, purchase-order billing and a named account contact.

Related Reading

Frequently Asked Questions

What does ISO 11948-1 measure?

It gives a method for determining the absorption capacity of the absorbent core of a body-worn urine-absorbing aid. It is a whole-product test of the core, and it does not measure rewet under body weight, fit, odour control or skin dryness after a change.

Is ISO 11948-2 still current?

No. Part 2, which addressed short-time liquid release under light incontinence and low pressure, was withdrawn in December 2003. A supplier citing part 2 today is citing a withdrawn document, which is worth asking about.

Does a 3,000 mL rating mean the brief can hold 3,000 mL of urine?

It means the absorbent core reached that capacity in a laboratory test. A change interval is built on the volume produced between changes, on positioning and on how the product fits, so the rating is a comparison tool rather than a fill limit.

How often should a brief be changed?

Most facilities work to a check-and-change rhythm through the day and a longer interval at night for residents who sleep through. The interval is set by assessment, fluid intake and skin condition, and it should be recorded rather than assumed.

How do I calculate a monthly par level?

Multiply residents by changes per day by thirty, then add a working buffer for admissions and heavier-use days. A 32-resident unit on five changes a day consumes about 4,800 briefs a month before any buffer, which is the number a par level should start from.

When is an underpad used instead of a brief?

An underpad protects the bed or chair surface during care and for residents on a toileting programme, while a brief is worn. Many facilities use both, and the split matters for ordering because the two products are consumed at different rates.

Do briefs need a Canadian device licence?

Absorbent incontinence products are regulated as medical devices in Canada, and the licensing obligations sit with the licence holder. CliniEco Medical is a licensed medical device establishment (MDEL #35334), and a facility can ask any supplier for the establishment number on the invoice.

What should the change record contain?

The time, the product code, whether the skin was clean and intact, and any leakage observed. Recording the product code is what lets a unit compare a new brief against the one it replaced when leakage complaints start.

Last updated: November 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).