Case Review: A Manitoba Care Home's Glove Par Levels After a Resident Census Change

Par levels are usually set once and then quietly stop matching reality. When a Manitoba care home moved from 96 to 112 residents over two quarters, its glove par level stayed at the number set the year before, and the facility began running two-week gaps on large gloves while sitting on fourteen months of small. The gloves in question were a CliniEco Medical Nitrile Gloves — 3.5mil Standard, Blue, Powder-Free, 1,000 Gloves (10-Box Case)3.5 mil blue nitrile exam glove supplied in 1,000-glove cases. This review covers the arithmetic used to rebuild the par, the size mix shift that caused the shortage, and the reorder rule that has held since.

This is a composite worked example built from standard inventory practice. It does not describe a single named facility.

What changed when the census moved?

The facility added sixteen residents, a 17 percent increase, but glove consumption rose 26 percent over the same period. The difference came from acuity: the new residents arrived with more mobility assistance needs and two additional palliative care beds, both of which raise glove use per resident-day. Headcount alone understated the change.

The facility's original par was six weeks of cover based on a consumption figure of 19 gloves per resident-day. At 112 residents that formula gave 14,896 gloves for six weeks, or about 15 cases. Actual usage in the first month after the census change was 22 gloves per resident-day, which needed 17 to 18 cases for the same six weeks. The par was short by three cases from the first month, before any size mix effect.

case of CliniEco blue nitrile examination gloves for care home par level ordering

How do you recalculate glove par levels?

Start from measured issue data rather than from a formula. Pull four weeks of issue records by size, divide total gloves by resident-days, and treat that as the baseline. Then apply a cover period and a safety stock, and split by size rather than holding a single facility-level number.

Step Calculation Result for this facility
Baseline use Measured gloves divided by resident-days 22 gloves per resident-day
Weekly demand 22 x 112 residents x 7 days 17,248 gloves
Cover period Six weeks of working stock 103,488 gloves, about 104 cases
Safety stock Two weeks additional 34 cases
Total par Working plus safety 138 cases facility-wide

That par looks large because the facility is large. The important change was not the total but the split: the previous par was held as a single number, so the supply room could be technically at par while the large size was empty.

Which sizes ran short, and why?

Large and extra large ran short while small accumulated. The cause was a shift in staff and resident mix. The new care aides were predominantly in the large and extra large range, and the palliative beds required double-gloving for certain tasks, which consumes sizes in pairs rather than singly.

Size Old share Measured share Effect
Small 25 percent 17 percent Overstock, 14 months of cover
Medium 35 percent 34 percent Stable
Large 30 percent 37 percent Two-week gaps
Extra large 10 percent 12 percent Occasional gaps

The fix was a size-level minimum rather than a percentage. Each size now has a floor equal to three weeks of measured demand, and the reorder trigger fires on the size, not on the facility total. That single change removed the situation where a full storeroom still could not supply a shift.

What did the first two months show?

The first month with the new par ran one short gap on large, caused by an outbreak unit that opened mid-month and consumed four cases in nine days. The second month ran with no gap and ended with 11 days of cover remaining on the tightest size. The facility treated the outbreak draw as a planned event and added a two-case outbreak reserve to the large and extra large lines.

The financial result was a one-time increase in working capital, offset within the quarter by the disappearance of emergency orders. Emergency orders had been arriving two or three times a month at a higher unit cost plus freight, and those orders stopped once the size floors were in place.

nitrile glove cuff and texture close up for size verification

What is the revised reorder rule?

Reorder when any size falls below three weeks of measured demand, not when the storeroom looks low. Review the baseline quarterly, and immediately after any change in census above 10 percent, any new unit opening, or any change in acuity mix. Keep the measured gloves-per-resident-day figure on the supply room wall, because it is the only number in the calculation that changes without anyone noticing.

One more rule came out of the review: never let a single person own both the par calculation and the ordering. The gap between the two was where the facility's error lived for two quarters.

Download the printable par level worksheet, model the arithmetic with the clinic supply planner, and for infection control questions around glove use, ask a sterilization compliance specialist.

The glove line used in this review is the 3.5 mil blue nitrile exam glove, 1,000 per case, ordered in ten-box cases so each size can be held to its own floor.

Ordering for a clinic, lab or care home? Wholesale and multi-site ordering covers case pricing and account setup, and the B2B wholesale collection lists the lines stocked for institutional buyers. Reselling? become a distributor.

Related reading

sterilization compliance hub · gloves per bed month in care homes · glove sizing: measuring staff hands · nitrile glove sizes and specs in Canada

Frequently Asked Questions

How do I calculate glove par levels for a care home?

Measure four weeks of issue data by size, divide total gloves by resident-days to get gloves per resident-day, multiply by weekly census for weekly demand, then add six weeks of working stock and two weeks of safety stock.

Why did glove use rise faster than the resident count?

Acuity drives glove use more than headcount. Additional palliative beds and more mobility assistance raise gloves per resident-day, so a 17 percent census increase can produce a 26 percent consumption increase.

Should a care home hold one glove par level or one per size?

One per size. A single facility-level par can be met while the large size is empty, which is exactly the situation that causes shift-level shortages. Set a floor of about three weeks of measured demand for each size.

How much safety stock should a care home hold for outbreaks?

Two weeks of measured demand plus a small outbreak reserve on the two largest sizes. An outbreak unit can draw four cases in nine days, which a standard safety stock will not cover.

How often should glove par levels be reviewed?

Quarterly, and immediately after any census change above 10 percent, a new unit opening, or a change in acuity mix. The gloves-per-resident-day figure is the number that drifts without notice.