Therapy Devices

Therapy devices used between appointments and at home — electrical stimulation, therapeutic ultrasound, sequential compression, heat and red light, and the consumables those devices need. Fourteen listings, and the useful split is by mechanism rather than by brand: a TENS unit, an EMS unit, an ultrasound head, a compression sleeve and a heating pad do different things to tissue, and they need different accessories. What each unit is, what it runs on and what the patient has to bring to the session are set out below.

1 product
More about Therapy Devices

What is in this therapy device collection, and what does each unit need to run?

Fourteen listings across five mechanisms. Formats are the ones on the current listings; several lines are shown in advance of stock, so each product page states its own status.

Therapy devices: unit, mechanism and what it needs to run
Listing Mechanism Runs on / needs
TENS unit — 4 channel, 24 mode Electrical nerve stimulation for pain Rechargeable; eight self-adhesive pads supplied
Wireless TENS unit — app control Electrical nerve stimulation for pain USB-C rechargeable; phone app sets the programs
TENS unit — 24 mode, dual channel Electrical nerve stimulation for pain Rechargeable; electrode pads
EMS muscle stimulator — 24 mode Electrical muscle stimulation Rechargeable; pads placed over the muscle belly
Conductive gel — 250 mL Coupling medium Used with the ultrasound head and with electrodes
Ultrasound therapy device — portable Acoustic energy into tissue Mains or rechargeable; gel required at the head
Sequential compression device — leg system Intermittent pneumatic compression Mains power; garment sleeves
Electric heating pad — wearable Conductive heat Mains or USB as listed; six heat settings
Infrared warmth belt — 660 nm and 850 nm Light emission plus warmth USB-C rechargeable, wearable
Cordless knee massager — warmth and vibration Vibration plus warmth Rechargeable wrap
Electronic acupuncture pen — point finder Localised electrical point stimulation Battery; no needles and no skin penetration
Anti-snoring device — mandibular advancement Mechanical jaw positioning No power; adjustable mouthpiece
Portable mesh nebulizer Aerosol delivery USB-C rechargeable handheld
Desktop compressor nebulizer Aerosol delivery Mains power; tubing circuit

TENS and EMS look identical — what is the actual difference?

They use the same hardware and often the same pads, and they are aimed at two different tissues. A TENS unit (transcutaneous electrical nerve stimulation) is set to modify how pain is conducted, so the pads go over the painful area or over the nerve serving it, and the sensation the patient should report is a comfortable tingling. An EMS unit (electrical muscle stimulation) is set to produce a visible muscle contraction, so the pads go over the muscle belly and the amplitude is raised until the muscle works.

That single difference explains the rest. A unit that offers both families of programs can do both jobs, because the machine only supplies pulses; what changes is placement, amplitude and the program selected. It also explains why the pads and the gel are the consumable line in this collection: an electrode that has lost its adhesive layer passes current unevenly, and a session that feels different from the last one is usually an electrode problem rather than a device problem.

The contraindication list in the manufacturer's instructions is the operative document, and the entries that recur across these devices concern implanted electronic devices such as pacemakers, the front of the neck and the head, broken or irritated skin, and use during pregnancy. A clinic lending a unit to a client should hand over that list with the device, not summarise it from memory.

What do the 24 modes on a TENS or EMS unit actually change?

A mode is a stored combination of pulse frequency, pulse width and, in some programs, a cycling pattern. Twenty-four modes therefore describe twenty-four stored settings, not twenty-four therapies: what changes an outcome is where the pads sit, how high the amplitude goes, how long the session runs and how often it is repeated.

This matters at the point of purchase. A unit with fewer programs and a clear amplitude control is easier to teach than a unit with a long menu, and the staff member who sets it is the person who determines whether the session is repeatable. For a clinic that hands devices to clients, a short written protocol — placement, setting, duration, end point — does more work than the mode count on the box.

Ultrasound, compression, heat and light: which device does what, and what does each need?

Therapeutic ultrasound couples acoustic energy into tissue through a coupling medium, which is why the gel in this collection is not an optional extra: an air gap between the head and the skin reflects the energy back into the transducer. The head must be kept moving, and the gel is applied to both the head and the skin before the session starts.

Sequential compression is mechanical. Garment sleeves inflate in sequence to move fluid along the limb, so the device needs the sleeve that fits the limb and a power outlet; the sleeve is the part that has to match the patient, not the pump. Heat and light sit in a third group: a wearable heating pad delivers conductive warmth through six settings, and the infrared belt emits at 660 nm and 850 nm while adding warmth, which is a different mechanism from a hot pack even though both feel warm.

Because the mechanisms differ, they are not interchangeable in a care plan. Substituting one for another because it is the unit on the shelf changes what the session does, and the substitution should be a clinical decision rather than an inventory one.

How does Canada regulate therapy devices compared with the United States?

Most of the units in this collection make a therapeutic claim, and a claim is what turns a consumer product into a regulated device. In Canada that means a licence under the Medical Devices Regulations plus an establishment licence for the distributor (CliniEco Medical: MDEL #35334). In the United States the same unit sits under a CFR section, and the section decides whether a premarket submission is required.

Therapy devices: Canadian and United States frameworks compared
Item Canada United States
TENS unit for pain relief Licensed device under the Medical Devices Regulations; distributor holds an MDEL (CliniEco Medical: MDEL #35334) 21 CFR 882.5890, transcutaneous electrical nerve stimulator for pain relief
EMS / muscle stimulator Licensed device when a muscle-stimulation claim is made 21 CFR 890.5860, ultrasound and muscle stimulator
Powered heating pad Device when sold with a therapeutic claim 21 CFR 890.5740, powered heating pad
Therapeutic massager Device when sold with a therapeutic claim; otherwise a consumer product 21 CFR 890.5660, therapeutic massager
Labelling English and French English

The practical consequence for a buyer is that the claim on the box, not the look of the device, decides which framework applies — and a device imported for one market carries the labelling of that market.

Does a TENS unit cleared for the United States need anything else to be sold in Canada?

Yes — a separate Canadian authorisation. A premarket clearance in the United States is a decision by the FDA about that market, and it does not travel; the device needs its own licence under the Medical Devices Regulations to be sold in Canada, and the establishment distributing it needs a Medical Device Establishment Licence (CliniEco Medical: MDEL #35334). The test evidence behind the two decisions is often the same, which is why the gap is easy to miss: the reports travel, the authorisations do not.

For a clinic that buys across the border, the practical check is the identifier on the carton and the language of the labelling, not the presence of a familiar mark from the other country.

What should a clinic check before handing a device to a client?

Five things: the manufacturer's instructions travel with the unit; the electrodes or gel that belong with it are supplied at the same time; the electrical approval mark is valid for a 120 V Canadian outlet; the contraindication list has been read with the client; and the loan is recorded against that client, because electrodes, sleeves and mouthpieces are single-client items even when the device is reused.

Between clients, the device housing is wiped with a disinfectant that the manufacturer states is compatible with it, and anything that touches skin — pads, sleeves, the mouthpiece of an oral appliance — is replaced or assigned to one client. Immersing an electrical therapy device is never part of a cleaning procedure, and a device with a damaged lead should leave service rather than be taped and returned to the shelf.

Related reading

Two neighbouring collections carry the parts of the routine that are not devices: health monitors for measurement, and medical aesthetics for the treatment-room side.

Background on the choices in this collection: TENS or EMS: choosing muscle stimulation devices for Canadian rehab clinics, ultrasound therapy devices for physiotherapy clinics, and home physiotherapy equipment: TENS, ultrasound and massage devices.

Frequently asked questions

Does a TENS unit also work as an EMS unit?

Only if the unit offers both program families. The hardware is the same, but the settings differ: TENS targets nerve conduction with a comfortable tingling, EMS targets muscle contraction at a higher amplitude over the muscle belly.

Why does ultrasound therapy need gel?

The gel is the coupling medium. An air gap between the treatment head and the skin reflects the acoustic energy instead of transmitting it, so the session delivers far less than intended and the head can overheat.

Are electrode pads reusable?

Self-adhesive pads are reusable for a limited number of sessions and are single-client items. Once the adhesive layer stops holding, current passes unevenly and the session changes; that is the point to replace them rather than to press harder.

Can a care home lend these devices to residents?

Yes, with the manufacturer's instructions, the contraindication list and a loan record per resident. Pads, sleeves and oral appliances stay with one person; the device itself is cleaned between users according to its instructions.

Where do clinics and care homes order these units and their consumables?

The clinic supply planner converts treatment rooms and clinical days into a monthly order, the compliance log centre holds the printable record sheets, and multi-site or institutional orders run through the institutional account enquiry page.

Standards and sources

Editions and links were checked on 6 November 2026. 21 CFR 882.5890, transcutaneous electrical nerve stimulator for pain relief; 21 CFR 890.5860, ultrasound and muscle stimulator; 21 CFR 890.5740, powered heating pad; 21 CFR 890.5660, therapeutic massager; Health Canada, medical devices; Public Health Ontario, infection prevention and control for clinical office practice. Section titles were read from the current eCFR text; the CFR is cited by section rather than by year, because the section number is what a submission or a file references.

Distribution: CliniEco Medical — MDEL #35334. Formats and accessories are those printed on the current product listings; confirm the device model against the treatment protocol before ordering.