Pipetting & Transfer

Transfer pipettes, serological pipettes and parafilm for moving and sealing small volumes.

Eight packs cover the routine work between a pipettor and a bottle: transfer pipettes from 1.5 mL for microtubes up to 7 mL for a 15 mL tube, exact volume pipettes from 20 to 500 microlitre, 4.5 mL blood bank pipettes graduated to 2 mL, and a lab consumables pack that carries sealing film and serological pipettes.

1 product
More about Pipetting & Transfer

Which transfer pipette volume fits a 15 mL tube or a microtube?

A 7 mL transfer pipette with a large bulb, graduated to 3 mL reaches the bottom of a 15 mL tube and a 120 mL specimen container without a second vessel. For a microtube or a cryogenic vial, the 1.5 mL pipette with a small bulb and an extended tip fits a narrow neck where a 5 mL body will not pass.

Both formats sit on a one-piece polyethylene body, so there is no separate bulb to lose. The graduated 7 mL version marks 1, 2 and 3 mL for a measured transfer.

How many transfer pipettes are in a pack or a case?

Pack counts follow the volume and the format rather than the stem length. The 3 mL, 4.5 mL, 5 mL and 7 mL ranges hold 250 pipettes per pack in 20 packs, so 5,000 per case, in the non-sterile working pack. The 1.5 mL pipette holds 500 per pack in six packs, so 3,000, and the extended-tip 7 mL holds 400 in ten, so 4,000.

Volume and format Tip or bulb Pack count Bench use
1.5 mL transfer pipette Small bulb, extended tip 500 per pack, 3,000 per case Microtubes, cryogenic vials, narrow-neck containers
3 mL transfer pipette Short bulb, graduated to 1 mL 250 per pack, 5,000 per case Rack-side additions where a 5 mL body stands too tall
4 mL transfer pipette Short stem or standard stem 250 or 500 per pack, up to 5,000 per case Shallow vessel on one side, deep tube on the other
4.5 mL blood bank pipette Blood bank shape, graduated to 2 mL 250 per pack, 5,000 per case Serology and transfusion service steps
5 mL transfer pipette Large bulb, standard or extended tip 250 or 500 per pack, 5,000 per case Specimen containers, reagent addition, strip work
7 mL transfer pipette Large bulb, graduated to 3 mL 250 or 400 per pack, 4,000 to 5,000 per case 15 mL tubes and 120 mL containers
20 to 500 microlitre exact volume pipette Fixed bulb, stem length matched to volume 1,000 to 5,000 per case in resealable bags Fixed-volume reagent steps without a pipettor

Sterile formats are counted per case rather than per pack: individually wrapped packs hold 500 per case across the range, and peel packs of 20 also make 500 per case.

Should a laboratory buy sterile individually wrapped pipettes or non-sterile working packs?

Use the non-sterile working pack where the pipette is a transfer tool on a staining, dilution or reagent bench. Use the sterile individually wrapped format where the step has to come from an unopened wrapper: cell work, microbiology, and any step a transfusion service documents. Both configurations share the same body and graduation, so the choice is the sterile claim rather than the shape.

How do you choose between a short stem and a standard stem?

A short stem fits a shallow vessel, a small rack and a tight rack position where a long pipette would tip the container or touch the bench. The standard stem reaches the bottom of a 15 mL tube or a deep container, and it is the format a dispensary uses for decanting from a bottle. Because both are 4 mL, the decision is reach rather than volume.

The same question decides the tip on a 5 mL pipette: the standard tip covers a specimen container, and the extended tip reaches a narrow vessel the standard tip cannot enter.

When is an exact volume pipette worth it instead of a graduated one?

Exact volume earns its place where a step depends on a repeatable small volume and a pipettor is unavailable or slower than the task: adding a fixed reagent to a strip, inoculating a fixed volume into broth, transferring a stain. The bulb is moulded to one volume, so the draw stops at that volume and the operator does not watch a graduation.

The range runs from 20 microlitre at 53 mm to 500 microlitre at 120 mm, with stem length matched to volume. The 20 to 100 microlitre band covers most fixed-volume steps, and 150 to 500 microlitre covers larger reagent additions. Bag counts shrink as the bulb grows: 5,000 pipettes in ten bags at 20 microlitre, 2,500 in five bags from 50 to 250 microlitre, and 1,000 in two bags from 300 to 500 microlitre.

What does a blood bank pipette do that a standard transfer pipette does not?

A blood bank pipette is a shape rather than a volume: long enough to reach into a segment or a tube, graduated to 2 mL so a plasma or cell suspension volume can be read in the pipette itself, and sized at 4.5 mL so a full draw covers a typical serology step. The sterile pack is wrapped individually rather than in peel packs, which suits a clean field.

How should transfer pipettes be stored at the bench?

A 250-pipette pack fits a bench drawer, which keeps the working pack out of the carton and away from water on the bench. Non-sterile formats are bagged rather than boxed, so a pack can sit in a beaker without the carton taking water, and the sterile formats carry the lot on the outside of the sealed bag.

Where can a Canadian laboratory order transfer pipettes by the case?

Where to order in Canada is the case and volume supply collection, which carries the same pack and case units listed here, and each product page shows the pack count in its variant list. Every format ships from North American stock. For a year of bench supply, the clinic supply planner converts weekly use into cases before you order.

Two pages answer the specification questions that come up at order time: the class and colour code for serological pipettes and the rules for laboratory sealing film. Both product families sit in one pack here: CliniEco lab consumables with parafilm and serological pipettes.