UN3373 Specimen Bags: IATA 650 Packaging & Sizes (Canada)

CliniEco specimen transport bags with leak-proof seal

Every morning, clinics across Canada hand blood tubes and urine cups to couriers headed for referral labs. The bag those samples travel in is easy to overlook — until a shipment gets refused, delayed, or flagged during an audit. This guide covers UN3373 classification, how IATA Packing Instruction 650 shapes specimen transport bags, and what Transport Canada expects under the TDGR, so your front desk and lab staff can ship with confidence.

CliniEco specimen transport bags with leak-proof seal

What does UN3373 classification mean for your lab?

UN3373 is the proper shipping name assigned to Biological Substance, Category B — clinical samples that are unlikely to cause disease but still need controlled handling. Routine blood draws, urine cultures, nasal swabs and biopsy material typically fall here. The classification originates in the UN Model Regulations and is adopted by IATA's DGR and Canada's TDGR alike.

Category A is a different world. If a sample may contain a pathogen capable of causing permanent disability or life-threatening disease, it ships as UN 2814 or UN 2900 under far stricter rules. Misclassifying a Category A specimen as Category B is a common compliance failure in diagnostic labs — and the kind of error that surfaces in Transport Canada inspections.

What does IATA 650 require for specimen transport bags?

When specimens fly, IATA's Dangerous Goods Regulations take over, and Packing Instruction 650 is the section most clinics will ever need. PI 650 requires a triple packaging system:

  • A leak-proof primary receptacle — the tube or vial holding the sample
  • Leak-proof secondary packaging around the primary, with enough absorbent material to soak up the entire contents if the tube breaks
  • A rigid outer packaging that survives normal transport conditions and carries the UN 3373 marking

The layers work as a system, not a stack of bags. Absorbent material sits between primary and secondary layers, and the outer package handles drops, stacking and vibration. In many clinic workflows the specimen transport bag doubles as the secondary layer: the tube goes in with its absorbent wrap, the bag seals shut, and paperwork rides in the outer pouch.

What does the 95 kPa leak test prove?

That 95 kPa figure on 95 kPa specimen bags comes straight from the UN packaging standards behind PI 650. Primary receptacles for infectious substances must withstand an internal pressure differential of at least 95 kPa without leaking — roughly the pressure shift a sample experiences during air transport at altitude. Packaging that passes earns its certification; packaging that doesn't is a liability in your courier's hands.

CliniEco's medical specimen transport bags are rated to that 95 kPa standard, so the secondary layer holds up under real shipping conditions. Compared to generic zip-close bags sold as "sample bags," a 95 kPa rated bag removes a variable from your audit trail before the courier arrives.

Requirement 95 kPa specimen bag Generic zip-close sample bag
Pressure rating Tested to a pressure differential of at least 95 kPa without leaking No pressure rating and no test basis
Role in the package Leak-proof secondary layer in a three-layer system Not a recognised packaging layer
Absorbent material Paired with a pad sized to absorb the entire contents of the primary receptacle Usually absent; the absorbent has to be added and sized separately
Requisition handling Separate document pocket, so the requisition never travels inside the secondary layer Paperwork shares the same space as the sample
Rigid outer packaging Still required — the bag on its own is not the outer layer Still required, and the bag cannot substitute for it
Audit trail Removes a variable from your audit trail before the courier arrives Removes nothing an inspector can check

laboratory specimen handling in Canadian clinics

Marking, Labelling and the Biohazard Symbol

A compliant shipment carries more than a biohazard symbol. Under IATA 650 and TDGR, Category B packages need the UN 3373 marking on the outer packaging, the proper shipping name "Biological Substance, Category B" nearby, and the shipper's name and address. The biohazard label on the specimen bag itself tells lab staff and couriers to handle the contents carefully before sealing.

Health Canada's biosafety guidance and the Public Health Agency of Canada's laboratory standards reinforce the same idea: clear labelling prevents the exposures that happen when a bag is mistaken for routine mail. PHAC's pathogen safety data sheets list transport requirements for specific organisms, and Toronto General's lab protocols follow the same IATA framework. The primary receptacle side is covered by UN 3373 and IATA packing instruction 650; CSA Z316.6 applies to sharps containers, not to specimen bags.

What does Transport Canada require for road transport?

Air isn't the only route. When specimens move by road within Canada, the Transportation of Dangerous Goods Regulations — administered by Transport Canada — govern the shipment. TDGR aligns closely with the UN system, so a package built for IATA 650 generally satisfies road transport too, but the paperwork differs. TDGR requires shipping documents that describe the goods, and consignors must keep copies on file for the period the regulations specify and produce them during an inspection.

Record keeping is where many clinics slip. A shipping log with the date, contents, courier, tracking number and staff initials sounds administrative, but it's the first thing an auditor asks for. Labs accredited to ISO 15189, the international standard for lab quality, already treat this as routine — and the documentation habits hold whether you buy from McKesson, Medline or a specialty supplier like CliniEco.

Build a Simple Specimen Transport Workflow

If you're setting this up from scratch, a practical checklist looks like this:

  • Stock 95 kPa specimen transport bags at every draw station
  • Pair each bag with an absorbent pad sized for the largest tube it will carry
  • Apply the UN 3373 marking and Category B label to the outer package
  • Log every outbound shipment before the courier leaves
  • Review classification training with lab staff once a year

The same mindset covers the rest of the clinic's consumables. CliniEco's leak-proof red biohazard waste bags handle regulated waste that stays on site, and its sterile 12-ply gauze sponges keep draw stations stocked between shipments. Standardizing the transport lane — from the 95 kPa bags to the labelling and the logbook — turns a compliance checklist from a scramble into a routine.

None of this requires a dedicated compliance officer. Specimen transport bags that meet UN3373 packaging requirements, staff who can tell Category A from Category B, and a shipping log that never gets skipped will carry a small clinic through most audits. Standardize on IATA 650 compliant bags and the paperwork gets simpler — one less thing to explain to an inspector, and one more layer of protection for the people handling your samples.

Related Reading

Explore more guides in this category:

What can an inspector actually measure on a UN3373 package?

Packing Instruction 650 reads like a long document and behaves like a short list of numbers. Every one of them can be checked with a ruler, a scale or a look at the outer box, which is why they are the first things a courier or an inspector tests. The table collects them in one place; the answers below explain what each number is for.

IATA Packing Instruction 650 for UN3373 Category B, checked against the 66th edition (1 January 2025)
Item in the package What PI 650 requires
Packaging layers Three components: primary receptacle, secondary packaging, rigid outer packaging
Primary receptacle, liquid Leakproof, and not more than 1 L per receptacle
Secondary packaging, liquid Leakproof; multiple fragile primaries individually wrapped or separated
Absorbent material Between primary and secondary, in quantity sufficient to absorb the entire contents of all primary receptacles
Pressure differential Primary receptacle or secondary packaging must withstand 95 kPa without leakage
Outer packaging, liquid Not more than 4 L per package, excluding ice, dry ice or liquid nitrogen
Outer packaging, solid Not more than 4 kg per package, except body parts, organs or whole bodies
Drop test 1.2 m in any orientation without leakage from the primary receptacle
Outer surface At least one surface measuring 100 mm × 100 mm minimum
UN3373 mark Diamond set at 45°, each side at least 50 mm, line at least 2 mm, characters at least 6 mm high, on one side of the package
Shipping name "Biological Substance, Category B" in letters at least 6 mm high, beside the diamond mark
Contents list Itemised list of contents enclosed between the secondary packaging and the outer packaging
Shipper's declaration Not required for UN3373 under PI 650

Does a UN3373 shipment need a shipper's declaration?

Not under Packing Instruction 650, which states plainly that a Shipper's Declaration for Dangerous Goods is not required for Category B. What still applies is the air waybill and the marking on the box, and on the Canadian road leg the consignor's own paperwork: section 3.1(1) of the Transportation of Dangerous Goods Regulations requires the consignor to give the carrier a shipping document, or an electronic copy if the carrier agrees, before the carrier takes possession.

What are the quantity limits for one Category B package?

For liquids, no single primary receptacle may hold more than 1 L and the completed outer packaging may not hold more than 4 L. For solids, the outer packaging may not hold more than 4 kg, with an exception for body parts, organs and whole bodies. Ice, dry ice and liquid nitrogen used to keep specimens cold do not count against those limits, which matters for a lab that ships frozen samples in the same box as refrigerated tubes.

How much absorbent material does Packing Instruction 650 require?

Enough to absorb the entire contents of the primary receptacles, placed between the primary receptacle and the secondary packaging. The test is arithmetic, not visual: add up the worst-case volume in the secondary layer and check that the pad can take all of it, because the requirement is that a release must not compromise the cushioning material or the outer packaging. That is why a pad is specified by the largest tube a bag will carry, not by the bag's nominal size.

What does the 1.2 m drop test prove, and who runs it?

It proves the completed package can be dropped from 1.2 m in any orientation without the primary receptacle leaking. Capability may be shown by testing, assessment or experience, so the clinic's job is not to drop boxes in the parking lot but to buy packaging whose maker can demonstrate it — and to check a bag before re-use for the damage a previous shipment left behind. A bag that has already been compressed, torn at the seal or stretched at the zip is no longer the packaging that was qualified.

How big must the UN3373 mark and the Category B wording be?

The mark is a diamond set at 45° with sides of at least 50 mm, a line at least 2 mm wide, and characters at least 6 mm high, printed on a contrasting background on one side of the package. The proper shipping name "Biological Substance, Category B" goes next to it in letters at least 6 mm high. Overpacks have their own rule: unless every mark stays visible, the word "Overpack" must be added in lettering at least 12 mm high, and the marks reproduced outside.

Is UN3373 packaging the same in Canada and the United States?

The packaging numbers are harmonised, the paperwork is not. In the United States, 49 CFR 173.199 requires the same triple packaging, the same 1.2 m drop and the same 100 mm × 100 mm outer surface, and excepts Category B from the other requirements of the subchapter once those conditions are met. In Canada, the description, quantity and marking of the shipment sit on a shipping document the consignor must pass to the carrier under the TDG Regulations. For a clinic shipping to a Canadian referral lab, that means a bag specification imported from the US still fits the box — but the document behind it is a Canadian question.

Where do these figures come from?

Packaging requirements and quantity limits were read from IATA Packing Instruction 650, 66th edition, 1 January 2025 (IATA, PI 650). The US comparison was read from 49 CFR 173.199 (eCFR text, revision dated 2025-01-01, read through the Cornell LII edition), and the Canadian shipping-document rule from SOR/2001-286, section 3.1, current to 2026-09-30. All three were checked on 2026-10-28. The bag that turns the secondary layer into a compliant one is the CliniEco 95 kPa specimen transport bag — printed 95kPa, Specimen Transport Bag and BIOHAZARD panel, adhesive c95 kPa specimen bag, 100 per pack; the rigid outer box remains the shipper's responsibility.

Where can Canadian labs and clinics buy 95 kPa specimen transport bags?

In Canada the workable answer is a supplier who stocks the bag domestically and can say which primary receptacle it has been paired with — not a US packaging broker. UN3373 is the same entry on both sides of the border, but the courier lane, the lead time and the paperwork expectations are Canadian questions. The packaging rules themselves come from the UN Model Regulations, which IATA Packing Instruction 650 and the Canadian Transportation of Dangerous Goods Regulations both adopt, so a bag that meets the requirement here meets it there; what changes is how quickly you can restock a clinic that runs out mid-week.

The configuration that gets ordered most often is a 6 x 9 inch UN3373 bag, 95 kPa, 100 per pack, with the document pocket separated from the sample compartment so the requisition never travels inside the secondary layer. Two specifications decide whether a bag is usable in daily practice: absorbent material sized to absorb the entire contents of the primary receptacle, and a rigid outer package, because the bag on its own is not the outer layer. Sites running several collection points can request a bulk quote and keep the same configuration on every shelf. Sites that also run an in-house sterilizer can add 24-hour biological indicators for the monitoring side of that workflow.

The Canadian buying point: UN3373 and Packing Instruction 650 are the same requirements on both sides of the border, so what actually differs between suppliers is stock position and how the item is specified. A clinic that runs out of bags mid-week cannot wait on a cross-border shipment, and the detail the person packing the shipment reads first is the pressure rating printed on the bag itself rather than a claim on a catalogue page. CliniEco stocks the 6 x 9 inch UN3373 bag, 95 kPa, 100 per pack, with the rating on the bag and a separate document pocket for the requisition.

Related Reading

Frequently Asked Questions

What does UN3373 mean on a specimen transport bag?

UN3373 is the proper shipping name for Biological Substance, Category B — clinical samples that are unlikely to cause disease but still need controlled handling, such as routine blood draws, urine cultures, nasal swabs, and biopsy material. The classification comes from the UN Model Regulations and is adopted by both IATA's DGR and Canada's Transportation of Dangerous Goods Regulations.

What is the 95 kPa leak test on specimen bags?

The 95 kPa figure comes from UN packaging standards behind IATA Packing Instruction 650. Primary receptacles for infectious substances must withstand an internal pressure differential of at least 95 kPa without leaking — roughly the pressure a sample tube can see during air transport. A bag marked 95 kPa has been tested to that requirement, which is why labs and couriers look for the marking.

What is the triple packaging rule for shipping specimens?

IATA Packing Instruction 650 requires three layers: a leak-proof primary receptacle (the tube or vial), leak-proof secondary packaging with enough absorbent material to soak up the entire contents if the tube breaks, and a rigid outer packaging that carries the UN 3373 marking. In clinic workflows, the specimen bag often doubles as the secondary layer with the absorbent wrap around the tube.

What is the difference between Category A and Category B specimens?

Category B (UN3373) covers samples unlikely to cause disease in healthy people. Category A (UN 2814 or UN 2900) applies when a sample may contain a pathogen capable of causing permanent disability or life-threatening disease. Misclassifying a Category A specimen as Category B is a common compliance failure — and the kind of error surfaced in Transport Canada inspections.

Do specimen transport bags need to be rigid?

The primary and secondary layers must be leak-proof, and the outer packaging must be rigid enough to survive normal transport. A 95 kPa specimen transport bags with a rigid outer pouch satisfies the outer packaging role for most clinic-to-lab shipments. Check your courier's requirements and Transport Canada guidance for the exact configuration.

Can I buy 95 kPa specimen transport bags in Canada?

Yes. CliniEco Medical stocks UN3373 6 x 9 inch specimen transport bags, 95 kPa, in packs of 100, with the pressure rating printed on the bag and a separate document pocket for the requisition. The bag serves as the secondary layer of a three-layer package; a rigid outer container and absorbent material sized to the primary receptacle are still required, and both travel with the same order.

CliniEco Medical supplies 95 kPa specimen transport bags designed for clinic-to-lab workflows. Check the CliniEco website for specifications and bulk pricing.

Also read: learn medical waste bag film standards in our pillar article on dart impact and seal integrity.

Last updated: September 15, 2026. CliniEco Medical is a licensed medical device establishment (MDEL #35334).