Advanced TENS & EMS Therapy

The CliniEco TENS Unit Muscle Stimulator combines TENS (Transcutaneous Electrical Nerve Stimulation) and EMS (Electrical Muscle Stimulation) output in one portable unit. With 24 built-in modes and 40 intensity levels per channel, it is intended to be used as directed by a qualified clinician, and it ships with reusable electrode pads for repeat sessions.

Key Features

  • Dual Channel Design — Two independent output channels with 4 electrode pads, so two sites can be run at the same time
  • 24 Built-In Modes — TENS, EMS, massage, acupuncture, cupping and tapping programs
  • 40 Intensity Levels — Stepwise intensity adjustment from gentle to stronger output
  • Rechargeable Battery — Built-in 1500mAh lithium battery, USB-C charging, up to 40 hours of use
  • Large LCD Display — Clear backlit screen showing mode, intensity and timer
  • Session Timer — 15, 30, 45 and 60-minute presets
  • Pocket-Sized Portable — Compact design fits in any bag, comes with travel pouch

Product Specifications

Channels: 2 Independent Channels (4 electrode pads)

Modes: 24 Modes (TENS + EMS + Massage + Combo)

Intensity Levels: 40 Levels per Channel

Battery: 1500mAh Rechargeable Lithium-Ion

Charging: USB-C (cable included)

Battery Life: 30-40 Hours (depending on mode)

Channels 2 Independent Channels (4 electrode pads)
Modes 24 Modes (TENS + EMS + Massage + Combo)
Intensity Levels 40 Levels per Channel
Battery 1500mAh Rechargeable Lithium-Ion
Charging USB-C (cable included)
Battery Life 30-40 Hours (depending on mode)
Timer Settings 15, 30, 45, 60 minutes
Electrode Pads 12 Pads (6× 2" round + 6× 2"x4" rectangle)
Weight 145g
Certifications See manufacturer documentation (available on request)

What's in the Box

  • 1× CliniEco TENS Unit
  • 12× Electrode Pads (6 round + 6 rectangle)
  • 2× Lead Wires
  • 1× USB-C Charging Cable
  • 1× Electrode Pad Holder
  • 1× Travel Pouch
  • 1× User Manual (English/French)

♻️ Your trusted partner in sustainable healthcare — CliniEco Medical

Register your interest and we will confirm the Canadian release date and shipping window once stock is confirmed.

Specifications

  • Device: Dual-channel TENS unit, multiple modes with adjustable intensity, includes 4 electrode pads
  • Consumables / refills: Self-adhesive electrode pads, replaceable every 2–4 weeks
  • Packaging: Colour box with main unit, lead wires and electrode pads; user manual included

Full specification sheet available on request for institutional orders.

What is a TENS and EMS unit, in plain terms?

TENS is transcutaneous electrical nerve stimulation; EMS is electrical muscle stimulation, and portable units carry both output types in one device. The distinction sits in waveform and frequency: TENS programs are built around sensory-nerve input, EMS programs around muscle contraction. The unit is an adjustable output source — program, intensity and duration belong to the use plan, not the device.

  • Output, not outcome. The specifications describe what the unit delivers — waveform, frequency range, pulse width, intensity steps — not what a session is expected to achieve.
  • One enclosure, two families. The mode list mixes TENS-type, EMS-type and combination programs; the mode count says how many presets exist, not which family each one belongs to.
  • Presets, not prescriptions. A preset is a stored combination of waveform, frequency and timing. Choosing one is a clinical decision, and two operators can run the same preset at very different intensities.

What do "24 modes" and "40 intensity levels per channel" actually mean?

Twenty-four modes means the unit stores 24 preset programs, each a fixed combination of waveform, frequency and pulse timing. Forty levels means the intensity control has 40 discrete steps on each channel. Neither number describes how the adjustment feels in use: two units can both print "40 levels" and behave very differently at the low end of the range.

What is worth checking on the device itself, rather than on the listing page:

  1. Where the steps sit. Ask for the output range and the step size, then check whether the low steps are distinguishable. A long step count spread unevenly is harder to use than a short count spread evenly.
  2. Independent channel settings. Each channel should hold its own intensity and timer, otherwise "dual channel" collapses into one combined setting with two outlets.
  3. Output lock. Institutional use means the setting has to survive a sleeve brushing the keypad. A keypad lock is a procurement question, not a comfort feature.
  4. Timer resolution. Fixed 15, 30, 45 and 60-minute presets suit standard sessions; minute-level entry matters when a session plan calls for shorter blocks or two blocks back to back.
Term What it describes on the unit What to confirm before release
TENS program Output built around sensory-nerve input, with shorter pulse widths and faster repetition Which program family each preset belongs to, and the frequency and pulse-width range behind it
EMS program Output built around muscle contraction, with longer pulse widths and slower repetition Whether the preset is written for supervised use, and what the manual says about session length
Mode count (24) Number of stored presets, not a measure of capability The program table in the manual, mapped preset by preset
Intensity levels (40) Discrete steps on each channel Output range, step size, and whether the lowest steps are usable in practice
Dual channel Two independent output circuits, four pads Independent intensity, independent timer and independent stop, per channel
Session timer Preset session lengths Fixed presets or minute-level entry, and what happens at the end of a block
Electrode pads Self-adhesive consumable interface between pad and skin Replacement cadence, pad size mix, and the case pack the clinic will reorder in
Safety and EMC evidence The test reports and certification marks the manufacturer holds Model number match between label, manual and report, plus the report version date

Why is dual channel a workflow question, not a spec-sheet question?

Two channels mean two output circuits, so two pad pairs can be placed at the same time — at two sites in one session, or with two operators working in parallel. The specification ends there; the workflow consequences do not.

  • Independent timing. If both channels share one timer, the shorter block sets the pace for both, and the second site either ends early or runs past its planned length.
  • Independent stop. A stop control that drops both channels is the right behaviour in an emergency and awkward in ordinary use. Check which behaviour the unit has; the two are not interchangeable.
  • Fault behaviour. One channel reaching its end, or a pad losing contact, should not silently take the other channel down with it.
  • Room turnover. Two sites in one visit halves the appointments a room has to absorb; two operators in parallel changes the scheduling model, not just the device count.

How often do the electrode pads need replacing, and what drives that?

Self-adhesive pads are a consumable: the conductive layer dries out and picks up skin oils, so adhesion and even current distribution fall away with use rather than with age. A two to four week cycle is a common planning range, but the drivers are sessions per pad, skin condition at the placement site, and storage between uses.

  • Sessions, not calendar time. A pad used five times a week degrades faster than the same pad used twice; count sessions per pad before fixing an interval.
  • Storage. Pads returned to the release film and kept away from heat hold their tack longer than pads left face-up on a tray.
  • Site preparation. Oils, lotions and hair at the placement site reduce contact and push the clinic toward a shorter replacement cycle.
  • Size mix. Round and rectangular pads are used up at different rates, so a replenishment point set on one size will run the other size out first.

For budgeting, multiply pads consumed per unit per month by the number of units, then round up to the case pack. That lands closer to the true annual consumable line than a per-box comparison does.

What should an institutional buyer verify before this unit is released in Canada?

Three checks, in this sequence, because each one can invalidate the others.

  1. Classification and licence status. In Canada a Class II device needs a medical device licence held by the manufacturer. A distributor's establishment licence (MDEL) covers import and distribution activity and does not substitute for the product licence. The model on this page is a Class II device, and the current listing state is a display state — not a statement that the model has been released for supply.
  2. Technical file and label consistency. The model number has to be the same string on the label, in the manual and on the test reports. Mismatches here are the most frequent reason a file stalls, and they are cheap to catch early.
  3. Electrical safety and EMC evidence, current version. The Canadian references are CAN/CSA-C22.2 No. 60601-1, the Canadian adoption of IEC 60601-1, and CAN/CSA-C22.2 No. 60601-1-2 for electromagnetic disturbances, with the mark on the label matching the certificate. Ask for the report with a date and a scope that names the model — not a brochure line saying the unit is certified.

Commercial information only becomes meaningful after those three. Reversing that sequence — agreeing terms first and chasing documents afterwards — is where release schedules are lost.