CliniEco 24-Hour Biological Indicator Incubator — Precision Dry-Block, 24 Wells
Prefer a quote? B2B & facility pricing — bulk discounts and standing orders on request. We reply within 1 business day.
Which biological indicator vials seat properly in this dry block?
The block is machined with twenty-four wells of eight point eight millimetres across, cut to the outside diameter of a self-contained spore ampoule, so a standard tube drops in flush and the aluminium wall carries heat the whole length of the vial. A wider cap will not enter the well at all, and an undersized tube sits loose with an air gap around it, which is the usual reason one indicator in a batch reads late. Anything used here has to be read at 56 to 60 degrees C, the growth band for Geobacillus stearothermophilus; the 24-hour spore test ampoules match that well format and that temperature window.
| Property | Value |
|---|---|
| Type | Dry-block biological indicator incubator, 24-hour read |
| Temperature zone | 56–60 °C, held to ±0.5 °C |
| Wells | 24, machined aluminium block |
| Well diameter | 8.8 mm, matched to standard spore ampoules |
| Vial compatibility | Self-contained ampoules, G. stearothermophilus ATCC 7953 |
| Records | LCD temperature display with USB data export |
| Power | 100–240 V AC external adapter, 50/60 Hz |
| Sold as | One bench unit, not a case pack |
| SKU | CLI-INC-24 |
| Warranty | Two years |
Is one unit the right order, or does a clinic buy a case of them?
A case pack does not exist for this device: it leaves as a single bench unit with its external adapter, so the SKU on the invoice is one machine and a busy office usually stops there. The reprocessing bench is where incubation happens, not each operatory, so four chairs sharing one sterilizer need one block and a second one only when a second sterilizer sits in another suite. Buying two units for redundancy sounds prudent until both sit half full and neither is ever the one an auditor asks to see.
How many wells does a three-sterilizer office fill in a working week?
Count one well per sterilizer per day it is run. Three sterilizers across a five-day week is fifteen wells, a six-day week is eighteen, and a 24-well block still holds six seats for the re-test that follows a failed indicator and for the extra run after a holiday closure. That spare room is the practical reason the block is sized above a single day's load: a failure on Friday afternoon cannot wait for Monday if the block is already full. Offices that want a same-shift answer pair this block with a rapid reader, or step down to a one-hour readout indicator and read it in the reader at the bench.
Print the daily record sheet from the spore log and record centre, work out how many indicators a week of clinics consumes with the sterilizer run planner, and put a procedure question to the sterilization compliance desk. Districts consolidating several sites order through the wholesale desk.
Distributed in Canada by CliniEco Medical, Toronto, under MDEL #35334.
CliniEco 24-Hour Biological Indicator Incubator
Daily sterilization monitoring made simple — audit-ready for Ontario dental clinics
Why Your Clinic Needs This
Ontario regulations (RCDSO/PHO) require DAILY biological monitoring of sterilizers. Our 24-hour incubator gives you reliable, in-office spore testing with precision temperature control — at a fraction of the cost of major brands.
🛡️ Built to Clinical Standards — Inside This Incubator
🌡️ ±0.5°C Precision Heating
PID-controlled dry-block heating element with NTC temperature sensor holds a stable 56-60°C incubation zone — critical for accurate BI growth and reliable results.
🔧 Machined Aluminum Block
CNC-machined aluminum heating block with 24 precision wells (φ8.8 mm, matched to standard BI vial outer diameter), ensuring consistent thermal contact across every vial.
⚙️ Industrial-Grade Control
Microcontroller-based temperature control with real-time LCD display and USB data export — audit-ready records for RCDSO inspections.
🔌 Robust Build & Support
100–240 V AC external adapter (50/60 Hz), 2-year warranty, Toronto-based support with Canadian distribution under MDEL #35334.
Specifications
| Type | Dry-block biological indicator incubator (24h) |
| Temperature | 56-60°C (±0.5°C precision) |
| Wells | 24 wells (φ8.8 mm, matched to standard BI vial diameter) |
| Compatibility | Self-contained BI ampoules (G. stearothermophilus ATCC 7953) |
| Display | LCD temperature display |
| Data | USB data export (optional record software) |
| Power | 100-240V AC 50/60Hz |
| Certifications | |
| Warranty | 2-year warranty |
Why CliniEco
- Precision: ±0.5 °C dry-block control held across all 24 wells
- No lock-in: works with any standard 56-60 °C BI ampoules
- Audit-ready: pair with our free printable record sheets
- Made for Canada: 110V/60Hz, EN/FR labeling, Toronto-based support
Sold on its own
Our 24-hour indicators start at $2.80 each in the 25-pack, and the price per strip drops as the pack size goes up.
Shop the 25-packRelated Guides
Learn how to choose and use this product correctly:
Have a question about your own facility? Send it in and you will get a written answer specific to your setup, with the regulation or standard it is based on cited. Ask your compliance question.
Related tests in this BI line
- DLAB HB105-S1 Dry-Bath Incubator with Lid — 20 wells, $599.00
- Clinic Starter Bundle — Gloves, Spore Testing & Sterilization Packaging
- CliniEco Medical Biological Indicator — 1-Hour Rapid Readout, Fluorescence, 50-Pack
- CliniEco Medical Biological Indicator — 20-Minute Rapid Readout, Fluorescence, 50-Pack
- CliniEco Medical Biological Indicator — 24-Hour Self-Contained, 100-Pack
- CliniEco Medical Biological Indicator — 24-Hour Self-Contained, 25-Pack
- CliniEco Medical Biological Indicator — 24-Hour Self-Contained, 50-Pack
- CliniEco Medical Biological Indicator — 3-Hour Rapid Readout, Fluorescence, 50-Pack
- CliniEco Medical Bowie-Dick Test Pack — ISO 11140-5 Type 2, Daily Vacuum Check, 6-Pack
- CliniEco Rapid Reader — 4-Well Fluorescence Biological Indicator Reader
Related articles
- 24-Hour Self-Contained Biological Indicators: Pack Sizes, Incubation and the Record
- How Often Must US vs Canadian Clinics Run Sterilizer Testing? 24-Hour Biological Indicator Incubator Ordering
- Which Standards Apply to Medical Biological Indicator in the US vs Canada? Sizes and Sourcing
- Which Standards Apply to HB105-S1 Dry Bath Incubator with Lid in the US vs Canada? Sizes and Sourcing