Wound Dressing Selector and Change Record

This selector takes three things a wound round already knows — how much a wound is draining, what kind of wound it is, and how often it is redressed — and returns the layer combination that belongs on it, the number of sterile gauze sponges and rolls of tape a month of that round consumes, and what those consumables cost at the prices this store is showing today. It is written for nurses and personal support workers running dressing rounds in long-term care, retirement homes, clinics and home care across Ontario, and it covers the non-advanced dressing formats we stock: sterile gauze, self-adhesive foam, silver foam, elastic wrap and fixation tape.

Work out what a dressing round consumes

Nothing is submitted and nothing is stored. Gauze and tape prices are read from this store when the page loads, so the monthly figure follows a price change instead of going stale.

Gauze counts assume one sterile sponge for low drainage, two for moderate and three for high, opened at the time of use and never decanted in advance. A roll of 1 inch x 10 yard paper tape carries about thirty changes at two strips per change.

How do you choose a dressing by exudate level?

Exudate volume is the one variable that decides the format, because it decides what the dressing has to do. A dry or barely marked wound needs a dressing that will not stick to the bed and will not macerate the skin around it, so the contact layer does the work and the cover is there to hold it in place. A moderately draining wound needs a contact layer plus somewhere for the fluid to go, which is what an absorbent cover provides. A heavily draining wound needs the absorbent capacity to be inside the dressing rather than in the number of gauze sponges stacked on top of it, and it needs the change interval set by saturation rather than by the day of the week. Stacking sponges to get through a longer interval is the most common error we see in dressing rounds: it lifts the dressing off the bed, it traps fluid against the surrounding skin and it produces a dressing that looks adequate from the outside while the wound underneath is sitting wet.

Exudate level What it looks like on the dressing Contact layer, what touches the bed Cover layer and fixation
None to low Dry, or a spot mark smaller than a coin One sterile gauze sponge Self-adhesive foam dressing, no tape on skin
Low to moderate Marked through, not saturated at the edges Two sterile gauze sponges, or one 12-ply pad Self-adhesive foam dressing; tape only if the border lifts
Moderate to high Saturated within the interval, edges wet Three sterile gauze sponges, changed more often Absorbent foam, secured with hypoallergenic paper tape
High, with a cavity Strike-through to the outer layer Packing or a cavity filler, then gauze over it Silver foam dressing plus a secondary absorbent pad

The working figure: a single wound redressed twice a week takes 104 changes a year, so the difference between a change built from one gauze sponge and a change built from three is about 208 extra sponges a year — a little over one 200-count box — which is the cost of stacking rather than of the dressing.

What is a contact layer, and why does it decide the choice?

The contact layer is whatever is physically against the wound bed, and it is the only part of the dressing the wound actually feels. Everything above it exists to hold fluid or to hold position. Get the contact layer right and the cover is a logistics decision; get it wrong and no amount of absorbent padding fixes the result. In our range the contact layer is a sterile gauze sponge in most rounds, which is why gauze is the item that disappears fastest from a supply room and the item most often ordered late. The reason the sponge must come out of a wrapper that is opened at the time of use is that the wrapper, not the sponge, is the sterile barrier: a wrapper crushed in a drawer, dampened on a trolley or opened early and left sitting has stopped being a barrier whatever the sponge inside it was when it was packed. One sponge, one wrapper, one patient is a supply discipline as much as an infection control one, and it is the reason the 200-count box is the unit that rotates rather than a handful decanted into a dish at the start of a list.

How often should a dressing be changed?

The interval is set by the exudate level and by the facility's own protocol, not by a fixed number of days, and the two numbers that matter are how quickly the dressing saturates and whether the surrounding skin is holding up. A dressing that has struck through has already failed as a barrier and should have been changed before that point; a dressing that comes off clean with intact surrounding skin after several days is telling you the interval can stay where it is. What we would push back on is an interval written into a standing order without a saturation clause attached, because the same wound in two residents can behave differently and the round needs permission to shorten the interval when it sees strike-through. The frequency input above exists for exactly this reason: doubling the changes per week doubles the consumables, and a facility that adds a mid-week check to reduce the number of strike-throughs often ends up spending less on covers than it spends on the extra changes.

Why is the price per dressing the wrong number to compare?

Because pack counts differ and nobody divides. A foam dressing sold as a box and a foam dressing sold singly carry prices that cannot be compared until both are reduced to a cost per piece, and a quote that gives you a box price without a piece count is not a price yet. That is why the calculator above costs the round in sterile gauze and tape, where the units are fixed and verifiable — 200 sponges to a box, twenty rolls to a pack, roughly thirty changes to a roll — and treats the cover dressing as the item you choose from the list on the product page. The second reason is that the cover is not the item that runs out. In most rounds the tape and the gauze are what send someone to the supply room, and a supply list built around the cover dressing will keep reordering the expensive item while running dry on the cheap ones. If you are assembling a round from scratch, the order that avoids a mid-week resupply is gauze, tape, covers, then wraps.

Can you print a dressing change record?

Yes. The button above prints the calculation, and the record below prints as a blank form you can carry on the round. A record that survives an audit is one that captures, for every change, the date and time, the site and the layers applied, what the exudate looked like and what the surrounding skin looked like, and who did it. Four columns is enough for that if the entries are written in the round rather than reconstructed at the end of the shift, and a record reconstructed afterwards is worth very little when a wound deteriorates and someone asks to see the sequence.

Date and time Site and layers applied Exudate and surrounding skin Initials
       
       
       
       
       
       
       
       

What this page is not

It is not a wound assessment and it does not choose a dressing for you. Deciding whether a wound needs debridement, whether the surrounding skin is macerated, whether a wound has become infected and needs to be seen by a clinician, and which product is appropriate for a particular wound are clinical judgments that belong to the nurse or physician assessing the patient, working from their own college standards and their facility's policy. The products on this page are non-advanced dressing formats for routine wound care; they are not a substitute for an assessment, and a wound that is not progressing, is becoming more painful, or is draining more rather than less should be escalated rather than redressed with a different pad. What this page does is the arithmetic that follows the clinical decision: how many pieces, how many boxes, how many rolls, and what that costs a month at today's prices.

What if the quantities still do not match the shelf?

Then the shelf is the truth and this page is the estimate. Take one month of actual draw-down from the supply room, divide by the number of changes the round recorded, and you will get your facility's real consumption per change, which is usually higher than the assumption here because of waste at the start of a list and because of the second sponge that gets opened when the first is dropped. Build the par level on that number, add a margin for the week when two residents are on daily changes, and re-check it when the product format changes, because moving from gauze and tape to a self-adhesive foam changes the consumption pattern of three items at once. If you would rather have the round costed against your actual product mix, send the change frequency and the formats you use through the account request form and the quantities come back with the case sizes that cover them.