INTCO Gloves Canada

INTCO nitrile gloves sold to Canadian clinics as a case of ten boxes — twelve size and grade variants across two lines, and one case listing that holds them all. This page is written from what is inside the collection rather than from the brand name: a buyer arrives here knowing the brand and needs to know which grade, which weight and which size mix to put on the order. The case, the grade difference and the standards behind the box are set out below.

1 product
More about INTCO Gloves Canada

What is actually in this INTCO collection, and how is a case built?

One case listing — INTCO nitrile gloves, Touch Flex and Advancare, 1,000 per case — carries twelve variants. Every variant is a full case of ten boxes of one hundred gloves, so the unit you receive is 1,000 gloves in one size, and the size is a property of the variant rather than of the carton.

INTCO case listing: line, grade, colour and sizes available
Line and grade Colour Sizes Case build
Touch Flex 3.5 g, non-exam Blue S, M, L, XL 10 boxes × 100 gloves = 1,000
Touch Flex 3.5 g, non-exam Black S, M, L, XL 10 boxes × 100 gloves = 1,000
Advancare 3.5 g, exam grade Blue S, M, L, XL 10 boxes × 100 gloves = 1,000

Two further listings sit in the same collection as single-box offerings and are not published at the time of writing, so they are not linked here: a 6 mil Touch Flex examination glove in a 100-count box, and a 4 mil Touch Flex examination glove in a 100-count box. Until those are live, the case listing is the only orderable route into this collection, and a clinic that wants one box rather than ten has no published option inside it. That is a membership question for the store, not a question about the glove.

What does ASTM D6319 actually test, and what does it leave to other documents?

ASTM D6319 is the specification for nitrile examination gloves used in medical examinations and diagnostic and therapeutic procedures; the current edition is D6319-19(2023). It covers freedom from holes, physical requirements before and after ageing, the amount of powder on the glove, tensile strength and elongation at break, and it is written to parallel D3578, the equivalent specification for rubber examination gloves.

What it does not do is tell a buyer how thick a glove feels. Weight in grams and thickness in mil are properties a manufacturer states, not properties the specification grades for comfort; the specification grades performance. A 3.5 g glove and a 6 mil glove can both be conforming nitrile examination gloves, and they are not the same glove in the hand. That is why the grade and the weight belong on the purchase order next to the size.

The international counterpart is ISO 11193-1:2020, which covers single-use medical examination gloves made from rubber latex or rubber solution and is the document a supplier outside North America is more likely to declare. Both routes exist, and a Canadian buyer comparing two quotes should ask which one is being declared rather than assume the two are interchangeable paperwork.

Exam grade or non-exam grade: what is the difference on the box?

Exam grade is the version tested for use in examinations and procedures. Non-exam grade is a utility glove: same nitrile, less demanding performance requirements, and labelled as non-exam because it is not intended for patient examination contact. Both appear in this collection, and the two colours map onto the two grades — the Touch Flex non-exam line in blue and black, the Advancare line in blue as the exam-grade option.

The buying decision is a task decision. A glove worn to handle a carton, change a liner or wipe a surface does not need exam-grade performance, and paying for it in every room is a running cost. A glove worn for a pelvic exam, a wound check or any procedure with mucosal contact is the case the exam specification exists for. The failure mode is not buying the wrong glove by accident; it is standardising on one grade everywhere because two stock lines are inconvenient, and then either over-specifying the utility task or under-specifying the clinical one.

How do you split sizes across a clinic, and what does a case actually cover?

A case is 1,000 gloves in one size. For a clinic that means the size mix is the decision, and the mix follows roles rather than headcount: the sizes used at the chair or the bedside dominate, while support and administrative staff pull from the middle of the range. Ordering four cases in equal quantities is the common first mistake, because it leaves the largest and smallest sizes expiring on the shelf while the middle size runs out.

A workable start is to count a week of empty boxes by size, then convert that count to whole cases. One box is 100 gloves, so a station that opens two boxes a week consumes roughly one case every five weeks, and the reorder point is a function of lead time rather than of shelf space. Keeping the count in boxes and buying in cases also gives a clean arithmetic check on delivery: ten boxes per case, one hundred gloves per box.

Does a glove carton sold in Canada differ from the one sold in the United States?

Yes, in two fields that matter at the loading dock. A glove sold in Canada carries labelling in both English and French, and the distributor's Medical Device Establishment Licence number (CliniEco Medical: MDEL #35334) is the identifier a clinic file records. A carton built for the United States carries English labelling and points to a listing under 21 CFR 880.6250, and the powdered-glove content question is settled by the American ban rather than by the Canadian listing.

Because the glove inside can be identical, the carton is the only place the difference shows. A buyer comparing two quotes across the border should compare the label language and the declared standard, not the glove.

What should be printed on the box when the delivery arrives?

Five fields: the size, the grade, the lot number, the expiry date, and the standard the glove is declared against. A nitrile examination glove sold in Canada also carries bilingual labelling, so both languages should appear on the carton. The size on the box has to match the size on the purchase order and on the case label, because a mislabelled inner box is discovered at the worst moment — mid-procedure, with a glove that does not fit.

Record the lot number against the delivery date. If a batch later turns out to have a defect, the lot is the only field that ties the box in the cupboard to the box in the bin, and an invoice number will not do it.

How does Canada regulate examination gloves compared with the United States?

Gloves are a good example of two systems reaching the same product by different routes. In the United States a patient examination glove sits under 21 CFR 880.6250, and most examination gloves are exempt from premarket notification, so the compliance weight sits in establishment registration and device listing. In Canada a glove is a licensed device and the establishment that distributes it holds a Medical Device Establishment Licence (CliniEco Medical: MDEL #35334).

Examination gloves: Canada and the United States compared
Item Canada United States
Classification route Licensed device under the Medical Devices Regulations; distributor holds an MDEL (CliniEco Medical: MDEL #35334) 21 CFR 880.6250, non-powdered patient examination glove
Premarket Device licence held before the product is sold Most examination gloves exempt from premarket notification; establishment registration and device listing apply
Nitrile standard ASTM D6319-19(2023) or ISO 11193-1:2020, as declared by the supplier ASTM D6319-19(2023), recognised by FDA in part
Powdered gloves Check the supplier's declaration against the current listing Powdered patient examination gloves are subject to an FDA ban, and the powdered-glove text is excluded from FDA's recognition of D6319
Labelling English and French English

The powdered row is the one that matters most when a buyer compares a Canadian and an American quote for what looks like the same carton. FDA's recognition of ASTM D6319 is partial, and the excluded text is exactly the text about powdered gloves, because powdered patient examination gloves were banned in the United States. A specification that cites D6319 without naming the edition therefore does not, on its own, say whether powder is part of the product.

Related reading

Background on the standard and on glove selection: what ASTM D6319 covers, nitrile examination gloves compared with surgical gloves, and how heat and ozone affect nitrile glove tensile retention.

Frequently asked questions

Is every glove in this collection an examination glove?

No. The Touch Flex 3.5 g line is labelled non-exam, and the Advancare line is the exam-grade option. Both are nitrile, and the grade on the box decides which tasks the glove is intended for.

How many gloves are in one case?

One thousand: ten boxes of one hundred, all in the same size. The variant you select is the size, so a four-size order across a clinic is four cases, not one mixed case.

Does the glove weight tell me the thickness?

Not directly. Weight in grams and thickness in mil are separate measurements, and a supplier may state one, the other, or both. Ask for the measurement the specification in use actually references.

Why does FDA recognise ASTM D6319 only in part?

Because powdered patient examination gloves are banned in the United States, so the powdered-glove text in the standard is excluded from FDA's recognition. The rest of the specification is recognised for premarket submissions.

Where does a clinic or group order gloves in case quantities?

The clinic supply planner converts clinical days into whole cases, the compliance log centre holds the printable records, and multi-site accounts start at the institutional account enquiry page.

Standards and sources

Editions and links were checked on 6 November 2026. ASTM D6319-19(2023), standard specification for nitrile examination gloves for medical application; FDA recognition record for ASTM D6319-19(2023), including the partial-recognition note on powdered gloves; 21 CFR 880.6250, non-powdered patient examination glove; ISO 11193-1:2020, single-use medical examination gloves; Health Canada, medical devices. The ASTM and ISO catalogue pages refuse automated requests; both entries were read from their catalogue records and are cited with edition dates.

Distribution: CliniEco Medical — MDEL #35334. Case builds and variants are those printed on the current product listing; confirm the grade and the size mix against the tasks the glove is bought for.