Specimen Transport Compliance: TDG Rules for Canadian Clinics

Every day, Canadian clinics hand couriers parcels of blood, urine, swabs and other patient samples. When a shipment leaks or goes missing, Transport Canada holds the clinic responsible. The Transportation of Dangerous Goods (TDG) Regulations define how clinical specimens must be packaged, labelled and documented before they leave your door.

If your staff ships patient samples by courier, bus or air, specimen transport sits under the TDG Regulations, with the UN3373 framework at its core. Knowing the rules protects patients, staff and your standing with regulators.

Buying specimen bags? Distributed in Canada by CliniEco Medical, Toronto.

CliniEco Leak-Proof Sample Cups  ·  CliniEco Medical Specimen Transport Bags  ·  CliniEco Medical UN3373 Specimen Transport Bags  ·  Wholesale & clinic accounts

Quick facts: TDG for clinic specimens

  • Offer a specimen to a carrier and you are the consignor — the TDG Regulations apply to the clinic, not to the courier.
  • Routine blood, urine and swabs travel as UN3373, Biological Substance, Category B; Category A (UN2814 or UN2900) is the high-risk class with a stricter package.
  • Triple packaging is the core requirement: leak-proof primary, 95 kPa-tested secondary with absorbent material, rigid outer.
  • Training certificates are renewed every three years, and an untrained packer is a finding on its own.
  • CliniEco Medical is a licensed medical device establishment (MDEL #35334) and stocks 95 kPa specimen bags and 3-wall transport bags.

What Is TDG and When Does It Apply to Your Clinic?

TDG refers to the Transportation of Dangerous Goods Regulations, administered by Transport Canada. They govern dangerous goods — including infectious substances — moved by road, rail, air and marine within Canada. For clinics, the trigger is simple: offer a diagnostic specimen to a carrier, and you are a consignor.

Exemptions cover small quantities carried in a patient's own vehicle and some samples sent between health care settings where risk is judged minimal. most routine clinic-to-laboratory shipments fall under the regulations. When in doubt, classify as dangerous goods — a leak that exposes a courier costs more than a compliant package.

UN3373: Biological Substance, Category B

Most routine clinical specimens — blood draws, urine samples, nasal and throat swabs — are assigned to UN3373, Biological Substance, Category B, used when exposure is unlikely to cause disease. Category A (UN2814 or UN2900) covers pathogens that can cause permanent disability or life-threatening disease and demands a stricter packaging standard.

For most Canadian clinics, UN3373 is the classification you will use. It drives everything downstream: packaging, labelling, documentation and staff training.

Packaging Requirements: Triple Packaging and 95 kPa Tested Bags

TDG requires a triple packaging system for UN3373 shipments. Three layers, each with a distinct job:

  • Primary receptacle: the leak-proof tube, vial or container holding the specimen.
  • Secondary packaging: a second leak-proof layer protecting the primary receptacle — usually a 95 kPa specimen bag that passed the 95 kPa pressure test.
  • Outer packaging: a rigid box, mailer or courier envelope shielding the inner layers during transit.

Absorbent material must sit between the primary and secondary packaging — enough to soak up the full contents if the primary leaks. The CliniEco Medical specimen bags are 95 kPa leak-proof tested, with a clear pocket for the UN3373 label and documentation — the most common compliance item we supply and the least expensive insurance you will carry.

CliniEco 95 kPa specimen bags

Labelling Your Shipment

Every UN3373 shipment must carry the diamond-shaped Category B label — white, with the UN3373 mark in the centre — on the outer packaging, with the shipper's name, address and a 24-hour emergency contact number.

Air transport adds a layer: IATA's Packing Instruction 650 requires the shipper's declaration attached to the airway bill. Ground couriers in Canada follow the TDG Regulations under Transport Canada, which for most clinic shipments demand the UN3373 mark and documentation rather than a full dangerous goods declaration.

Training Requirements for Clinic Staff

TDG training is not optional. Any employee who handles, offers for transport or transports dangerous goods — including UN3373 specimens — must be trained and certified. That includes the receptionist packaging a urine sample and the nurse handing a cooler to a courier.

Training must cover classification, packaging, labelling and emergency response, renewed every three years or whenever the regulations change. Transport Canada audits consignors — an untrained employee is a finding waiting to happen. Document every session; the certificate is your evidence.

Safe handling also means protecting collectors, and the absorbent pad inside the secondary layer is the part that decides whether a cracked primary becomes a wet parcel or a contained one. A 6 × 9 inch three-wall bag carries an inner absorbent layer, the main bag and an outer document pouch in one item, which is why it is the bag most ground shipments leave in.

Common Clinic Mistakes (and How to Avoid Them)

The errors Transport Canada sees most often are preventable:

  • Using a plain zip-lock bag as secondary packaging. A sandwich bag will not survive the 95 kPa pressure test.
  • Forgetting absorbent material between the primary and secondary layers.
  • Shipping with an expired training certificate.
  • Applying the UN3373 label to the inner bag instead of the outer packaging.
  • Reusing a specimen bag that has been opened or damaged.

One more recurring error: swabs that shed fibres, forcing a redraw and a second shipment. double-tipped cotton swabs from CliniEco remove that variable — one clean collection, one compliant shipment.

CliniEco double tipped cotton swabs

What Does a Compliant UN3373 Package Look Like, Layer by Layer?

Triple packaging is easy to describe and easy to get wrong, because each layer is doing a different job and only one of them is the bag most clinics already own. Read the table as a build order, from the specimen outwards.

Layer What it has to do What we supply for it How it fails
Primary receptacle Hold the specimen without leaking, upright or inverted Graduated leak-proof specimen containers and screw-cap tubes A cracked lid thread or an overfilled cup that weeps at the seal
Absorbent material Take up the full volume of the primary if it breaks Built into the three-wall bag as an inner absorbent layer Absorbent skipped, or a paper towel that holds a fraction of the volume
Secondary packaging Leak-proof and pressure-tested, so a leak stays inside 95 kPa-tested specimen bags, 6 × 9 in through 12 × 15 in A plain zip-lock bag, which has never been pressure-tested
Outer packaging Rigid enough to protect the inner layers in transit Rigid mailer or courier box sized to the bag A soft envelope that lets the secondary bag take the impact
Marking and label UN3373 diamond on the outer surface, shipper details, 24-hour contact Document pouch so the request form does not sit loose Label applied to the inner bag, where nobody loading the van can see it
Documentation Shipper's declaration where the route requires it — Paperwork completed after the parcel has left

The failure mode to notice is the one in the absorbent row. A three-wall bag carries its absorbent layer inside the secondary packaging by construction, which means the decision is made when the bag is bought rather than at the bench at 5:40 PM. Build the package from a plain bag and a paper towel and you have moved the weakest step to the busiest moment of the day.

Which Bag Do You Need: 95 kPa or a 3-Wall Leak-Resistant Bag?

Both bags are legitimate and they answer different routes. The question is not which one is better, it is what happens to the parcel after it leaves your door.

Route Bag Why
Courier or bus between a clinic and a laboratory, ground only 3-wall leak-resistant bag with absorbent pad and document pouch Ground transport under the TDG Regulations is built around leak resistance and absorbency; the 3-wall bag delivers both in one item
Air transport, or any route where IATA Packing Instruction 650 applies 95 kPa-tested specimen bag, 6 × 9 in through 12 × 15 in PI 650 calls for a secondary package that passes the 95 kPa pressure differential, which is a test the 3-wall bag is not certified against
Mixed network where the courier may consolidate to air 95 kPa bag You cannot control the routing decision made downstream, so buy the packaging that survives the stricter leg
In-house transport by staff in a clinic vehicle 3-wall bag inside a rigid secondary container The package still has to contain a leak, and the rigid outer is what protects it in a footwell

The practical rule that follows: if the parcel can ever fly, buy the 95 kPa bag for that workflow and stop maintaining two specifications. The two specifications on the shelf is how a clinic ends up with the 3-wall bag loaded into an air shipment because it was the one within reach.

Related Reading

Explore more guides in this category:

Frequently Asked Questions

Do I need TDG training to ship specimens from my clinic?

Yes. Any employee who packages or transports dangerous goods must hold a valid TDG training certificate, renewed every three years — even when a courier picks up the package.

What is the difference between Category A and Category B specimens?

Category A (UN2814 or UN2900) covers pathogens that can cause permanent disability or life-threatening disease. Category B (UN3373) covers specimens unlikely to cause disease — most routine clinical samples such as blood, urine and swabs.

Can I use any plastic bag for specimen transport?

No. The secondary packaging must be leak-proof and pass the 95 kPa pressure test under the TDG Regulations. Standard household bags are not tested and do not meet the standard.

Do the same rules apply for air courier shipments?

Ground shipments follow the TDG Regulations under Transport Canada. Air transport follows IATA's Packing Instruction 650, which requires the UN3373 mark, the Category B label and additional shipper documentation.

Who is responsible if a specimen shipment leaks in transit?

The consignor — the clinic — is responsible under the TDG Regulations. Compliant packaging, labelling and staff training are your legal protection as much as your patients'.

Can a 3-wall leak-resistant bag replace a 95 kPa bag for air shipments?

No. The 3-wall bag is built for ground routes, where leak resistance and absorbency are the requirements; an air shipment falls under IATA Packing Instruction 650, which calls for secondary packaging tested to a 95 kPa pressure differential. If a courier network may consolidate your parcel onto a flight, specify the 95 kPa bag for that workflow.

Does the absorbent material have to sit inside the secondary packaging?

Yes — between the primary receptacle and the secondary packaging, and in a quantity that would absorb the entire contents of the primary if it broke. A three-wall bag carries that layer by construction, which is the practical reason it is the default for ground specimen transport. CliniEco Medical is a licensed medical device establishment (MDEL #35334).

Preparing specimen-transport documentation? The printable sterilization log sheet covers the load and package-label fields an audit asks for.

For clinics recording on screen, the sterilization log and package-label generator prints the columns you need.

Checking your specimen packaging against the transport rules? Ask a sterilization compliance specialist how TDG applies to your shipments, with the reference named.

Related reading: see the full dental compliance hub for RCDSO-ready checklists.

see our RCDSO sterilization monitoring guide for the daily BI requirement in Ontario.

Vous travaillez déjà avec des cliniques ? Devenez représentant régional.