{"product_id":"mtc-bio-filtered-200-and-300-microlitre-pipette-tips-sterile-racked","title":"MTC Bio Filtered 200 and 300 microlitre Pipette Tips, Sterile, Racked","description":"\u003cp\u003e\u003cstrong\u003eMTC Bio sterile filtered pipette tips for 200 and 300 microlitre pipettes,\u003c\/strong\u003e with a hydrophobic barrier, 960 tips per pack and 4,800 per case, shipped from North American stock.\u003c\/p\u003e\n\u003cp\u003eA filter does one job: it stops aerosol and liquid travelling between the sample and the pipette barrel. That matters for PCR, for anything that could carry over between samples, and for the pipette itself, because a barrel that has drawn sample is a barrel that has to be serviced. These are filtered 200 and 300 microlitre tips, sterile, racked in 96-position boxes.\u003c\/p\u003e\n\u003ch2\u003eWhat is in a case of filtered tips?\u003c\/h2\u003e\n\u003cp\u003eA pack holds 960 tips in 10 racks of 96, and a case holds five packs, so 4,800 tips in 50 racks. Racks are sealed in a sleeve of ten, so a bench can open one sleeve at a time and keep the rest sterile.\u003c\/p\u003e\n\u003cp\u003eThe case count is the same as the non-filtered version, which makes substitution a price decision rather than a storage decision: the rack footprint does not change when the filter is added.\u003c\/p\u003e\n\u003cp\u003eA sleeve of ten racks is enough for a working week at one plate a day, so a case covers about ten weeks of single-plate work and a bench can reorder on the sleeve rather than the case.\u003c\/p\u003e\n\u003ch2\u003eWhen is a filter required rather than optional?\u003c\/h2\u003e\n\u003cp\u003eFor PCR and qPCR it is effectively required: an aerosol that reaches the barrel will contaminate the next sample, and the resulting band is the kind of false positive that costs a day to chase. For cell work and for any step that handles a clinical sample, a filter protects the operator's pipette as much as the sample.\u003c\/p\u003e\n\u003cp\u003eFor clean reagent transfer with a single stock solution, a non-filtered tip is adequate and cheaper. The decision is about carryover risk, not about tip quality: the same manufacturer makes both, and the filter is the variable.\u003c\/p\u003e\n\u003cp\u003eThere is also a service argument for the filter: a pipette barrel that has drawn sample needs a service visit, and the downtime usually costs more than a year of filtered tips for the same bench.\u003c\/p\u003e\n\u003ch2\u003eWhat are the specifications of the filtered 200 microlitre tip?\u003c\/h2\u003e\n\u003cp\u003eEvery configuration below is a separate case line. The manufacturer reference is what appears on the quotation, the packing slip and the lot documentation, so quote it when you ask for a certificate of analysis.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eManufacturer reference\u003c\/th\u003e\n\u003cth\u003ePack\u003c\/th\u003e\n\u003cth\u003eCase\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003ePipette Tips · Filtered · 300µL capacity · sterile · for 200µL and 300\u003c\/td\u003e\n\u003ctd\u003eP4300-FT\u003c\/td\u003e\n\u003ctd\u003e960 per pack\u003c\/td\u003e\n\u003ctd\u003e4,800 per case\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHow many filtered tips does a PCR lab use?\u003c\/h2\u003e\n\u003cp\u003eA lab running four 96-well plates a week with a fresh tip per well uses 384 tips a week, about 1,650 a month, so a 4,800-tip case lasts three months. Where tips are changed between reagents in the same well, consumption rises two to three times.\u003c\/p\u003e\n\u003cp\u003eBecause filtered tips cost more per tip than standard ones, most labs use them for the PCR bench only and keep standard tips for reagent handling: two racks of filtered tips and a case of standard tips is the usual split.\u003c\/p\u003e\n\u003cp\u003eWhere a lab runs both PCR and clean reagent work, the filter cost belongs to the PCR line in the budget, not to the tips line: keeping the two counts separate is what makes the filtered tip spend visible.\u003c\/p\u003e\n\u003cp\u003eA bench that runs plates twice a week rather than daily should size against the week, not the year, because racks take shelf space either way.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eWorking pattern\u003c\/th\u003e\n\u003cth\u003eUsed per month\u003c\/th\u003e\n\u003cth\u003eCase covers\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne bench, light use\u003c\/td\u003e\n\u003ctd\u003eabout 300 pieces\u003c\/td\u003e\n\u003ctd\u003eroughly 8 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne bench, full shift\u003c\/td\u003e\n\u003ctd\u003eabout 2,000 pieces\u003c\/td\u003e\n\u003ctd\u003eroughly 2 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwo benches\u003c\/td\u003e\n\u003ctd\u003eabout 4,000 pieces\u003c\/td\u003e\n\u003ctd\u003eunder one month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCounts above are planning figures from pack and case sizes on this page, not a forecast of your own consumption; check them against a week of your own bench records before setting a reorder point.\u003c\/p\u003e\n\u003ch2\u003eHow is it shipped, and what should you check on arrival?\u003c\/h2\u003e\n\u003cp\u003eTips ship from North American stock, 1 to 2 business days in Ontario, 2 to 4 across Canada, 2 to 3 to US addresses. Racks are sealed and the case label carries the manufacturer reference and lot.\u003c\/p\u003e\n\u003cp\u003eCheck that the filter sits at the collar and is not pushed into the tip: a filter that has moved will reduce the volume a tip can hold, and it is the one defect that is visible before use.\u003c\/p\u003e\n\u003cp\u003eIf a rack has been opened and left on the bench for a week, treat it as non-sterile for PCR and start a sealed rack for the next plate run.\u003c\/p\u003e\n\u003cp\u003eFiltered racks are also the item a shared bench borrows most often, so keep one rack in a marked sleeve per bench rather than a single open rack for the room.\u003c\/p\u003e\n\u003ch2\u003eWhat we do not claim\u003c\/h2\u003e\n\u003cp\u003eSingle-use laboratory consumables for pipetting. Not sold as medical devices for patient treatment. Filter presence, sterility and orifice size are the manufacturer's stated values; the tip is not a calibrated measuring device.\u003c\/p\u003e\n\u003cp\u003eWhat we cannot do is certify a filter for a specific aerosol challenge: send the application and we will check the manufacturer's documentation rather than assume a barrier is absolute.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eHow many tips per case?\u003c\/summary\u003e\u003cp\u003e960 tips per pack in 10 racks of 96, five packs per case, so 4,800 tips in 50 racks.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat does the filter stop?\u003c\/summary\u003e\u003cp\u003eA hydrophobic barrier that prevents aerosol and liquid from reaching the pipette barrel; it is not a sterile filter for the sample itself.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eDo filtered tips fit the same pipettes as standard tips?\u003c\/summary\u003e\u003cp\u003eThey are made for the same 200 and 300 microlitre pipettes; the filter changes the internal volume slightly, so check the low end of the range if your protocol uses volumes under 10 microlitres.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eAre they sterile?\u003c\/summary\u003e\u003cp\u003eYes, this configuration is sterile and racked; the rack is sealed until opened.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I use filtered tips for cell culture?\u003c\/summary\u003e\u003cp\u003eYes, and they are the usual choice where carryover between samples would be a problem; confirm the sterility on the lot documentation for your quality file.\u003c\/p\u003e\u003c\/details\u003e\n\u003ch2\u003eChoosing the right option\u003c\/h2\u003e\u003cp\u003eRelated products in the same laboratory line:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/clinieco-cli-tip-200-std-n-pipette-tips\"\u003eclinieco cli tip 200 std n pipette tips\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/mtc-bio-sureseal-s-1-5ml-sterile-microcentrifuge-tubes-500-pack\"\u003emtc bio sureseal s 1 5ml sterile microcentrifuge tubes 500 pack\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eBackground reading before you order:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/blogs\/medical-supply-guide\/filtered-low-retention-standard-200-ul-tips\"\u003efiltered low retention standard 200 ul tips\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/products\/clinieco-cli-tip-200-std-n-pipette-tips\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/P4300-FT-2.jpg?v=1795452809\" alt=\"Laboratory consumables\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"MTC Bio","offers":[{"title":"Pipette Tips · Filtered · 300µL capacity · sterile · for 200µL and 300µL p","offer_id":49487127412958,"sku":"CLI-TIP-200-STD-F-P4300-FT","price":799.76,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/P4300-FT-2.jpg?v=1795452809","url":"https:\/\/clinieco.ca\/products\/mtc-bio-filtered-200-and-300-microlitre-pipette-tips-sterile-racked","provider":"CliniEco Medical","version":"1.0","type":"link"}