{"product_id":"soco-prismatic-dental-loupes-5-0x-450mm","title":"SOCO Prismatic Ergonomic Dental Loupes 5.0x — Angled 45°, 450 mm","description":"\u003cstyle\u003e\n.soco-prod{max-width:780px;margin:0 auto;font-family:-apple-system,BlinkMacSystemFont,'Segoe UI',Roboto,sans-serif;color:#111827;line-height:1.65;font-size:16px}\n.soco-prod h2{font-size:20px;color:#123a2f;border-bottom:2px solid #E5E7EB;padding-bottom:8px;margin:32px 0 12px}\n.soco-prod h3{font-size:17px;color:#206270;margin:24px 0 8px}\n.soco-prod p{margin:0 0 12px}\n.soco-prod ul{margin:0 0 14px;padding-left:20px}\n.soco-prod li{margin-bottom:8px}\n.soco-prod img{max-width:100%;height:auto;border-radius:10px;display:block;margin:14px 0}\n.soco-prod table{width:100%;border-collapse:collapse;margin:14px 0;font-size:14.5px}\n.soco-prod th{background:#123a2f;color:#ffffff;text-align:left;padding:10px 12px;border:1px solid #123a2f;font-weight:600}\n.soco-prod td{border:1px solid #E5E7EB;padding:10px 12px;vertical-align:top}\n.soco-prod tbody td:first-child{background:#F9FAFB;font-weight:600}\n.soco-note{background:#FFF7ED;border:1px solid #FDBA74;border-radius:8px;padding:14px 16px;font-size:14.5px;color:#7C2D12;margin:16px 0}\n.soco-meta{font-size:14px;color:#4B5563}\n@media (max-width:600px){.soco-prod{font-size:15.5px}.soco-prod h2{font-size:18px}.soco-prod table{font-size:13.5px}.soco-prod th,.soco-prod td{padding:8px 9px}}\n\u003c\/style\u003e\n\u003cdiv class=\"soco-prod\"\u003e\n\n\u003cp\u003eSOCO 5.0x prismatic dental loupes deliver a 60 mm field and 70 mm of depth of field through a 45° angled path in a 66 g fixed frame — the power at which a tooth becomes a surface you inspect rather than an object you survey. Five power is a deliberate narrowing: you give up the whole-tooth view and buy resolution in the hundredths of a millimetre where margins, canal walls and hairline cracks live.\u003c\/p\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/SOCO-SCE300-50-450.jpg?v=1795235341\" alt=\"SOCO SCE300-50-450 prismatic dental loupes, 5.0x, 45-degree angled optical path, fixed frame with adjustable pupillary distance\" width=\"600\" height=\"600\" loading=\"lazy\"\u003e\n\n\u003ch2\u003eWhat are SOCO 5.0x prismatic dental loupes?\u003c\/h2\u003e\n\u003cp\u003eA Keplerian prism system in a sealed barrel, set at 45° to the line of sight, mounted on a fixed non-flip frame. The listing publishes 5.0× magnification, 60 mm of field at 450 mm, 70 mm of depth of field, 66 g net weight, pupillary distance adjustable from 50 mm to 80 mm, and a working distance of 450 mm as standard, built anywhere from 400 mm to 580 mm.\u003c\/p\u003e\n\u003cp\u003eThose numbers describe a specific instrument rather than a general upgrade. The field is exactly one prepared tooth at a comfortable distance; the depth of field is roughly the height of a crown plus a couple of millimetres. Everything about the pair assumes the operator intends to work in one place for minutes at a time.\u003c\/p\u003e\n\n\u003ch2\u003eWhy is 5.0x usually a second pair rather than a first?\u003c\/h2\u003e\n\u003cp\u003eBecause a working day is not made of one kind of task. Sixty millimetres of field is excellent for a margin and awkward for a quadrant check, and a clinician doing a full-mouth series or a hygiene appointment at 5.0× spends the appointment moving. Most owners of a 5.0× pair keep a wider instrument — a 2.5× or 3.5× Galilean, or a 4.0× prismatic — for the parts of the day that need breadth, and reach for this one when the deciding factor is whether a feature is visible at all.\u003c\/p\u003e\n\u003cp\u003eThat is also the honest commercial picture: this pair earns its place against a specific case mix. A practice with a high endodontic retreatment load, or one doing micro-restorative and veneer margin work, will use it weekly. A hygiene-led or high-volume restorative practice may find that 4.0× covers the same procedures with less refocusing.\u003c\/p\u003e\n\n\u003ch2\u003eWhat do the published specifications say?\u003c\/h2\u003e\n\u003cp\u003eAll values are from this listing; where another surface of the listing states a different figure, the specification card is the surface quoted here.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003eValue on this listing\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnification\u003c\/td\u003e\n\u003ctd\u003e5.0×\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of view\u003c\/td\u003e\n\u003ctd\u003e60 mm at 450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking distance\u003c\/td\u003e\n\u003ctd\u003e450 mm standard; 400–580 mm built to order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e66 g net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePupillary distance\u003c\/td\u003e\n\u003ctd\u003e50–80 mm, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeadlight\u003c\/td\u003e\n\u003ctd\u003eOptional SCML05 coaxial LED, bayonet clip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe optical path is angled 45° downward, the mount is fixed and does not flip, and the depth of field is published at 70 mm.\u003c\/p\u003e\n\n\u003ch2\u003eHow does a 60 mm field change the way a case runs?\u003c\/h2\u003e\n\u003cp\u003eIt turns a procedure into a series of stations. You establish the outline at a wider power or with the naked eye, then move into 5.0× for the part that needs it: the gingival seat, the proximal box, the margin of an existing crown. Between stations you re-establish orientation rather than scanning, and the patient's head position does most of the travelling.\u003c\/p\u003e\n\u003cp\u003eThe practical consequence is that chairside time per quadrant rises while rework falls. That is a trade clinicians make willingly for endodontic access and margin refinement, and reluctantly for anything where speed is the priority. Knowing which of your procedures falls on which side of that line is the actual buying decision.\u003c\/p\u003e\n\n\u003ch2\u003eIs 5.0x the right power for retreatment?\u003c\/h2\u003e\n\u003cp\u003eOften yes, and the reason is anatomical. Separated instruments, isthmuses between two canals, perforation repairs and the removal of a post all require seeing a feature that is smaller than the resolution of a 3.5× Galilean system at the edge of its field. Five power puts those features inside a stable image without going to the narrow end of the range, where a 50 mm field makes orientation harder than the work itself.\u003c\/p\u003e\n\u003cp\u003eThe microscope remains the reference instrument for the most demanding endodontics, but the gap in ergonomic cost is smaller than it is often assumed to be. In an assessment of 10 operators in endodontics, RULA scores for loupes and microscope were close to one another and both were better than the naked eye (p \u0026lt; 0.001) (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/40265995\/\"\u003eInt Endod J 2026;59(6):1102–1109, PMID 40265995\u003c\/a\u003e, checked 2026-11-21).\u003c\/p\u003e\n\n\u003ch2\u003eWhat does the evidence say about magnification and posture at this level?\u003c\/h2\u003e\n\u003cp\u003eThe posture literature is more consistent than the magnification literature, and it is worth separating the two. In a comparison across 146 students and 30 dentists, the refractive prismatic design carried the lowest neck-risk score, while the Galilean design did not beat the naked eye on that metric (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/41072903\/\"\u003eJ Dent 2025;163:106162, PMID 41072903\u003c\/a\u003e, checked 2026-11-21). In a crossover study in dental students, magnification did not change muscle activity or working distance, though the naked eye produced the larger angular deviation (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/40526987\/\"\u003eAppl Ergon 2025;129:104579, PMID 40526987\u003c\/a\u003e, checked 2026-11-21).\u003c\/p\u003e\n\u003cp\u003eWhere an angled design has been measured directly, declination is the mechanism: in a crossover study of 29 hygiene students and faculty, vertically adjustable front-lens-mounted loupes reduced head tilt significantly against through-the-lens loupes in both arches (p = 0.000), with the authors identifying 40°–50° of declination as the range that maintains minimal forward head posture (\u003ca href=\"https:\/\/jdh.adha.org\/content\/jdenthyg\/95\/3\/59.full\"\u003eWilson et al., J Dent Hyg 2021;95(3):59–64\u003c\/a\u003e, checked 2026-11-21). An earlier pilot in hygienists found that loupes influenced neck and trunk flexion during scaling (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/33000517\/\"\u003eInt J Dent Hyg 2021;19(1):106–113, PMID 33000517\u003c\/a\u003e, checked 2026-11-21).\u003c\/p\u003e\n\u003cp\u003eNone of this makes a pair of loupes a treatment for an existing injury. The general duty is in \u003ca href=\"https:\/\/www.law.cornell.edu\/uscode\/text\/29\/654\"\u003e29 U.S.C. 654(a)(1)\u003c\/a\u003e, and California's repetitive motion injuries rule, \u003ca href=\"https:\/\/www.dir.ca.gov\/title8\/5110.html\"\u003eCal. Code Regs. Title 8, section 5110\u003c\/a\u003e, applies when more than one employee has a physician-diagnosed injury caused predominantly by the job.\u003c\/p\u003e\n\n\u003ch2\u003eHow much does a 70 mm depth of field cost in refocusing?\u003c\/h2\u003e\n\u003cp\u003eMore than the literature on magnification suggests, and less than a nervous first week implies. Seventy millimetres of depth is about the vertical run of a prepared crown, so slow postural drift takes you out of focus roughly twice as often as it does at 4.0×, where the figure is 80 mm. The fix is support rather than effort: forearms braced, patient reclined to bring the field to you, and a stool height that lets your thighs slope slightly down.\u003c\/p\u003e\n\u003cp\u003eThe measurement behind that advice is individual variation. In a study of dental hygienists, measured resolution performance varied by up to 300% between participants and self-assessment correlated only weakly with the measurement (r = 0.27) (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/29603638\/\"\u003eInt J Dent Hyg 2018;16(3):357–361, PMID 29603638\u003c\/a\u003e, checked 2026-11-21). At 5.0× that variation is amplified by the narrower field, so a pair built to a guessed distance is a pair that will be re-made.\u003c\/p\u003e\n\n\u003ch2\u003eDo you need a headlight at 5.0x?\u003c\/h2\u003e\n\u003cp\u003eIn practice, for most of the procedures that justify this power, yes. The cone of light reaching the eye from the working point narrows as magnification rises, and a shadow across a 60 mm field is a shadow across the whole visible area. A coaxial light runs the beam along the optical axis so illumination follows the view rather than crossing it.\u003c\/p\u003e\n\u003cp\u003eThe matching accessory is the \u003ca href=\"\/fr\/products\/soco-scml05-wireless-led-dental-headlight\"\u003eSCML05 headlight\u003c\/a\u003e: coaxial LED, 4,550 K colour temperature, colour rendering index 70, bayonet clip for SOCO frames, rechargeable battery with charger and adapter included. It is a separate item. At 5.0× the colour rendering matters as much as the output, because the differences being judged — caries staining, composite shade at a margin, tissue colour — are exactly what a low index flattens; the CIE test-colour method in \u003ca href=\"https:\/\/cie.co.at\/publications\/method-measuring-and-specifying-colour-rendering-properties-light-sources\"\u003eCIE 13.3-1995\u003c\/a\u003e (checked 2026-11-21) is the reference for how that index is derived.\u003c\/p\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/SOCO-SCML05.jpg?v=1795237188\" alt=\"SOCO SCML05 coaxial LED headlight, bayonet clip version that mounts on the SOCO 5.0x prismatic frame\" width=\"600\" height=\"600\" loading=\"lazy\"\u003e\n\n\u003ch2\u003eHow do you measure for a 5.0x build?\u003c\/h2\u003e\n\u003cp\u003eTwo numbers decide the pair. First, the working distance from the outer corner of your eye to the point where the instrument meets the tooth, taken in your working posture with the patient positioned as usual — not from a wall chart. Second, the pupil distance against the 50–80 mm adjustable range. The listing builds 400 mm to 580 mm to order with 450 mm as standard.\u003c\/p\u003e\n\u003cp\u003eThe reason to be pedantic is that the pair cannot compensate afterwards: a fixed non-flip mount has no adjustment for a distance that was measured optimistically. A survey of 308 loupe owners found that fitting and magnification review after purchase were rarely carried out (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/41903621\/\"\u003eJ Dent 2026;169:106661, PMID 41903621\u003c\/a\u003e, checked 2026-11-21), which is how a small measurement error becomes a permanent habit of leaning.\u003c\/p\u003e\n\n\u003ch2\u003eWhere does 5.0x sit between 4.0x and 6.0x?\u003c\/h2\u003e\n\u003cp\u003eIn the middle of the prismatic group, and that position is the argument for it. It keeps enough field to stay oriented — ten millimetres more than the 6.0×, ten fewer than the 4.0× — and it keeps enough resolution to see what a 4.0× will not resolve at the edge of the image.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eMagnification\u003c\/th\u003e\n\u003cth\u003eField of view\u003c\/th\u003e\n\u003cth\u003eWorking distance\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003cth\u003ePupillary distance\u003c\/th\u003e\n\u003cth\u003eHeadlight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCE200-25-450\u003c\/td\u003e\n\u003ctd\u003e2.5×, Galilean\u003c\/td\u003e\n\u003ctd\u003e120 mm at 450 mm\u003c\/td\u003e\n\u003ctd\u003e450 mm standard\u003c\/td\u003e\n\u003ctd\u003e60 g\u003c\/td\u003e\n\u003ctd\u003e50–80 mm\u003c\/td\u003e\n\u003ctd\u003eSCML05 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCE200-35-450\u003c\/td\u003e\n\u003ctd\u003e3.5×, Galilean\u003c\/td\u003e\n\u003ctd\u003e80 mm at 450 mm\u003c\/td\u003e\n\u003ctd\u003e450 mm, 350–580 mm to order\u003c\/td\u003e\n\u003ctd\u003e72 g\u003c\/td\u003e\n\u003ctd\u003e50–80 mm\u003c\/td\u003e\n\u003ctd\u003eSCML05 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCE300-40-450\u003c\/td\u003e\n\u003ctd\u003e4.0×, prismatic, 45°\u003c\/td\u003e\n\u003ctd\u003e70 mm at 450 mm\u003c\/td\u003e\n\u003ctd\u003e450 mm, 400–580 mm to order\u003c\/td\u003e\n\u003ctd\u003e65 g\u003c\/td\u003e\n\u003ctd\u003e50–80 mm\u003c\/td\u003e\n\u003ctd\u003eSCML05 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCE300-50-450 (this page)\u003c\/td\u003e\n\u003ctd\u003e5.0×, prismatic, 45°\u003c\/td\u003e\n\u003ctd\u003e60 mm at 450 mm\u003c\/td\u003e\n\u003ctd\u003e450 mm, 400–580 mm to order\u003c\/td\u003e\n\u003ctd\u003e66 g\u003c\/td\u003e\n\u003ctd\u003e50–80 mm\u003c\/td\u003e\n\u003ctd\u003eSCML05 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSCE300-60-450\u003c\/td\u003e\n\u003ctd\u003e6.0×, prismatic, 45°\u003c\/td\u003e\n\u003ctd\u003e50 mm at 450 mm\u003c\/td\u003e\n\u003ctd\u003e450 mm, 400–580 mm to order\u003c\/td\u003e\n\u003ctd\u003e67 g\u003c\/td\u003e\n\u003ctd\u003e50–80 mm\u003c\/td\u003e\n\u003ctd\u003eSCML05 compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe usual pairing is this 5.0× with a \u003ca href=\"\/fr\/products\/soco-prismatic-dental-loupes-4-0x-450mm\"\u003e4.0× prismatic pair\u003c\/a\u003e for the working day, or with a \u003ca href=\"\/fr\/products\/soco-galilean-dental-loupes-3-5x-450mm\"\u003e3.5× Galilean pair\u003c\/a\u003e for breadth. The \u003ca href=\"\/fr\/collections\/dental-loupes\"\u003edental loupes collection\u003c\/a\u003e lists every model on one page; if the case mix is surgical rather than restorative, the \u003ca href=\"\/fr\/products\/soco-prismatic-dental-loupes-6-0x-450mm\"\u003e6.0× prismatic pair\u003c\/a\u003e is the other end of the same decision.\u003c\/p\u003e\n\n\u003ch2\u003eHow should the pair be cleaned between patients?\u003c\/h2\u003e\n\u003cp\u003eWipe, never soak, never autoclave. Reprocessing instructions published for dental loupes by two established manufacturers exclude immersion disinfection, machine cleaning and disinfection, ultrasonic cleaning and sterilisation, and exclude alcoholic agents on coated optics; alcohol-free cleaning and disinfectant products are substituted (manufacturer instructions read 2026-11-21). The frame carries an alcohol-free wipe between patients; the lenses take a dry microfibre cloth.\u003c\/p\u003e\n\u003cp\u003eThe need is documented rather than theoretical: contamination of dental magnification loupes has been shown in clinical use (\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/31229256\/\"\u003eJADA 2019;150(8):689–694, PMID 31229256\u003c\/a\u003e, checked 2026-11-21). Loupes are also not eye protection — \u003ca href=\"https:\/\/www.law.cornell.edu\/cfr\/text\/29\/1910.1030\"\u003e29 CFR 1910.1030(d)(3)(i)\u003c\/a\u003e requires the employer to provide appropriate protective equipment, including eye protection, at no cost, and safety glasses meet that requirement; the pair is worn with them.\u003c\/p\u003e\n\n\u003ch2\u003eWhat should a United States buyer confirm before the build?\u003c\/h2\u003e\n\u003cp\u003eThe measured working distance, the pupil distance against 50–80 mm, and the shipping terms. For United States addresses, shipping cost and any duties or taxes are shown at checkout, and duties and taxes for United States addresses are prepaid, so the checkout figure is the amount charged with nothing further to settle on delivery.\u003c\/p\u003e\n\u003cp\u003eOne tax detail that catches students: \u003ca href=\"https:\/\/www.irs.gov\/publications\/p970\"\u003eIRS Publication 970\u003c\/a\u003e counts only course-required equipment as a qualified education expense. A pair bought by a practice for its operators is a practice purchase. Groups buying several pairs send one measurement list through the \u003ca href=\"\/fr\/pages\/wholesale\"\u003einstitutional account enquiry page\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eSources, checked 2026-11-21\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/40265995\/\"\u003eMusculoskeletal risk of first-year postgraduate endodontic students using dental microscope, ergonomic loupes or no magnification\u003c\/a\u003e, \u003cem\u003eInt Endod J\u003c\/em\u003e 2026, 59(6), 1102–1109 (PMID 40265995).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/41072903\/\"\u003eA comparative study of postural impact and benefits from loupes in undergraduate and graduate dentists\u003c\/a\u003e, \u003cem\u003eJ Dent\u003c\/em\u003e 2025, 163, 106162 (PMID 41072903).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/40526987\/\"\u003eMagnification of the Galilean system and work posture in dental students: a crossover study\u003c\/a\u003e, \u003cem\u003eAppl Ergon\u003c\/em\u003e 2025, 129, 104579 (PMID 40526987).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/jdh.adha.org\/content\/jdenthyg\/95\/3\/59.full\"\u003eDental magnification loupes and head tilt angles among dental hygiene students and faculty\u003c\/a\u003e, \u003cem\u003eJ Dent Hyg\u003c\/em\u003e 2021, 95(3), 59–64.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/33000517\/\"\u003eMagnification loupes influence on neck and trunk flexion of dental hygienists while scaling — a pilot study\u003c\/a\u003e, \u003cem\u003eInt J Dent Hyg\u003c\/em\u003e 2021, 19(1), 106–113 (PMID 33000517).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/29603638\/\"\u003eNear visual acuity of dental hygienists with and without magnification\u003c\/a\u003e, \u003cem\u003eInt J Dent Hyg\u003c\/em\u003e 2018, 16(3), 357–361 (PMID 29603638).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/41903621\/\"\u003eWork-related musculoskeletal symptoms across the dental training–practice continuum\u003c\/a\u003e, \u003cem\u003eJ Dent\u003c\/em\u003e 2026, 169, 106661 (PMID 41903621).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/31229256\/\"\u003eDisinfection of dental loupes: a pilot study\u003c\/a\u003e, \u003cem\u003eJADA\u003c\/em\u003e 2019, 150(8), 689–694 (PMID 31229256).\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cie.co.at\/publications\/method-measuring-and-specifying-colour-rendering-properties-light-sources\"\u003eCIE 13.3-1995, Method of measuring and specifying colour rendering properties of light sources\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.law.cornell.edu\/uscode\/text\/29\/654\"\u003e29 U.S.C. 654(a)(1)\u003c\/a\u003e, \u003ca href=\"https:\/\/www.dir.ca.gov\/title8\/5110.html\"\u003eCal. Code Regs. Title 8, section 5110\u003c\/a\u003e, \u003ca href=\"https:\/\/www.law.cornell.edu\/cfr\/text\/29\/1910.1030\"\u003e29 CFR 1910.1030(d)(3)(i)\u003c\/a\u003e, \u003ca href=\"https:\/\/www.irs.gov\/publications\/p970\"\u003eIRS Publication 970\u003c\/a\u003e. All sources checked 2026-11-21.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat ships with the pair\u003c\/h3\u003e\n\u003cp\u003eOne pair of SOCO SCE300-50-450 prismatic loupes at 5.0× with the 45° angled path, built to your measured working distance, pupil distance adjustable across 50–80 mm. Case and cleaning cloth included; the headlight is a separate item.\u003c\/p\u003e\n\n\u003cp class=\"soco-meta\"\u003eDistributed in Canada by CliniEco Medical, Health Canada establishment licence MDEL #35334. Specification values on this page are taken from the product listing and the specification card for SOCO-SCE300-50-450, re-read on 2026-11-21; where a value differs from another surface on this listing, the listing value stands.\u003c\/p\u003e\n\u003c\/div\u003e\n","brand":"SOCO","offers":[{"title":"5.0x · Prismatic Ergonomic","offer_id":49481062056158,"sku":"SOCO-SCE300-50-450","price":1449.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/SOCO-SCE300-50-450.jpg?v=1795235341","url":"https:\/\/clinieco.ca\/fr\/products\/soco-prismatic-dental-loupes-5-0x-450mm","provider":"CliniEco Medical","version":"1.0","type":"link"}