{"product_id":"mtc-bio-exact-volume-transfer-pipettes-20-to-500-microlitre-sterile-bags","title":"MTC Bio Exact Volume Transfer Pipettes, 20 to 500 microlitre, Sterile Bags","description":"\u003cp\u003e\u003cstrong\u003eSterile exact volume transfer pipettes from 20 to 500 microlitre,\u003c\/strong\u003e ten fixed volumes with matched stem lengths, in resealable bags of 1,000 to 5,000, shipped from North American stock.\u003c\/p\u003e\n\u003cp\u003eAn exact volume transfer pipette has a bulb moulded to one volume, so the draw stops at that volume and the operator does not have to watch a graduation. This range runs from 20 microlitre at 53 mm to 500 microlitre at 120 mm, with the stem length matched to the volume, so a lab can hold one tool per volume instead of one pipette with a printed scale. All configurations are sterile and bagged in resealable bags.\u003c\/p\u003e\n\u003ch2\u003eWhat is in a bag of exact volume pipettes?\u003c\/h2\u003e\n\u003cp\u003eThe 20 microlitre configuration holds 5,000 pipettes in 10 resealable bags, so 500 per bag across a 10-bag case. The 50, 80, 100, 150, 200 and 250 microlitre configurations hold 2,500 in five bags, and the 300, 400 and 500 microlitre configurations hold 1,000 in two bags.\u003c\/p\u003e\n\u003cp\u003eVolume decides the bag count because the bulb grows with the volume: a 500 microlitre bulb takes roughly ten times the shelf space of a 20 microlitre one, so the case is smaller for the larger volumes.\u003c\/p\u003e\n\u003ch2\u003eHow do you pick the volume, and when is exact volume worth it?\u003c\/h2\u003e\n\u003cp\u003eExact volume earns its price where a step depends on a repeatable small volume and a pipettor is either unavailable or slower than the task: adding a fixed reagent to a strip, inoculating a fixed volume into broth, transferring a stain. The 20 to 100 microlitre range covers most of those steps, and the 150 to 500 microlitre range covers bulk reagent additions.\u003c\/p\u003e\n\u003cp\u003eStem length tracks volume: 53 mm for 20 microlitre, 72 mm for 50, 96 to 100 mm through 80 to 200, and 113 to 120 mm for 250 to 500. A short stem on a large volume gives the bulb a shorter drop, which is what keeps a 500 microlitre transfer controllable.\u003c\/p\u003e\n\u003ch2\u003eWhat are the specifications?\u003c\/h2\u003e\n\u003cp\u003eEvery configuration below is a separate case line. The manufacturer reference is what appears on the quotation, the packing slip and the lot documentation, so quote it when you ask for a certificate of analysis.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eManufacturer reference\u003c\/th\u003e\n\u003cth\u003ePack\u003c\/th\u003e\n\u003cth\u003eCase\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Volume Transfer Pipette · 20uL · 53mm · sterile · 10 resealable \u003c\/td\u003e\n\u003ctd\u003eE9500-20\u003c\/td\u003e\n\u003ctd\u003e5,000 per pack\u003c\/td\u003e\n\u003ctd\u003e50,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Volume Transfer Pipette · 50uL · 72mm · sterile · 5 resealable b\u003c\/td\u003e\n\u003ctd\u003eE9500-50\u003c\/td\u003e\n\u003ctd\u003e2,500 per pack\u003c\/td\u003e\n\u003ctd\u003e12,500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Volume Transfer Pipette · 80uL · 96mm · sterile · 5 resealable b\u003c\/td\u003e\n\u003ctd\u003eE9500-80\u003c\/td\u003e\n\u003ctd\u003e2,500 per pack\u003c\/td\u003e\n\u003ctd\u003e12,500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Volume Transfer Pipette · 100uL · 86mm · sterile · 5 resealable \u003c\/td\u003e\n\u003ctd\u003eE9500-100\u003c\/td\u003e\n\u003ctd\u003e2,500 per pack\u003c\/td\u003e\n\u003ctd\u003e12,500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Volume Transfer Pipette · 150uL · 100mm · sterile · 5 resealable\u003c\/td\u003e\n\u003ctd\u003eE9500-150\u003c\/td\u003e\n\u003ctd\u003e2,500 per pack\u003c\/td\u003e\n\u003ctd\u003e12,500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Volume Transfer Pipette · 200uL · 100mm · sterile · 5 resealable\u003c\/td\u003e\n\u003ctd\u003eE9500-200\u003c\/td\u003e\n\u003ctd\u003e2,500 per pack\u003c\/td\u003e\n\u003ctd\u003e12,500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Volume Transfer Pipette · 250uL · 113mm · sterile · 5 resealable\u003c\/td\u003e\n\u003ctd\u003eE9500-250\u003c\/td\u003e\n\u003ctd\u003e2,500 per pack\u003c\/td\u003e\n\u003ctd\u003e12,500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Volume Transfer Pipette · 300uL · 113mm · sterile · 2 resealable\u003c\/td\u003e\n\u003ctd\u003eE9500-300\u003c\/td\u003e\n\u003ctd\u003e1,000 per pack\u003c\/td\u003e\n\u003ctd\u003e2,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Volume Transfer Pipette · 400uL · 115mm · sterile · 2 resealable\u003c\/td\u003e\n\u003ctd\u003eE9500-400\u003c\/td\u003e\n\u003ctd\u003e1,000 per pack\u003c\/td\u003e\n\u003ctd\u003e2,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Volume Transfer Pipette · 500uL · 120mm · sterile · 2 resealable\u003c\/td\u003e\n\u003ctd\u003eE9500-500\u003c\/td\u003e\n\u003ctd\u003e1,000 per pack\u003c\/td\u003e\n\u003ctd\u003e2,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHow many exact volume pipettes does a bench use?\u003c\/h2\u003e\n\u003cp\u003eA bench doing 40 fixed additions a day uses 40 pipettes, about 850 a month, so a 2,500-pipette case of one volume lasts three months. Where a protocol uses three volumes, the consumption splits across three cases, and the reorder point should be set per volume rather than for pipettes as a class.\u003c\/p\u003e\n\u003cp\u003eBecause these are single-volume tools, a bench that changes protocol often ends up with several part-used cases; label each bag with the volume on the outside so a bag is not opened twice for the same step.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eWorking pattern\u003c\/th\u003e\n\u003cth\u003eUsed per month\u003c\/th\u003e\n\u003cth\u003eCase covers\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne bench, light use\u003c\/td\u003e\n\u003ctd\u003eabout 300 pieces\u003c\/td\u003e\n\u003ctd\u003eroughly 8 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne bench, full shift\u003c\/td\u003e\n\u003ctd\u003eabout 2,000 pieces\u003c\/td\u003e\n\u003ctd\u003eroughly 2 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwo benches\u003c\/td\u003e\n\u003ctd\u003eabout 4,000 pieces\u003c\/td\u003e\n\u003ctd\u003eunder one month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCounts above are planning figures from pack and case sizes on this page, not a forecast of your own consumption; check them against a week of your own bench records before setting a reorder point.\u003c\/p\u003e\n\u003ch2\u003eHow is it shipped, and how should it be stored?\u003c\/h2\u003e\n\u003cp\u003ePipettes ship from North American stock, 1 to 2 business days in Ontario, 2 to 4 across Canada, 2 to 3 to US addresses. Each resealable bag carries the manufacturer reference and lot.\u003c\/p\u003e\n\u003cp\u003eReseal the bag after each use and store flat: a bulb that has been compressed under a carton will not return to its moulded volume, and a pipette that is off volume is worse than no pipette at all.\u003c\/p\u003e\n\u003ch2\u003eWhat we do not claim\u003c\/h2\u003e\n\u003cp\u003eSingle-use laboratory consumables for liquid transfer. Not sold as medical devices for patient treatment. The volume is a nominal moulded value rather than a calibration; sterility is the manufacturer's stated value per configuration.\u003c\/p\u003e\n\u003cp\u003eWhat we cannot do is certify the delivered drop of a moulded bulb: if a step needs a tolerance tighter than the moulded volume, send us the tolerance and we will say whether this range fits.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eHow many pipettes per case?\u003c\/summary\u003e\u003cp\u003e20 microlitre holds 5,000 in 10 bags of 500; 50 to 250 microlitre hold 2,500 in five bags; 300 to 500 microlitre hold 1,000 in two bags.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs the volume exact?\u003c\/summary\u003e\u003cp\u003eThe bulb is moulded to the stated volume so the draw stops there; it is a nominal value rather than a calibration, and delivered volume depends on how the pipette is held.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eAre these pipettes sterile?\u003c\/summary\u003e\u003cp\u003eYes, all configurations on this page are sterile and packed in resealable bags with the lot on the bag.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhich volume should a general bench keep?\u003c\/summary\u003e\u003cp\u003e20, 100 and 200 microlitre cover most fixed additions; add 500 microlitre only if a bulk reagent step needs it.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan an exact volume pipette replace a pipettor?\u003c\/summary\u003e\u003cp\u003eFor a fixed volume, often yes; for variable volumes or for a measured transfer into a calibrated vessel, a pipettor or a graduated pipette remains the right tool.\u003c\/p\u003e\u003c\/details\u003e\n\u003ch2\u003eChoosing the right option\u003c\/h2\u003e\u003cp\u003eRelated products in the same laboratory line:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/products\/specimen-container-120ml-sterile-screw-cap-100-pack\"\u003especimen container 120ml sterile screw cap 100 pack\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/products\/mtc-bio-sureseal-s-1-5ml-sterile-microcentrifuge-tubes-500-pack\"\u003emtc bio sureseal s 1 5ml sterile microcentrifuge tubes 500 pack\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eBackground reading before you order:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/transfer-pipettes-vs-serological-pipettes\"\u003etransfer pipettes vs serological pipettes\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/fr\/products\/specimen-container-120ml-sterile-screw-cap-100-pack\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/E9500-20.jpg?v=1795452468\" alt=\"Laboratory consumables\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"MTC Bio","offers":[{"title":"Exact Volume Transfer Pipette · 20uL · 53mm · sterile · 10 resealable bags","offer_id":49487124070622,"sku":"CLI-TPIP-X-E9500-20","price":3834.65,"currency_code":"CAD","in_stock":true},{"title":"Exact Volume Transfer Pipette · 50uL · 72mm · sterile · 5 resealable bags","offer_id":49487795749086,"sku":"CLI-TPIP-X-E9500-50","price":958.64,"currency_code":"CAD","in_stock":true},{"title":"Exact Volume Transfer Pipette · 80uL · 96mm · sterile · 5 resealable bags","offer_id":49487795781854,"sku":"CLI-TPIP-X-E9500-80","price":958.64,"currency_code":"CAD","in_stock":true},{"title":"Exact Volume Transfer Pipette · 100uL · 86mm · sterile · 5 resealable bags","offer_id":49487795814622,"sku":"CLI-TPIP-X-E9500-100","price":1044.57,"currency_code":"CAD","in_stock":true},{"title":"Exact Volume Transfer Pipette · 150uL · 100mm · sterile · 5 resealable bag","offer_id":49487795847390,"sku":"CLI-TPIP-X-E9500-150","price":1044.57,"currency_code":"CAD","in_stock":true},{"title":"Exact Volume Transfer Pipette · 200uL · 100mm · sterile · 5 resealable bag","offer_id":49487795880158,"sku":"CLI-TPIP-X-E9500-200","price":1044.57,"currency_code":"CAD","in_stock":true},{"title":"Exact Volume Transfer Pipette · 250uL · 113mm · sterile · 5 resealable bag","offer_id":49487795912926,"sku":"CLI-TPIP-X-E9500-250","price":1044.57,"currency_code":"CAD","in_stock":true},{"title":"Exact Volume Transfer Pipette · 300uL · 113mm · sterile · 2 resealable bag","offer_id":49487795978462,"sku":"CLI-TPIP-X-E9500-300","price":222.16,"currency_code":"CAD","in_stock":true},{"title":"Exact Volume Transfer Pipette · 400uL · 115mm · sterile · 2 resealable bag","offer_id":49487796011230,"sku":"CLI-TPIP-X-E9500-400","price":222.16,"currency_code":"CAD","in_stock":true},{"title":"Exact Volume Transfer Pipette · 500uL · 120mm · sterile · 2 resealable bag","offer_id":49487796076766,"sku":"CLI-TPIP-X-E9500-500","price":222.16,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/E9500-20.jpg?v=1795452468","url":"https:\/\/clinieco.ca\/fr\/products\/mtc-bio-exact-volume-transfer-pipettes-20-to-500-microlitre-sterile-bags","provider":"CliniEco Medical","version":"1.0","type":"link"}