{"product_id":"mtc-bio-5-ml-transfer-pipettes-large-bulb-sterile-or-bulk-graduated-options","title":"MTC Bio 5 mL Transfer Pipettes, Large Bulb, Sterile or Bulk, Graduated Options","description":"\u003cp\u003e\u003cstrong\u003eMTC Bio 5 mL transfer pipettes with a large bulb,\u003c\/strong\u003e in non-sterile bulk packs of 250 and sterile formats up to 5,000 per case, shipped from North American stock.\u003c\/p\u003e\n\u003cp\u003eA transfer pipette is the tool a bench reaches for when a pipettor is overkill: moving a few millilitres between a tube and a tube, adding a reagent to a strip, taking a sample out of a specimen container. This range keeps the same 5 mL large bulb and changes only what a protocol actually cares about: sterile or non-sterile, graduated to 1 mL or unmarked, standard tip or extended tip for narrow vessels, and bulk pack or individual wrap. Polyethylene body, one piece, no separate bulb to lose.\u003c\/p\u003e\n\u003ch2\u003eWhat is in a case of 5 mL transfer pipettes?\u003c\/h2\u003e\n\u003cp\u003eBulk non-sterile configurations hold 250 pipettes per pack and 20 packs per case, so 5,000 pipettes. Sterile peel-pack configurations hold 500 per case in packs of 20, and individually wrapped sterile configurations hold 500 per case.\u003c\/p\u003e\n\u003cp\u003eBulk packs are for a bench that goes through pipettes quickly and does not need a sterile claim; the sterile formats are for cell work, microbiology and any step where the pipette enters a sterile vessel.\u003c\/p\u003e\n\u003ch2\u003eWhich format should you order: bulk, peel pack or individually wrapped?\u003c\/h2\u003e\n\u003cp\u003eBulk is the working stock for non-sterile steps: staining, reagent transfer, waste removal. Peel packs of 20 keep the rest of the pack covered while one pipette is in use, which is the usual choice for a sterile bench that uses several pipettes per session. Individually wrapped is for a controlled step where each pipette must be traceable to an unopened wrapper, and it is the format most often asked for in audit-facing SOPs.\u003c\/p\u003e\n\u003cp\u003eGraduation is a separate decision: graduated to 1 mL lets a technician estimate volume directly in the pipette, while unmarked pipettes push the measurement back to a graduated tube. Extended tips reach the bottom of a narrow 15 mL tube without the bulb touching the rim.\u003c\/p\u003e\n\u003ch2\u003eWhat are the specifications?\u003c\/h2\u003e\n\u003cp\u003eEvery configuration below is a separate case line. The manufacturer reference is what appears on the quotation, the packing slip and the lot documentation, so quote it when you ask for a certificate of analysis.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eManufacturer reference\u003c\/th\u003e\n\u003cth\u003ePack\u003c\/th\u003e\n\u003cth\u003eCase\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 5mL · large bulb · non-sterile · bulk pack · 250\/pk\u003c\/td\u003e\n\u003ctd\u003eP4111-00\u003c\/td\u003e\n\u003ctd\u003e250 per pack\u003c\/td\u003e\n\u003ctd\u003e5,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 5mL · large bulb · sterile · individually wrapped ·\u003c\/td\u003e\n\u003ctd\u003eP4111-11\u003c\/td\u003e\n\u003ctd\u003e500 per pack\u003c\/td\u003e\n\u003ctd\u003e500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 5mL · large bulb · sterile · peel packs of 20 · 500\u003c\/td\u003e\n\u003ctd\u003eP4111-14\u003c\/td\u003e\n\u003ctd\u003e500 per pack\u003c\/td\u003e\n\u003ctd\u003e1,500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 5mL · large bulb · graduated to 1mL · non-sterile ·\u003c\/td\u003e\n\u003ctd\u003eP4113-00\u003c\/td\u003e\n\u003ctd\u003e250 per pack\u003c\/td\u003e\n\u003ctd\u003e5,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 5mL · large bulb · graduated to 1mL · sterile · ind\u003c\/td\u003e\n\u003ctd\u003eP4113-11\u003c\/td\u003e\n\u003ctd\u003e500 per pack\u003c\/td\u003e\n\u003ctd\u003e500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 5mL · extended tip · non-sterile · bulk pack · 500\/\u003c\/td\u003e\n\u003ctd\u003eP4122-01\u003c\/td\u003e\n\u003ctd\u003e500 per pack\u003c\/td\u003e\n\u003ctd\u003e3,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 5mL · extended tip · sterile · individually wrapped\u003c\/td\u003e\n\u003ctd\u003eP4122-11\u003c\/td\u003e\n\u003ctd\u003e500 per pack\u003c\/td\u003e\n\u003ctd\u003e500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHow many transfer pipettes does a bench use in a month?\u003c\/h2\u003e\n\u003cp\u003eA bench performing 30 specimen preparations a day with one pipette per preparation uses 30 a day, about 650 a month, so a 5,000-pipette bulk case lasts seven to eight months. A sterile peel-pack user doing 20 sterile transfers a day uses 400 a month and a 500-count case lasts about five weeks.\u003c\/p\u003e\n\u003cp\u003eBecause a bulk case is large, split storage matters: keep one open pack on the bench and the rest of the case closed and dry, and rotate stock so the oldest pack is used first.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eWorking pattern\u003c\/th\u003e\n\u003cth\u003eUsed per month\u003c\/th\u003e\n\u003cth\u003eCase covers\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne bench, light use\u003c\/td\u003e\n\u003ctd\u003eabout 300 pieces\u003c\/td\u003e\n\u003ctd\u003eroughly 8 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne bench, full shift\u003c\/td\u003e\n\u003ctd\u003eabout 2,000 pieces\u003c\/td\u003e\n\u003ctd\u003eroughly 2 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwo benches\u003c\/td\u003e\n\u003ctd\u003eabout 4,000 pieces\u003c\/td\u003e\n\u003ctd\u003eunder one month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCounts above are planning figures from pack and case sizes on this page, not a forecast of your own consumption; check them against a week of your own bench records before setting a reorder point.\u003c\/p\u003e\n\u003ch2\u003eHow is it shipped, and what documentation comes with it?\u003c\/h2\u003e\n\u003cp\u003ePipettes ship from North American stock: 1 to 2 business days within Ontario, 2 to 4 across Canada and 2 to 3 to US addresses. Sterile formats carry the manufacturer reference and lot on the pack; the sterilisation documentation is available on request against that reference.\u003c\/p\u003e\n\u003cp\u003eStore the case closed and away from heat; polyethylene softens in a hot vehicle and a deformed bulb will not draw the stated volume. Do not re-sterilise a pipette.\u003c\/p\u003e\n\u003ch2\u003eWhat we do not claim\u003c\/h2\u003e\n\u003cp\u003eSingle-use laboratory consumables for liquid transfer. Not sold as medical devices for patient treatment. Sterility, graduation and tip shape are the manufacturer's stated values; where a configuration is not marked sterile, treat it as non-sterile.\u003c\/p\u003e\n\u003cp\u003eWhat we cannot do is choose between graduated and unmarked for your SOP: send the step that measures volume and we will tell you which format keeps the measurement in one place.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eHow many pipettes are in a bulk case?\u003c\/summary\u003e\u003cp\u003e250 pipettes per pack and 20 packs per case, so 5,000 non-sterile bulk pipettes; sterile formats ship 500 per case.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs the 5 mL graduation accurate enough for a protocol?\u003c\/summary\u003e\u003cp\u003eThe graduation is a moulded mark for estimating volume, not a calibrated measurement; where a protocol needs a measured volume, use a graduated cylinder or a pipettor.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat does extended tip mean?\u003c\/summary\u003e\u003cp\u003eThe tip is longer and narrower than the standard tip, so it reaches the bottom of a narrow tube without the bulb touching the rim.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eAre the sterile pipettes individually wrapped?\u003c\/summary\u003e\u003cp\u003eBoth formats exist: peel packs of 20 for bench use and individual wraps where each pipette must come from an unopened wrapper.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan transfer pipettes be used with acids or solvents?\u003c\/summary\u003e\u003cp\u003eThe body is polyethylene, which suits aqueous solutions and many alcohols; check chemical compatibility before use with strong solvents, and ask us if you need the manufacturer's compatibility list.\u003c\/p\u003e\u003c\/details\u003e\n\u003ch2\u003eChoosing the right option\u003c\/h2\u003e\u003cp\u003eRelated products in the same laboratory line:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/products\/specimen-container-120ml-sterile-screw-cap-100-pack\"\u003especimen container 120ml sterile screw cap 100 pack\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/products\/stool-collection-kit-sterile-100-pack\"\u003estool collection kit sterile 100 pack\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eBackground reading before you order:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/transfer-pipettes-vs-serological-pipettes\"\u003etransfer pipettes vs serological pipettes\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/fr\/products\/specimen-container-120ml-sterile-screw-cap-100-pack\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/P4111-w-measurements.jpg?v=1795451544\" alt=\"Laboratory consumables\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"MTC Bio","offers":[{"title":"Transfer pipette · 5mL · large bulb · non-sterile · bulk pack · 250\/pk","offer_id":49487111717086,"sku":"CLI-TPIP-5-P4111-00","price":408.11,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 5mL · large bulb · sterile · individually wrapped · 500\/","offer_id":49487795257566,"sku":"CLI-TPIP-5-P4111-11","price":89.8,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 5mL · large bulb · sterile · peel packs of 20 · 500\/cs","offer_id":49487795290334,"sku":"CLI-TPIP-5-P4111-14","price":190.96,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 5mL · large bulb · graduated to 1mL · non-sterile · bulk","offer_id":49487795323102,"sku":"CLI-TPIP-5-P4113-00","price":408.11,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 5mL · large bulb · graduated to 1mL · sterile · individu","offer_id":49487795355870,"sku":"CLI-TPIP-5-P4113-11","price":89.8,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 5mL · extended tip · non-sterile · bulk pack · 500\/pk","offer_id":49487795388638,"sku":"CLI-TPIP-5-P4122-01","price":440.83,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 5mL · extended tip · sterile · individually wrapped · 50","offer_id":49487795421406,"sku":"CLI-TPIP-5-P4122-11","price":112.66,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/P4111-w-measurements.jpg?v=1795451544","url":"https:\/\/clinieco.ca\/fr\/products\/mtc-bio-5-ml-transfer-pipettes-large-bulb-sterile-or-bulk-graduated-options","provider":"CliniEco Medical","version":"1.0","type":"link"}