{"product_id":"clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency","title":"CliniEco Dental Ultrasonic Cleaner — 6 L Benchtop, CS6.2 Dual-Frequency 32\/48kHz","description":"\u003ch3\u003eThe cleaner that takes a full instrument cassette\u003c\/h3\u003e\n\u003cp\u003eMost benchtop ultrasonic cleaners sold online are built for jewellery, glasses and dentures. They are small, they are cheap, and they cannot take a standard dental instrument cassette — which means someone at your practice ends up running them in loose batches, twice.\u003c\/p\u003e\n\u003cp\u003eThe CS6.2 is a \u003cstrong\u003e6 L class\u003c\/strong\u003e unit. That is the size at which a full cassette fits in one cycle, which is the whole point of having a cleaner on the bench.\u003c\/p\u003e\n\u003cp\u003ecETL certified by Intertek to \u003cstrong\u003eCSA C22.2 No. 68\u003c\/strong\u003e and \u003cstrong\u003eUL 73\u003c\/strong\u003e. CliniEco Medical is a Canadian importer based in Toronto — ask us for the current lead time.\u003c\/p\u003e\n\u003ch3\u003eWhy the 6 L class is the one that matters\u003c\/h3\u003e\n\u003cp\u003eInstrument cassettes are the standard way dental practices sterilise. If your cleaner cannot take the cassette, you are either unpacking instruments to clean them or running two cycles, and both cost you time every single day.\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTank capacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eWhat fits\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eWho it suits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eUnder 3 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eHandpieces, retainers, loupes\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eFront desk, ortho, solo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003e6 L (this unit)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eA full instrument cassette\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eGeneral practice, hygiene\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e8 L and up\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eMultiple cassettes, larger runs\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eHigh-volume, labs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis is one of the two sizes Canadian dental practices buy most. The larger units in this range cost two to three times more, which is why most single-surgery practices stay in this class.\u003c\/p\u003e\n\u003ch3\u003eCertification you can actually check\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eElectrical certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\n\u003cstrong\u003ecETL (Intertek)\u003c\/strong\u003e, to \u003cstrong\u003eCSA C22.2 No. 68\u003c\/strong\u003e and \u003cstrong\u003eUL 73\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\n\u003cstrong\u003eAC 100–120 V \/ 60 Hz\u003c\/strong\u003e — North American supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eImporter of record\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\n\u003cstrong\u003eCliniEco Medical\u003c\/strong\u003e — Health Canada \u003cstrong\u003eMDEL #35334\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eManufactured by an OEM whose units are already in service with major North American dental distributors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eMany low-cost units sold online carry FCC, CE and RoHS only. Those are not electrical safety certifications, and a unit without an NRTL mark should not be installed in a commercial setting under the Ontario Electrical Safety Code. If you are being asked to sign off on a clinic, that distinction is the one that matters.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px\"\u003eTank capacity\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px\"\u003e\n\u003cstrong\u003e6 L\u003c\/strong\u003e (6 L class)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTank dimensions\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003e31.1 × 17.2 × 11.6 cm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eCleaning frequency\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eDual frequency — 32 kHz \/ 48 kHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTransducers\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e2 × industrial-grade, ≤ 80 W each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eTotal power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003e320 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eHeating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003e2 × ceramic heaters, 40–60 °C (selectable)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eDegassing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\n\u003cstrong\u003e120 s cycle\u003c\/strong\u003e (removes dissolved air that blunts cavitation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTimer\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eDigital, with heater control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTank \u0026amp; basket\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eSUS304 stainless steel, with a removable basket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eHousing (external shell)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eAluminium alloy + ABS — external only; never immersed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eUnit weight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eapprox. \u003cstrong\u003e9.2 kg\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eAC 100–120 V \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eCertification\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003ecETL (Intertek) · CSA C22.2 No. 68 · UL 73\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhat the dual frequency actually does for you\u003c\/h3\u003e\n\u003cp\u003eCavitation behaves differently at different frequencies, and this is not a marketing line — it is physics.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e32 kHz\u003c\/strong\u003e — larger, more energetic bubbles. Better at lifting heavier soils: cement residue, polishing paste, dried blood on hinged instruments.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e48 kHz\u003c\/strong\u003e — smaller, denser bubbles. Gentler, and it reaches into fine crevices, lumens and threaded joints without the erosion risk that aggressive low-frequency cavitation can cause on plated instruments.\u003c\/p\u003e\n\u003cp\u003eRunning both means one machine covers the whole load rather than forcing you to choose between \"heavy soil\" and \"delicate instrument\".\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDegassing matters more than people expect.\u003c\/strong\u003e Freshly filled tap water is saturated with dissolved air, and dissolved air absorbs the energy that should be forming cavitation bubbles. A 120-second degas cycle at the start is why the first load of the day performs like the fourth.\u003c\/p\u003e\n\u003ch3\u003eIn use\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eFill\u003c\/strong\u003e to the marked level, add the cleaning solution, and run the \u003cstrong\u003e120 s degas\u003c\/strong\u003e cycle.\u003c\/p\u003e\n\u003cp\u003e2. \u003cstrong\u003eHeat\u003c\/strong\u003e to 40–60 °C (selectable). Warm solution measurably improves soil removal.\u003c\/p\u003e\n\u003cp\u003e3. \u003cstrong\u003eLoad\u003c\/strong\u003e — instruments in the basket or cassette, not piled on the tank floor. Cavitation is blocked by contact surfaces.\u003c\/p\u003e\n\u003cp\u003e4. \u003cstrong\u003eRun\u003c\/strong\u003e the cycle, then \u003cstrong\u003erinse\u003c\/strong\u003e and inspect before sterilisation.\u003c\/p\u003e\n\u003cp\u003e5. \u003cstrong\u003eEmpty and dry\u003c\/strong\u003e the tank. Leaving solution in overnight is what shortens the life of the transducer plate.\u003c\/p\u003e\n\u003ch3\u003eConsumables that go with it\u003c\/h3\u003e\n\u003cp\u003eUltrasonic cleaning is a consumable line, not a one-off purchase.\u003c\/p\u003e\n\u003cp\u003e• \u003ca href=\"\/fr\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003e\u003cstrong\u003eEnzymatic ultrasonic cleaning solution\u003c\/strong\u003e\u003c\/a\u003e — 4 L concentrate. The right chemistry does more work than a longer cycle.\u003c\/p\u003e\n\u003cp\u003e• \u003ca href=\"\/fr\/collections\/dental-sterilization-essentials\"\u003e\u003cstrong\u003eSterilisation pouches, indicator tape and biological indicators\u003c\/strong\u003e\u003c\/a\u003e — for the steps after the cleaner.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e(We also supply the consumables above. Bundling them with the unit is how most practices run it.)\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it need a special outlet?\u003c\/strong\u003e No. AC 100–120 V \/ 60 Hz, standard North American supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I put instruments straight from the patient into it?\u003c\/strong\u003e Ideally, pre-rinse or wipe first. Ultrasonic cleaning is not a substitute for gross decontamination, and heavy debris shortens solution life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it damage my instruments?\u003c\/strong\u003e At 48 kHz, plated and hinged instruments are safe when they are not resting against each other or the tank wall. Aluminium and anodised surfaces should not be placed in an ultrasonic bath at all, regardless of machine.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often do I change the solution?\u003c\/strong\u003e Daily, or sooner if it is visibly soiled. This is the single most common reason practices report poor cleaning results.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you provide the documentation for a clinic audit?\u003c\/strong\u003e Yes — the certification reference for this model and our Health Canada establishment licence number are available on request, and we can send them ahead of purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it stocked in Canada?\u003c\/strong\u003e We import directly and ship anywhere in Canada. Ask us for the current lead time before you order and we will confirm it in writing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I get training or setup help?\u003c\/strong\u003e Yes. Write to us and we will walk you through the first cycle.\u003c\/p\u003e\n\u003ch3\u003eOrdering\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e$699.00.\u003c\/strong\u003e CliniEco Medical, Toronto, Ontario. Ask us for the current lead time before you order.\u003c\/p\u003e\n\u003cp\u003eCliniEco Medical is the importer of record: \u003cstrong\u003eEcology Source New Energy Technology Co., LTD. o\/a CliniEco Medical\u003c\/strong\u003e, Health Canada \u003cstrong\u003eMDEL #35334\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eQuestions about whether this is the right size for your practice — tell us how many cassettes you run per day and we will tell you straight, even if the answer is that you do not need this one.\u003c\/p\u003e\u003ch3\u003eStraight answers — including the things you may not want to hear\u003c\/h3\u003e\n\u003cp\u003eMost listings in this category skip the awkward parts. We do not, because the awkward parts are usually what decides the purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat this unit will not do.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIt will not clean aluminium or anodised instruments.\u003c\/strong\u003e No ultrasonic cleaner will. Anodised coatings and bare aluminium are attacked by the cavitation and by alkaline cleaning solutions. If you use aluminium trays or anodised cassettes, do not put them in any ultrasonic bath. This refers to what you place in the bath — the unit's own housing is aluminium alloy and sits outside the tank, so it is never immersed.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIt will not clean the inside of a narrow lumen on its own.\u003c\/strong\u003e Ultrasonic energy does not travel well down a small-diameter channel. Lumens and hinges need a brush as well — this is true of every unit at every price.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIt does not replace gross decontamination.\u003c\/strong\u003e Heavy debris should be wiped or rinsed off first. Solution life and cleaning performance both drop if you do not.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIt does not sterilise.\u003c\/strong\u003e This is a cleaner. Sterilisation is a separate step, in a separate machine.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat we can state plainly, that others often will not.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eThe tank holds 6 litres, and it measures 31.1 × 17.2 × 11.6 cm.\u003c\/strong\u003e Take a tape measure to your cassette before you buy. We would rather you check and not order than order and be disappointed.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eThe capacity figure is the real tank volume, not a model number.\u003c\/strong\u003e The model is CS6.2. The tank is 6 litres.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eThe electrical certification is cETL, to CSA C22.2 No. 68 and UL 73, issued by Intertek.\u003c\/strong\u003e We name the standard and the issuer so you can verify it. A product that says only \"FCC, CE and RoHS\" is telling you it holds no North American electrical safety certification — those three are emissions and materials marks, not safety marks, and a unit without an NRTL mark has no business being installed in a commercial setting.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eWe are the importer of record.\u003c\/strong\u003e Ecology Source New Energy Technology Co., LTD. o\/a CliniEco Medical, Health Canada MDEL #35334. That is on the label and on the paperwork, and it is who you hold responsible.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIt is not a no-name import.\u003c\/strong\u003e The unit is built by a manufacturer that also produces cleaners for established North American dental brands, and it ships with the manufacturer's own nameplate.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIf it is the wrong size for you, we will say so.\u003c\/strong\u003e Tell us how many cassettes you run per day and what instruments you put through them, and we will answer honestly — including when the honest answer is that you need a larger tank or a different machine.\u003c\/p\u003e\n\u003ch3\u003eSpecifications you can hold us to\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eTank capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\n\u003cstrong\u003e6 litres\u003c\/strong\u003e (model CS6.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTank dimensions\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e31.1 × 17.2 × 11.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eDual — 32 kHz \/ 48 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTransducers\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e2 × industrial grade, ≤ 80 W each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTotal power\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e320 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eHeating\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e2 × ceramic, 40–60 °C (selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eDegassing\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eAC 100–120 V \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eapprox. 9.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eCertification\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003ecETL (Intertek) · CSA C22.2 No. 68 · UL 73\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eImporter\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eCliniEco Medical — Health Canada MDEL #35334\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[\n{\"@type\":\"Question\",\"name\":\"Does it need a special outlet?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. AC 100–120 V \/ 60 Hz, standard North American supply.\"}},\n{\"@type\":\"Question\",\"name\":\"Can I put instruments straight from the patient into it?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Ideally, pre-rinse or wipe first. Ultrasonic cleaning is not a substitute for gross decontamination, and heavy debris shortens solution life.\"}},\n{\"@type\":\"Question\",\"name\":\"Can it damage my instruments?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"At 48 kHz, plated and hinged instruments are safe when they are not resting against each other or the tank wall. Aluminium and anodised surfaces should not be placed in an ultrasonic bath at all, regardless of machine.\"}},\n{\"@type\":\"Question\",\"name\":\"How often do I change the solution?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Daily, or sooner if it is visibly soiled. This is the single most common reason practices report poor cleaning results.\"}},\n{\"@type\":\"Question\",\"name\":\"Do you provide the documentation for a clinic audit?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — the certification reference for this model and our Health Canada establishment licence number are available on request, and we can send them ahead of purchase.\"}},\n{\"@type\":\"Question\",\"name\":\"Is it stocked in Canada?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"We import directly and ship anywhere in Canada. Ask us for the current lead time before you order and we will confirm it in writing.\"}},\n{\"@type\":\"Question\",\"name\":\"Can I get training or setup help?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Write to us and we will walk you through the first cycle.\"}}]}\n\u003c\/script\u003e\n\n\u003cp\u003e\u003cstrong\u003eHave a question about your own facility?\u003c\/strong\u003e Send it in and you will get a written answer specific to your setup, with the regulation or standard it is based on cited. \u003ca href=\"\/fr\/pages\/sterilization-compliance-consultation\"\u003eAsk your compliance question\u003c\/a\u003e.\u003c\/p\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":49011615105246,"sku":"CLI-ULTRA-CLEAN-62","price":699.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/c8cb08fe462564402afebc09af6419f1.png?v=1788971318","url":"https:\/\/clinieco.ca\/fr\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency","provider":"CliniEco Medical","version":"1.0","type":"link"}