{"product_id":"clinieco-ultrasonic-cleaner-20l-cs20-bench","title":"CliniEco Ultrasonic Cleaner — 20 L Bench Unit, CS20 with Heater and Drain Valve","description":"\u003cp\u003e\u003cstrong\u003eQuick answer:\u003c\/strong\u003e A 20 L chamber with eight transducers, 500 W of ultrasonic power and 500 W of heating — built for a clinic running several chairs, or a laboratory cleaning in batches.\u003c\/p\u003e\n\n\u003cp\u003eAt 20 L the tank stops being a bench accessory and becomes a station. The chamber is 42 × 26 × 20 cm, the unit is 54 × 37 × 40 cm and weighs 17 kg dry, and eight transducers are distributed under the floor so coverage holds across the full length rather than concentrating in the middle. It can sit on a counter or be installed recessed into one, which is usually how a multi-chair clinic handles a tank this size.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eScope of use.\u003c\/strong\u003e This is a cleaning device. It removes soil — cement residue, polishing paste, dried blood in hinges and threads — as a step in instrument reprocessing. It makes no microbicidal claim, and it does not replace any later step in the workflow set out in the instrument manufacturer’s instructions for use. The \u003ca href=\"https:\/\/www.canada.ca\/en\/health-canada\/services\/drugs-health-products\/medical-devices\/application-information\/guidance-documents\/guidance-document-information-manufacturers-sterilization-reusable-medical-devices.html\"\u003eHealth Canada guidance on reprocessing information\u003c\/a\u003e is why the instrument manufacturer’s instructions — not the cleaner’s specification sheet — decide what happens to a given instrument after it comes out of the tank.\u003c\/p\u003e\n\n\u003ch2\u003eWhat are the CS20 specifications?\u003c\/h2\u003e\n\n\u003cp\u003eThe two numbers that decide an installation are the loaded weight and the footprint: a 20 L working volume is roughly 20 kg of water plus a 17 kg unit.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eTank capacity:\u003c\/strong\u003e 20 L (5.3 US gal) — chamber 42 × 26 × 20 cm\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTransducers:\u003c\/strong\u003e 8, distributed across the tank floor\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e 500 W ultrasonic, 500 W heating, AC 100–120 V, North American plug\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eUnit dimensions:\u003c\/strong\u003e 54 × 37 × 40 cm; net weight 17 kg, gross 20 kg\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e Bench or recessed; noise-reduced cabinet, four-level circuit protection\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDrain:\u003c\/strong\u003e Electric drain valve\u003c\/p\u003e\u003ctable\u003e\n\u003ccaption\u003eCS20 — 20 L benchtop ultrasonic cleaner, specifications as supplied\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eField\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTank capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 L (5.3 US gal) — chamber 42 × 26 × 20 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTank dimensions\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e42 × 26 × 20 cm (length × width × depth)\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8, distributed across the tank floor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 W ultrasonic, 500 W heating, AC 100–120 V, North American plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54 × 37 × 40 cm; net weight 17 kg, gross 20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBench or recessed; noise-reduced cabinet, four-level circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectric drain valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ecETL — Intertek report 260210005GZU-001, to UL 73 and CSA C22.2 No. 68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnit, one-year manufacturer warranty; stainless basket available as an accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eList price\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAD $1,199.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eDoes this unit log cleaning cycles?\u003c\/h2\u003e\n\u003cp\u003eNo. The CS20 has no internal data logger and cannot export cycle data to a USB drive or a CSV file. If your reprocessing protocol requires machine-generated cycle records, choose a unit built for that purpose — this model is not one.\u003c\/p\u003e\n\u003cp\u003eWhat the CS20 gives you instead is everything needed to keep a defensible manual record: a front-panel timer that counts the cycle, a temperature set-point you can read and write down, and a drain valve so the solution-change date is unambiguous. Under CSA Z314:23 the documentation obligation sits inside your reprocessing quality system rather than inside the appliance, so a signed paper log is not a lesser record — it is the record the standard asks for.\u003c\/p\u003e\n\u003cp\u003eFive fields per cycle is enough: date, operator, temperature set-point, cycle length, and the date the solution was last changed. One line, end of shift.\u003c\/p\u003e\n\u003ch2\u003eWhich tank size in the range fits your room?\u003c\/h2\u003e\n\n\u003cp\u003eThis is the largest unit in the range and it is not the right unit for a two-chair practice. The sizes below it cover one chair, one cassette, or two chairs in one cycle; 20 L is for a room where the tank runs continuously or where instruments arrive in bulk.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eModel range as listed — tank, frequency and the load each size is built for\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eTank\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eBuilt for\u003c\/th\u003e\n\u003cth\u003eList price (CAD)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/fr\/products\/clinieco-ultrasonic-cleaner-4l-cs4-0-benchtop-dual-frequency\"\u003eCS4.0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 L\u003c\/td\u003e\n\u003ctd\u003e32 \/ 48 kHz\u003c\/td\u003e\n\u003ctd\u003eSingle chair, loose instruments\u003c\/td\u003e\n\u003ctd\u003e$449.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/fr\/products\/clinieco-ultrasonic-cleaner-cd4862-6l-dental\"\u003eCD-4862\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eFull cassette, five temperature presets\u003c\/td\u003e\n\u003ctd\u003e$649.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/fr\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003eCS6.2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L\u003c\/td\u003e\n\u003ctd\u003e32 \/ 48 kHz\u003c\/td\u003e\n\u003ctd\u003eFull cassette, dual frequency\u003c\/td\u003e\n\u003ctd\u003e$699.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/fr\/products\/clinieco-ultrasonic-cleaner-cd4875-7-5l-dental\"\u003eCD-4875\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eLarger trays, five temperature presets\u003c\/td\u003e\n\u003ctd\u003e$849.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/fr\/products\/clinieco-ultrasonic-cleaner-8l-cs8-0-benchtop\"\u003eCS8.0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e8 L\u003c\/td\u003e\n\u003ctd\u003e49 kHz\u003c\/td\u003e\n\u003ctd\u003eTwo chairs into one cycle\u003c\/td\u003e\n\u003ctd\u003e$999.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCS20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eSeveral chairs or batch work\u003c\/td\u003e\n\u003ctd\u003e$1,199.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003ePlan the bench before the unit arrives. A loaded 20 L tank is about 37 kg on a 54 × 37 cm footprint, and it needs to sit within reach of a drain or a container you are willing to carry. Recessing it removes the lifting problem and is the reason this model has a noise-reduced cabinet.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"\/fr\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/599bf33f4da20fb38d1771bb70a76d19.png?v=1792815581\" alt=\"Six litre benchtop ultrasonic cleaner, straight-on view of the unit with the lid closed\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch2\u003eHow do you run a repeatable cleaning cycle on the CS20?\u003c\/h2\u003e\n\n\u003cp\u003eA tank this size changes the workflow question from ‘does it fit the bench’ to ‘who owns the cycle’. One person should own the fill level, the solution change interval and the log.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eCycle set-up step by step\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStep\u003c\/th\u003e\n\u003cth\u003eSetting\u003c\/th\u003e\n\u003cth\u003eWhy it matters\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1. Fill\u003c\/td\u003e\n\u003ctd\u003e20 L working volume with solution at the label dilution\u003c\/td\u003e\n\u003ctd\u003eThe dose scales with the load, not with the tank shell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2. Heat\u003c\/td\u003e\n\u003ctd\u003eBring to the solution label temperature before the first load\u003c\/td\u003e\n\u003ctd\u003eA large tank takes longer to reach temperature; the first load is the one that gets rushed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3. Load\u003c\/td\u003e\n\u003ctd\u003eBaskets or trays, eight-transducer coverage across the length\u003c\/td\u003e\n\u003ctd\u003eEven spacing uses the whole floor instead of the centre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4. Run\u003c\/td\u003e\n\u003ctd\u003eFull cycle per load; do not add solution mid-cycle\u003c\/td\u003e\n\u003ctd\u003eAdding cold solution mid-cycle resets the working temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5. Drain, dry, record\u003c\/td\u003e\n\u003ctd\u003eElectric drain valve, dry the chamber, log the batch\u003c\/td\u003e\n\u003ctd\u003eBatch records are what a laboratory audit samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eThe failure mode on large tanks is drift: the level drops as baskets come out wet, someone tops it up with water, and after a week the concentration is half what the label says. Keep a marked fill line and change solution on a schedule, not on appearance.\u003c\/p\u003e\n\n\u003cp\u003eWhat an infection-control inspection asks for is the record, not the machine. Ontario’s provincial reprocessing guidance asks for \u003cem\u003edocumentation and maintenance of records for each component of the cleaning, disinfection and\/or sterilization process\u003c\/em\u003e, based on the manufacturer’s recommendations, and repeats that records \u003cem\u003emust be retained according to the facility’s policy\u003c\/em\u003e (\u003ca href=\"https:\/\/www.publichealthontario.ca\/-\/media\/Documents\/B\/2013\/bp-cleaning-disinfection-sterilization-hcs.pdf?rev=074097c0ef2343379b7bb17d97b75526\u0026amp;sc_lang=en\"\u003ePublic Health Ontario, “Best Practices for Cleaning, Disinfection and Sterilization of Medical Equipment\/Devices In All Health Care Settings”, 3rd edition, checked 2026-11-07\u003c\/a\u003e). A unit with a drain valve, a visible timer and a stable temperature set-point is what makes that record short enough to write at the end of a shift.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does the cETL mark cover, and what does it not?\u003c\/h2\u003e\n\n\u003cp\u003eThe CS20 sits under a different Intertek report from the smaller units — 260210005GZU-001 — which is the number to quote if a technician or an inspector asks which certificate covers this family. The mark on the unit is an ETL mark issued by Intertek, tested against \u003ca href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL73\"\u003eUL 73\u003c\/a\u003e and \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/C22.2%20NO.%2068-18\/\"\u003eCSA C22.2 No. 68\u003c\/a\u003e. It is an electrical safety certificate. It is not a UL listing and it is not CSA certification, and it says nothing about how well the tank cleans. Canadian reprocessing practice sits on a separate standard, \u003ca href=\"https:\/\/store.csastandards.org\/store\/product\/2430344\/\"\u003eCSA Z314:23\u003c\/a\u003e, whose scope puts documentation inside the reprocessing quality system rather than inside the appliance.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eWhat the electrical certificate covers, and what it does not\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCovers\u003c\/th\u003e\n\u003cth\u003eDoes not cover\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical safety of the appliance, assessed to UL 73 and CSA C22.2 No. 68\u003c\/td\u003e\n\u003ctd\u003eCleaning performance on your instruments, on your water hardness, or at your solution concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe specific unit family named on Intertek report 260210005GZU-001\u003c\/td\u003e\n\u003ctd\u003eThe condition of an individual unit after a drop, a repair, or a modification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance of the supply, plug and cord assembly for the North American market\u003c\/td\u003e\n\u003ctd\u003eAny clinical outcome, or any claim that the unit removes or inactivates micro-organisms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe identity of the certificate holder and the factory it was issued to\u003c\/td\u003e\n\u003ctd\u003eYour own reprocessing records, which are yours to keep and produce\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\n\u003ch2\u003eWhat is in the box, and what should be ordered with it?\u003c\/h2\u003e\n\n\u003cp\u003eOne cleaner, 20 L, 110 V with a North American plug and the manufacturer warranty. Basket as an accessory. Because the unit can be recessed, confirm the cut-out dimensions with us before the bench is built rather than after.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"\/fr\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003eMulti-enzyme ultrasonic cleaning solution\u003c\/a\u003e is what goes in the tank, sold as a 1 L bottle or a 5 L pail and diluted 1:400 to 1:600. The \u003ca href=\"\/fr\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003e6 L CS6.2\u003c\/a\u003e is the unit to look at if your load grows into full cassettes. Read \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/choosing-ultrasonic-cleaner-tank-size-canadian-dental-clinic\"\u003ehow to choose a tank size\u003c\/a\u003e and \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/what-should-a-canadian-clinic-record-for-ultrasonic-cleaning-log-fields-and-retention\"\u003ewhat to record on the cleaning log\u003c\/a\u003e before you commit to a size.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does one tank fill cost in cleaning solution?\u003c\/h2\u003e\n\u003cp\u003eAt 20 L the chemistry line stops being a rounding error and starts being a purchasing decision: a full tank takes about 50 mL at 1:400, a 1 L bottle gives twenty fills and a 5 L pail a hundred. That is why batch work is costed per tank rather than per instrument — the fill, not the piece, is the unit of spend.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCS20 — concentrate per full tank and pack yield at the two label dilutions\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eDilution on the label\u003c\/th\u003e\n\u003cth\u003eConcentrate per full tank (20 L)\u003c\/th\u003e\n\u003cth\u003eFills from a 1 L bottle\u003c\/th\u003e\n\u003cth\u003eFills from a 5 L pail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1:400 — heavier soil\u003c\/td\u003e\n\u003ctd\u003e≈ 50 mL\u003c\/td\u003e\n\u003ctd\u003e20 fills\u003c\/td\u003e\n\u003ctd\u003e100 fills\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1:600 — light soil\u003c\/td\u003e\n\u003ctd\u003e≈ 33.3 mL\u003c\/td\u003e\n\u003ctd\u003e30 fills\u003c\/td\u003e\n\u003ctd\u003e150 fills\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCost per fill = the current pack price divided by the fills in that pack. Both halves of that sum move — the pack price with the market, the fills with how full you run the tank — which is why the page gives the arithmetic instead of a per-cycle figure. If your protocol changes the bath once per working day, five days a week, 20 fills is roughly 4 working weeks from one bottle.\u003c\/p\u003e\n\n\u003ch2\u003eWhich cleaning solution goes in this tank, and when should it be changed?\u003c\/h2\u003e\n\u003cp\u003eThe 20 L chamber takes the \u003ca href=\"\/fr\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003emulti-enzyme ultrasonic cleaning concentrate\u003c\/a\u003e in 1 L bottles or 5 L pails at 1:400 to 1:600. A larger tank holds a larger free surface, so the low-foam formulation is doing real work here: foam that would be a nuisance in a 4 L bath can blanket a 20 L one. Label window: 20–50 °C, 2 to 10 minutes, 24 months sealed, 90 days open.\u003c\/p\u003e\n\u003cp\u003eChange the bath when the label and your protocol say to, and record the change as part of the cleaning record — the electric drain valve on this unit exists so that a 20 L change is a routine task rather than a two-person one. Ontario reprocessing guidance asks for \u003cem\u003edocumentation and maintenance of records for each component of the cleaning, disinfection and\/or sterilization process\u003c\/em\u003e (\u003ca href=\"https:\/\/www.publichealthontario.ca\/-\/media\/Documents\/B\/2013\/bp-cleaning-disinfection-sterilization-hcs.pdf?rev=074097c0ef2343379b7bb17d97b75526\u0026amp;sc_lang=en\"\u003ePublic Health Ontario provincial reprocessing guidance, 3rd edition, checked 2026-11-07\u003c\/a\u003e).\u003c\/p\u003e\n\n\u003ch2\u003eWhat is the lead time, and what maintenance does the unit need?\u003c\/h2\u003e\n\u003cp\u003eThis unit is built to order — allow 3–4 weeks, and we confirm the dispatch date before it ships. The manufacturer warranty runs one year and is supported in Canada. CliniEco Medical holds Health Canada establishment licence (MDEL) #35334 — importer and distributor — which is separate from the warranty terms. What the unit asks of you in return is short, and mostly about the bath rather than the electronics.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCS20 — routine maintenance and why each item is on the list\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTask\u003c\/th\u003e\n\u003cth\u003eInterval\u003c\/th\u003e\n\u003cth\u003eWhy it matters\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain and refill\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAt the interval the solution label and your protocol set\u003c\/td\u003e\n\u003ctd\u003eSoil load accumulates in the bath whatever the instruments look like when they come out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRun a fresh fill before the first load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery refill\u003c\/td\u003e\n\u003ctd\u003eDissolved air in new solution damps cavitation, and the bath should be at working temperature before an instrument goes in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRinse tank and basket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery change\u003c\/td\u003e\n\u003ctd\u003eResidue left on stainless carries soil into the next fill and films the tank over time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWipe lid and check cord, plug and drain valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003ctd\u003eThe three parts a drop or a wipe-down damages first\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeep the level above the working minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery cycle\u003c\/td\u003e\n\u003ctd\u003eRunning dry is the one failure mode that ends a tank’s service life early\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWith eight transducers across the tank floor, a full tank is also a steadier tank: filling to the working level keeps the load immersed and the field even, and never letting the level fall onto the heaters is the one rule that protects the unit.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRelated reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/choosing-ultrasonic-cleaner-tank-size-canadian-dental-clinic\"\u003eChoosing an Ultrasonic Cleaner Tank Size for a Canadian Dental Clinic\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/verifying-instrument-cleaning-protein-residue-tests-tosi-and-cavitation-methods-compared\"\u003eVerifying Instrument Cleaning: Protein Residue Tests, TOSI and Cavitation Methods\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/how-much-does-an-ultrasonic-cleaner-cost-in-canada-2026-price-bands-for-clinics\"\u003eHow Much Does an Ultrasonic Cleaner Cost in Canada? 2026 Price Bands\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCliniEco Medical is a licensed medical device establishment (MDEL #35334). We are the Canadian importer of record for this unit: duties and brokerage are handled on our side, and you receive it from our Toronto warehouse with a one-year manufacturer warranty supported in Canada. Questions on which size fits your room go to our \u003ca href=\"\/fr\/pages\/sterilization-compliance-consultation\"\u003esterilization desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt to order.\u003c\/strong\u003e Allow 3–4 weeks — we confirm the dispatch date before the unit ships.\u003c\/p\u003e","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":49376919781598,"sku":"CLI-ULTRA-CLEAN-200","price":1199.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CS20-HERO-logo-20261110_4db852d0-c1a2-4d5e-9a7f-5206ad0554ee_50015df7-4404-418f-ae60-9fd8ef44a91c.jpg?v=1794342778","url":"https:\/\/clinieco.ca\/fr\/products\/clinieco-ultrasonic-cleaner-20l-cs20-bench","provider":"CliniEco Medical","version":"1.0","type":"link"}