{"product_id":"clinieco-medical-specimen-bags-8-10-inch-95kpa-certified-100-pack","title":"CliniEco Medical UN3373 Specimen Transport Bags — 8×10\", 95 kPa, Document Pouch \u0026 Absorbent Pad, 100-Pack","description":"\u003ch3\u003eThe larger bag, for when a 6 × 9 is too tight\u003c\/h3\u003e\n\u003cp\u003e8 × 10 inches (203 × 254 mm) is the second size you should keep on the shelf. It exists for the load that does not fit a standard bag: multiple blood tubes for one patient, larger urine or sputum containers, tissue pots, and anything that would otherwise be forced into a bag with no room left for the absorbent layer to do its job.\u003c\/p\u003e\n\u003cp\u003eAn over-filled bag is a compliance problem, not just an inconvenience — if the inner pouch is stretched against the outer wall, there is no absorbent capacity left to absorb a leak.\u003c\/p\u003e\n\u003cp\u003eWhichever specimen collection workflow you run — venous blood, urine, swabs, tissue or cytology — the sample leaves the room in one of these bags, with the request form kept in the separate document pouch.\u003c\/p\u003e\n\u003ch3\u003eSpecifications you can hold us to\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e8 × 10 in (203 × 254 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eThree-wall — specimen pouch, absorbent layer, outer wall with document pouch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eAbsorbent layer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eBuilt in, per P650 (7)(d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003ePressure performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e95 kPa, per P650 (7)(e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eMarking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eUN3373 and biohazard marking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003ePack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e100 per box · 10 boxes per case (1,000 bags)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eImporter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eCliniEco Medical — Health Canada MDEL #35334\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhen to choose 8 × 10 rather than 6 × 9\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eMore than two or three tubes from one patient\u003c\/strong\u003e travelling together.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eLarger container formats\u003c\/strong\u003e — wide-mouth urine pots, sputum containers, some stool kits.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eTissue and histology specimens\u003c\/strong\u003e that come in their own pot and need clearance around them.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eAny load where you are currently folding or forcing\u003c\/strong\u003e a specimen into a bag. That is the signal that you need this size. Folding a bag also folds the absorbent layer, and folded absorbent does not absorb.\u003c\/p\u003e\n\n\u003ch3\u003eWhat UN3373 and 95 kPa actually mean\u003c\/h3\u003e\n\u003cp\u003eThis is the part most listings get wrong, so here it is properly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUN3373 is a transport classification, not a product feature.\u003c\/strong\u003e It covers Category B biological substances — the human or animal specimens that move between a clinic, a laboratory and a referral lab every day. The packaging rules for Category B are set out in \u003cstrong\u003eADR P650\u003c\/strong\u003e (and IATA 650 for air), and they are what this bag is built for.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e95 kPa is a performance requirement, not a material.\u003c\/strong\u003e P650 (7)(e) says the primary receptacle or the secondary packaging must withstand, without leakage, an internal pressure of 95 kPa. That is a test the packaging has to pass. It does not tell you what the bag is made of, and a bag is not \"95 kPa\" the way it is \"polyethylene\". Any supplier who cannot explain that distinction is selling you a word, not a specification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe absorbent pad is not a free upgrade — it is required.\u003c\/strong\u003e P650 (7)(d) requires absorbent material to be placed between the primary receptacle and the secondary packaging, sufficient to absorb the entire liquid content. That is why our bags have one built in. If you are buying a specimen bag without an absorbent layer, check what you are relying on for compliance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eP650 does not require a design-type approval or a certificate.\u003c\/strong\u003e The obligation sits with the shipper. A test report is commercial evidence and is genuinely useful, but a supplier claiming the regulation \"requires a certificate\" is mis-stating it.\u003c\/p\u003e\n\u003ch3\u003eWhat we can state plainly\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eThe pressure test figure is 95 kPa, per P650 (7)(e).\u003c\/strong\u003e Named, and quotable.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eAn absorbent layer is built in, per P650 (7)(d).\u003c\/strong\u003e Not an optional extra.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eWe stock and ship from Toronto, Ontario.\u003c\/strong\u003e We are the importer of record: Ecology Source New Energy Technology Co., LTD. o\/a CliniEco Medical, Health Canada MDEL #35334.\u003c\/p\u003e\n\u003ch3\u003eThe documentation we hold — and how to check it\u003c\/h3\u003e\n\u003cp\u003eOur specimen bags are built to \u003cstrong\u003eADR \/ IATA P650\u003c\/strong\u003e, which is the rule set that governs Category B biological substances in transport. In practice that means two things are built in as standard: the \u003cstrong\u003eabsorbent material\u003c\/strong\u003e that P650 \u003cstrong\u003e(7)(d)\u003c\/strong\u003e requires between the primary receptacle and the secondary packaging, and a construction that meets the \u003cstrong\u003e95 kPa\u003c\/strong\u003e internal pressure performance requirement in \u003cstrong\u003eP650 (7)(e)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest documentation is held per size.\u003c\/strong\u003e P650 itself does not require a design-type approval or a certificate, and any supplier who tells you it does is mis-stating the regulation. Reports are commercial evidence, and they are genuinely useful when you need to satisfy a laboratory or an auditor. So: \u003cstrong\u003eask us which sizes we hold test reports for, and we will tell you exactly what we have before you order.\u003c\/strong\u003e We would rather you ask a direct question and get a direct answer than buy on the strength of a word.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat matters more, and is often missed:\u003c\/strong\u003e the report has to identify the item it tested. ISO\/IEC 17025 §7.8 requires a test report to uniquely identify the sample tested. A report that names a model number but not a size does not demonstrate performance for a size you are buying. If you are relying on a report for an audit, check that it names the size on the face of the document.\u003c\/p\u003e\n\n\u003cp\u003e• \u003cstrong\u003eIf a different size suits your specimens better, we will say so\u003c\/strong\u003e — including pointing you to a larger bag if that is the honest answer.\u003c\/p\u003e\n\u003ch3\u003eWhy buy specimen transport bags from us rather than a general supplier\u003c\/h3\u003e\n\u003cp\u003eTransport packaging is a compliance question, not a stationery question. A clinic that gets it wrong is the one that carries the exposure, and the laboratory receiving a leaking or non-conforming sample is entitled to reject it and ask for a repeat. We sell this line because we can explain the rules, name the clause, explain what a test report does and does not prove, and tell you what to write on the paperwork. Most sellers of \"95 kPa bags\" cannot do any of those four things.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering.\u003c\/strong\u003e Ships from Toronto. Tell us your specimen volumes and route, and we will confirm the right size and pack in writing before you commit.\u003c\/p\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Single Box","offer_id":49082380386526,"sku":"CLI-BAG-UN3373-8X10-100","price":349.0,"currency_code":"CAD","in_stock":true},{"title":"Bulk 10-Box","offer_id":49082380452062,"sku":"CLI-BAG-UN3373-8X10-1000","price":1990.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CLI-BAG-UN3373-8X10-100-01_photo-main.png?v=1790491680","url":"https:\/\/clinieco.ca\/fr\/products\/clinieco-medical-specimen-bags-8-10-inch-95kpa-certified-100-pack","provider":"CliniEco Medical","version":"1.0","type":"link"}