{"title":"Pipetting \u0026 Transfer","description":"\u003cp\u003eTransfer pipettes, serological pipettes and parafilm for moving and sealing small volumes.\u003c\/p\u003e\n\u003cp\u003eEight packs cover the routine work between a pipettor and a bottle: transfer pipettes from 1.5 mL for microtubes up to 7 mL for a 15 mL tube, exact volume pipettes from 20 to 500 microlitre, 4.5 mL blood bank pipettes graduated to 2 mL, and a lab consumables pack that carries sealing film and serological pipettes.\u003c\/p\u003e\n\u003ch2\u003eWhich transfer pipette volume fits a 15 mL tube or a microtube?\u003c\/h2\u003e\n\u003cp\u003eA \u003ca href=\"\/fr\/products\/mtc-bio-7-ml-transfer-pipettes-large-bulb-graduated-to-3-ml-sterile-or-bulk\"\u003e7 mL transfer pipette with a large bulb, graduated to 3 mL\u003c\/a\u003e reaches the bottom of a 15 mL tube and a 120 mL specimen container without a second vessel. For a microtube or a cryogenic vial, the 1.5 mL pipette with a small bulb and an extended tip fits a narrow neck where a 5 mL body will not pass.\u003c\/p\u003e\n\u003cp\u003eBoth formats sit on a one-piece polyethylene body, so there is no separate bulb to lose. The graduated 7 mL version marks 1, 2 and 3 mL for a measured transfer.\u003c\/p\u003e\n\u003ch2\u003eHow many transfer pipettes are in a pack or a case?\u003c\/h2\u003e\n\u003cp\u003ePack counts follow the volume and the format rather than the stem length. The 3 mL, 4.5 mL, 5 mL and 7 mL ranges hold 250 pipettes per pack in 20 packs, so 5,000 per case, in the non-sterile working pack. The 1.5 mL pipette holds 500 per pack in six packs, so 3,000, and the extended-tip 7 mL holds 400 in ten, so 4,000.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eVolume and format\u003c\/th\u003e\n\u003cth\u003eTip or bulb\u003c\/th\u003e\n\u003cth\u003ePack count\u003c\/th\u003e\n\u003cth\u003eBench use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/fr\/products\/mtc-bio-1-5-ml-transfer-pipettes-small-bulb-extended-tip-sterile-or-bulk\"\u003e1.5 mL transfer pipette\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSmall bulb, extended tip\u003c\/td\u003e\n\u003ctd\u003e500 per pack, 3,000 per case\u003c\/td\u003e\n\u003ctd\u003eMicrotubes, cryogenic vials, narrow-neck containers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/fr\/products\/mtc-bio-3-ml-transfer-pipettes-short-bulb-graduated-to-1-ml\"\u003e3 mL transfer pipette\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eShort bulb, graduated to 1 mL\u003c\/td\u003e\n\u003ctd\u003e250 per pack, 5,000 per case\u003c\/td\u003e\n\u003ctd\u003eRack-side additions where a 5 mL body stands too tall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/fr\/products\/mtc-bio-4-ml-transfer-pipettes-short-stem-or-standard-sterile-or-bulk-packs\"\u003e4 mL transfer pipette\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eShort stem or standard stem\u003c\/td\u003e\n\u003ctd\u003e250 or 500 per pack, up to 5,000 per case\u003c\/td\u003e\n\u003ctd\u003eShallow vessel on one side, deep tube on the other\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/fr\/products\/mtc-bio-4-5-ml-blood-bank-transfer-pipettes-graduated-to-2-ml\"\u003e4.5 mL blood bank pipette\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBlood bank shape, graduated to 2 mL\u003c\/td\u003e\n\u003ctd\u003e250 per pack, 5,000 per case\u003c\/td\u003e\n\u003ctd\u003eSerology and transfusion service steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/fr\/products\/mtc-bio-5-ml-transfer-pipettes-large-bulb-sterile-or-bulk-graduated-options\"\u003e5 mL transfer pipette\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eLarge bulb, standard or extended tip\u003c\/td\u003e\n\u003ctd\u003e250 or 500 per pack, 5,000 per case\u003c\/td\u003e\n\u003ctd\u003eSpecimen containers, reagent addition, strip work\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7 mL transfer pipette\u003c\/td\u003e\n\u003ctd\u003eLarge bulb, graduated to 3 mL\u003c\/td\u003e\n\u003ctd\u003e250 or 400 per pack, 4,000 to 5,000 per case\u003c\/td\u003e\n\u003ctd\u003e15 mL tubes and 120 mL containers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/fr\/products\/mtc-bio-exact-volume-transfer-pipettes-20-to-500-microlitre-sterile-bags\"\u003e20 to 500 microlitre exact volume pipette\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed bulb, stem length matched to volume\u003c\/td\u003e\n\u003ctd\u003e1,000 to 5,000 per case in resealable bags\u003c\/td\u003e\n\u003ctd\u003eFixed-volume reagent steps without a pipettor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSterile formats are counted per case rather than per pack: individually wrapped packs hold 500 per case across the range, and peel packs of 20 also make 500 per case.\u003c\/p\u003e\n\u003ch2\u003eShould a laboratory buy sterile individually wrapped pipettes or non-sterile working packs?\u003c\/h2\u003e\n\u003cp\u003eUse the non-sterile working pack where the pipette is a transfer tool on a staining, dilution or reagent bench. Use the sterile individually wrapped format where the step has to come from an unopened wrapper: cell work, microbiology, and any step a transfusion service documents. Both configurations share the same body and graduation, so the choice is the sterile claim rather than the shape.\u003c\/p\u003e\n\u003ch2\u003eHow do you choose between a short stem and a standard stem?\u003c\/h2\u003e\n\u003cp\u003eA short stem fits a shallow vessel, a small rack and a tight rack position where a long pipette would tip the container or touch the bench. The standard stem reaches the bottom of a 15 mL tube or a deep container, and it is the format a dispensary uses for decanting from a bottle. Because both are 4 mL, the decision is reach rather than volume.\u003c\/p\u003e\n\u003cp\u003eThe same question decides the tip on a 5 mL pipette: the standard tip covers a specimen container, and the extended tip reaches a narrow vessel the standard tip cannot enter.\u003c\/p\u003e\n\u003ch2\u003eWhen is an exact volume pipette worth it instead of a graduated one?\u003c\/h2\u003e\n\u003cp\u003eExact volume earns its place where a step depends on a repeatable small volume and a pipettor is unavailable or slower than the task: adding a fixed reagent to a strip, inoculating a fixed volume into broth, transferring a stain. The bulb is moulded to one volume, so the draw stops at that volume and the operator does not watch a graduation.\u003c\/p\u003e\n\u003cp\u003eThe range runs from 20 microlitre at 53 mm to 500 microlitre at 120 mm, with stem length matched to volume. The 20 to 100 microlitre band covers most fixed-volume steps, and 150 to 500 microlitre covers larger reagent additions. Bag counts shrink as the bulb grows: 5,000 pipettes in ten bags at 20 microlitre, 2,500 in five bags from 50 to 250 microlitre, and 1,000 in two bags from 300 to 500 microlitre.\u003c\/p\u003e\n\u003ch2\u003eWhat does a blood bank pipette do that a standard transfer pipette does not?\u003c\/h2\u003e\n\u003cp\u003eA blood bank pipette is a shape rather than a volume: long enough to reach into a segment or a tube, graduated to 2 mL so a plasma or cell suspension volume can be read in the pipette itself, and sized at 4.5 mL so a full draw covers a typical serology step. The sterile pack is wrapped individually rather than in peel packs, which suits a clean field.\u003c\/p\u003e\n\u003ch2\u003eHow should transfer pipettes be stored at the bench?\u003c\/h2\u003e\n\u003cp\u003eA 250-pipette pack fits a bench drawer, which keeps the working pack out of the carton and away from water on the bench. Non-sterile formats are bagged rather than boxed, so a pack can sit in a beaker without the carton taking water, and the sterile formats carry the lot on the outside of the sealed bag.\u003c\/p\u003e\n\u003ch2\u003eWhere can a Canadian laboratory order transfer pipettes by the case?\u003c\/h2\u003e\n\u003cp\u003eWhere to order in Canada is the \u003ca href=\"\/fr\/collections\/b2b-wholesale\"\u003ecase and volume supply collection\u003c\/a\u003e, which carries the same pack and case units listed here, and each product page shows the pack count in its variant list. Every format ships from North American stock. For a year of bench supply, \u003ca href=\"\/fr\/pages\/clinic-supply-planner\"\u003ethe clinic supply planner\u003c\/a\u003e converts weekly use into cases before you order.\u003c\/p\u003e\n\u003cp\u003eTwo pages answer the specification questions that come up at order time: \u003ca href=\"\/fr\/blogs\/medical-supply-guide\/serological-pipettes-canada-vs-us-which-class-and-colour-code\"\u003ethe class and colour code for serological pipettes\u003c\/a\u003e and \u003ca href=\"\/fr\/blogs\/medical-supply-guide\/parafilm-laboratory-sealing-films-canada-vs-us\"\u003ethe rules for laboratory sealing film\u003c\/a\u003e. Both product families sit in one pack here: \u003ca href=\"\/fr\/products\/clinieco-lab-consumables-parafilm-pipettes\"\u003eCliniEco lab consumables with parafilm and serological pipettes\u003c\/a\u003e.\u003c\/p\u003e\n","products":[{"product_id":"clinieco-lab-consumables-parafilm-pipettes","title":"CliniEco Lab Consumables — Parafilm \u0026 Serological Pipettes","description":"\u003cp\u003eCliniEco Lab Consumables — Parafilm \u0026amp; Serological Pipettes\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNotes:\u003c\/strong\u003e Specifications, packaging and pricing shown are indicative and will be confirmed before launch. No therapeutic claims are made on this page.\u003c\/p\u003e\u003cp\u003eCliniEco Medical · Imported and distributed in Canada by Ecology Source New Energy Technology Co., LTD. · Health Canada MDEL #35334\u003c\/p\u003e\n\u003csection class=\"clinieco-answers\"\u003e\n\u003ch2\u003eWhat is laboratory sealing film used for?\u003c\/h2\u003e\n\u003cp\u003eSealing film closes the neck of a flask, the rim of a plate or the joint of a tube so the contents do not evaporate or pick up contamination. It stretches over the opening and clings by contact rather than by adhesive. It is a closure, not a pressure seal, and it is not a substitute for a ground-glass joint or a screw cap under vacuum.\u003c\/p\u003e\n\u003ch2\u003eHow do you read a serological pipette's volume and colour band?\u003c\/h2\u003e\n\u003cp\u003eRead the volume from the printed scale and the graduation, and read the colour band as a manufacturer's convention rather than a standard, because brands do not all use the same colour for the same volume. What is standardised is the calibration: a serological pipette is calibrated to deliver, which is why the last drop behaves the way it does.\u003c\/p\u003e\n\u003ch2\u003eWhy does a serological pipette over-deliver, and what is blow-out?\u003c\/h2\u003e\n\u003cp\u003eA to-deliver pipette is calibrated so that the volume left clinging to the inside of the tip is excluded from the marked volume. If the last drop is blown out, more liquid is dispensed than the mark states. That is why some protocols specify blow-out and others forbid it, and why the instruction on the pipette or its certificate is the figure to follow.\u003c\/p\u003e\n\u003ch2\u003eAre laboratory consumables medical devices in Canada?\u003c\/h2\u003e\n\u003cp\u003eConsumables that do not contact a patient and carry no clinical claim sit outside the medical device framework, so there is no licence number to ask for. What applies instead is the laboratory's own quality system: lot traceability, a certificate of analysis where the assay depends on it, and the laboratory's written procedure for the item. Ask for the lot, not for a licence.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eFormat \/ size\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003cth\u003eTypical use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealing film\u003c\/td\u003e\n\u003ctd\u003eRoll, cut to length\u003c\/td\u003e\n\u003ctd\u003eWax-paraffin film\u003c\/td\u003e\n\u003ctd\u003eSealing flasks, plates, tube joints\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerological pipette\u003c\/td\u003e\n\u003ctd\u003eIndividually wrapped, graduated\u003c\/td\u003e\n\u003ctd\u003ePolystyrene or glass\u003c\/td\u003e\n\u003ctd\u003eMeasuring and transferring liquid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipette aid\u003c\/td\u003e\n\u003ctd\u003ePer piece\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eDrawing liquid into the pipette\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eLaboratory and clinic enquiries: \u003ca href=\"\/fr\/pages\/wholesale\"\u003einstitutional account enquiry page\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eLast reviewed: 2026-11\u003c\/em\u003e\u003c\/p\u003e\u003c\/section\u003e\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/serological-pipettes-canada-vs-us-which-class-and-colour-code\"\u003eSerological Pipettes in Canada vs the US: Which Class and Colour Code Apply?\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/serological-pipette-over-delivery-blow-out-drainage\"\u003eWhy Serological Pipettes Over-Deliver: Blow-Out and Drainage\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/parafilm-laboratory-sealing-films-canada-vs-us\"\u003eParafilm and Laboratory Sealing Films in Canada vs the US: Which Rules Apply?\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":49136038510814,"sku":"CLI-LAB-CONS","price":49.99,"currency_code":"CAD","in_stock":true}]},{"product_id":"mtc-bio-7-ml-transfer-pipettes-large-bulb-graduated-to-3-ml-sterile-or-bulk","title":"MTC Bio 7 mL Transfer Pipettes, Large Bulb, Graduated to 3 mL, Sterile or Bulk","description":"\u003cp\u003e\u003cstrong\u003eMTC Bio 7 mL transfer pipettes with a large bulb graduated to 3 mL,\u003c\/strong\u003e in bulk packs of 250 to 400 and up to 4,000 per case, shipped from North American stock.\u003c\/p\u003e\n\u003cp\u003eSeven millilitres is the size that fits a 15 mL tube and a 120 mL specimen container without a second vessel. This range keeps the large bulb and the graduation to 3 mL, so a technician can move a measured 1, 2 or 3 mL without picking up a pipettor, and offers the standard tip or the extended tip for narrow vessels. Sterile formats cover cell work and microbiology; bulk non-sterile covers staining and reagent handling.\u003c\/p\u003e\n\u003ch2\u003eWhat is in a case of 7 mL transfer pipettes?\u003c\/h2\u003e\n\u003cp\u003eBulk non-sterile configurations hold 250 pipettes per pack in 20 packs, so 5,000 per case, or 400 per pack in 10 packs for the extended tip version, so 4,000 per case. Sterile peel-pack configurations hold 500 per case in packs of 20, and individually wrapped sterile holds 500 per case.\u003c\/p\u003e\n\u003cp\u003eThe graduation marks are at 1, 2 and 3 mL on the graduated configurations; the ungraduated extended-tip line is for transfer only.\u003c\/p\u003e\n\u003ch2\u003eStandard tip or extended tip, and which pack format?\u003c\/h2\u003e\n\u003cp\u003eThe standard tip suits wide-mouth containers: a beaker, a specimen container, a basin. The extended tip is longer and narrower so it reaches into a 15 mL tube or a narrow-neck bottle without the bulb touching the rim, and it is the format a dispensary usually keeps for decanting.\u003c\/p\u003e\n\u003cp\u003ePack format follows the sterile need: bulk for non-sterile reagent work, peel packs of 20 where a bench wants the rest of the pack covered, individual wraps where traceability to an unopened wrapper matters in an audit.\u003c\/p\u003e\n\u003ch2\u003eWhat are the specifications?\u003c\/h2\u003e\n\u003cp\u003eEvery configuration below is a separate case line. The manufacturer reference is what appears on the quotation, the packing slip and the lot documentation, so quote it when you ask for a certificate of analysis.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eManufacturer reference\u003c\/th\u003e\n\u003cth\u003ePack\u003c\/th\u003e\n\u003cth\u003eCase\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 7mL · large bulb · graduated to 3mL · non-sterile ·\u003c\/td\u003e\n\u003ctd\u003eP4114-00\u003c\/td\u003e\n\u003ctd\u003e250 per pack\u003c\/td\u003e\n\u003ctd\u003e5,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 7mL · large bulb · graduated to 3mL · sterile · ind\u003c\/td\u003e\n\u003ctd\u003eP4114-11\u003c\/td\u003e\n\u003ctd\u003e500 per pack\u003c\/td\u003e\n\u003ctd\u003e500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 7mL · large bulb · graduated to 3mL · sterile · pee\u003c\/td\u003e\n\u003ctd\u003eP4114-14\u003c\/td\u003e\n\u003ctd\u003e500 per pack\u003c\/td\u003e\n\u003ctd\u003e3,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 7mL · large bulb · extended tip · non-sterile · bul\u003c\/td\u003e\n\u003ctd\u003eP4123-01\u003c\/td\u003e\n\u003ctd\u003e400 per pack\u003c\/td\u003e\n\u003ctd\u003e4,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 7mL · large bulb · extended tip · sterile · individ\u003c\/td\u003e\n\u003ctd\u003eP4123-11\u003c\/td\u003e\n\u003ctd\u003e500 per pack\u003c\/td\u003e\n\u003ctd\u003e500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHow many 7 mL pipettes does a lab get through?\u003c\/h2\u003e\n\u003cp\u003eA specimen-handling bench processing 40 containers a day uses one pipette per container, so about 850 a month; a 4,000-pipette case lasts four to five months. A sterile cell-culture bench using 10 sterile pipettes a day uses about 210 a month, and a 500-count sterile case lasts two to three months.\u003c\/p\u003e\n\u003cp\u003eThe graduation is the reason most labs standardise on this size: one pipette covers the 1 to 3 mL transfers that otherwise need two different tools. Keep one pack of each tip style open at the bench if the bench does both wide-mouth and narrow-mouth work, because walking to a cupboard for the other tip is where a pipette gets reused.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eWorking pattern\u003c\/th\u003e\n\u003cth\u003eUsed per month\u003c\/th\u003e\n\u003cth\u003eCase covers\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne bench, light use\u003c\/td\u003e\n\u003ctd\u003eabout 300 pieces\u003c\/td\u003e\n\u003ctd\u003eroughly 8 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne bench, full shift\u003c\/td\u003e\n\u003ctd\u003eabout 2,000 pieces\u003c\/td\u003e\n\u003ctd\u003eroughly 2 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwo benches\u003c\/td\u003e\n\u003ctd\u003eabout 4,000 pieces\u003c\/td\u003e\n\u003ctd\u003eunder one month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCounts above are planning figures from pack and case sizes on this page, not a forecast of your own consumption; check them against a week of your own bench records before setting a reorder point.\u003c\/p\u003e\n\u003ch2\u003eHow is it shipped, and how should it be stored?\u003c\/h2\u003e\n\u003cp\u003ePipettes ship from North American stock, 1 to 2 business days in Ontario, 2 to 4 across Canada and 2 to 3 to US addresses. Sterile formats carry the manufacturer reference and lot on the pack, and sterilisation documentation is available on request against the reference. Bulk cases are shipped in a double-wall carton that can be kept as the storage box once opened, provided it stays closed between uses.\u003c\/p\u003e\n\u003cp\u003eKeep the case closed and out of heat. A polyethylene bulb that has been left in a warm vehicle or on a windowsill loses its shape and will not deliver the marked volume.\u003c\/p\u003e\n\u003cp\u003eOne practical check before the first case: draw water to the 3 mL mark and compare it with a graduated cylinder. The mark is a moulded estimate, so if a step depends on it, record the difference once and write it into the SOP instead of rediscovering it at the bench.\u003c\/p\u003e\n\u003ch2\u003eWhat we do not claim\u003c\/h2\u003e\n\u003cp\u003eSingle-use laboratory consumables for liquid transfer. Not sold as medical devices for patient treatment. Graduation is a moulded estimate rather than a calibrated measurement; sterility is the manufacturer's stated value per configuration.\u003c\/p\u003e\n\u003cp\u003eWhat we cannot do is confirm the delivered volume of an uncalibrated pipette: if a step needs a measured volume, send us the tolerance and we will say which tool in this range fits.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eHow much is a bulk case?\u003c\/summary\u003e\u003cp\u003eStand ard tip bulk holds 250 per pack and 20 packs per case, so 5,000; the extended tip bulk holds 400 per pack and 10 packs per case, so 4,000.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eDoes the 7 mL pipette fit a 15 mL tube?\u003c\/summary\u003e\u003cp\u003eThe standard tip reaches into a 15 mL tube but the extended tip is the version that reaches the bottom without the bulb touching the rim.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs the graduation to 3 mL calibrated?\u003c\/summary\u003e\u003cp\u003eNo, it is a moulded estimate at 1, 2 and 3 mL for transfer work; a protocol that needs a measured volume should use a calibrated tool.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eAre sterile pipettes available individually wrapped?\u003c\/summary\u003e\u003cp\u003eYes, the individually wrapped sterile configuration ships 500 per case, and the peel-pack sterile configuration also ships 500 per case in packs of 20.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I mix sterile and bulk in one order?\u003c\/summary\u003e\u003cp\u003eYes, each configuration is a separate case line and the minimum order applies to the order rather than the line.\u003c\/p\u003e\u003c\/details\u003e\n\u003ch2\u003eChoosing the right option\u003c\/h2\u003e\u003cp\u003eRelated products in the same laboratory line:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/products\/specimen-container-120ml-sterile-screw-cap-100-pack\"\u003especimen container 120ml sterile screw cap 100 pack\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/products\/stool-collection-kit-sterile-100-pack\"\u003estool collection kit sterile 100 pack\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eBackground reading before you order:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/transfer-pipettes-vs-serological-pipettes\"\u003etransfer pipettes vs serological pipettes\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/fr\/products\/specimen-container-120ml-sterile-screw-cap-100-pack\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/P4114-w-measurements.jpg?v=1795451449\" alt=\"Laboratory consumables\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"MTC Bio","offers":[{"title":"Transfer pipette · 7mL · large bulb · graduated to 3mL · non-sterile · bulk","offer_id":49487110111454,"sku":"CLI-TPIP-7-P4114-00","price":408.11,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 7mL · large bulb · graduated to 3mL · sterile · individu","offer_id":49487795585246,"sku":"CLI-TPIP-7-P4114-11","price":89.8,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 7mL · large bulb · graduated to 3mL · sterile · peel pac","offer_id":49487795618014,"sku":"CLI-TPIP-7-P4114-14","price":381.93,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 7mL · large bulb · extended tip · non-sterile · bulk pac","offer_id":49487795650782,"sku":"CLI-TPIP-7-P4123-01","price":734.71,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 7mL · large bulb · extended tip · sterile · individually","offer_id":49487795683550,"sku":"CLI-TPIP-7-P4123-11","price":128.97,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/P4114-w-measurements.jpg?v=1795451449"},{"product_id":"mtc-bio-1-5-ml-transfer-pipettes-small-bulb-extended-tip-sterile-or-bulk","title":"MTC Bio 1.5 mL Transfer Pipettes, Small Bulb, Extended Tip, Sterile or Bulk","description":"\u003cp\u003e\u003cstrong\u003eMTC Bio 1.5 mL transfer pipettes with a small bulb and extended tip,\u003c\/strong\u003e 500 per pack and up to 3,000 per case, shipped from North American stock.\u003c\/p\u003e\n\u003cp\u003eSmall bulb, extended tip, short body: this is the pipette for a microtube, a cryogenic vial or a narrow-neck container where a 5 mL pipette would not fit and a pipettor would be slower than the task deserves. The extended tip reaches the bottom of the vessel, and the small bulb gives enough draw for 1 to 1.5 mL without flooding the tip.\u003c\/p\u003e\n\u003ch2\u003eWhat is in a case of 1.5 mL transfer pipettes?\u003c\/h2\u003e\n\u003cp\u003eThe non-sterile bulk configuration holds 500 pipettes per pack and six packs per case, so 3,000 pipettes. The sterile individually wrapped configuration holds 500 pipettes per case.\u003c\/p\u003e\n\u003cp\u003eBecause both configurations are 500 per pack, the choice between them is the sterile claim rather than pack size.\u003c\/p\u003e\n\u003cp\u003eA pack of 500 is small enough to keep at the bench without a second storage decision, which is why this size is usually bought as a pack rather than a case; the case is the reorder unit for a bench that has settled on the format.\u003c\/p\u003e\n\u003cp\u003eBoth configurations are packed in a plain poly bag with the manufacturer reference printed on it, so a pack can be identified after the carton is broken down.\u003c\/p\u003e\n\u003ch2\u003eWhen is a 1.5 mL pipette the right tool?\u003c\/h2\u003e\n\u003cp\u003eWhen the vessel is small: microtubes, cryogenic vials, narrow-neck bottles, and wells that a 5 mL pipette cannot enter without touching the sides. When the volume is 1 to 1.5 mL and the task is transfer rather than measurement. When an aerosol or a droplet must be avoided by keeping the tip below the liquid surface.\u003c\/p\u003e\n\u003cp\u003eWhen the volume is larger than 1.5 mL, step up to the 5 mL or 7 mL size instead of drawing twice: a second draw from the same pipette is where cross-contamination usually starts.\u003c\/p\u003e\n\u003cp\u003eIt is also the size to reach for when the source vessel is a cryogenic vial being sampled without thawing the whole box: the extended tip reaches the liquid at the bottom of a 2 mL vial while the body stays above the rim, so the vial can be reclosed without touching the tip.\u003c\/p\u003e\n\u003ch2\u003eWhat are the specifications of the 1.5 mL transfer pipette?\u003c\/h2\u003e\n\u003cp\u003eEvery configuration below is a separate case line. The manufacturer reference is what appears on the quotation, the packing slip and the lot documentation, so quote it when you ask for a certificate of analysis.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eManufacturer reference\u003c\/th\u003e\n\u003cth\u003ePack\u003c\/th\u003e\n\u003cth\u003eCase\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 1.5mL · small bulb · extended tip · non-sterile · b\u003c\/td\u003e\n\u003ctd\u003eP4121-01\u003c\/td\u003e\n\u003ctd\u003e500 per pack\u003c\/td\u003e\n\u003ctd\u003e3,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 1.5mL · small bulb · extended tip · sterile · indiv\u003c\/td\u003e\n\u003ctd\u003eP4121-11\u003c\/td\u003e\n\u003ctd\u003e500 per pack\u003c\/td\u003e\n\u003ctd\u003e500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHow many small-bulb pipettes does a lab use?\u003c\/h2\u003e\n\u003cp\u003eA micro bench doing 60 microtube transfers a day uses 60 pipettes, about 1,250 a month; a 3,000-pipette bulk case lasts two to three months. A sterile user doing 12 transfers a day uses about 250 a month, so a 500-count sterile case lasts two months.\u003c\/p\u003e\n\u003cp\u003eSmall-bulb pipettes are the item most often borrowed across benches, so keep the working pack at the bench and the case in storage rather than the other way round.\u003c\/p\u003e\n\u003cp\u003eA bench that transfers into cryogenic vials and microtubes in the same session should count the vials, not the samples: each vial draw is one pipette, and a 96-vial box is 96 pipettes before any tube work starts.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eWorking pattern\u003c\/th\u003e\n\u003cth\u003eUsed per month\u003c\/th\u003e\n\u003cth\u003eCase covers\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne bench, light use\u003c\/td\u003e\n\u003ctd\u003eabout 300 pieces\u003c\/td\u003e\n\u003ctd\u003eroughly 8 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne bench, full shift\u003c\/td\u003e\n\u003ctd\u003eabout 2,000 pieces\u003c\/td\u003e\n\u003ctd\u003eroughly 2 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwo benches\u003c\/td\u003e\n\u003ctd\u003eabout 4,000 pieces\u003c\/td\u003e\n\u003ctd\u003eunder one month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCounts above are planning figures from pack and case sizes on this page, not a forecast of your own consumption; check them against a week of your own bench records before setting a reorder point.\u003c\/p\u003e\n\u003ch2\u003eHow is it shipped, and what does the lot tell you?\u003c\/h2\u003e\n\u003cp\u003ePipettes ship from North American stock, 1 to 2 business days in Ontario, 2 to 4 across Canada, 2 to 3 to US addresses. The sterile configuration carries the manufacturer reference and lot on the wrapper, and sterilisation documentation is available against that reference. Ask for the sterilisation record with the lot number if your quality file needs it, and keep the case label with the case until the last pack is used.\u003c\/p\u003e\n\u003cp\u003eStore the case closed and dry; polyethylene will take a set if it is stored under weight or in heat, and a deformed tip will not enter a narrow vessel.\u003c\/p\u003e\n\u003cp\u003eIndividually wrapped pipettes are the format that lets a quality file name a wrapper rather than a bag, so if the audit trail asks for one pipette per record, order that configuration and not the peel pack.\u003c\/p\u003e\n\u003ch2\u003eWhat we do not claim\u003c\/h2\u003e\n\u003cp\u003eSingle-use laboratory consumables for liquid transfer. Not sold as medical devices for patient treatment. Sterility and tip geometry are the manufacturer's stated values; the pipette is not a calibrated measuring instrument.\u003c\/p\u003e\n\u003cp\u003eWhat we cannot do is tell you whether an extended tip will clear your specific vial neck: send the vessel and we will check the tip dimension against the manufacturer drawing.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eHow many pipettes per case?\u003c\/summary\u003e\u003cp\u003eThe non-sterile bulk configuration ships 3,000 per case in six packs of 500; the sterile individually wrapped configuration ships 500 per case.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat is the bulb size for?\u003c\/summary\u003e\u003cp\u003eA small bulb gives a controlled draw for 1 to 1.5 mL, which keeps the tip from overflowing when transferring into a narrow vessel.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWill it fit a 1.5 mL microtube?\u003c\/summary\u003e\u003cp\u003eThe extended tip is designed for narrow vessels and reaches the bottom of a 1.5 mL tube; the small bulb keeps the body clear of the rim.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eAre the sterile pipettes wrapped one by one?\u003c\/summary\u003e\u003cp\u003eYes, the sterile configuration is individually wrapped, 500 per case.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan the pipette be re-sterilised?\u003c\/summary\u003e\u003cp\u003eNo. The sterile claim belongs to the manufacturer's process and the sealed wrapper; once opened, the pipette is a single-use non-sterile item.\u003c\/p\u003e\u003c\/details\u003e\n\u003ch2\u003eChoosing the right option\u003c\/h2\u003e\u003cp\u003eRelated products in the same laboratory line:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/products\/mtc-bio-sureseal-s-1-5ml-sterile-microcentrifuge-tubes-500-pack\"\u003emtc bio sureseal s 1 5ml sterile microcentrifuge tubes 500 pack\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/products\/stool-collection-kit-sterile-100-pack\"\u003estool collection kit sterile 100 pack\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eBackground reading before you order:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/transfer-pipettes-vs-serological-pipettes\"\u003etransfer pipettes vs serological pipettes\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/fr\/products\/mtc-bio-sureseal-s-1-5ml-sterile-microcentrifuge-tubes-500-pack\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/P4121-w-measurements.jpg?v=1795451478\" alt=\"Laboratory consumables\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"MTC Bio","offers":[{"title":"Transfer pipette · 1.5mL · small bulb · extended tip · non-sterile · bulk p","offer_id":49487110635742,"sku":"CLI-TPIP-1.5-P4121-01","price":440.83,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 1.5mL · small bulb · extended tip · sterile · individual","offer_id":49487794733278,"sku":"CLI-TPIP-1.5-P4121-11","price":112.66,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/P4121-w-measurements.jpg?v=1795451478"},{"product_id":"mtc-bio-5-ml-transfer-pipettes-large-bulb-sterile-or-bulk-graduated-options","title":"MTC Bio 5 mL Transfer Pipettes, Large Bulb, Sterile or Bulk, Graduated Options","description":"\u003cp\u003e\u003cstrong\u003eMTC Bio 5 mL transfer pipettes with a large bulb,\u003c\/strong\u003e in non-sterile bulk packs of 250 and sterile formats up to 5,000 per case, shipped from North American stock.\u003c\/p\u003e\n\u003cp\u003eA transfer pipette is the tool a bench reaches for when a pipettor is overkill: moving a few millilitres between a tube and a tube, adding a reagent to a strip, taking a sample out of a specimen container. This range keeps the same 5 mL large bulb and changes only what a protocol actually cares about: sterile or non-sterile, graduated to 1 mL or unmarked, standard tip or extended tip for narrow vessels, and bulk pack or individual wrap. Polyethylene body, one piece, no separate bulb to lose.\u003c\/p\u003e\n\u003ch2\u003eWhat is in a case of 5 mL transfer pipettes?\u003c\/h2\u003e\n\u003cp\u003eBulk non-sterile configurations hold 250 pipettes per pack and 20 packs per case, so 5,000 pipettes. Sterile peel-pack configurations hold 500 per case in packs of 20, and individually wrapped sterile configurations hold 500 per case.\u003c\/p\u003e\n\u003cp\u003eBulk packs are for a bench that goes through pipettes quickly and does not need a sterile claim; the sterile formats are for cell work, microbiology and any step where the pipette enters a sterile vessel.\u003c\/p\u003e\n\u003ch2\u003eWhich format should you order: bulk, peel pack or individually wrapped?\u003c\/h2\u003e\n\u003cp\u003eBulk is the working stock for non-sterile steps: staining, reagent transfer, waste removal. Peel packs of 20 keep the rest of the pack covered while one pipette is in use, which is the usual choice for a sterile bench that uses several pipettes per session. Individually wrapped is for a controlled step where each pipette must be traceable to an unopened wrapper, and it is the format most often asked for in audit-facing SOPs.\u003c\/p\u003e\n\u003cp\u003eGraduation is a separate decision: graduated to 1 mL lets a technician estimate volume directly in the pipette, while unmarked pipettes push the measurement back to a graduated tube. Extended tips reach the bottom of a narrow 15 mL tube without the bulb touching the rim.\u003c\/p\u003e\n\u003ch2\u003eWhat are the specifications?\u003c\/h2\u003e\n\u003cp\u003eEvery configuration below is a separate case line. The manufacturer reference is what appears on the quotation, the packing slip and the lot documentation, so quote it when you ask for a certificate of analysis.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eManufacturer reference\u003c\/th\u003e\n\u003cth\u003ePack\u003c\/th\u003e\n\u003cth\u003eCase\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 5mL · large bulb · non-sterile · bulk pack · 250\/pk\u003c\/td\u003e\n\u003ctd\u003eP4111-00\u003c\/td\u003e\n\u003ctd\u003e250 per pack\u003c\/td\u003e\n\u003ctd\u003e5,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 5mL · large bulb · sterile · individually wrapped ·\u003c\/td\u003e\n\u003ctd\u003eP4111-11\u003c\/td\u003e\n\u003ctd\u003e500 per pack\u003c\/td\u003e\n\u003ctd\u003e500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 5mL · large bulb · sterile · peel packs of 20 · 500\u003c\/td\u003e\n\u003ctd\u003eP4111-14\u003c\/td\u003e\n\u003ctd\u003e500 per pack\u003c\/td\u003e\n\u003ctd\u003e1,500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 5mL · large bulb · graduated to 1mL · non-sterile ·\u003c\/td\u003e\n\u003ctd\u003eP4113-00\u003c\/td\u003e\n\u003ctd\u003e250 per pack\u003c\/td\u003e\n\u003ctd\u003e5,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 5mL · large bulb · graduated to 1mL · sterile · ind\u003c\/td\u003e\n\u003ctd\u003eP4113-11\u003c\/td\u003e\n\u003ctd\u003e500 per pack\u003c\/td\u003e\n\u003ctd\u003e500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 5mL · extended tip · non-sterile · bulk pack · 500\/\u003c\/td\u003e\n\u003ctd\u003eP4122-01\u003c\/td\u003e\n\u003ctd\u003e500 per pack\u003c\/td\u003e\n\u003ctd\u003e3,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 5mL · extended tip · sterile · individually wrapped\u003c\/td\u003e\n\u003ctd\u003eP4122-11\u003c\/td\u003e\n\u003ctd\u003e500 per pack\u003c\/td\u003e\n\u003ctd\u003e500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHow many transfer pipettes does a bench use in a month?\u003c\/h2\u003e\n\u003cp\u003eA bench performing 30 specimen preparations a day with one pipette per preparation uses 30 a day, about 650 a month, so a 5,000-pipette bulk case lasts seven to eight months. A sterile peel-pack user doing 20 sterile transfers a day uses 400 a month and a 500-count case lasts about five weeks.\u003c\/p\u003e\n\u003cp\u003eBecause a bulk case is large, split storage matters: keep one open pack on the bench and the rest of the case closed and dry, and rotate stock so the oldest pack is used first.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eWorking pattern\u003c\/th\u003e\n\u003cth\u003eUsed per month\u003c\/th\u003e\n\u003cth\u003eCase covers\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne bench, light use\u003c\/td\u003e\n\u003ctd\u003eabout 300 pieces\u003c\/td\u003e\n\u003ctd\u003eroughly 8 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne bench, full shift\u003c\/td\u003e\n\u003ctd\u003eabout 2,000 pieces\u003c\/td\u003e\n\u003ctd\u003eroughly 2 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwo benches\u003c\/td\u003e\n\u003ctd\u003eabout 4,000 pieces\u003c\/td\u003e\n\u003ctd\u003eunder one month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCounts above are planning figures from pack and case sizes on this page, not a forecast of your own consumption; check them against a week of your own bench records before setting a reorder point.\u003c\/p\u003e\n\u003ch2\u003eHow is it shipped, and what documentation comes with it?\u003c\/h2\u003e\n\u003cp\u003ePipettes ship from North American stock: 1 to 2 business days within Ontario, 2 to 4 across Canada and 2 to 3 to US addresses. Sterile formats carry the manufacturer reference and lot on the pack; the sterilisation documentation is available on request against that reference.\u003c\/p\u003e\n\u003cp\u003eStore the case closed and away from heat; polyethylene softens in a hot vehicle and a deformed bulb will not draw the stated volume. Do not re-sterilise a pipette.\u003c\/p\u003e\n\u003ch2\u003eWhat we do not claim\u003c\/h2\u003e\n\u003cp\u003eSingle-use laboratory consumables for liquid transfer. Not sold as medical devices for patient treatment. Sterility, graduation and tip shape are the manufacturer's stated values; where a configuration is not marked sterile, treat it as non-sterile.\u003c\/p\u003e\n\u003cp\u003eWhat we cannot do is choose between graduated and unmarked for your SOP: send the step that measures volume and we will tell you which format keeps the measurement in one place.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eHow many pipettes are in a bulk case?\u003c\/summary\u003e\u003cp\u003e250 pipettes per pack and 20 packs per case, so 5,000 non-sterile bulk pipettes; sterile formats ship 500 per case.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs the 5 mL graduation accurate enough for a protocol?\u003c\/summary\u003e\u003cp\u003eThe graduation is a moulded mark for estimating volume, not a calibrated measurement; where a protocol needs a measured volume, use a graduated cylinder or a pipettor.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat does extended tip mean?\u003c\/summary\u003e\u003cp\u003eThe tip is longer and narrower than the standard tip, so it reaches the bottom of a narrow tube without the bulb touching the rim.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eAre the sterile pipettes individually wrapped?\u003c\/summary\u003e\u003cp\u003eBoth formats exist: peel packs of 20 for bench use and individual wraps where each pipette must come from an unopened wrapper.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan transfer pipettes be used with acids or solvents?\u003c\/summary\u003e\u003cp\u003eThe body is polyethylene, which suits aqueous solutions and many alcohols; check chemical compatibility before use with strong solvents, and ask us if you need the manufacturer's compatibility list.\u003c\/p\u003e\u003c\/details\u003e\n\u003ch2\u003eChoosing the right option\u003c\/h2\u003e\u003cp\u003eRelated products in the same laboratory line:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/products\/specimen-container-120ml-sterile-screw-cap-100-pack\"\u003especimen container 120ml sterile screw cap 100 pack\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/products\/stool-collection-kit-sterile-100-pack\"\u003estool collection kit sterile 100 pack\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eBackground reading before you order:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/transfer-pipettes-vs-serological-pipettes\"\u003etransfer pipettes vs serological pipettes\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/fr\/products\/specimen-container-120ml-sterile-screw-cap-100-pack\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/P4111-w-measurements.jpg?v=1795451544\" alt=\"Laboratory consumables\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"MTC Bio","offers":[{"title":"Transfer pipette · 5mL · large bulb · non-sterile · bulk pack · 250\/pk","offer_id":49487111717086,"sku":"CLI-TPIP-5-P4111-00","price":408.11,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 5mL · large bulb · sterile · individually wrapped · 500\/","offer_id":49487795257566,"sku":"CLI-TPIP-5-P4111-11","price":89.8,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 5mL · large bulb · sterile · peel packs of 20 · 500\/cs","offer_id":49487795290334,"sku":"CLI-TPIP-5-P4111-14","price":190.96,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 5mL · large bulb · graduated to 1mL · non-sterile · bulk","offer_id":49487795323102,"sku":"CLI-TPIP-5-P4113-00","price":408.11,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 5mL · large bulb · graduated to 1mL · sterile · individu","offer_id":49487795355870,"sku":"CLI-TPIP-5-P4113-11","price":89.8,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 5mL · extended tip · non-sterile · bulk pack · 500\/pk","offer_id":49487795388638,"sku":"CLI-TPIP-5-P4122-01","price":440.83,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 5mL · extended tip · sterile · individually wrapped · 50","offer_id":49487795421406,"sku":"CLI-TPIP-5-P4122-11","price":112.66,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/P4111-w-measurements.jpg?v=1795451544"},{"product_id":"mtc-bio-4-ml-transfer-pipettes-short-stem-or-standard-sterile-or-bulk-packs","title":"MTC Bio 4 mL Transfer Pipettes, Short Stem or Standard, Sterile or Bulk Packs","description":"\u003cp\u003e\u003cstrong\u003eMTC Bio 4 mL transfer pipettes in short-stem and standard formats,\u003c\/strong\u003e non-sterile bulk packs of 250 to 500 and sterile packs up to 5,000 per case, shipped from North American stock.\u003c\/p\u003e\n\u003cp\u003eFour millilitres sits between the small-bulb pipette used on a microtube and the 5 mL pipette used on a specimen container. The short-stem version fits a shallow vessel and a tight rack position; the standard version reaches into a deeper tube. Sterile packs cover cell work, bulk packs cover staining and reagent handling.\u003c\/p\u003e\n\u003ch2\u003eWhat is in a case of 4 mL transfer pipettes?\u003c\/h2\u003e\n\u003cp\u003eShort-stem bulk holds 250 pipettes per pack and 20 packs per case, so 5,000. Standard bulk holds 500 per pack and six packs per case, so 3,000. Sterile individually wrapped holds 500 per case, and sterile peel packs of 20 also ship 500 per case.\u003c\/p\u003e\n\u003cp\u003eBulk is the working stock; sterile formats are the audit-facing stock, so the case count difference between 3,000 and 500 is the difference between a bench supply and a controlled-use supply.\u003c\/p\u003e\n\u003cp\u003eBulk packs are bagged rather than boxed, so a pack can sit on the bench in a beaker without the carton taking water; the sterile formats come in a sealed bag that carries the lot on the outside, which is the label a quality file needs.\u003c\/p\u003e\n\u003ch2\u003eShort stem or standard stem?\u003c\/h2\u003e\n\u003cp\u003eA short stem is for shallow vessels, small racks and tight positions where a long pipette would tip the container or touch the bench. The standard stem reaches the bottom of a 15 mL tube or a deep container, and it is the format a dispensary uses for decanting from a bottle.\u003c\/p\u003e\n\u003cp\u003eBecause both are 4 mL, the choice is reach rather than volume: a short stem in a deep tube leaves liquid behind, and a long stem in a shallow vessel is harder to control.\u003c\/p\u003e\n\u003cp\u003eA short-stem pipette also reduces the chance of the bulb touching the inside of a specimen container, which is the usual route for a cross-contamination that nobody notices until a control fails.\u003c\/p\u003e\n\u003cp\u003eBoth stem lengths draw the same 4 mL; the difference is where the tip can go, so a lab that works from deep tubes and shallow dishes should keep one pack of each rather than standardising on one.\u003c\/p\u003e\n\u003ch2\u003eWhat are the specifications of the 4 mL transfer pipette?\u003c\/h2\u003e\n\u003cp\u003eEvery configuration below is a separate case line. The manufacturer reference is what appears on the quotation, the packing slip and the lot documentation, so quote it when you ask for a certificate of analysis.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eManufacturer reference\u003c\/th\u003e\n\u003cth\u003ePack\u003c\/th\u003e\n\u003cth\u003eCase\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 4mL · short stem · non-sterile · bulk pack · 250\/pk\u003c\/td\u003e\n\u003ctd\u003eP4132-00\u003c\/td\u003e\n\u003ctd\u003e250 per pack\u003c\/td\u003e\n\u003ctd\u003e5,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 4mL · short stem · sterile · individually wrapped ·\u003c\/td\u003e\n\u003ctd\u003eP4132-11\u003c\/td\u003e\n\u003ctd\u003e500 per pack\u003c\/td\u003e\n\u003ctd\u003e500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 4mL · non-sterile · bulk pack · 500\/pk\u003c\/td\u003e\n\u003ctd\u003eP4133-00\u003c\/td\u003e\n\u003ctd\u003e500 per pack\u003c\/td\u003e\n\u003ctd\u003e3,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 4mL · sterile · individually wrapped · 500\/cs\u003c\/td\u003e\n\u003ctd\u003eP4133-11\u003c\/td\u003e\n\u003ctd\u003e500 per pack\u003c\/td\u003e\n\u003ctd\u003e500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 4mL · sterile · peel packs of 20 · 500\/cs\u003c\/td\u003e\n\u003ctd\u003eP4133-14\u003c\/td\u003e\n\u003ctd\u003e500 per pack\u003c\/td\u003e\n\u003ctd\u003e1,500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHow many 4 mL pipettes does a bench use?\u003c\/h2\u003e\n\u003cp\u003eA bench doing 25 transfers a day uses 25 pipettes, about 540 a month, so a 3,000-pipette bulk case lasts five to six months. A sterile user doing 15 transfers a day uses 320 a month and a 500-count sterile case lasts six weeks.\u003c\/p\u003e\n\u003cp\u003eKeep the sterile pack closed between sessions and the bulk case closed in storage; a polyethylene pipette left in sunlight takes a set and will not draw the same volume.\u003c\/p\u003e\n\u003cp\u003eCount pipettes by vessel, not by sample: a sample that is split across three tubes is three pipettes if the protocol changes pipette between tubes, and one if it does not. Writing that decision into the SOP is what makes the reorder point real.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eWorking pattern\u003c\/th\u003e\n\u003cth\u003eUsed per month\u003c\/th\u003e\n\u003cth\u003eCase covers\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne bench, light use\u003c\/td\u003e\n\u003ctd\u003eabout 300 pieces\u003c\/td\u003e\n\u003ctd\u003eroughly 8 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne bench, full shift\u003c\/td\u003e\n\u003ctd\u003eabout 2,000 pieces\u003c\/td\u003e\n\u003ctd\u003eroughly 2 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwo benches\u003c\/td\u003e\n\u003ctd\u003eabout 4,000 pieces\u003c\/td\u003e\n\u003ctd\u003eunder one month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCounts above are planning figures from pack and case sizes on this page, not a forecast of your own consumption; check them against a week of your own bench records before setting a reorder point.\u003c\/p\u003e\n\u003ch2\u003eHow is it shipped, and what documentation comes with it?\u003c\/h2\u003e\n\u003cp\u003ePipettes ship from North American stock: 1 to 2 business days in Ontario, 2 to 4 across Canada, 2 to 3 to US addresses. Sterile packs carry the manufacturer reference and lot.\u003c\/p\u003e\n\u003cp\u003eIf a quality file needs the sterilisation record, ask for it against the lot on the pack before the pack is opened.\u003c\/p\u003e\n\u003cp\u003eIf the pipettes are stored in a drawer rather than a carton, keep them in the original bag: a loose pipette in a drawer picks up dust and the bulb collects it.\u003c\/p\u003e\n\u003ch2\u003eWhat we do not claim\u003c\/h2\u003e\n\u003cp\u003eSingle-use laboratory consumables for liquid transfer. Not sold as medical devices for patient treatment. Sterility and stem length are the manufacturer's stated values; the pipette is not a calibrated measuring instrument.\u003c\/p\u003e\n\u003cp\u003eWhat we cannot do is tell you which stem length clears your vessel: send the container depth and we will check the pipette dimension against the manufacturer drawing.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eHow many pipettes per bulk case?\u003c\/summary\u003e\u003cp\u003eShort-stem bulk ships 5,000 per case in 20 packs of 250; standard bulk ships 3,000 per case in six packs of 500.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs the sterile version individually wrapped?\u003c\/summary\u003e\u003cp\u003eBoth sterile formats exist: individually wrapped 500 per case and peel packs of 20, also 500 per case.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat is the short stem for?\u003c\/summary\u003e\u003cp\u003eShallow vessels and tight rack positions, where a long pipette would tip the container or touch the bench.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan it be used for cell work?\u003c\/summary\u003e\u003cp\u003eThe sterile configuration is intended for sterile work; the bulk non-sterile configuration should not enter a sterile vessel.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I mix stem lengths in one order?\u003c\/summary\u003e\u003cp\u003eYes, each configuration is a separate case line and the minimum order applies to the order.\u003c\/p\u003e\u003c\/details\u003e\n\u003ch2\u003eChoosing the right option\u003c\/h2\u003e\u003cp\u003eRelated products in the same laboratory line:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/products\/sterile-centrifuge-tubes-15ml-500-case\"\u003esterile centrifuge tubes 15ml 500 case\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/products\/mtc-bio-sureseal-s-1-5ml-sterile-microcentrifuge-tubes-500-pack\"\u003emtc bio sureseal s 1 5ml sterile microcentrifuge tubes 500 pack\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eBackground reading before you order:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/transfer-pipettes-vs-serological-pipettes\"\u003etransfer pipettes vs serological pipettes\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/fr\/products\/sterile-centrifuge-tubes-15ml-500-case\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/P4132-w-measurements.jpg?v=1795452290\" alt=\"Laboratory consumables\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"MTC Bio","offers":[{"title":"Transfer pipette · 4mL · short stem · non-sterile · bulk pack · 250\/pk","offer_id":49487120597214,"sku":"CLI-TPIP-4-P4132-00","price":537.83,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 4mL · short stem · sterile · individually wrapped · 500\/","offer_id":49487795060958,"sku":"CLI-TPIP-4-P4132-11","price":89.8,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 4mL · non-sterile · bulk pack · 500\/pk","offer_id":49487795093726,"sku":"CLI-TPIP-4-P4133-00","price":323.25,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 4mL · sterile · individually wrapped · 500\/cs","offer_id":49487795126494,"sku":"CLI-TPIP-4-P4133-11","price":80.8,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 4mL · sterile · peel packs of 20 · 500\/cs","offer_id":49487795159262,"sku":"CLI-TPIP-4-P4133-14","price":190.96,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/P4132-w-measurements.jpg?v=1795452290"},{"product_id":"mtc-bio-exact-volume-transfer-pipettes-20-to-500-microlitre-sterile-bags","title":"MTC Bio Exact Volume Transfer Pipettes, 20 to 500 microlitre, Sterile Bags","description":"\u003cp\u003e\u003cstrong\u003eSterile exact volume transfer pipettes from 20 to 500 microlitre,\u003c\/strong\u003e ten fixed volumes with matched stem lengths, in resealable bags of 1,000 to 5,000, shipped from North American stock.\u003c\/p\u003e\n\u003cp\u003eAn exact volume transfer pipette has a bulb moulded to one volume, so the draw stops at that volume and the operator does not have to watch a graduation. This range runs from 20 microlitre at 53 mm to 500 microlitre at 120 mm, with the stem length matched to the volume, so a lab can hold one tool per volume instead of one pipette with a printed scale. All configurations are sterile and bagged in resealable bags.\u003c\/p\u003e\n\u003ch2\u003eWhat is in a bag of exact volume pipettes?\u003c\/h2\u003e\n\u003cp\u003eThe 20 microlitre configuration holds 5,000 pipettes in 10 resealable bags, so 500 per bag across a 10-bag case. The 50, 80, 100, 150, 200 and 250 microlitre configurations hold 2,500 in five bags, and the 300, 400 and 500 microlitre configurations hold 1,000 in two bags.\u003c\/p\u003e\n\u003cp\u003eVolume decides the bag count because the bulb grows with the volume: a 500 microlitre bulb takes roughly ten times the shelf space of a 20 microlitre one, so the case is smaller for the larger volumes.\u003c\/p\u003e\n\u003ch2\u003eHow do you pick the volume, and when is exact volume worth it?\u003c\/h2\u003e\n\u003cp\u003eExact volume earns its price where a step depends on a repeatable small volume and a pipettor is either unavailable or slower than the task: adding a fixed reagent to a strip, inoculating a fixed volume into broth, transferring a stain. The 20 to 100 microlitre range covers most of those steps, and the 150 to 500 microlitre range covers bulk reagent additions.\u003c\/p\u003e\n\u003cp\u003eStem length tracks volume: 53 mm for 20 microlitre, 72 mm for 50, 96 to 100 mm through 80 to 200, and 113 to 120 mm for 250 to 500. A short stem on a large volume gives the bulb a shorter drop, which is what keeps a 500 microlitre transfer controllable.\u003c\/p\u003e\n\u003ch2\u003eWhat are the specifications?\u003c\/h2\u003e\n\u003cp\u003eEvery configuration below is a separate case line. The manufacturer reference is what appears on the quotation, the packing slip and the lot documentation, so quote it when you ask for a certificate of analysis.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eManufacturer reference\u003c\/th\u003e\n\u003cth\u003ePack\u003c\/th\u003e\n\u003cth\u003eCase\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Volume Transfer Pipette · 20uL · 53mm · sterile · 10 resealable \u003c\/td\u003e\n\u003ctd\u003eE9500-20\u003c\/td\u003e\n\u003ctd\u003e5,000 per pack\u003c\/td\u003e\n\u003ctd\u003e50,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Volume Transfer Pipette · 50uL · 72mm · sterile · 5 resealable b\u003c\/td\u003e\n\u003ctd\u003eE9500-50\u003c\/td\u003e\n\u003ctd\u003e2,500 per pack\u003c\/td\u003e\n\u003ctd\u003e12,500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Volume Transfer Pipette · 80uL · 96mm · sterile · 5 resealable b\u003c\/td\u003e\n\u003ctd\u003eE9500-80\u003c\/td\u003e\n\u003ctd\u003e2,500 per pack\u003c\/td\u003e\n\u003ctd\u003e12,500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Volume Transfer Pipette · 100uL · 86mm · sterile · 5 resealable \u003c\/td\u003e\n\u003ctd\u003eE9500-100\u003c\/td\u003e\n\u003ctd\u003e2,500 per pack\u003c\/td\u003e\n\u003ctd\u003e12,500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Volume Transfer Pipette · 150uL · 100mm · sterile · 5 resealable\u003c\/td\u003e\n\u003ctd\u003eE9500-150\u003c\/td\u003e\n\u003ctd\u003e2,500 per pack\u003c\/td\u003e\n\u003ctd\u003e12,500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Volume Transfer Pipette · 200uL · 100mm · sterile · 5 resealable\u003c\/td\u003e\n\u003ctd\u003eE9500-200\u003c\/td\u003e\n\u003ctd\u003e2,500 per pack\u003c\/td\u003e\n\u003ctd\u003e12,500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Volume Transfer Pipette · 250uL · 113mm · sterile · 5 resealable\u003c\/td\u003e\n\u003ctd\u003eE9500-250\u003c\/td\u003e\n\u003ctd\u003e2,500 per pack\u003c\/td\u003e\n\u003ctd\u003e12,500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Volume Transfer Pipette · 300uL · 113mm · sterile · 2 resealable\u003c\/td\u003e\n\u003ctd\u003eE9500-300\u003c\/td\u003e\n\u003ctd\u003e1,000 per pack\u003c\/td\u003e\n\u003ctd\u003e2,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Volume Transfer Pipette · 400uL · 115mm · sterile · 2 resealable\u003c\/td\u003e\n\u003ctd\u003eE9500-400\u003c\/td\u003e\n\u003ctd\u003e1,000 per pack\u003c\/td\u003e\n\u003ctd\u003e2,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Volume Transfer Pipette · 500uL · 120mm · sterile · 2 resealable\u003c\/td\u003e\n\u003ctd\u003eE9500-500\u003c\/td\u003e\n\u003ctd\u003e1,000 per pack\u003c\/td\u003e\n\u003ctd\u003e2,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHow many exact volume pipettes does a bench use?\u003c\/h2\u003e\n\u003cp\u003eA bench doing 40 fixed additions a day uses 40 pipettes, about 850 a month, so a 2,500-pipette case of one volume lasts three months. Where a protocol uses three volumes, the consumption splits across three cases, and the reorder point should be set per volume rather than for pipettes as a class.\u003c\/p\u003e\n\u003cp\u003eBecause these are single-volume tools, a bench that changes protocol often ends up with several part-used cases; label each bag with the volume on the outside so a bag is not opened twice for the same step.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eWorking pattern\u003c\/th\u003e\n\u003cth\u003eUsed per month\u003c\/th\u003e\n\u003cth\u003eCase covers\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne bench, light use\u003c\/td\u003e\n\u003ctd\u003eabout 300 pieces\u003c\/td\u003e\n\u003ctd\u003eroughly 8 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne bench, full shift\u003c\/td\u003e\n\u003ctd\u003eabout 2,000 pieces\u003c\/td\u003e\n\u003ctd\u003eroughly 2 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwo benches\u003c\/td\u003e\n\u003ctd\u003eabout 4,000 pieces\u003c\/td\u003e\n\u003ctd\u003eunder one month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCounts above are planning figures from pack and case sizes on this page, not a forecast of your own consumption; check them against a week of your own bench records before setting a reorder point.\u003c\/p\u003e\n\u003ch2\u003eHow is it shipped, and how should it be stored?\u003c\/h2\u003e\n\u003cp\u003ePipettes ship from North American stock, 1 to 2 business days in Ontario, 2 to 4 across Canada, 2 to 3 to US addresses. Each resealable bag carries the manufacturer reference and lot.\u003c\/p\u003e\n\u003cp\u003eReseal the bag after each use and store flat: a bulb that has been compressed under a carton will not return to its moulded volume, and a pipette that is off volume is worse than no pipette at all.\u003c\/p\u003e\n\u003ch2\u003eWhat we do not claim\u003c\/h2\u003e\n\u003cp\u003eSingle-use laboratory consumables for liquid transfer. Not sold as medical devices for patient treatment. The volume is a nominal moulded value rather than a calibration; sterility is the manufacturer's stated value per configuration.\u003c\/p\u003e\n\u003cp\u003eWhat we cannot do is certify the delivered drop of a moulded bulb: if a step needs a tolerance tighter than the moulded volume, send us the tolerance and we will say whether this range fits.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eHow many pipettes per case?\u003c\/summary\u003e\u003cp\u003e20 microlitre holds 5,000 in 10 bags of 500; 50 to 250 microlitre hold 2,500 in five bags; 300 to 500 microlitre hold 1,000 in two bags.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs the volume exact?\u003c\/summary\u003e\u003cp\u003eThe bulb is moulded to the stated volume so the draw stops there; it is a nominal value rather than a calibration, and delivered volume depends on how the pipette is held.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eAre these pipettes sterile?\u003c\/summary\u003e\u003cp\u003eYes, all configurations on this page are sterile and packed in resealable bags with the lot on the bag.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhich volume should a general bench keep?\u003c\/summary\u003e\u003cp\u003e20, 100 and 200 microlitre cover most fixed additions; add 500 microlitre only if a bulk reagent step needs it.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan an exact volume pipette replace a pipettor?\u003c\/summary\u003e\u003cp\u003eFor a fixed volume, often yes; for variable volumes or for a measured transfer into a calibrated vessel, a pipettor or a graduated pipette remains the right tool.\u003c\/p\u003e\u003c\/details\u003e\n\u003ch2\u003eChoosing the right option\u003c\/h2\u003e\u003cp\u003eRelated products in the same laboratory line:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/products\/specimen-container-120ml-sterile-screw-cap-100-pack\"\u003especimen container 120ml sterile screw cap 100 pack\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/products\/mtc-bio-sureseal-s-1-5ml-sterile-microcentrifuge-tubes-500-pack\"\u003emtc bio sureseal s 1 5ml sterile microcentrifuge tubes 500 pack\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eBackground reading before you order:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/transfer-pipettes-vs-serological-pipettes\"\u003etransfer pipettes vs serological pipettes\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/fr\/products\/specimen-container-120ml-sterile-screw-cap-100-pack\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/E9500-20.jpg?v=1795452468\" alt=\"Laboratory consumables\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"MTC Bio","offers":[{"title":"Exact Volume Transfer Pipette · 20uL · 53mm · sterile · 10 resealable bags","offer_id":49487124070622,"sku":"CLI-TPIP-X-E9500-20","price":3834.65,"currency_code":"CAD","in_stock":true},{"title":"Exact Volume Transfer Pipette · 50uL · 72mm · sterile · 5 resealable bags","offer_id":49487795749086,"sku":"CLI-TPIP-X-E9500-50","price":958.64,"currency_code":"CAD","in_stock":true},{"title":"Exact Volume Transfer Pipette · 80uL · 96mm · sterile · 5 resealable bags","offer_id":49487795781854,"sku":"CLI-TPIP-X-E9500-80","price":958.64,"currency_code":"CAD","in_stock":true},{"title":"Exact Volume Transfer Pipette · 100uL · 86mm · sterile · 5 resealable bags","offer_id":49487795814622,"sku":"CLI-TPIP-X-E9500-100","price":1044.57,"currency_code":"CAD","in_stock":true},{"title":"Exact Volume Transfer Pipette · 150uL · 100mm · sterile · 5 resealable bag","offer_id":49487795847390,"sku":"CLI-TPIP-X-E9500-150","price":1044.57,"currency_code":"CAD","in_stock":true},{"title":"Exact Volume Transfer Pipette · 200uL · 100mm · sterile · 5 resealable bag","offer_id":49487795880158,"sku":"CLI-TPIP-X-E9500-200","price":1044.57,"currency_code":"CAD","in_stock":true},{"title":"Exact Volume Transfer Pipette · 250uL · 113mm · sterile · 5 resealable bag","offer_id":49487795912926,"sku":"CLI-TPIP-X-E9500-250","price":1044.57,"currency_code":"CAD","in_stock":true},{"title":"Exact Volume Transfer Pipette · 300uL · 113mm · sterile · 2 resealable bag","offer_id":49487795978462,"sku":"CLI-TPIP-X-E9500-300","price":222.16,"currency_code":"CAD","in_stock":true},{"title":"Exact Volume Transfer Pipette · 400uL · 115mm · sterile · 2 resealable bag","offer_id":49487796011230,"sku":"CLI-TPIP-X-E9500-400","price":222.16,"currency_code":"CAD","in_stock":true},{"title":"Exact Volume Transfer Pipette · 500uL · 120mm · sterile · 2 resealable bag","offer_id":49487796076766,"sku":"CLI-TPIP-X-E9500-500","price":222.16,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/E9500-20.jpg?v=1795452468"},{"product_id":"mtc-bio-4-5-ml-blood-bank-transfer-pipettes-graduated-to-2-ml","title":"MTC Bio 4.5 mL Blood Bank Transfer Pipettes, Graduated to 2 mL","description":"\u003cp\u003e\u003cstrong\u003eMTC Bio 4.5 mL blood bank transfer pipettes graduated to 2 mL,\u003c\/strong\u003e bulk packs of 250 and sterile packs of 500, shipped from North American stock.\u003c\/p\u003e\n\u003cp\u003eThe blood bank pipette is a shape rather than a volume: long enough to reach into a segment or a tube, graduated to 2 mL so a plasma or cell suspension volume can be estimated in the pipette, and sized at 4.5 mL so a full draw covers a typical serology step. This page lists the non-sterile bulk pack and the sterile individually wrapped pack of the same pipette.\u003c\/p\u003e\n\u003ch2\u003eWhat is in a case of blood bank pipettes?\u003c\/h2\u003e\n\u003cp\u003eThe non-sterile bulk configuration holds 250 pipettes per pack and 20 packs per case, so 5,000 pipettes. The sterile individually wrapped configuration holds 500 per case.\u003c\/p\u003e\n\u003cp\u003eBulk is the working stock for a serology bench that goes through pipettes steadily; the sterile wrapped pack is for a step that must come from an unopened wrapper, which is the format a transfusion service usually documents.\u003c\/p\u003e\n\u003cp\u003eThe sterile pack is wrapped individually rather than in peel packs, which matters for a transfusion service: a wrapper can be opened over a clean field without a second bag to dispose of, and each wrapper carries the lot.\u003c\/p\u003e\n\u003ch2\u003eWhen is the graduated 4.5 mL pipette the right tool?\u003c\/h2\u003e\n\u003cp\u003eWhen a volume has to be estimated inside the pipette rather than in a cylinder: adding a plasma aliquot to a tube, taking a cell suspension from a segment, or splitting a small volume between two tubes. The 2 mL graduation covers those steps, and the 4.5 mL capacity gives headroom for a full draw.\u003c\/p\u003e\n\u003cp\u003eWhere a volume has to be measured to a tolerance, this is not the tool: the graduation is moulded, and a serological pipette or a pipettor is the correct instrument. The pipette is for transfer with an estimate, not for measurement with a record.\u003c\/p\u003e\n\u003cp\u003eIn serology the pipette is often used to take an aliquot from a tube that will be returned to storage, so the tip must not touch the bench or the tube rim; a long body and a short draw make that easier than a short pipette with a large bulb.\u003c\/p\u003e\n\u003cp\u003eThe 4.5 mL body also holds enough for a two-step transfer without a second draw, which is why the format survived in blood bank work after pipettors became common.\u003c\/p\u003e\n\u003ch2\u003eWhat are the specifications of the 4.5 mL blood bank pipette?\u003c\/h2\u003e\n\u003cp\u003eEvery configuration below is a separate case line. The manufacturer reference is what appears on the quotation, the packing slip and the lot documentation, so quote it when you ask for a certificate of analysis.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eManufacturer reference\u003c\/th\u003e\n\u003cth\u003ePack\u003c\/th\u003e\n\u003cth\u003eCase\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 4.5mL · blood bank · graduated to 2mL · non-sterile\u003c\/td\u003e\n\u003ctd\u003eP4115-00\u003c\/td\u003e\n\u003ctd\u003e250 per pack\u003c\/td\u003e\n\u003ctd\u003e5,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 4.5mL · blood bank · graduated to 2mL · sterile · i\u003c\/td\u003e\n\u003ctd\u003eP4115-11\u003c\/td\u003e\n\u003ctd\u003e500 per pack\u003c\/td\u003e\n\u003ctd\u003e500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHow many pipettes does a serology bench use?\u003c\/h2\u003e\n\u003cp\u003eA bench doing 50 transfers a day uses 50 pipettes, about 1,100 a month, so a 5,000-pipette bulk case lasts four to five months. A transfusion service using sterile wrapped pipettes at 20 a day uses about 420 a month, so a 500-count case lasts five weeks.\u003c\/p\u003e\n\u003cp\u003eBecause the two configurations differ by a factor of ten in case count, a bench that switches between them mid-quarter usually ends up with a part case of each; decide which step needs sterile and stock accordingly.\u003c\/p\u003e\n\u003cp\u003eTransfusion services often run a small number of tests with a high documentation requirement, so pipette consumption tracks test count rather than sample count, and a monthly count of tests is the better reorder input.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eWorking pattern\u003c\/th\u003e\n\u003cth\u003eUsed per month\u003c\/th\u003e\n\u003cth\u003eCase covers\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne bench, light use\u003c\/td\u003e\n\u003ctd\u003eabout 300 pieces\u003c\/td\u003e\n\u003ctd\u003eroughly 8 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne bench, full shift\u003c\/td\u003e\n\u003ctd\u003eabout 2,000 pieces\u003c\/td\u003e\n\u003ctd\u003eroughly 2 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwo benches\u003c\/td\u003e\n\u003ctd\u003eabout 4,000 pieces\u003c\/td\u003e\n\u003ctd\u003eunder one month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCounts above are planning figures from pack and case sizes on this page, not a forecast of your own consumption; check them against a week of your own bench records before setting a reorder point.\u003c\/p\u003e\n\u003ch2\u003eHow is it shipped, and what documentation comes with it?\u003c\/h2\u003e\n\u003cp\u003ePipettes ship from North American stock, 1 to 2 business days in Ontario, 2 to 4 across Canada, 2 to 3 to US addresses. The sterile pack carries the manufacturer reference and lot on the wrapper.\u003c\/p\u003e\n\u003cp\u003eStore bulk packs closed and dry, and keep the sterile pack sealed until the step that needs it. A polyethylene pipette left in sunlight takes a set and will not draw the same volume.\u003c\/p\u003e\n\u003cp\u003eWhere a wrapper is retained for the record, write the lot on the worksheet at the time of use: the wrapper itself is usually discarded before the record is reviewed.\u003c\/p\u003e\n\u003cp\u003eIf a bulk pack is kept in a drawer rather than the carton, keep it in the bag: a loose pipette picks up dust and the bulb collects it.\u003c\/p\u003e\n\u003ch2\u003eWhat we do not claim\u003c\/h2\u003e\n\u003cp\u003eSingle-use laboratory consumables for liquid transfer in serology and blood bank workflows. Not sold as medical devices for patient treatment, and not a calibrated measuring instrument; the graduation is a moulded estimate.\u003c\/p\u003e\n\u003cp\u003eWhat we cannot do is confirm that a pipette meets a specific standard for a transfusion workflow: send the standard reference and we will check the manufacturer documentation rather than assume.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eHow many pipettes per case?\u003c\/summary\u003e\u003cp\u003eThe non-sterile bulk configuration is 5,000 per case in 20 packs of 250; the sterile individually wrapped configuration is 500 per case.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat is the graduation?\u003c\/summary\u003e\u003cp\u003eGraduated to 2 mL, moulded on the pipette as an estimate rather than a calibrated measurement.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs the sterile version individually wrapped?\u003c\/summary\u003e\u003cp\u003eYes, the sterile configuration is individually wrapped, 500 per case.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhy is this called a blood bank pipette?\u003c\/summary\u003e\u003cp\u003eThe shape and the 2 mL graduation suit serology and transfusion workflows, where a plasma or cell suspension volume is estimated during transfer.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan it be used for cell work?\u003c\/summary\u003e\u003cp\u003eThe sterile wrapped configuration is the one intended for sterile work; bulk non-sterile packs should stay on non-sterile steps.\u003c\/p\u003e\u003c\/details\u003e\n\u003ch2\u003eChoosing the right option\u003c\/h2\u003e\u003cp\u003eRelated products in the same laboratory line:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/products\/specimen-container-120ml-sterile-screw-cap-100-pack\"\u003especimen container 120ml sterile screw cap 100 pack\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/products\/stool-collection-kit-sterile-100-pack\"\u003estool collection kit sterile 100 pack\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eBackground reading before you order:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/transfer-pipettes-vs-serological-pipettes\"\u003etransfer pipettes vs serological pipettes\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/fr\/products\/specimen-container-120ml-sterile-screw-cap-100-pack\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/P4115-w-measurements.jpg?v=1795452674\" alt=\"Laboratory consumables\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"MTC Bio","offers":[{"title":"Transfer pipette · 4.5mL · blood bank · graduated to 2mL · non-sterile · bu","offer_id":49487126888670,"sku":"CLI-TPIP-4.5-P4115-00","price":408.11,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 4.5mL · blood bank · graduated to 2mL · sterile · indivi","offer_id":49487794995422,"sku":"CLI-TPIP-4.5-P4115-11","price":89.8,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/P4115-w-measurements.jpg?v=1795452674"},{"product_id":"mtc-bio-3-ml-transfer-pipettes-short-bulb-graduated-to-1-ml","title":"MTC Bio 3 mL Transfer Pipettes, Short Bulb, Graduated to 1 mL","description":"\u003cp\u003e\u003cstrong\u003eMTC Bio 3 mL transfer pipettes with a short bulb graduated to 1 mL,\u003c\/strong\u003e bulk packs of 250 and sterile packs of 500, shipped from North American stock.\u003c\/p\u003e\n\u003cp\u003eA short bulb on a 3 mL body gives a controlled draw for one to two millilitres, which is the volume band most bench steps actually use. The graduation to 1 mL lets an operator estimate a small addition without reaching for a pipettor, and the shorter body fits a rack position where a 5 mL pipette would stand too tall.\u003c\/p\u003e\n\u003ch2\u003eWhat is in a case of 3 mL pipettes?\u003c\/h2\u003e\n\u003cp\u003eThe non-sterile bulk configuration holds 250 pipettes per pack and 20 packs per case, so 5,000 pipettes. The sterile individually wrapped configuration holds 500 per case.\u003c\/p\u003e\n\u003cp\u003eAt 250 per pack, an open pack covers a bench for a couple of weeks at 20 transfers a day, which keeps the case closed and the working pack fresh.\u003c\/p\u003e\n\u003cp\u003eA 250-pipette pack also fits a bench drawer, which is where a small-volume pipette usually ends up when the bench has no rack space for it.\u003c\/p\u003e\n\u003cp\u003eBoth configurations share the same body and graduation, so the sterile and bulk packs can sit on the same shelf without confusing the stock count.\u003c\/p\u003e\n\u003ch2\u003eShort bulb, 3 mL body — what is it for?\u003c\/h2\u003e\n\u003cp\u003eThe short bulb is a control feature: it limits the draw so a small volume does not shoot past the mark, and it gives a finer feel at the 0.5 to 1 mL end. That makes it the pipette for adding a reagent to a tube or a strip, where the volume is small but the count is high.\u003c\/p\u003e\n\u003cp\u003eWhere the volume is above 2 mL or the vessel is deep, step up to a 5 mL or 7 mL pipette rather than drawing twice: a second draw from the same pipette is where cross-contamination begins.\u003c\/p\u003e\n\u003cp\u003eThe 1 mL graduation is the useful mark on this pipette: most additions in a small-volume step are 0.1 to 1 mL, and a pipette that can show that band is faster than reaching for a pipettor for a single addition.\u003c\/p\u003e\n\u003cp\u003eA short bulb is also gentler on a cell suspension: a large bulb draws with more force and can shear cells at the tip, which matters when the suspension will be counted afterwards.\u003c\/p\u003e\n\u003ch2\u003eWhat are the specifications of the 3 mL transfer pipette?\u003c\/h2\u003e\n\u003cp\u003eEvery configuration below is a separate case line. The manufacturer reference is what appears on the quotation, the packing slip and the lot documentation, so quote it when you ask for a certificate of analysis.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eManufacturer reference\u003c\/th\u003e\n\u003cth\u003ePack\u003c\/th\u003e\n\u003cth\u003eCase\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 3mL · short bulb · graduated to 1mL · non-sterile ·\u003c\/td\u003e\n\u003ctd\u003eP4117-00\u003c\/td\u003e\n\u003ctd\u003e250 per pack\u003c\/td\u003e\n\u003ctd\u003e5,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer pipette · 3mL · short bulb · graduated to 1mL · sterile · ind\u003c\/td\u003e\n\u003ctd\u003eP4117-11\u003c\/td\u003e\n\u003ctd\u003e500 per pack\u003c\/td\u003e\n\u003ctd\u003e500 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHow many 3 mL pipettes does a bench use?\u003c\/h2\u003e\n\u003cp\u003eA bench doing 30 small additions a day uses 30 pipettes, about 650 a month, so a 5,000-pipette bulk case lasts seven months. A sterile user doing 15 transfers a day uses 320 a month, so a 500-count sterile case lasts six weeks.\u003c\/p\u003e\n\u003cp\u003eSmall-bulb pipettes are often shared across benches, so keep the working pack at the bench and the case in storage; a case that lives on the bench is a case that gets opened and left open.\u003c\/p\u003e\n\u003cp\u003eWhere a bench shares one pack between two operators, the pack is the unit to count: an empty pack is a signal to open the next, and a case with two open packs is how a bench ends up with pipettes in three places.\u003c\/p\u003e\n\u003cp\u003eA bench that adds reagent to strips in a plate will use one pipette per strip rather than per well, so the weekly count follows the strip count and not the sample count.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eWorking pattern\u003c\/th\u003e\n\u003cth\u003eUsed per month\u003c\/th\u003e\n\u003cth\u003eCase covers\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne bench, light use\u003c\/td\u003e\n\u003ctd\u003eabout 300 pieces\u003c\/td\u003e\n\u003ctd\u003eroughly 8 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne bench, full shift\u003c\/td\u003e\n\u003ctd\u003eabout 2,000 pieces\u003c\/td\u003e\n\u003ctd\u003eroughly 2 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwo benches\u003c\/td\u003e\n\u003ctd\u003eabout 4,000 pieces\u003c\/td\u003e\n\u003ctd\u003eunder one month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCounts above are planning figures from pack and case sizes on this page, not a forecast of your own consumption; check them against a week of your own bench records before setting a reorder point.\u003c\/p\u003e\n\u003ch2\u003eHow is it shipped, and how should it be stored?\u003c\/h2\u003e\n\u003cp\u003ePipettes ship from North American stock, 1 to 2 business days in Ontario, 2 to 4 across Canada, 2 to 3 to US addresses. The sterile pack carries the manufacturer reference and lot.\u003c\/p\u003e\n\u003cp\u003eStore the case closed, away from heat and direct sunlight: polyethylene softens in a warm vehicle and a deformed bulb will not draw the marked volume.\u003c\/p\u003e\n\u003cp\u003eA sterile wrapper that has been opened and left on the bench is no longer sterile, so open only the pipettes the session needs rather than the whole pack.\u003c\/p\u003e\n\u003ch2\u003eWhat we do not claim\u003c\/h2\u003e\n\u003cp\u003eSingle-use laboratory consumables for liquid transfer. Not sold as medical devices for patient treatment. The graduation is a moulded estimate rather than a calibrated measurement; sterility is the manufacturer's stated value per configuration.\u003c\/p\u003e\n\u003cp\u003eWhat we cannot do is confirm a delivered volume for an uncalibrated pipette: send the tolerance your step needs and we will say whether this pipette or a pipettor is the right tool.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eHow many pipettes per case?\u003c\/summary\u003e\u003cp\u003eThe non-sterile bulk configuration is 5,000 per case in 20 packs of 250; the sterile individually wrapped configuration is 500 per case.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat does short bulb mean?\u003c\/summary\u003e\u003cp\u003eA smaller bulb that limits the draw and gives finer control at 0.5 to 1 mL, which keeps a small addition from passing the mark.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs the graduation to 1 mL accurate?\u003c\/summary\u003e\u003cp\u003eIt is a moulded estimate for transfer work; a step that needs a measured volume should use a calibrated tool.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eAre sterile pipettes individually wrapped?\u003c\/summary\u003e\u003cp\u003eYes, the sterile configuration is individually wrapped, 500 per case.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I use it for cell culture?\u003c\/summary\u003e\u003cp\u003eThe sterile wrapped configuration is the one intended for sterile work; the bulk pack is for non-sterile steps.\u003c\/p\u003e\u003c\/details\u003e\n\u003ch2\u003eChoosing the right option\u003c\/h2\u003e\u003cp\u003eRelated products in the same laboratory line:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/products\/specimen-container-120ml-sterile-screw-cap-100-pack\"\u003especimen container 120ml sterile screw cap 100 pack\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/products\/mtc-bio-sureseal-s-1-5ml-sterile-microcentrifuge-tubes-500-pack\"\u003emtc bio sureseal s 1 5ml sterile microcentrifuge tubes 500 pack\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eBackground reading before you order:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/transfer-pipettes-vs-serological-pipettes\"\u003etransfer pipettes vs serological pipettes\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"\/fr\/products\/specimen-container-120ml-sterile-screw-cap-100-pack\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/P4117-w-measurements.jpg?v=1795452690\" alt=\"Laboratory consumables\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"MTC Bio","offers":[{"title":"Transfer pipette · 3mL · short bulb · graduated to 1mL · non-sterile · bulk","offer_id":49487126954206,"sku":"CLI-TPIP-3-P4117-00","price":408.11,"currency_code":"CAD","in_stock":true},{"title":"Transfer pipette · 3mL · short bulb · graduated to 1mL · sterile · individu","offer_id":49487794798814,"sku":"CLI-TPIP-3-P4117-11","price":89.8,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/P4117-w-measurements.jpg?v=1795452690"}],"url":"https:\/\/clinieco.ca\/fr\/collections\/lab-transfer.oembed","provider":"CliniEco Medical","version":"1.0","type":"link"}