{"title":"Injection \u0026 Anaesthesia Supplies","description":"\u003ch2\u003eWhat this collection is for\u003c\/h2\u003e\n\u003cp\u003eInjection and anaesthesia supplies are the consumables a clinic re-orders on a cycle: needles, syringes, winged infusion sets, alcohol prep pads and the cartridges used for skin treatments. The list below is organised by the decision a buyer actually makes — gauge and length first, then barrel size, then the accessory that goes with the procedure. Every item here ships from Toronto and is stocked for repeat clinic orders.\u003c\/p\u003e\n\n\u003ch2\u003eChoosing needle gauge and length first\u003c\/h2\u003e\n\u003cp\u003eGauge is the outside diameter of the needle: a larger number is a thinner needle. Length is chosen by the depth the injection has to reach, not by patient preference. The table below is the range stocked for clinic work, with the use each size is normally ordered for.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eGauge and length\u003c\/th\u003e\n\u003cth\u003eTypical clinic use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e32G × 4 mm pen needle\u003c\/td\u003e\n\u003ctd\u003eInsulin pen injections; the shortest pen needle stocked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e31G × 5\/16\" (8 mm)\u003c\/td\u003e\n\u003ctd\u003eLow-volume subcutaneous injection from a 1 cc syringe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e23G × 3\/4\" winged set\u003c\/td\u003e\n\u003ctd\u003eShort infusion or blood draw where a hub is easier to hold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThinner needles are not automatically less painful for every procedure: a very fine needle that has to be pushed harder can be worse than one size up. Order the gauge that matches the viscosity of what you are injecting and the depth required.\u003c\/p\u003e\n\n\u003ch2\u003eSyringe barrel sizes and graduations\u003c\/h2\u003e\n\u003cp\u003eBarrel size follows the volume you draw, and the graduation has to be readable at that volume. A 1 cc barrel is ordered when the dose is measured in units or tenths of a millilitre; larger barrels are used when the dose is measured in whole millilitres. The 1 cc insulin syringe in this collection is ordered in boxes of 100, which is the unit most clinics use to size a month of use.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/fr\/products\/insulin-syringes-1cc-31g-100-box\"\u003eCliniEco insulin syringes 1 cc, 31G × 5\/16\" — 100 per box\u003c\/a\u003e and \u003ca href=\"\/fr\/products\/insulin-pen-needles-32g-4mm-100-box\"\u003eCliniEco insulin pen needles 32G × 4 mm — 100 per box\u003c\/a\u003e are the two insulin-delivery consumables most often ordered together; the pen needle is only needed where a pen is used rather than a syringe.\u003c\/p\u003e\n\n\u003ch2\u003eWinged infusion (butterfly) sets\u003c\/h2\u003e\n\u003cp\u003eA winged set gives a hub that can be held flat against the skin and taped down, which is why it is ordered for short infusions and for draws where the vein is small. \u003ca href=\"\/fr\/products\/winged-infusion-set-23g-3-4-inch-50-box\"\u003eCliniEco winged infusion sets 23G × 3\/4\" — 50 per box\u003c\/a\u003e are stocked in the gauge most clinics keep on the treatment cart.\u003c\/p\u003e\n\n\u003ch2\u003eAlcohol prep pads and site preparation\u003c\/h2\u003e\n\u003cp\u003ePrep pads are the highest-frequency item in this group and the one most often under-ordered, because a clinic goes through several per procedure. \u003ca href=\"\/fr\/products\/clinieco-medical-alcohol-prep-pads-70-isopropyl-200-pack\"\u003eCliniEco alcohol prep pads, 70% isopropyl — 200 per box\u003c\/a\u003e are ordered in multiples of the box so the treatment room and the storage shelf are both stocked. Wipe the site and let it dry before the needle goes in; a wet site stings and reduces the friction that keeps the needle from slipping.\u003c\/p\u003e\n\n\u003ch2\u003eAesthetic injection supplies\u003c\/h2\u003e\n\u003cp\u003eWhere the clinic also does skin treatments, the injection supplies are different in one respect: the cartridge and cannula are matched to the device, so the two are ordered as a set. \u003ca href=\"\/fr\/products\/clinieco-sterile-microneedle-cartridges-14-pin-10-pack\"\u003eCliniEco sterile microneedle cartridges, 14-pin — 10 per pack\u003c\/a\u003e and \u003ca href=\"\/fr\/products\/clinieco-sterile-blunt-fill-cannula-aesthetic-20-pack\"\u003eCliniEco sterile blunt fill cannula — 20 per pack\u003c\/a\u003e are both EO sterilised and single use. Check the device manual for the cartridge that fits before ordering a case.\u003c\/p\u003e\n\n\u003ch2\u003eStorage, expiry and record keeping\u003c\/h2\u003e\n\u003cp\u003eAll of the items above are sterile, single use and date coded. Keep them in the original box until use, store away from heat and light, and rotate stock so the earliest expiry is at the front of the shelf. If the clinic keeps an infection-control log, record the lot number of the box in use, not of the case behind it, so a recall can be traced to what was actually opened.\u003c\/p\u003e\n\n\u003ch2\u003eOrdering for a clinic in Canada\u003c\/h2\u003e\n\u003cp\u003eEvery item in this collection can be ordered from the product page without an account, in the box quantity listed. Clinics ordering several lines at once can use the \u003ca href=\"\/fr\/collections\/clinic-consumables\"\u003eclinic consumables collection\u003c\/a\u003e to build a single order, and the \u003ca href=\"\/fr\/collections\/b2b-wholesale\"\u003eclinic and volume supply\u003c\/a\u003e page for case quantities. Needles, syringes and pads are re-order items: size the first order from a month of actual use and keep the rest on a standing cycle rather than ordering when the shelf runs out.\u003c\/p\u003e","products":[{"product_id":"clinieco-medical-alcohol-prep-pads-70-isopropyl-200-pack","title":"Alcohol Prep Pads, 70% Isopropyl, 200 per Box","description":"\u003cp\u003e\u003cstrong\u003eAlcohol Prep Pads — 70% Isopropyl, Individually Wrapped\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIndividually foil-wrapped pads saturated with 70% isopropyl alcohol, USP grade. Medium-size, 2-ply non-woven pads.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/alcohol-prep-pads-size-saturation-and-sterility-guide\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/309ab1879edcf427124d5daa0c80ebad.png?v=1791825494\" alt=\"Alcohol Prep Pads — 70% Isopropyl, 200-Pack\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eWhat are individually wrapped alcohol prep pads used for?\u003c\/h2\u003e\n\u003cp\u003eThey are a small-surface, single-use format: wiping a vial stopper before a draw, cleaning a cuff or a stethoscope between patients, degreasing a small equipment surface, and any point in your procedure protocol that names a 70% isopropyl wipe. The foil pouch is what makes them usable in a room and on a tray — one pad, one task, then discard, with no bottle to carry and nothing to re-cap.\u003c\/p\u003e\n\u003ch2\u003eWhy is 70% isopropyl the concentration this pad ships at?\u003c\/h2\u003e\n\u003cp\u003eThe pad is saturated at 70% isopropyl alcohol, USP grade, and that is the figure printed for this SKU — not a range and not a marketing claim. What a pad can and cannot be used on is decided by your own procedure documents and by the label of whatever product you are cleaning, so read those before substituting a pad for a surface disinfectant. Higher strength is not automatically the right choice for a given task, and this listing does not offer one.\u003c\/p\u003e\n\u003ch2\u003eWhere does a prep pad stop and a surface disinfectant start?\u003c\/h2\u003e\n\u003cp\u003eA prep pad is a small, single-use wipe: it covers a vial stopper, a small device surface or a point-of-care item. A surface disinfectant is a separate product whose label names the organisms it is intended for and the contact time it needs to stay wet; it is applied to a larger surface and left alone. Substituting one for the other is the common failure in a busy room, and it is worth writing the boundary into your cleaning schedule rather than leaving it to habit.\u003c\/p\u003e\n\u003ch2\u003eHow many pads come in a box and in a case?\u003c\/h2\u003e\n\u003cp\u003eOne box holds 200 pads; the bulk case is ten boxes, 2,000 pads. Both variants are on the same product page, so order by the variant name rather than by the size of the carton: booking a 2,000-pad case in as a 200-pad box is how a clinic ends up reordering a week early. Counting is easier if you count pads per procedure rather than pads per room — a number that comes straight out of your own protocol.\u003c\/p\u003e\n\u003ch2\u003eHow should the boxes be stored?\u003c\/h2\u003e\n\u003cp\u003eClosed, dry and away from heat and ignition sources, with the foil pouches intact — a punctured pouch is a dried pad. Rotate first in, first out against the expiry on the carton and keep the case off the floor so it is not wiped down with the mop water. Pads are single use: a pad that has touched a surface goes in the waste, not back in a pocket.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eAlcohol prep pads: the specification as listed\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003ctd\u003e70% isopropyl alcohol, USP grade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePad\u003c\/td\u003e\n\u003ctd\u003e2-ply non-woven, medium size, lint-free, low residue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging\u003c\/td\u003e\n\u003ctd\u003eIndividually foil-wrapped, single use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBox\u003c\/td\u003e\n\u003ctd\u003e200 pads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBulk case\u003c\/td\u003e\n\u003ctd\u003e10 boxes — 2,000 pads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSold as\u003c\/td\u003e\n\u003ctd\u003eSingle box or Bulk 10-Box (two variants on one page)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended use\u003c\/td\u003e\n\u003ctd\u003eSmall surfaces and equipment, per your procedure protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNot a substitute for\u003c\/td\u003e\n\u003ctd\u003eA labelled surface disinfectant with a stated contact time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003ctd\u003eCliniEco Medical, MDEL #35334\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSize the monthly box count on the \u003ca href=\"\/fr\/pages\/clinic-supply-planner\"\u003eclinic supply planner\u003c\/a\u003e, print the surface-cleaning schedule from the \u003ca href=\"\/fr\/pages\/compliance-log-center\"\u003ecompliance log centre\u003c\/a\u003e, and put a disinfection-policy question to \u003ca href=\"\/fr\/pages\/sterilization-compliance-consultation\"\u003ethe compliance desk\u003c\/a\u003e. Larger facilities bundle pads with \u003ca href=\"\/fr\/products\/disposable-washcloths-10x13-inch-500-case\"\u003e10 × 13 inch disposable washcloths, 500 per case\u003c\/a\u003e for the wipe-down itself, the \u003ca href=\"\/fr\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003e1:400–1:600 ultrasonic multi-enzyme concentrate\u003c\/a\u003e for the bath, and \u003ca href=\"\/fr\/products\/clinieco-foam-hand-sanitizer-1200ml-refill\"\u003e1200 ml foam hand sanitizer refills\u003c\/a\u003e for the dispensers; multi-site orders go through \u003ca href=\"\/fr\/pages\/wholesale\"\u003eour clinic ordering desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eShips from Toronto by CliniEco Medical — MDEL #35334.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e70% isopropyl alcohol, USP grade\u003c\/li\u003e\n\u003cli\u003e2-ply non-woven pad, medium size\u003c\/li\u003e\n\u003cli\u003eIndividually foil-wrapped, single use\u003c\/li\u003e\n\u003cli\u003eLint-free and low-residue\u003c\/li\u003e\n\u003cli\u003e200 pads per box\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle box: 200 pads\u003c\/li\u003e\n\u003cli\u003eBulk case: 10 boxes \/ 2,000 pads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping\u003c\/h3\u003e\n\u003cp\u003eShips from Toronto, Ontario. Orders placed on business days are dispatched within 24 hours.\u003c\/p\u003e\n\u003cp\u003eCliniEco Medical is a Canadian medical supply supplier serving clinics and healthcare facilities across Canada.\u003c\/p\u003e\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/alcohol-70-vs-91-which-isopropyl-concentration-works-better-for-disinfection\"\u003eAlcohol 70 vs 91: Which Isopropyl Concentration Works Better?\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/70-vs-91-isopropyl-alcohol-clinic-use-comparison\"\u003e70% vs 91% Isopropyl Alcohol: Which One Belongs in Your Clinic?\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/70-vs-91-isopropyl-alcohol-whats-the-difference-for-prep-pads\"\u003e70% vs 91% Isopropyl Alcohol: Which Is Better for Prep Pads \u0026amp; Disinfection?\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Single Box","offer_id":48545879556318,"sku":"CLI-ALC-PAD-200","price":8.99,"currency_code":"CAD","in_stock":true},{"title":"Bulk 10-Box","offer_id":48595343474910,"sku":"CLI-ALC-PAD-200-CASE10","price":71.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/ALCOHOL-PAD-HERO-nologo-V2-20261110.jpg?v=1794349739"},{"product_id":"clinieco-sterile-microneedle-cartridges-14-pin-10-pack","title":"CliniEco Sterile Microneedle Cartridges — 14-Pin, EO Sterilized, 10-Pack","description":"\u003cdiv class=\"product-description\"\u003e\n\u003cp\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/microneedling-cartridge-verification-restock-canada\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/clinieco-microneedle-cartridges-14pin-hero1500.jpg?v=1793633910\" alt=\"CliniEco Sterile Microneedle Cartridges — 14-Pin, EO Sterilized, 10-Pack\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eSterile, Single-Use Microneedle Cartridges \u003c\/h2\u003e\n\u003cp\u003eCliniEco Sterile Microneedle Cartridges are being introduced for professional derma pens used in Canadian medical aesthetics clinics. Each cartridge is EO-sterilized (ISO 11135) and individually blister-packed for single-use safety.\u003c\/p\u003e\n\u003ch2\u003eWhich needle depth should a med spa stock?\u003c\/h2\u003e\n\u003cp\u003eDepth is set on the pen and per treatment protocol rather than chosen by the cartridge, so the question a stock list answers is coverage — and the line that goes with these cartridges is the \u003ca href=\"\/fr\/products\/clinieco-sterile-blunt-fill-cannula-aesthetic-20-pack\"\u003eblunt fill cannula range\u003c\/a\u003e for the filler side of the same appointment. The cartridges are listed as compatible with adjustable needle depth from 0.25 to 3.0 mm, which spans the range a professional derma pen is set to across treatments, so stocking the 14-pin configuration means one box covers the pen a clinic already owns instead of a depth-specific SKU per protocol. Depth selection itself stays with the treating clinician and the device settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeedle depth:\u003c\/strong\u003e Compatible with adjustable depth 0.25–3.0 mm set on the pen\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePen compatibility:\u003c\/strong\u003e Professional derma pens; no specific pen model is named on this listing\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSterilisation:\u003c\/strong\u003e EO sterilised per ISO 11135; residual testing per ISO 10993-7\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Individually blister-packed; 10-pcs retail box\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUse:\u003c\/strong\u003e Single use\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeedle depth:\u003c\/strong\u003e Compatible with adjustable depth 0.25–3.0 mm set on the pen\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePen compatibility:\u003c\/strong\u003e Professional derma pens; no specific pen model is named on this listing\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSterilisation:\u003c\/strong\u003e EO sterilised per ISO 11135; residual testing per ISO 10993-7\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Individually blister-packed; 10-pcs retail box\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUse:\u003c\/strong\u003e Single use\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eMicroneedle cartridge: configuration\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eField\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin count\u003c\/td\u003e\n\u003ctd\u003e14-pin (North American standard); 12, 36 and Nano variants planned\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeedle depth\u003c\/td\u003e\n\u003ctd\u003eCompatible with adjustable depth 0.25–3.0 mm set on the pen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePen compatibility\u003c\/td\u003e\n\u003ctd\u003eProfessional derma pens; no specific pen model is named on this listing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterilisation\u003c\/td\u003e\n\u003ctd\u003eEO sterilised per ISO 11135; residual testing per ISO 10993-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging\u003c\/td\u003e\n\u003ctd\u003eIndividually blister-packed; 10-pcs retail box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUse\u003c\/td\u003e\n\u003ctd\u003eSingle use\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHow is each cartridge sterilised and packed?\u003c\/h2\u003e\n\u003cp\u003eEthylene oxide to ISO 11135, with residual testing per ISO 10993-7, and each cartridge individually blister-packed so a box can be opened without exposing the rest — the anti-backflow design is described as preventing cross-contamination. For a clinic the two facts matter together: the sterilisation claim is what goes in a supplier file, and the blister pack is what makes the single-use rule workable at the chair, because one cartridge is opened per treatment rather than a tray of them. The rest of the aesthetic line, including the \u003ca href=\"\/fr\/products\/clinieco-repair-mask-hydrating-6-masks-post-procedure-sheet-mask\"\u003epost-procedure repair mask\u003c\/a\u003e, is grouped under \u003ca href=\"\/fr\/collections\/medical-aesthetics\"\u003emedical aesthetics\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003ePlanned Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e14-pin configuration (North American standard), 12\/36\/Nano variants planned\u003c\/li\u003e\n\u003cli\u003eAdjustable needle depth 0.25–3.0mm compatibility\u003c\/li\u003e\n\u003cli\u003eAnti-backflow design to prevent cross-contamination\u003c\/li\u003e\n\u003cli\u003eEO sterilized per ISO 11135; residual testing per ISO 10993-7\u003c\/li\u003e\n\u003cli\u003eSingle-use, individually blister packed; 10-pcs retail box\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompliance Note\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRegister your interest and we will confirm the Canadian release date and shipping window once stock is confirmed.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eCliniEco Medical — Canadian medical supply brand. \u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/where-to-buy-professional-derma-pen-medical-aesthetics-calgary\"\u003eWhere to Buy Professional Derma Pen for Medical Aesthetics Clinics in Calgary\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/which-led-face-mask-medical-aesthetics-quebec\"\u003eWhich LED Face Mask Do Medical Aesthetics Clinics in Quebec Order? Sizes and Case Formats\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":49004123979998,"sku":"CLI-AES-MN-CART-10","price":39.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/clinieco-microneedle-cartridges-14pin-hero1500.jpg?v=1793633910"},{"product_id":"clinieco-sterile-blunt-fill-cannula-aesthetic-20-pack","title":"CliniEco Sterile Blunt Fill Cannula — Aesthetic Injection, 20-Pack","description":"\u003cdiv class=\"product-description\"\u003e\n\u003cp\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/sterile-field-setup-in-clinic-injectables-canada\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/clinieco-blunt-fill-cannula-placeholder-en.jpg?v=1793633914\" alt=\"CliniEco Sterile Blunt Fill Cannula — Aesthetic Injection, 20-Pack\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003ePrecision Blunt-Tip Microcannulas for Aesthetic Medicine \u003c\/h2\u003e\n\u003cp\u003eCliniEco Sterile Blunt Fill Cannulas are being introduced for aesthetic practitioners performing dermal filler procedures. Blunt-tip microcannula design reduces bruising and tissue trauma compared to sharp needles.\u003c\/p\u003e\n\u003ch2\u003eHow does a blunt-tip cannula differ from a sharp needle?\u003c\/h2\u003e\n\u003cp\u003eThe tip is the difference: a blunt, atraumatic end with a rounded side port, which is described on this listing as reducing bruising and tissue trauma compared with sharp needles. Product leaves through the side port rather than through the point, so the cannula can move through tissue along a plane instead of cutting a track, and the Luer-lock hub is what lets it sit on a standard syringe. In the aesthetic line these sit alongside the \u003ca href=\"\/fr\/products\/clinieco-sterile-microneedle-cartridges-14-pin-10-pack\"\u003e14-pin microneedle cartridges\u003c\/a\u003e, and both are grouped under \u003ca href=\"\/fr\/collections\/medical-aesthetics\"\u003emedical aesthetics\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge options:\u003c\/strong\u003e 25G, 27G, 30G\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLength options:\u003c\/strong\u003e Long and short for each gauge\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTip:\u003c\/strong\u003e Blunt, atraumatic, with a rounded side port\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHub:\u003c\/strong\u003e Luer-lock compatible\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSterility:\u003c\/strong\u003e Sterile, single use, EO sterilized\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e 20-pack clinic box\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge options:\u003c\/strong\u003e 25G, 27G, 30G\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLength options:\u003c\/strong\u003e Long and short for each gauge\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTip:\u003c\/strong\u003e Blunt, atraumatic, with a rounded side port\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHub:\u003c\/strong\u003e Luer-lock compatible\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSterility:\u003c\/strong\u003e Sterile, single use, EO sterilized\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e 20-pack clinic box\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eBlunt fill cannula: planned configuration\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eField\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge options\u003c\/td\u003e\n\u003ctd\u003e25G, 27G, 30G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength options\u003c\/td\u003e\n\u003ctd\u003eLong and short for each gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip\u003c\/td\u003e\n\u003ctd\u003eBlunt, atraumatic, with a rounded side port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHub\u003c\/td\u003e\n\u003ctd\u003eLuer-lock compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterility\u003c\/td\u003e\n\u003ctd\u003eSterile, single use, EO sterilized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging\u003c\/td\u003e\n\u003ctd\u003e20-pack clinic box\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWhat the listing fixes today is the format rather than a final size list: 25G, 27G and 30G are named as the gauge options, each in long and short, with the final size list confirmed with the supplier before sale. Read as three columns, the gauge sets how much filler moves per pass, the length sets whether the cannula reaches a fold or a plane, and the side port is where product exits. A clinic should treat the table as the configuration to plan around rather than a catalogue of stocked sizes.\u003c\/p\u003e\n\u003ch2\u003ePlanned Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMultiple gauge options: 25G, 27G, 30G (long \u0026amp; short)\u003c\/li\u003e\n\u003cli\u003eBlunt, atraumatic tip with rounded side port\u003c\/li\u003e\n\u003cli\u003eSterile, single-use, EO sterilized\u003c\/li\u003e\n\u003cli\u003eLuer-lock compatible\u003c\/li\u003e\n\u003cli\u003e20-pack clinic box\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompliance Note\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRegister your interest and we will confirm the Canadian release date and shipping window once stock is confirmed.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eCliniEco Medical — Canadian medical supply brand. \u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat sizes are available?\u003c\/h3\u003e\n\u003cp\u003eThe blunt fill cannula range includes commonly used gauges for aesthetic injection. Final size list is confirmed with the supplier before sale.\u003c\/p\u003e\n\u003ch3\u003eAre the cannulas sterile and single-use?\u003c\/h3\u003e\n\u003cp\u003eYes. Each cannula is sterile and intended for single use to support injection safety protocols.\u003c\/p\u003e\n\u003ch3\u003eWhat procedures are blunt fill cannulas used for?\u003c\/h3\u003e\n\u003cp\u003eBlunt-tip cannulas are commonly used for dermal filler placement, reducing the risk of vascular complications compared with sharp needles.\u003c\/p\u003e\n\u003ch3\u003eDoes CliniEco supply clinics and medspas in Canada?\u003c\/h3\u003e\n\u003cp\u003eYes, we supply regulated devices to Canadian professionals.\u003c\/p\u003e\n\u003ch3\u003eIs this available for pre-order?\u003c\/h3\u003e\n\u003cp\u003eThis item is listed as a pre-order placeholder; stock timing will be confirmed with the supplier.\u003c\/p\u003e\n\n\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/where-to-buy-professional-derma-pen-medical-aesthetics-calgary\"\u003eWhere to Buy Professional Derma Pen for Medical Aesthetics Clinics in Calgary\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/which-led-face-mask-medical-aesthetics-quebec\"\u003eWhich LED Face Mask Do Medical Aesthetics Clinics in Quebec Order? Sizes and Case Formats\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":49004124143838,"sku":"CLI-AES-CANNULA-20","price":129.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/clinieco-blunt-fill-cannula-placeholder-en.jpg?v=1793633914"},{"product_id":"insulin-syringes-1cc-31g-100-box","title":"Insulin Syringes 1 cc — 31G × 5\/16\", 100\/Box","description":"\u003cp\u003eInsulin syringes with a 1 mL barrel and a 31 gauge needle, supplied 100 per box. The 1 mL barrel with half-unit or unit graduations is the format used for the smallest doses, where a larger barrel would make the dose hard to read.\u003c\/p\u003e\n\u003cp\u003eThis page documents the specification, sizing logic and sourcing position for these syringes for Canadian clinics, pharmacies, diabetes education programs and care homes.\u003c\/p\u003e\n\u003ch2\u003eWho it is for\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDiabetes education and outpatient clinics\u003c\/li\u003e\n\u003cli\u003eCommunity pharmacies running injection programs\u003c\/li\u003e\n\u003cli\u003eLong-term care homes administering insulin\u003c\/li\u003e\n\u003cli\u003ePublic health and travel clinics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBarrel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mL with fine graduations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeedle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31G, short bevel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntended use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulin administration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecification listing — availability pending supplier documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhy does syringe barrel size matter for insulin?\u003c\/h3\u003e\n\u003cp\u003eDose accuracy. A 1 mL barrel gives more space between graduations than a 3 mL barrel, so small doses are easier to read — which is also why insulin is commonly supplied in dedicated 0.3 mL, 0.5 mL and 1 mL formats.\u003c\/p\u003e\n\u003ch3\u003eWhat does 31G mean?\u003c\/h3\u003e\n\u003cp\u003eNeedle gauge, or outside diameter: 31G is thinner than 29G or 30G, which usually means less injection discomfort. Thin needles require more care with injection technique.\u003c\/p\u003e\n\u003ch3\u003eCan facilities buy syringes without a prescription?\u003c\/h3\u003e\n\u003cp\u003eIn Canada, the licensing classification of the device determines what documentation a supplier must hold. This listing is being prepared against that requirement; pricing and ordering will be enabled once it is complete.\u003c\/p\u003e\n\u003ch3\u003eHow do I ask about volume supply?\u003c\/h3\u003e\n\u003cp\u003eUse our B2B enquiry form. We will confirm documentation status and lead times.\u003c\/p\u003e\n\u003ch2\u003eWhat do 1 cc, 31G and 5\/16 inch each specify?\u003c\/h2\u003e\n\u003cp\u003eThree numbers, three different jobs. One cc is one millilitre of barrel capacity, and on a U-100 scale that barrel holds 100 units, so each unit is one hundredth of the barrel. 31G is the needle's outside diameter: 0.25 mm in the ISO 9626:2016 designated size series, finer than 30G at 0.30 mm and coarser than 32G at 0.23 mm. Five sixteenths of an inch is 7.94 mm of needle length, a short needle that reaches subcutaneous fat in most adults. The barrel is the part that decides dose accuracy, because graduation spacing shrinks as capacity grows: a 1 mL barrel leaves visibly more space between marks than a 3 mL barrel for the same dose. That is why insulin is drawn in 0.3, 0.5 or 1 mL formats rather than in whatever general-purpose syringe is nearest to hand.\u003c\/p\u003e\n\u003ch2\u003eWhich standard covers an insulin syringe, and which one does not?\u003c\/h2\u003e\n\u003cp\u003eISO 8537:2016 is the document written for this device: sterile, single-use syringes, with or without needle, intended solely for the injection of insulin and filled by the end user. ISO 7886-1:2017, the general standard for manual single-use hypodermic syringes, states in its scope that it excludes syringes for use with insulin and points instead to ISO 8537. A supplier sheet that cites only ISO 7886-1 for an insulin syringe is citing the wrong document, even when the same factory makes both product lines. Tubing dimensions come from ISO 9626:2016, sterilisation from ISO 11135:2014 or the ISO 11137 series, the sterile barrier from ISO 11607-1:2019, and the manufacturer's quality system should be certified to ISO 13485:2016. Both were confirmed as current at their last review, and both have a replacement in progress at ISO, so the edition belongs on the specification sheet.\u003c\/p\u003e\n\u003ch2\u003eWhy does the concentration on the vial have to match the scale?\u003c\/h2\u003e\n\u003cp\u003eA U-100 vial contains 100 units of insulin per millilitre, the concentration used for almost all human insulin supplied in Canada. Higher-strength products, U-200 and U-300, are supplied in pens built for that concentration. Drawing a U-200 or U-300 product into a U-100 syringe multiplies the intended dose by two or three, turning a 10-unit dose into 20 or 30 units with no visible change on the scale. Keep the vial and the syringe in the same conversation: a U-100 syringe is for U-100 insulin, and any product supplied in a pen stays in its pen. If a clinic holds more than one concentration, store them apart and label the shelf, not only the carton.\u003c\/p\u003e\n\u003ch2\u003eHow much insulin stays in the syringe after the plunger is fully depressed?\u003c\/h2\u003e\n\u003cp\u003eSome volume always remains in the hub and the needle, and no amount of plunger pressure moves it. That residual is a design property of the syringe, so it should be a stated number in millilitres rather than a figure a buyer estimates from a drawing. It matters most at the small end: a 2-unit dose from a syringe with a large hub residual delivers proportionally less insulin than a 20-unit dose from the same syringe. Ask for the measured residual volume and the method used to obtain it, and write it beside the product code in the protocol, because one clinic can hold two syringe brands with different hubs and one shared procedure.\u003c\/p\u003e\n\u003ch2\u003eWhat belongs in the batch record and the clinic protocol?\u003c\/h2\u003e\n\u003cp\u003eSingle use with no recapping by hand; a sharps container within reach at every injection point; gloves changed between patients when staff give the injection; storage that keeps the carton dry and away from direct heat; and lot traceability from receipt through to the patient record. Waste is provincial: in Ontario, human blood waste is listed in Table A of guideline C-4 with a yellow label and the universal biohazard symbol, while other provinces publish their own rules for the same stream. Our \u003ca href=\"\/fr\/products\/sterile-blood-lancets-33g-100-box\"\u003e33G blood lancets\u003c\/a\u003e, \u003ca href=\"\/fr\/products\/insulin-pen-needles-32g-4mm-100-box\"\u003e32G pen needles\u003c\/a\u003e and \u003ca href=\"\/fr\/products\/sharps-container-1-quart-20-case\"\u003e1-quart sharps container\u003c\/a\u003e carry the same documentation pattern, and volume requirements run through the \u003ca href=\"\/fr\/pages\/wholesale\"\u003ewholesale enquiry desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eInsulin syringe 1 cc × 31G × 5\/16 inch: specification and verification\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eAs listed on this page\u003c\/th\u003e\n\u003cth\u003eWhat to verify on the record\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarrel\u003c\/td\u003e\n\u003ctd\u003e1 mL with fine graduations\u003c\/td\u003e\n\u003ctd\u003eScale is U-100 (100 units per mL) and matches the vial in use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeedle gauge\u003c\/td\u003e\n\u003ctd\u003e31G\u003c\/td\u003e\n\u003ctd\u003e0.25 mm nominal outside diameter to ISO 9626:2016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeedle length\u003c\/td\u003e\n\u003ctd\u003e5\/16 inch (7.94 mm)\u003c\/td\u003e\n\u003ctd\u003eMeasured length and label agree with the requisition code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeedle attachment\u003c\/td\u003e\n\u003ctd\u003eFixed needle, single use\u003c\/td\u003e\n\u003ctd\u003eHub drawing, and no separate needle to attach\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct standard\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eDeclaration citing ISO 8537:2016; not ISO 7886-1 alone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterilisation\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eISO 11135:2014 for ethylene oxide, or the ISO 11137 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterile barrier\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eISO 11607-1:2019 qualification, with shelf life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual volume\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eMeasured hub and needle dead space, in mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality system\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eISO 13485:2016 certificate held by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003ctd\u003eCliniEco Medical, MDEL #35334\u003c\/td\u003e\n\u003ctd\u003eLicence number recorded on the supplier file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCliniEco Medical distributes injection consumables in Canada under MDEL #35334. This section is a specification reference for organisations building an insulin supply list; device and dose decisions stay with the treating team.\u003c\/p\u003e\n\u003ch2\u003eRelated reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/diabetes-management-supplies-canadian-patients-glucometers-test-strips\"\u003eDiabetes management supplies: glucometers, strips and lancets\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/medical-device-licensing-in-canada-class-i-vs-class-ii-vs-class-iv-explained\"\u003eMedical device classes in Canada explained\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/diabetes-education-clinic-supplies-foot-exam-and-injection-stock\"\u003eDiabetes education clinic supplies\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eListing note:\u003c\/em\u003e this page is published ahead of full catalogue onboarding so that specifications, documentation and sourcing details are available in one place. Pricing and ordering will be enabled once supplier documentation is complete. To be notified or to discuss volume requirements, use our \u003ca href=\"\/fr\/pages\/wholesale\"\u003eB2B enquiry form\u003c\/a\u003e.\u003c\/p\u003e\n","brand":"CliniEco Medical","offers":[{"title":"2-Pack","offer_id":49081998999774,"sku":"CLI-INSSYR-100-2PK","price":69.98,"currency_code":"CAD","in_stock":true},{"title":"Single","offer_id":49039190032606,"sku":"CLI-INSSYR-100","price":34.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/insulin-syringes-1cc-31g-100-box-1.jpg?v=1789404341"},{"product_id":"insulin-pen-needles-32g-4mm-100-box","title":"Insulin Pen Needles 32G × 4 mm — 100\/Box","description":"\u003cp\u003eInsulin pen needles measuring 32G with a 4 mm length, supplied 100 per box. 4 mm is the shortest commonly used pen needle length and is appropriate for most adults regardless of body size, provided injection technique lifts the skin appropriately.\u003c\/p\u003e\n\u003cp\u003eThis page documents the specification for organisations that standardise pen needles as part of an insulin supply list — clinics, care homes and diabetes education programs.\u003c\/p\u003e\n\u003ch2\u003eWhat does 32G × 4 mm actually specify?\u003c\/h2\u003e\n\u003cp\u003eGauge describes the outside diameter of the cannula, not its bore. 32G sits at 0.23 mm nominal outside diameter in the ISO 9626:2016 gauge series, which runs from 0.18 mm (34G) to 3.4 mm (10G). Wall thickness decides the inner diameter, so two needles both marked 32G can differ in flow and in the force needed to deliver a dose; thin-wall and extra-thin-wall variants are not the same product. Length is measured from the hub shoulder to the tip, and 4 mm is the short end of the adult range. Four millimetres reaches subcutaneous fat in most adults, including adults with a higher body mass index, which is why guidance moved away from 8 mm and 12 mm as default lengths. It is not universal: very young children, very lean adults and anyone injecting into a lifted skin fold need a clinical decision, and the injection technique (straight in at 90 degrees with or without a lift) belongs in the written protocol next to the product code.\u003c\/p\u003e\n\u003ch2\u003eWhich standard should the supplier's test report cite?\u003c\/h2\u003e\n\u003cp\u003eDouble-ended pen needles are covered by ISO 11608-2:2022, third edition, which refers to ISO 11608-1 for dose accuracy and functional compatibility and adapts the needle requirements of ISO 7864:2016; the tubing dimensions come from ISO 9626:2016. Sterility and the sterile barrier are separate questions: ask whether the process is validated to ISO 11135:2014 for ethylene oxide or to the ISO 11137 series for radiation, and whether the packaging system is qualified to ISO 11607-1:2019. A manufacturer working to ISO 13485:2016 can produce those reports on request. Distributors in Canada hold a Medical Device Establishment Licence; CliniEco Medical operates under MDEL #35334. A specification sheet that cites the standard and the edition answers most of a procurement review before it starts.\u003c\/p\u003e\n\u003ch2\u003eHow much insulin is left in the needle, and why does priming matter?\u003c\/h2\u003e\n\u003cp\u003eEvery pen needle has dead space between the cartridge septum and the needle tip. The manufacturer's priming step, commonly two units, fills that space so the dose dialled is the dose delivered. Skipping the prime under-delivers the first dose from a new needle; priming more than the instruction wastes insulin across a box of 100 and, in a facility, across a year. Write the priming volume into the protocol beside the product code, because it depends on the pen and needle combination rather than on the patient. Dose accuracy itself is what ISO 11608-1 is testing, and it is measured on the complete system, not on the needle alone.\u003c\/p\u003e\n\u003ch2\u003eWhat belongs in a care-home or clinic pen-needle standard?\u003c\/h2\u003e\n\u003cp\u003eOne gauge and length per pen model; compatibility verified against the pen manufacturer's own instructions rather than a generic fits-most-pens claim; single use with no recapping by hand; a sharps container within reach at every injection point; and a documented needlestick procedure. In Ontario, used needles are biomedical waste and are segregated into puncture-resistant sharps containers under Guideline C-4, The Management of Biomedical Waste in Ontario, which is the provincial document for that jurisdiction. Other provinces publish their own rules, so a policy written for sites in more than one province has to name the jurisdiction rather than treat the rule as national. Add the paper trail: lot number recorded at receipt, storage away from heat and light, and a par level that covers each pen station.\u003c\/p\u003e\n\u003ch2\u003eWhat should a buyer compare between two 32G × 4 mm boxes?\u003c\/h2\u003e\n\u003cp\u003eFive things change clinical performance, and two boxes with identical gauge and length can differ on all five: nominal outside diameter together with wall type, the pen models the hub has been validated for, the sterilisation method, the shelf life claimed for the sterile barrier, and the documentation package. Sourcing at volume is where those differences disappear into a spreadsheet, so keep a specification sheet per product code and attach the supplier's declaration to it. Our \u003ca href=\"\/fr\/products\/clinieco-blood-glucose-monitor-kit-complete-diabetes-testing-kit-with-50-test-strips\"\u003eblood glucose monitoring kit\u003c\/a\u003e and \u003ca href=\"\/fr\/products\/sterile-blood-lancets-33g-100-box\"\u003e33G blood lancets\u003c\/a\u003e follow the same documentation approach for the rest of a diabetes supply list, and the \u003ca href=\"\/fr\/products\/sharps-container-1-quart-20-case\"\u003e1-quart sharps container\u003c\/a\u003e closes the disposal loop. Volume requirements are handled through the \u003ca href=\"\/fr\/pages\/wholesale\"\u003ewholesale enquiry desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eInsulin pen needle 32G × 4 mm: specification and verification\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eAs listed on this page\u003c\/th\u003e\n\u003cth\u003eWhat to verify on the batch record\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003e32G, 0.23 mm nominal outside diameter under ISO 9626:2016\u003c\/td\u003e\n\u003ctd\u003eLot certificate stating the tube dimension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e4 mm\u003c\/td\u003e\n\u003ctd\u003eLabel and hub drawing agree with the requisition code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eRegular, thin or extra-thin wall, and the flow this gives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHub compatibility\u003c\/td\u003e\n\u003ctd\u003eStandard insulin pen platforms, verified per pen model\u003c\/td\u003e\n\u003ctd\u003eList of pen models the manufacturer tested\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDose accuracy basis\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eTest report citing ISO 11608-1 and ISO 11608-2:2022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterilisation\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eISO 11135:2014 for ethylene oxide, or the ISO 11137 series for radiation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterile barrier\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003ePackaging qualified to ISO 11607-1:2019, with shelf life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality system\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eISO 13485:2016 certificate held by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003ctd\u003eCliniEco Medical, MDEL #35334\u003c\/td\u003e\n\u003ctd\u003eLicence number on the supplier record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCliniEco Medical distributes diabetes and injection consumables in Canada under MDEL #35334. This page is a specification reference for organisations building an insulin supply list.\u003c\/p\u003e\n\u003ch2\u003eWho it is for\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLong-term care homes standardising insulin pen supplies\u003c\/li\u003e\n\u003cli\u003eDiabetes education programs and outpatient clinics\u003c\/li\u003e\n\u003cli\u003eCommunity pharmacies with injection support services\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard insulin pen platforms (verify per pen model)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecification listing — availability pending supplier documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhy do pen needle lengths come in 4, 5, 6, 8 and 12 mm?\u003c\/h3\u003e\n\u003cp\u003eLength is chosen to reach subcutaneous tissue reliably without reaching muscle. Short 4 mm needles have largely replaced longer lengths for adults because they reduce the risk of intramuscular injection.\u003c\/p\u003e\n\u003ch3\u003eShould a pen needle be reused?\u003c\/h3\u003e\n\u003cp\u003eNo. Reusing a pen needle blunts the point, increases pain and can affect dose delivery. Facilities usually issue needles per injection and drop each one into a sharps container.\u003c\/p\u003e\n\u003ch3\u003eDo pen needles fit every insulin pen?\u003c\/h3\u003e\n\u003cp\u003ePen needle platforms differ. Verify compatibility against the specific pen model you stock before setting a standard.\u003c\/p\u003e\n\u003ch3\u003eHow do I ask about volume supply?\u003c\/h3\u003e\n\u003cp\u003eSend your requirement through our B2B enquiry form.\u003c\/p\u003e\n\u003ch2\u003eRelated reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/diabetes-management-supplies-canadian-patients-glucometers-test-strips\"\u003eDiabetes management supplies: glucometers, strips and lancets\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/medical-device-licensing-in-canada-class-i-vs-class-ii-vs-class-iv-explained\"\u003eMedical device classes in Canada explained\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/university-teaching-lab-supplies-ppe-and-specimen-essentials\"\u003eClinic and teaching program supply essentials\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eListing note:\u003c\/em\u003e this page is published ahead of full catalogue onboarding so that specifications, documentation and sourcing details are available in one place. Pricing and ordering will be enabled once supplier documentation is complete. To be notified or to discuss volume requirements, use our \u003ca href=\"\/fr\/pages\/wholesale\"\u003eB2B enquiry form\u003c\/a\u003e.\u003c\/p\u003e\n","brand":"CliniEco Medical","offers":[{"title":"2-Pack","offer_id":49082000212190,"sku":"CLI-PENN-100-2PK","price":53.98,"currency_code":"CAD","in_stock":true},{"title":"Single","offer_id":49039191048414,"sku":"CLI-PENN-100","price":26.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/insulin-pen-needles-32g-4mm-100-box-1.jpg?v=1789404348"},{"product_id":"winged-infusion-set-23g-3-4-inch-50-box","title":"Winged Infusion (Butterfly) Set 23G × 3\/4\" — 50\/Box","description":"\u003cp\u003eWinged infusion sets with a 23G, 3\/4 inch needle, supplied 50 per box. The flexible wings give the fingers a stable grip during insertion, and the attached tubing allows the line to be secured while the needle stays anchored during short procedures.\u003c\/p\u003e\n\u003cp\u003eWinged sets are typically used for short-term access, single infusions, blood sampling and situations where a cannula is not warranted. Gauge and length are selected against the patient and the therapy.\u003c\/p\u003e\n\u003ch2\u003eWhat do 23G and 3\/4 inch mean at the point of insertion?\u003c\/h2\u003e\n\u003cp\u003e23G is 0.6 mm nominal outside diameter, and 3\/4 inch is 19 mm. ISO 6009:2016 sets the colour code for single-use hypodermic needles, and 23G is blue, so the hub colour is a quick cross-check that the set in the drawer matches the gauge on the box. Gauge sets flow: a 23G needle carries most routine infusions and blood sampling at a rate that suits gravity or a small pump, while 21G is faster and 25G is slower and gentler on the vein. Length decides whether the tip sits in the lumen or pushes through the wall; 19 mm is a mid-range length that suits most adult forearm and hand veins, with shorter and longer lengths reserved for small or deep veins. Needle selection is a clinical decision. What procurement controls is that the code on the box, the code in the protocol and the colour on the hub all agree.\u003c\/p\u003e\n\u003ch2\u003eWhen is a winged set the right device, and when is a cannula better?\u003c\/h2\u003e\n\u003cp\u003eA winged set suits a defined episode: one infusion, one blood draw, a short day procedure, or a patient whose veins are too fragile for a cannula. The wings give a stable grip during insertion and a flat surface to tape down, and the tubing lets the line be secured without loading the needle. A cannula is the better device when the patient needs repeated access over hours or days, because it stays in place and spares further punctures. Leaving a winged set in longer than its intended short use is where infiltration and phlebitis begin, and the failure is usually recorded against the product when it belongs to the device choice. Decide by therapy duration first, then gauge, then length.\u003c\/p\u003e\n\u003ch2\u003eWhich standards cover the needle and the connector?\u003c\/h2\u003e\n\u003cp\u003eThe needle component follows the single-use hypodermic needle requirements of ISO 7864:2016, which covers designated metric sizes from 0.18 mm to 1.2 mm; 23G at 0.6 mm falls inside that range. The tubing connector is a small-bore connector, and the current document for intravascular and hypodermic connections is ISO 80369-7:2021, second edition, which replaced the earlier Luer standard series. A set built to the older connector can be physically incompatible with a device built to ISO 80369-7, which is why connector conformance belongs on the specification sheet rather than in a footnote. Where a sharps protection feature is fitted, its performance is evaluated against ISO 23908:2011. Sterility and packaging follow the pattern used for other single-use devices: ISO 11135:2014 for ethylene oxide, the ISO 11137 series for radiation, and ISO 11607-1:2019 for the sterile barrier system.\u003c\/p\u003e\n\u003ch2\u003eHow should a winged set be secured and removed?\u003c\/h2\u003e\n\u003cp\u003eSecure the wings with tape that does not compress the hub, loop the tubing once and tape the loop so that a tug pulls the loop rather than the needle, then check blood return and flow before the infusion starts. On removal, place gauze over the site, withdraw along the line of insertion, apply pressure until bleeding stops, and put the set straight into the sharps container at the point of use rather than on a trolley. Recapping by hand is the manoeuvre that produces needlestick injuries, so the set goes in needle first. Document site, gauge, time and any reaction; a cluster of failures at one site is a technique signal, not a product signal.\u003c\/p\u003e\n\u003ch2\u003eWhat should be verified before a clinic accepts a batch?\u003c\/h2\u003e\n\u003cp\u003eCheck the label against the requisition for gauge, length and box count; check the sterile barrier for damage and confirm the expiry date; confirm the connector type; and confirm the supplier can produce a declaration of conformity citing the standards above. Keep the lot number with the batch record. A winged set is a low-cost item with a high-cost failure mode, a needlestick or an infiltrated infusion, so the batch record matters more than the unit cost. Our \u003ca href=\"\/fr\/products\/clinieco-medical-alcohol-prep-pads-70-isopropyl-200-pack\"\u003e70% isopropyl alcohol prep pads\u003c\/a\u003e and \u003ca href=\"\/fr\/products\/clinieco-biohazard-medical-waste-bags-red-30-gallon-leak-proof\"\u003ered biohazard waste bags\u003c\/a\u003e are specified the same way, and the \u003ca href=\"\/fr\/pages\/compliance-log-center\"\u003ecompliance log centre\u003c\/a\u003e holds printable forms for batch receipt and sharps replacement. Volume sourcing runs through the \u003ca href=\"\/fr\/pages\/wholesale\"\u003ewholesale enquiry desk\u003c\/a\u003e, and the wider consumable list is mapped in our guide to \u003ca href=\"\/fr\/blogs\/medical-supply-guide\/wellness-iv-infusion-clinics-consumables-for-hydration-therapy\"\u003eIV infusion clinic consumables\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge:\u003c\/strong\u003e 23G, 0.6 mm nominal outside diameter, blue hub under ISO 6009:2016\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eLength:\u003c\/strong\u003e 3\/4 inch (19 mm)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Flexible wings with attached tubing\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeedle basis:\u003c\/strong\u003e Single use\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDistribution:\u003c\/strong\u003e CliniEco Medical, MDEL #35334\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e Winged set with flexible wings and tubing\u003c\/p\u003e\u003ctable\u003e\n\u003ccaption\u003eWinged infusion set 23G × 3\/4 inch: specification and verification\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eAs listed on this page\u003c\/th\u003e\n\u003cth\u003eWhat to verify on the batch record\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003e23G, 0.6 mm nominal outside diameter, blue hub under ISO 6009:2016\u003c\/td\u003e\n\u003ctd\u003eHub colour and label agree with the requisition code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e3\/4 inch (19 mm)\u003c\/td\u003e\n\u003ctd\u003eMeasured length and label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eFlexible wings with attached tubing\u003c\/td\u003e\n\u003ctd\u003eTubing length, clamp type and whether a needle-free port is fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eConformance to ISO 80369-7:2021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeedle basis\u003c\/td\u003e\n\u003ctd\u003eSingle use\u003c\/td\u003e\n\u003ctd\u003eDeclaration citing ISO 7864:2016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterilisation\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eISO 11135:2014 for ethylene oxide, or the ISO 11137 series for radiation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterile barrier\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003ePackaging qualified to ISO 11607-1:2019, with shelf life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSharps protection\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eISO 23908:2011 test evidence if a protection feature is claimed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003ctd\u003eCliniEco Medical, MDEL #35334\u003c\/td\u003e\n\u003ctd\u003eLicence number on the supplier record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCliniEco Medical supplies infusion and injection consumables for Canadian clinics under MDEL #35334. This page is a specification reference; clinical device selection stays with the treating team.\u003c\/p\u003e\n\u003ch2\u003eWho it is for\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInfusion and outpatient treatment clinics\u003c\/li\u003e\n\u003cli\u003ePhlebotomy and blood collection services\u003c\/li\u003e\n\u003cli\u003eVaccination and travel health clinics\u003c\/li\u003e\n\u003cli\u003eHome infusion nursing programs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWinged set with flexible wings and tubing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecification listing — availability pending supplier documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhen is a winged infusion set used instead of a cannula?\u003c\/h3\u003e\n\u003cp\u003eFor short procedures, single infusions or sampling where a dwelling cannula is unnecessary. Choosing between the two is a clinical decision based on therapy duration and patient factors.\u003c\/p\u003e\n\u003ch3\u003eWhat does the gauge affect?\u003c\/h3\u003e\n\u003cp\u003eFlow rate and vessel trauma: a smaller gauge number is a larger needle, allowing faster flow but less comfortable insertion.\u003c\/p\u003e\n\u003ch3\u003eDo winged sets need sharps disposal?\u003c\/h3\u003e\n\u003cp\u003eYes. The needle is a sharp, and any set with an exposed needle goes into a sharps container immediately after use.\u003c\/p\u003e\n\u003ch3\u003eCan I source these for a home infusion program?\u003c\/h3\u003e\n\u003cp\u003eUse our B2B enquiry form with your annual volume and we will confirm documentation status.\u003c\/p\u003e\n\u003ch2\u003eRelated reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/home-infusion-nursing-disposable-supply-kits-for-each-visit\"\u003eHome infusion nursing: disposable supply kits\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/wellness-iv-infusion-clinics-consumables-for-hydration-therapy\"\u003eIV infusion clinic consumables\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/fr\/blogs\/medical-supply-guide\/b12-injection-supplies-what-clinics-need-for-vitamin-shots\"\u003eInjection supplies: what clinics need\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eListing note:\u003c\/em\u003e this page is published ahead of full catalogue onboarding so that specifications, documentation and sourcing details are available in one place. Pricing and ordering will be enabled once supplier documentation is complete. To be notified or to discuss volume requirements, use our \u003ca href=\"\/fr\/pages\/wholesale\"\u003eB2B enquiry form\u003c\/a\u003e.\u003c\/p\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":49039192096990,"sku":"CLI-BFLY-50","price":39.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/winged-infusion-set-23g-3-4-inch-50-box-1.jpg?v=1789404351"}],"url":"https:\/\/clinieco.ca\/fr\/collections\/exam-room-injection.oembed","provider":"CliniEco Medical","version":"1.0","type":"link"}