{"product_id":"winged-infusion-set-23g-3-4-inch-50-box","title":"Winged Infusion (Butterfly) Set 23G × 3\/4\" — 50\/Box","description":"\u003cp\u003eWinged infusion sets with a 23G, 3\/4 inch needle, supplied 50 per box. The flexible wings give the fingers a stable grip during insertion, and the attached tubing allows the line to be secured while the needle stays anchored during short procedures.\u003c\/p\u003e\n\u003cp\u003eWinged sets are typically used for short-term access, single infusions, blood sampling and situations where a cannula is not warranted. Gauge and length are selected against the patient and the therapy.\u003c\/p\u003e\n\u003ch2\u003eWhat do 23G and 3\/4 inch mean at the point of insertion?\u003c\/h2\u003e\n\u003cp\u003e23G is 0.6 mm nominal outside diameter, and 3\/4 inch is 19 mm. ISO 6009:2016 sets the colour code for single-use hypodermic needles, and 23G is blue, so the hub colour is a quick cross-check that the set in the drawer matches the gauge on the box. Gauge sets flow: a 23G needle carries most routine infusions and blood sampling at a rate that suits gravity or a small pump, while 21G is faster and 25G is slower and gentler on the vein. Length decides whether the tip sits in the lumen or pushes through the wall; 19 mm is a mid-range length that suits most adult forearm and hand veins, with shorter and longer lengths reserved for small or deep veins. Needle selection is a clinical decision. What procurement controls is that the code on the box, the code in the protocol and the colour on the hub all agree.\u003c\/p\u003e\n\u003ch2\u003eWhen is a winged set the right device, and when is a cannula better?\u003c\/h2\u003e\n\u003cp\u003eA winged set suits a defined episode: one infusion, one blood draw, a short day procedure, or a patient whose veins are too fragile for a cannula. The wings give a stable grip during insertion and a flat surface to tape down, and the tubing lets the line be secured without loading the needle. A cannula is the better device when the patient needs repeated access over hours or days, because it stays in place and spares further punctures. Leaving a winged set in longer than its intended short use is where infiltration and phlebitis begin, and the failure is usually recorded against the product when it belongs to the device choice. Decide by therapy duration first, then gauge, then length.\u003c\/p\u003e\n\u003ch2\u003eWhich standards cover the needle and the connector?\u003c\/h2\u003e\n\u003cp\u003eThe needle component follows the single-use hypodermic needle requirements of ISO 7864:2016, which covers designated metric sizes from 0.18 mm to 1.2 mm; 23G at 0.6 mm falls inside that range. The tubing connector is a small-bore connector, and the current document for intravascular and hypodermic connections is ISO 80369-7:2021, second edition, which replaced the earlier Luer standard series. A set built to the older connector can be physically incompatible with a device built to ISO 80369-7, which is why connector conformance belongs on the specification sheet rather than in a footnote. Where a sharps protection feature is fitted, its performance is evaluated against ISO 23908:2011. Sterility and packaging follow the pattern used for other single-use devices: ISO 11135:2014 for ethylene oxide, the ISO 11137 series for radiation, and ISO 11607-1:2019 for the sterile barrier system.\u003c\/p\u003e\n\u003ch2\u003eHow should a winged set be secured and removed?\u003c\/h2\u003e\n\u003cp\u003eSecure the wings with tape that does not compress the hub, loop the tubing once and tape the loop so that a tug pulls the loop rather than the needle, then check blood return and flow before the infusion starts. On removal, place gauze over the site, withdraw along the line of insertion, apply pressure until bleeding stops, and put the set straight into the sharps container at the point of use rather than on a trolley. Recapping by hand is the manoeuvre that produces needlestick injuries, so the set goes in needle first. Document site, gauge, time and any reaction; a cluster of failures at one site is a technique signal, not a product signal.\u003c\/p\u003e\n\u003ch2\u003eWhat should be verified before a clinic accepts a batch?\u003c\/h2\u003e\n\u003cp\u003eCheck the label against the requisition for gauge, length and box count; check the sterile barrier for damage and confirm the expiry date; confirm the connector type; and confirm the supplier can produce a declaration of conformity citing the standards above. Keep the lot number with the batch record. A winged set is a low-cost item with a high-cost failure mode, a needlestick or an infiltrated infusion, so the batch record matters more than the unit cost. Our \u003ca href=\"\/en-us\/products\/clinieco-medical-alcohol-prep-pads-70-isopropyl-200-pack\"\u003e70% isopropyl alcohol prep pads\u003c\/a\u003e and \u003ca href=\"\/en-us\/products\/clinieco-biohazard-medical-waste-bags-red-30-gallon-leak-proof\"\u003ered biohazard waste bags\u003c\/a\u003e are specified the same way, and the \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003ecompliance log centre\u003c\/a\u003e holds printable forms for batch receipt and sharps replacement. Volume sourcing runs through the \u003ca href=\"\/en-us\/pages\/wholesale\"\u003ewholesale enquiry desk\u003c\/a\u003e, and the wider consumable list is mapped in our guide to \u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/wellness-iv-infusion-clinics-consumables-for-hydration-therapy\"\u003eIV infusion clinic consumables\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge:\u003c\/strong\u003e 23G, 0.6 mm nominal outside diameter, blue hub under ISO 6009:2016\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eLength:\u003c\/strong\u003e 3\/4 inch (19 mm)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Flexible wings with attached tubing\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeedle basis:\u003c\/strong\u003e Single use\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDistribution:\u003c\/strong\u003e CliniEco Medical, MDEL #35334\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e Winged set with flexible wings and tubing\u003c\/p\u003e\u003ctable\u003e\n\u003ccaption\u003eWinged infusion set 23G × 3\/4 inch: specification and verification\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eAs listed on this page\u003c\/th\u003e\n\u003cth\u003eWhat to verify on the batch record\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003e23G, 0.6 mm nominal outside diameter, blue hub under ISO 6009:2016\u003c\/td\u003e\n\u003ctd\u003eHub colour and label agree with the requisition code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e3\/4 inch (19 mm)\u003c\/td\u003e\n\u003ctd\u003eMeasured length and label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eFlexible wings with attached tubing\u003c\/td\u003e\n\u003ctd\u003eTubing length, clamp type and whether a needle-free port is fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eConformance to ISO 80369-7:2021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeedle basis\u003c\/td\u003e\n\u003ctd\u003eSingle use\u003c\/td\u003e\n\u003ctd\u003eDeclaration citing ISO 7864:2016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterilisation\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eISO 11135:2014 for ethylene oxide, or the ISO 11137 series for radiation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterile barrier\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003ePackaging qualified to ISO 11607-1:2019, with shelf life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSharps protection\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eISO 23908:2011 test evidence if a protection feature is claimed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003ctd\u003eCliniEco Medical, MDEL #35334\u003c\/td\u003e\n\u003ctd\u003eLicence number on the supplier record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCliniEco Medical supplies infusion and injection consumables for Canadian clinics under MDEL #35334. This page is a specification reference; clinical device selection stays with the treating team.\u003c\/p\u003e\n\u003ch2\u003eWho it is for\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInfusion and outpatient treatment clinics\u003c\/li\u003e\n\u003cli\u003ePhlebotomy and blood collection services\u003c\/li\u003e\n\u003cli\u003eVaccination and travel health clinics\u003c\/li\u003e\n\u003cli\u003eHome infusion nursing programs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWinged set with flexible wings and tubing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecification listing — availability pending supplier documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhen is a winged infusion set used instead of a cannula?\u003c\/h3\u003e\n\u003cp\u003eFor short procedures, single infusions or sampling where a dwelling cannula is unnecessary. Choosing between the two is a clinical decision based on therapy duration and patient factors.\u003c\/p\u003e\n\u003ch3\u003eWhat does the gauge affect?\u003c\/h3\u003e\n\u003cp\u003eFlow rate and vessel trauma: a smaller gauge number is a larger needle, allowing faster flow but less comfortable insertion.\u003c\/p\u003e\n\u003ch3\u003eDo winged sets need sharps disposal?\u003c\/h3\u003e\n\u003cp\u003eYes. The needle is a sharp, and any set with an exposed needle goes into a sharps container immediately after use.\u003c\/p\u003e\n\u003ch3\u003eCan I source these for a home infusion program?\u003c\/h3\u003e\n\u003cp\u003eUse our B2B enquiry form with your annual volume and we will confirm documentation status.\u003c\/p\u003e\n\u003ch2\u003eRelated reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/home-infusion-nursing-disposable-supply-kits-for-each-visit\"\u003eHome infusion nursing: disposable supply kits\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/wellness-iv-infusion-clinics-consumables-for-hydration-therapy\"\u003eIV infusion clinic consumables\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/b12-injection-supplies-what-clinics-need-for-vitamin-shots\"\u003eInjection supplies: what clinics need\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eListing note:\u003c\/em\u003e this page is published ahead of full catalogue onboarding so that specifications, documentation and sourcing details are available in one place. Pricing and ordering will be enabled once supplier documentation is complete. To be notified or to discuss volume requirements, use our \u003ca href=\"\/en-us\/pages\/wholesale\"\u003eB2B enquiry form\u003c\/a\u003e.\u003c\/p\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":49039192096990,"sku":"CLI-BFLY-50","price":29.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/winged-infusion-set-23g-3-4-inch-50-box-1.jpg?v=1789404351","url":"https:\/\/clinieco.ca\/en-us\/products\/winged-infusion-set-23g-3-4-inch-50-box","provider":"CliniEco Medical","version":"1.0","type":"link"}