{"product_id":"dlab-hb120-s-led-digital-dry-bath-incubator","title":"Biological Indicator Incubator - DLAB HB105-S1 Dry Bath, 20-Well, 56-60 C, 24-Hour Readout","description":"\u003cdiv style=\"border:1px solid #d8e3e6;border-radius:10px;padding:22px 24px;margin:0 0 26px;background:#FFFFFF;\"\u003e\n\u003cp style=\"margin:0 0 8px;font-size:11px;font-weight:700;letter-spacing:.12em;text-transform:uppercase;color:#206270;\"\u003eFOR STERILITY ASSURANCE PROGRAMMES\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/dlab-hb105-s2-dry-bath-incubator-alberta-spd\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/01_hero_front_closed.jpg?v=1793235743\" alt=\"DLAB HB105-S1 Dry Bath Incubator with Lid — 20-Well, 24-Hour Biological Indicator Incubation\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 style=\"margin:0 0 12px;font-size:25px;line-height:1.28;font-weight:700;color:#12303a;\"\u003eLaboratory-grade dry-block incubation, built for the audit rather than the brochure.\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 16px;font-size:15.5px;line-height:1.65;color:#33454e;\"\u003eHolds self-contained biological indicators at 56–60 °C for the full 24-hour readout, with control accuracy of ±0.3 °C from 25 °C to 90 °C and ±0.6 °C from 90 °C to 105 °C, and no water bath to fill, change or contaminate.\u003c\/p\u003e\n\u003cdiv style=\"border-left:4px solid #1f6f5c;background:#f2f8f6;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cp style=\"margin:0;\"\u003e\u003cb\u003eLaunch offer — 50 biological indicators included\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"margin:8px 0 0;\"\u003eEvery incubator in this launch batch ships with \u003cb\u003e50 × 24-hour biological indicators\u003c\/b\u003e (the 50-pack is listed at $109.99). At two indicators per sterilisation cycle that covers 25 cycles — enough to run a full spore-testing month while the machine is new.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cul style=\"margin:0 0 18px;padding-left:20px;font-size:14.5px;line-height:1.75;color:#33454e;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e25–90 °C: ±0.3 °C, 90–105 °C: ±0.6 °C control accuracy; ±0.2 °C uniformity at 37 °C\u003c\/strong\u003e — the temperature stability a sterility assurance file depends on.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne block, 20 wells at 11 mm\u003c\/strong\u003e — sized for standard self-contained vials (8 mm body, 10 mm cap) to ISO 11138-3, not a general-purpose dry bath.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupplied with a 20-well block for 8.8 mm tubes.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecTUVus certified\u003c\/strong\u003e — TÜV Rheinland certificate CU 72205506 0001, tested to UL 61010-1 and CAN\/CSA-C22.2 No. 61010-1-12; FCC Part 15 Subpart B and ICES-001 registrations on file.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;margin:0 0 16px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:9px 10px;background:#F1F6F7;color:#12303a;border-bottom:1px solid #d8e3e6;\"\u003eWhat an auditor asks\u003c\/th\u003e\n\u003cth style=\"text-align:left;padding:9px 10px;background:#F1F6F7;color:#12303a;border-bottom:1px solid #d8e3e6;\"\u003eWhat this unit answers\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 10px;border-bottom:1px solid #eaeff1;\"\u003eWas the indicator held at the required temperature for the whole readout?\u003c\/td\u003e\n\u003ctd style=\"padding:9px 10px;border-bottom:1px solid #eaeff1;\"\u003e56–60 °C held for 24 h, within ±0.3 °C, checked against an optional PT1000 reference probe.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 10px;border-bottom:1px solid #eaeff1;\"\u003eIs the indicator itself traceable?\u003c\/td\u003e\n\u003ctd style=\"padding:9px 10px;border-bottom:1px solid #eaeff1;\"\u003eEvery BI lot ships with a certificate of analysis stating the measured spore population and D-value.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 10px;border-bottom:1px solid #eaeff1;\"\u003eCan you produce the electrical safety documentation?\u003c\/td\u003e\n\u003ctd style=\"padding:9px 10px;border-bottom:1px solid #eaeff1;\"\u003ecTUVus certificate number, standards tested to, and FCC\/ICES registrations — supplied as documents, not as claims.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 10px;\"\u003eWhere is the temperature record kept?\u003c\/td\u003e\n\u003ctd style=\"padding:9px 10px;\"\u003e\n\u003cstrong\u003eOn your own load sheet.\u003c\/strong\u003e The display holds temperature and time, and this unit does not log or export data — we would rather tell you that here than have you find it after delivery.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin:0;font-size:13px;line-height:1.65;color:#5b6b73;\"\u003eThis is a dry-block incubator, not a reader and not a data logger. The result is read visually on the indicator — purple passes, yellow fails.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin:0 0 26px;\"\u003e\n\u003cp style=\"margin:0 0 6px;font-size:15px;color:#33454e;\"\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e DLAB HB105-S1 dry bath incubator with transparent lid\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px;font-size:15px;color:#33454e;\"\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e one block, 20 wells (5 × 4), 11 mm well diameter\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px;font-size:15px;color:#33454e;\"\u003e\u003cstrong\u003eTemperature range:\u003c\/strong\u003e room temperature +5 °C to 105 °C, 0.1 °C display resolution\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px;font-size:15px;color:#33454e;\"\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e 25–90 °C: ±0.3 °C, 90–105 °C: ±0.6 °C; uniformity ±0.2 °C at 37 °C; PT1000 external probe supported\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px;font-size:15px;color:#33454e;\"\u003e\u003cstrong\u003eTimer:\u003c\/strong\u003e 0 min to 99 h 59 min\u003c\/p\u003e\n\u003cp style=\"margin:0;font-size:15px;color:#33454e;\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 3.2 kg with the block fitted\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e this page previously covered the HB120-S (no lid). It now ships as the HB105-S1 with a transparent lid — same programme, same bundle, now 20 wells. Existing orders and links are unaffected.\u003c\/em\u003e\u003c\/p\u003e\u003cdiv class=\"clini-prod-section\" style=\"background:#f0f7ff;border:2px solid #206270;border-radius:10px;padding:16px;\"\u003e \u003ch2 style=\"font-size:1.05rem;color:#206270;margin:0 0 6px;\"\u003e🎁 Buy This Incubator — Get a Free 50-Pack of BIs\u003c\/h2\u003e \u003cp style=\"margin:0;font-size:14px;color:#333;\"\u003eOrder the incubator today and we'll include \u003cstrong\u003e50 spore tests (a $109.99 value)\u003c\/strong\u003e at no charge — start your daily monitoring from day one.\u003c\/p\u003e\n\u003cp style=\"margin:12px 0 0;font-size:14px;\"\u003e\u003ca href=\"https:\/\/clinieco.ca\/cart\/49214013014238:1,48983807688926:1\" style=\"display:inline-block;background:#206270;color:#ffffff;padding:11px 20px;border-radius:6px;text-decoration:none;font-weight:600;\"\u003eAdd incubator + free 50-pack\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:8px 0 0;font-size:12.5px;color:#555;\"\u003eThis button puts both items in your cart — the 50-pack shows at $0 and you pay only for the incubator. If you prefer, add the 50-pack yourself: the discount applies automatically to one 50-pack per order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eDLAB HB105-S1 LED Dry Bath Incubator with Lid — for 24-hour biological indicator incubation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA dry-block incubator built for sterility assurance programmes: hold self-contained biological indicator vials at 56–60 °C for the 24-hour readout, with no water bath and no separate reader to buy.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransparent lid for heat preservation\u003c\/strong\u003e — your vials sit in the block for a full 24 hours, and the lid keeps both the heat in and the dust out. The lid is closed by hand.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne heating block — 20 wells (5 rows × 4 columns)\u003c\/strong\u003e, enough for a day of spore tests plus their controls in a single batch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature uniformity ±0.2 °C at 37 °C\u003c\/strong\u003e, control accuracy ±0.3 °C from 25 °C to 90 °C and ±0.6 °C from 90 °C to 105 °C. Runs from room temperature +5 °C up to 105 °C, with 0.1 °C display resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupports a PT1000 external sensor\u003c\/strong\u003e, so you can read from a reference point rather than the block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTimer, 0 min to 99 h 59 min\u003c\/strong\u003e — set it and walk away.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecTUVus certified\u003c\/strong\u003e — cTUVus, TÜV Rheinland certificate CU 72205506 0001, tested to UL 61010-1 and CAN\/CSA-C22.2 No. 61010-1-12; FCC Part 15 Subpart B (registration AK 50495998 0001) and ICES-001:2006 (registration AK 50496013 0001). 115 V AC, 50\/60 Hz power supply (North American plug).\u003c\/li\u003e\n\u003cli\u003eOverheating protection. Manufacturer: DLAB Scientific Co., Ltd., Beijing. Sold in Canada by CliniEco Medical, Health Canada establishment licence MDEL #35334.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor biological indicator incubation\u003c\/strong\u003e\u003cbr\u003e\nIntended for steam-cycle biological indicators — Geobacillus stearothermophilus self-contained vials to ISO 11138-3 — incubated between 55 and 60 °C with a 24-hour readout. The 11 mm wells take vials with a body diameter of 8 mm and a cap diameter of 10 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat this unit does, and does not, do\u003c\/strong\u003e\u003cbr\u003e\nThe result is read visually on the indicator itself: the medium stays purple when the cycle passes and turns yellow on a failure. This unit is an incubator, not a reader — it does not interpret fluorescent or rapid-readout indicators, which require a fluorescence reader. It does not record or export data; temperature and time are shown on the LED display and are kept on your daily record sheet.\u003c\/p\u003e\n\u003ch2\u003eWhat does spore testing cost per year with this incubator?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003cth\u003eCost per test\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHB105-S1 dry bath incubator with lid (one-time)\u003c\/td\u003e\n\u003ctd\u003e$499.00\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003e24-hour self-contained biological indicator, 25-pack\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e$69.99\u003c\/td\u003e\n\u003ctd\u003e$2.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDaily monitoring on one sterilizer, 250 tests a year\u003c\/td\u003e\n\u003ctd\u003e$699.90 in indicators\u003c\/td\u003e\n\u003ctd\u003e$2.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFirst-year total for a single sterilizer is $499.00 for the incubator plus $699.90 in indicators, or $1,198.90; with the launch offer at the top of this page the first 50 indicators are included at no charge, which brings the first-year figure to $1,088.91. From the second year the annual cost is the indicators alone. The 250-test line assumes one test on each day the sterilizer is used, five days a week; a site running two sterilizers doubles the indicator line.\u003c\/p\u003e\n\n\u003ch2\u003eWhich biological indicators work in this incubator?\u003c\/h2\u003e\n\u003cp\u003eThis is a dry bath held at 56 to 60 °C for the 24-hour readout, which is the incubation condition self-contained \u003cem\u003eGeobacillus stearothermophilus\u003c\/em\u003e indicators to ISO 11138-3 are designed for. The 11 mm wells take vials with a body diameter of 8 mm and a cap diameter of 10 mm. Rapid-readout indicators — 1-hour, 3-hour and 20-minute fluorescence — are not incubated here; they need their own reader.\u003c\/p\u003e\n\n\u003ch2\u003eHow many indicators fit in one run, and is that enough?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating blocks\u003c\/td\u003e\n\u003ctd\u003eOne block, 20 wells (5 rows × 4 columns)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e11 mm diameter, for 8 mm vial body \/ 10 mm cap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003eRoom temperature +5 °C to 105 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl accuracy\u003c\/td\u003e\n\u003ctd\u003e25–90 °C: ±0.3 °C; 90–105 °C: ±0.6 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUniformity\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C at 37 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer\u003c\/td\u003e\n\u003ctd\u003e0 min to 99 h 59 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal sensor\u003c\/td\u003e\n\u003ctd\u003ePT1000 supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eAC 115 V, 50\/60 Hz, North American plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLid\u003c\/td\u003e\n\u003ctd\u003eTransparent, hand-closed — keeps heat in and dust out during the run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003ecTUVus, TÜV Rheinland certificate CU 72205506 0001 (UL 61010-1, CAN\/CSA-C22.2 No. 61010-1-12); FCC Part 15 Subpart B, registration AK 50495998 0001; ICES-001:2006, registration AK 50496013 0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTwenty wells take twenty vials in one batch: ten spore tests, each paired with its matching control — the pattern daily monitoring follows on a single sterilizer. A 25-pack therefore runs as two batches, which is why the launch offer ships the 50-pack with this unit. That matters because a 24-hour readout means the block is occupied for the whole day: if the batch does not fit, the results split across two days.\u003c\/p\u003e\n\n\u003ch2\u003eDo I need a reader with this incubator?\u003c\/h2\u003e\n\u003cp\u003eNo. A 24-hour colour-change indicator is read by eye — the medium stays purple when the cycle passes and turns yellow on a failure — and recorded on your daily log. A fluorescence reader is only needed for 1-hour, 3-hour and 20-minute rapid indicators, where the result is a machine reading. This unit does not record or export data; temperature and time are shown on the LED display and copied onto your record sheet — a printable daily log is available at \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003ethe compliance log centre\u003c\/a\u003e. For questions about which monitoring interval applies to your own sterilizers, \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003esend the question to a sterilization compliance specialist\u003c\/a\u003e and you get a written answer that cites the standard behind it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDocumentation\u003c\/strong\u003e\u003cbr\u003e\nEnglish user manual included, French on request. Manufacturer warranty terms are available on request. Not for household use.\u003c\/p\u003e\n\u003ch2\u003eChoosing the right option for your clinic\u003c\/h2\u003e\n\u003cp\u003eBefore you order, the decisions that actually change the result are well count, temperature band, calibration evidence, and what an incubator you cannot defend costs at audit. The full buyer's guide covers them step by step: \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/how-to-choose-biological-indicator-incubator-canadian-clinic\"\u003eHow to Choose a Biological Indicator Incubator for a Canadian Clinic\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eRelated supplies for the same workflow\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003e24-hour self-contained biological indicators, 25 per pack\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-rapid-reader-4-well-fluorescence-biological-indicator-reader\"\u003e4-well fluorescence biological indicator reader\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-24-hour-biological-indicator-incubator-precision-dry-block-15-wells\"\u003eCliniEco 24-hour dry block incubator, 15-well\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/p25_01_main_1500_E2.jpg?v=1793459608\" alt=\"24-hour self-contained biological indicators\" loading=\"lazy\" width=\"480\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/sterilizer-testing-frequency-us-vs-canada-biological-indicator-ordering\"\u003eHow Often Must US vs Canadian Clinics Run Sterilizer Testing? Which Biological Indicator Pack to Order\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/how-often-us-vs-canadian-clinics-sterilizer-testing-incubator-guide\"\u003eHow Often Must US vs Canadian Clinics Run Sterilizer Testing? 24-Hour Biological Indicator Incubator Ordering \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/how-do-i-know-if-my-autoclave-is-working-properly\"\u003eHow do I know if my autoclave is working properly?\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow does a 24-hour incubation run actually work, hour by hour?\u003c\/h2\u003e\n\u003cp\u003eThe run is shorter to describe than it is to get wrong. After the sterilization cycle, each indicator is activated according to the manufacturer's instructions for use, labelled so it can be matched to the sterilizer and the load, stood in the block, and left at incubation temperature for the full readout period. With a 24-hour self-contained indicator that means the block is occupied for a working day, the lid stays on, and the result is read the following day against the unexposed control that was incubated alongside it.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eStage\u003c\/th\u003e\n\u003cth\u003eWhat happens at the unit\u003c\/th\u003e\n\u003cth\u003eWhat is written down\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad\u003c\/td\u003e\n\u003ctd\u003eVials stand in the 20 wells (5 rows × 4 columns, Ø 11 mm), which take an 8 mm vial body with a 10 mm cap\u003c\/td\u003e\n\u003ctd\u003eDate, sterilizer, cycle type and lot code against each position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet the temperature\u003c\/td\u003e\n\u003ctd\u003eThe block is set into the 56–60 °C band for steam indicators; the display reads to 0.1 °C\u003c\/td\u003e\n\u003ctd\u003eSet point, and whether a reference probe was used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRun\u003c\/td\u003e\n\u003ctd\u003eThe timer counts through the readout period — 0 min to 99 h 59 min on this unit — with the transparent lid closed by hand\u003c\/td\u003e\n\u003ctd\u003eStart time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRead\u003c\/td\u003e\n\u003ctd\u003ePurple means no growth and the load releases; yellow means spores survived\u003c\/td\u003e\n\u003ctd\u003eResult, read time, and the control's result\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn a fail\u003c\/td\u003e\n\u003ctd\u003eThe load goes back for re-sterilization and the sterilizer is re-tested before anything in it is released\u003c\/td\u003e\n\u003ctd\u003eThe fail itself, the corrective step and the re-test result\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTwo things about that sequence are worth stating plainly, because they are where an inspection usually lands. The lid is closed by hand and there is nothing that closes it for you, so a run started in a hurry with the lid left off is a run at the wrong temperature. And the block only holds, it does not read: the colour change on the vial is the result, and this unit is not a reader.\u003c\/p\u003e\n\n\u003ch2\u003eHow many vials fit in one run, and when does a result slide to the next day?\u003c\/h2\u003e\n\u003cp\u003eTwenty wells hold twenty vials, and a monitoring day needs two vials per sterilizer — the test and its matching control. That is ten sterilizer-days per batch, which is exactly one sterilizer over ten test days, or two sterilizers over five. A 25-pack therefore takes two batches, because twenty vials fit and five are left over; that leftover is why the 50-pack is the size that ships with this unit rather than the 25.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSterilizers tested per day\u003c\/th\u003e\n\u003cth\u003eVials needed per day\u003c\/th\u003e\n\u003cth\u003eDays one 20-well batch covers\u003c\/th\u003e\n\u003cth\u003eWhat that means for ordering\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e10 test days\u003c\/td\u003e\n\u003ctd\u003eA 25-pack runs as two batches; a 50-pack as five\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e5 test days\u003c\/td\u003e\n\u003ctd\u003eOne week of daily monitoring per batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3 test days\u003c\/td\u003e\n\u003ctd\u003ePlan the week around the block rather than the block around the week\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4 and up\u003c\/td\u003e\n\u003ctd\u003e8 and up\u003c\/td\u003e\n\u003ctd\u003e2 test days or fewer\u003c\/td\u003e\n\u003ctd\u003eTime to ask whether one block is the right equipment for the room\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWhy this matters more than it sounds: a 24-hour readout occupies the well for the whole period, so a batch that does not fit does not run late — it splits across two days, and the second day's results are a day behind. A room that tests two sterilizers daily should be loading the whole week's worth of work into one batch, not discovering on Thursday that the block has been full since Tuesday.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does the certification cover, and what goes in the file?\u003c\/h2\u003e\n\u003cp\u003eThe electrical documentation is the part of a benchtop incubator that auditors ask for and that most listings do not print. This unit carries cTUVus certification from TÜV Rheinland under certificate CU 72205506 0001, tested to UL 61010-1 and CAN\/CSA-C22.2 No. 61010-1-12, with the EMC registrations below held on file.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003cth\u003eWhat it covers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical safety certification\u003c\/td\u003e\n\u003ctd\u003ecTUVus, TÜV Rheinland certificate CU 72205506 0001\u003c\/td\u003e\n\u003ctd\u003eUL 61010-1 and CAN\/CSA-C22.2 No. 61010-1-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC, United States\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Subpart B, registration AK 50495998 0001\u003c\/td\u003e\n\u003ctd\u003eEmissions compliance for the US market\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC, Canada\u003c\/td\u003e\n\u003ctd\u003eICES-001:2006, registration AK 50496013 0001\u003c\/td\u003e\n\u003ctd\u003eEmissions compliance for the Canadian market\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e115 V AC, 50\/60 Hz, North American plug\u003c\/td\u003e\n\u003ctd\u003eThe building supply the unit is rated for\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eDLAB Scientific Co., Ltd., Beijing\u003c\/td\u003e\n\u003ctd\u003eWho built the unit and issues the manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImporter\u003c\/td\u003e\n\u003ctd\u003eCliniEco Medical, Health Canada MDEL #35334\u003c\/td\u003e\n\u003ctd\u003eWho is accountable for it in Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAsk for the certificate and the two registration numbers as documents, not as claims on a listing page — that is the whole point of printing the numbers. The instruction manual ships in English with the unit and in French on request, and the manufacturer's warranty terms are available on request.\u003c\/p\u003e\n\n\u003ch2\u003eHow is the incubation temperature set, and how is it checked?\u003c\/h2\u003e\n\u003cp\u003eThe block runs from room temperature +5 °C up to 105 °C, and steam biological indicators are incubated in the 56–60 °C band, so the set point is a band rather than a single number. The display reads to 0.1 °C and the timer runs to 99 h 59 min, which covers a 24-hour readout with room to spare. The unit also supports a PT1000 external probe, which is the useful part: it lets a practice read from a reference point in the block rather than trusting the set point alone.\u003c\/p\u003e\n\u003cp\u003eWhat the unit does not do is record. There is no logging and no export — the numbers on the LED display are copied onto your own record sheet, which is why the printable logs at the compliance log centre are worth printing before the incubator arrives rather than after. A practice that wants a temperature trace has to keep one; this unit holds the temperature, it does not document it.\u003c\/p\u003e\n\n\u003ch2\u003eWhat this incubator is not\u003c\/h2\u003e\n\u003cp\u003eFour exclusions, each of which sends a buyer somewhere else, and it is quicker to say them here than to discover them after delivery. It is not a reader: 1-hour, 3-hour and 20-minute fluorescence indicators need their own reader and are not incubated here. It is not a data logger. It is not a water bath, so there is nothing to fill, change or spill, and nothing that grows in a tank between runs. And it is not a general-purpose dry bath — the block is drilled for standard self-contained vials to ISO 11138-3, not for tubes of arbitrary size.\u003c\/p\u003e\n\u003cp\u003eThe direct consequence of the first exclusion is the one to plan for: a practice that wants same-shift release needs a rapid-readout system, and a practice that tests daily and releases the next morning is the one this unit is built for.\u003c\/p\u003e\n\n\u003ch2\u003eWho this incubator suits, and who it does not\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSetting\u003c\/th\u003e\n\u003cth\u003eFits?\u003c\/th\u003e\n\u003cth\u003eReason\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolo or small practice, one sterilizer, daily testing\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eTwo vials a day occupies a tenth of the block; the 50-pack ships with the unit for exactly this rhythm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePractice with two sterilizers tested daily\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eFour vials a day, twenty wells, a week of work per batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-site group standardising across rooms\u003c\/td\u003e\n\u003ctd\u003eYes, one per room\u003c\/td\u003e\n\u003ctd\u003eThe unit is a small benchtop box; a shared incubator between rooms means carrying activated vials down a corridor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinic using rapid-readout fluorescence indicators\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eThose need a reader; this block does not interpret them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinic wanting an automated temperature record\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo logging or export — the record is written by hand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWhere it does fit, the first-year cost is one capital line and one consumable line: the incubator once, the indicators every time the box runs out. Spread across a daily-monitoring year the unit is the smaller of the two numbers, which is worth knowing before a practice decides to keep spore-testing by hand and ordering the box that actually documents it later.\u003c\/p\u003e\n\n\u003ch2\u003eWhere should the incubator sit in the reprocessing room?\u003c\/h2\u003e\n\u003cp\u003eIt is a benchtop box of 3.2 kg with the block fitted, and it runs from a standard 115 V AC outlet with a North American plug, so the siting question is about workflow rather than services. Put it where the indicators are activated and where the record is written. A block that lives at the far end of the room from the log sheet is a block whose results get copied down from memory at four o'clock, which is the failure mode a paper record is supposed to prevent.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSiting question\u003c\/th\u003e\n\u003cth\u003eWhat the unit needs\u003c\/th\u003e\n\u003cth\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBench space\u003c\/td\u003e\n\u003ctd\u003eRoom for the footprint plus the hand-closed lid to open and close\u003c\/td\u003e\n\u003ctd\u003eThe lid is operated by hand at the start and end of every run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e115 V AC, 50\/60 Hz, North American plug\u003c\/td\u003e\n\u003ctd\u003eThe unit is supplied as the North American build\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhere the log is kept\u003c\/td\u003e\n\u003ctd\u003eBeside the block, not across the room\u003c\/td\u003e\n\u003ctd\u003eResult, time and lot code are copied off the vials and the display at the end of the run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhere vials are activated\u003c\/td\u003e\n\u003ctd\u003eThe same bench, or the bench next to it\u003c\/td\u003e\n\u003ctd\u003eActivated vials go straight into the block rather than travelling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraffic\u003c\/td\u003e\n\u003ctd\u003eOff the walkway between the sink and the autoclave\u003c\/td\u003e\n\u003ctd\u003eAn incubator is bumped once a month in a busy room, and a knocked block is a lost batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThere is nothing to plumb and nothing to drain, which is the practical advantage of a dry block over a water bath: a bench, a socket and a log sheet are the whole installation.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to check on arrival\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat good looks like\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel and nameplate\u003c\/td\u003e\n\u003ctd\u003eHB105-S1 with the transparent lid, matching the certificate number quoted on this page\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlock\u003c\/td\u003e\n\u003ctd\u003eOne block, 20 wells in 5 rows of 4, Ø 11 mm, seated squarely in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLid\u003c\/td\u003e\n\u003ctd\u003eCloses by hand, sits flush, and does not foul the vial caps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirst run\u003c\/td\u003e\n\u003ctd\u003eSet the block into the 56–60 °C band and confirm the display holds it before the first real batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocuments\u003c\/td\u003e\n\u003ctd\u003eManual in the carton, certificate and EMC registrations on request, importer details on the label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"DLAB","offers":[{"title":"Default Title","offer_id":49214013014238,"sku":"DLAB-HB105-S1","price":474.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/HB105-S1-HERO-promo50-20261110_e2b9bf73-4800-4710-977d-b4bb450cb83c_e0c85514-64d8-48e1-87c7-783f4b7d0fbb.jpg?v=1794342653","url":"https:\/\/clinieco.ca\/en-us\/products\/dlab-hb120-s-led-digital-dry-bath-incubator","provider":"CliniEco Medical","version":"1.0","type":"link"}