{"product_id":"clinieco-ultrasonic-cleaner-cd4862-6l-dental","title":"CliniEco Dental Ultrasonic Cleaner — CD-4862, 6 L with 5-Preset Heating and Timer","description":"\u003cp\u003e\u003cstrong\u003eQuick answer:\u003c\/strong\u003e A 6 L tank — cassette size — with five fixed temperature presets between 40 °C and 60 °C and a full-range 1 to 30 minute timer, so the cycle is written down rather than guessed.\u003c\/p\u003e\n\n\u003cp\u003eThe 6 L class is the size at which a standard dental instrument cassette fits in one cycle, and this is the unit in the range that treats temperature as a fixed setting rather than a dial. Five presets — 40, 45, 50, 55 and 60 °C — plus a timer that runs the whole 1 to 30 minute range, and a three-colour LED display that shows the set-point while the cycle runs. Tank opening is 32.5 × 20.4 × 9.9 cm, which takes an instrument up to 34 cm long.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eScope of use.\u003c\/strong\u003e This is a cleaning device. It removes soil — cement residue, polishing paste, dried blood in hinges and threads — as a step in instrument reprocessing. It makes no microbicidal claim, and it does not replace any later step in the workflow set out in the instrument manufacturer’s instructions for use. The \u003ca href=\"https:\/\/www.canada.ca\/en\/health-canada\/services\/drugs-health-products\/medical-devices\/application-information\/guidance-documents\/guidance-document-information-manufacturers-sterilization-reusable-medical-devices.html\"\u003eHealth Canada guidance on reprocessing information\u003c\/a\u003e is why the instrument manufacturer’s instructions — not the cleaner’s specification sheet — decide what happens to a given instrument after it comes out of the tank.\u003c\/p\u003e\n\n\u003ch2\u003eWhat are the CD-4862 specifications?\u003c\/h2\u003e\n\n\u003cp\u003eThe presets are the operational difference between this unit and a tank with a rotary thermostat: the number you set is the number you record.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eTank capacity:\u003c\/strong\u003e 6 L (6,000 ml) stainless steel\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTank opening:\u003c\/strong\u003e 32.5 × 20.4 × 9.9 cm — accepts instruments up to 34 cm long\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e 35 kHz, two industrial-grade transducers\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e 260 W rated, AC 100–120 V, 60 Hz, North American plug\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTimer:\u003c\/strong\u003e 1 to 30 minutes, full range, with three-colour LED display\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHeating:\u003c\/strong\u003e Five presets: 40 \/ 45 \/ 50 \/ 55 \/ 60 °C, with the °F equivalent shown\u003c\/p\u003e\u003ctable\u003e\n\u003ccaption\u003eCD-4862 — 6 L benchtop ultrasonic cleaner, specifications as supplied\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eField\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTank capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L (6,000 ml) stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTank dimensions\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e32.5 × 20.4 × 9.9 cm (length × width × depth), SUS304 stainless steel tank\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTank opening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32.5 × 20.4 × 9.9 cm — accepts instruments up to 34 cm long\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 kHz, two industrial-grade transducers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e260 W rated, AC 100–120 V, 60 Hz, North American plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTimer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 30 minutes, full range, with three-colour LED display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFive presets: 40 \/ 45 \/ 50 \/ 55 \/ 60 °C, with the °F equivalent shown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual heating protection, moisture-resistant PCB, detachable power cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ecETL — Intertek report 210716104GZU-001, to UL 73 and CSA C22.2 No. 68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnit, one-year manufacturer warranty; stainless basket available as an accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eList price\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAD $649.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eDoes this unit log cleaning cycles?\u003c\/h2\u003e\n\u003cp\u003eNo. The CD-4862 has no internal data logger and cannot export cycle data to a USB drive or a CSV file. If your reprocessing protocol requires machine-generated cycle records, choose a unit built for that purpose — this model is not one.\u003c\/p\u003e\n\u003cp\u003eWhat the CD-4862 gives you instead is everything needed to keep a defensible manual record: a front-panel timer that counts the cycle, a temperature set-point you can read and write down, and a drain valve so the solution-change date is unambiguous. Under CSA Z314:23 the documentation obligation sits inside your reprocessing quality system rather than inside the appliance, so a signed paper log is not a lesser record — it is the record the standard asks for.\u003c\/p\u003e\n\u003cp\u003eFive fields per cycle is enough: date, operator, temperature set-point, cycle length, and the date the solution was last changed. One line, end of shift.\u003c\/p\u003e\n\u003ch2\u003eWhich tank size in the range fits your room?\u003c\/h2\u003e\n\n\u003cp\u003eTwo 6 L units sit in this range and they are not the same product. This one fixes the temperature in 5 °C steps and runs 35 kHz; the CS6.2 runs 32 and 48 kHz on one generator. If your protocol names a temperature, the preset ladder is the easier machine to audit.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eModel range as listed — tank, frequency and the load each size is built for\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eTank\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eBuilt for\u003c\/th\u003e\n\u003cth\u003eList price (CAD)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-4l-cs4-0-benchtop-dual-frequency\"\u003eCS4.0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 L\u003c\/td\u003e\n\u003ctd\u003e32 \/ 48 kHz\u003c\/td\u003e\n\u003ctd\u003eSingle chair, loose instruments\u003c\/td\u003e\n\u003ctd\u003e$449.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCD-4862\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eFull cassette, five temperature presets\u003c\/td\u003e\n\u003ctd\u003e$649.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003eCS6.2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L\u003c\/td\u003e\n\u003ctd\u003e32 \/ 48 kHz\u003c\/td\u003e\n\u003ctd\u003eFull cassette, dual frequency\u003c\/td\u003e\n\u003ctd\u003e$699.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-cd4875-7-5l-dental\"\u003eCD-4875\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eLarger trays, five temperature presets\u003c\/td\u003e\n\u003ctd\u003e$849.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-8l-cs8-0-benchtop\"\u003eCS8.0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e8 L\u003c\/td\u003e\n\u003ctd\u003e49 kHz\u003c\/td\u003e\n\u003ctd\u003eTwo chairs into one cycle\u003c\/td\u003e\n\u003ctd\u003e$999.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-20l-cs20-bench\"\u003eCS20\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eSeveral chairs or batch work\u003c\/td\u003e\n\u003ctd\u003e$1,199.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eThe length limit is worth measuring before you buy. A 34 cm working length covers most hand instruments and many extraction forceps; anything longer belongs in a 20 L tank where the chamber is 42 cm long.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/599bf33f4da20fb38d1771bb70a76d19.png?v=1792815581\" alt=\"Six litre benchtop ultrasonic cleaner, straight-on view of the unit with the lid closed\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch2\u003eHow do you run a repeatable cleaning cycle on the CD-4862?\u003c\/h2\u003e\n\n\u003cp\u003eThis unit is built for the practice whose protocol already names a temperature. The presets exist so the number in the protocol and the number on the panel are the same number.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eCycle set-up step by step\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStep\u003c\/th\u003e\n\u003cth\u003eSetting\u003c\/th\u003e\n\u003cth\u003eWhy it matters\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1. Fill\u003c\/td\u003e\n\u003ctd\u003eSolution at the label dilution, to the working level in the tank\u003c\/td\u003e\n\u003ctd\u003eThe same fill level every day keeps the load behaviour constant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2. Preset\u003c\/td\u003e\n\u003ctd\u003eChoose 40, 45, 50, 55 or 60 °C to match the solution label\u003c\/td\u003e\n\u003ctd\u003eA fixed preset is a recordable number; a thermostat dial is an estimate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3. Load\u003c\/td\u003e\n\u003ctd\u003eInstruments in a basket or tray, joints open, not stacked\u003c\/td\u003e\n\u003ctd\u003eCavitation does not reach shielded surfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4. Time\u003c\/td\u003e\n\u003ctd\u003e1 to 30 minutes — set the interval your protocol names\u003c\/td\u003e\n\u003ctd\u003eThe full range means the timer is not the constraint on the protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5. Drain, dry, record\u003c\/td\u003e\n\u003ctd\u003eDrain through the valve, dry, then log temperature, time and operator\u003c\/td\u003e\n\u003ctd\u003eThe three data points an inspector reconstructs a cycle from\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eKeep the solution inside the temperature window printed on its label rather than at the highest preset. Hotter is not cleaner: above the solution manufacturer's range, the enzymes lose activity and the tank starts to leave a film on stainless.\u003c\/p\u003e\n\n\u003cp\u003eWhat an infection-control inspection asks for is the record, not the machine. Ontario’s provincial reprocessing guidance asks for \u003cem\u003edocumentation and maintenance of records for each component of the cleaning, disinfection and\/or sterilization process\u003c\/em\u003e, based on the manufacturer’s recommendations, and repeats that records \u003cem\u003emust be retained according to the facility’s policy\u003c\/em\u003e (\u003ca href=\"https:\/\/www.publichealthontario.ca\/-\/media\/Documents\/B\/2013\/bp-cleaning-disinfection-sterilization-hcs.pdf?rev=074097c0ef2343379b7bb17d97b75526\u0026amp;sc_lang=en\"\u003ePublic Health Ontario, “Best Practices for Cleaning, Disinfection and Sterilization of Medical Equipment\/Devices In All Health Care Settings”, 3rd edition, checked 2026-11-07\u003c\/a\u003e). A unit with a drain valve, a visible timer and a stable temperature set-point is what makes that record short enough to write at the end of a shift.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does the cETL mark cover, and what does it not?\u003c\/h2\u003e\n\n\u003cp\u003eThis unit is covered by a separate Intertek report from the CS range — 210716104GZU-001 rather than 220112139GZU-001 — which is worth knowing when a technician asks which family the certificate names. The mark on the unit is an ETL mark issued by Intertek, tested against \u003ca href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL73\"\u003eUL 73\u003c\/a\u003e and \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/C22.2%20NO.%2068-18\/\"\u003eCSA C22.2 No. 68\u003c\/a\u003e. It is an electrical safety certificate. It is not a UL listing and it is not CSA certification, and it says nothing about how well the tank cleans. Canadian reprocessing practice sits on a separate standard, \u003ca href=\"https:\/\/store.csastandards.org\/store\/product\/2430344\/\"\u003eCSA Z314:23\u003c\/a\u003e, whose scope puts documentation inside the reprocessing quality system rather than inside the appliance.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eWhat the electrical certificate covers, and what it does not\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCovers\u003c\/th\u003e\n\u003cth\u003eDoes not cover\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical safety of the appliance, assessed to UL 73 and CSA C22.2 No. 68\u003c\/td\u003e\n\u003ctd\u003eCleaning performance on your instruments, on your water hardness, or at your solution concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe specific unit family named on Intertek report 210716104GZU-001\u003c\/td\u003e\n\u003ctd\u003eThe condition of an individual unit after a drop, a repair, or a modification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance of the supply, plug and cord assembly for the North American market\u003c\/td\u003e\n\u003ctd\u003eAny clinical outcome, or any claim that the unit removes or inactivates micro-organisms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe identity of the certificate holder and the factory it was issued to\u003c\/td\u003e\n\u003ctd\u003eYour own reprocessing records, which are yours to keep and produce\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\n\u003ch2\u003eWhat is in the box, and what should be ordered with it?\u003c\/h2\u003e\n\n\u003cp\u003eOne cleaner, 6 L, 110 V with a North American plug and the manufacturer warranty. The stainless basket is an accessory. The power cord detaches, which matters in a room where the bench is wiped down between sessions.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003eMulti-enzyme ultrasonic cleaning solution\u003c\/a\u003e is what goes in the tank, sold as a 1 L bottle or a 5 L pail and diluted 1:400 to 1:600. The \u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003e6 L CS6.2\u003c\/a\u003e is the unit to look at if your load grows into full cassettes. Read \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/choosing-ultrasonic-cleaner-tank-size-canadian-dental-clinic\"\u003ehow to choose a tank size\u003c\/a\u003e and \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/what-should-a-canadian-clinic-record-for-ultrasonic-cleaning-log-fields-and-retention\"\u003ewhat to record on the cleaning log\u003c\/a\u003e before you commit to a size.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does one tank fill cost in cleaning solution?\u003c\/h2\u003e\n\u003cp\u003eThe 6 L tank is the cassette size, and it is also the worked example on the solution page: a 6 L fill needs 15 mL of concentrate at 1:400 and 10 mL at 1:600. Those two figures are the whole chemistry cost of a cassette cycle — what is left for you to check is the pack price on the day you order, because that is the only variable that moves.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCD-4862 — concentrate per full tank and pack yield at the two label dilutions\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eDilution on the label\u003c\/th\u003e\n\u003cth\u003eConcentrate per full tank (6 L)\u003c\/th\u003e\n\u003cth\u003eFills from a 1 L bottle\u003c\/th\u003e\n\u003cth\u003eFills from a 5 L pail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1:400 — heavier soil\u003c\/td\u003e\n\u003ctd\u003e≈ 15 mL\u003c\/td\u003e\n\u003ctd\u003e66 fills\u003c\/td\u003e\n\u003ctd\u003e333 fills\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1:600 — light soil\u003c\/td\u003e\n\u003ctd\u003e≈ 10 mL\u003c\/td\u003e\n\u003ctd\u003e100 fills\u003c\/td\u003e\n\u003ctd\u003e500 fills\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCost per fill = the current pack price divided by the fills in that pack. Both halves of that sum move — the pack price with the market, the fills with how full you run the tank — which is why the page gives the arithmetic instead of a per-cycle figure. If your protocol changes the bath once per working day, five days a week, 66 fills is roughly 13 working weeks from one bottle.\u003c\/p\u003e\n\n\u003ch2\u003eWhich cleaning solution goes in this tank, and when should it be changed?\u003c\/h2\u003e\n\u003cp\u003eUse the \u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003emulti-enzyme ultrasonic cleaning concentrate\u003c\/a\u003e — 1 L bottle or 5 L pail — diluted 1:400 to 1:600. It is low-foam by design, so the cavitation field does the work instead of a head of bubbles, and it is freely rinsable on stainless, anodised aluminium and plated instruments. The label window is 20–50 °C for 2 to 10 minutes; keep the bath inside it rather than at the highest preset this unit offers.\u003c\/p\u003e\n\u003cp\u003eChange the bath on the schedule your label and protocol set, and log the change with the same five fields as the cycle: date, dilution, fill level, temperature, initials. The drain valve makes the job unambiguous, and the record is the part an inspector reads — Ontario reprocessing guidance asks for \u003cem\u003edocumentation and maintenance of records for each component of the cleaning, disinfection and\/or sterilization process\u003c\/em\u003e (\u003ca href=\"https:\/\/www.publichealthontario.ca\/-\/media\/Documents\/B\/2013\/bp-cleaning-disinfection-sterilization-hcs.pdf?rev=074097c0ef2343379b7bb17d97b75526\u0026amp;sc_lang=en\"\u003ePublic Health Ontario provincial reprocessing guidance, 3rd edition, checked 2026-11-07\u003c\/a\u003e).\u003c\/p\u003e\n\n\u003ch2\u003eWhat is the lead time, and what maintenance does the unit need?\u003c\/h2\u003e\n\u003cp\u003eThis unit is built to order — allow 3–4 weeks, and we confirm the dispatch date before it ships. The manufacturer warranty runs one year and is supported in Canada. CliniEco Medical holds Health Canada establishment licence (MDEL) #35334 — importer and distributor — which is separate from the warranty terms. What the unit asks of you in return is short, and mostly about the bath rather than the electronics.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCD-4862 — routine maintenance and why each item is on the list\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTask\u003c\/th\u003e\n\u003cth\u003eInterval\u003c\/th\u003e\n\u003cth\u003eWhy it matters\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain and refill\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAt the interval the solution label and your protocol set\u003c\/td\u003e\n\u003ctd\u003eSoil load accumulates in the bath whatever the instruments look like when they come out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRun a fresh fill before the first load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery refill\u003c\/td\u003e\n\u003ctd\u003eDissolved air in new solution damps cavitation, and the bath should be at working temperature before an instrument goes in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRinse tank and basket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery change\u003c\/td\u003e\n\u003ctd\u003eResidue left on stainless carries soil into the next fill and films the tank over time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWipe lid and check cord, plug and drain valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003ctd\u003eThe three parts a drop or a wipe-down damages first\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeep the level above the working minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery cycle\u003c\/td\u003e\n\u003ctd\u003eRunning dry is the one failure mode that ends a tank’s service life early\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eA presets-based unit invites a habit worth avoiding: turning the temperature up when a load comes out dull. Above the solution label’s range the enzymes lose activity and the tank starts to film over — the fix is a fresh fill at the correct dilution, not a hotter one.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRelated reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/choosing-ultrasonic-cleaner-tank-size-canadian-dental-clinic\"\u003eChoosing an Ultrasonic Cleaner Tank Size for a Canadian Dental Clinic\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/what-should-a-canadian-clinic-record-for-ultrasonic-cleaning-log-fields-and-retention\"\u003eWhat Should a Canadian Clinic Record for Ultrasonic Cleaning?\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/enzymatic-cleaner-cost-per-litre-canada-dilution-economics\"\u003eEnzymatic Cleaner Cost per Litre in Canada: Dilution Economics\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCliniEco Medical is a licensed medical device establishment (MDEL #35334). We are the Canadian importer of record for this unit: duties and brokerage are handled on our side, and you receive it from our Toronto warehouse with a one-year manufacturer warranty supported in Canada. Questions on which size fits your room go to our \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003esterilization desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt to order.\u003c\/strong\u003e Allow 3–4 weeks — we confirm the dispatch date before the unit ships.\u003c\/p\u003e","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":49376920142046,"sku":"CLI-ULTRA-CLEAN-CD4862","price":462.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CD-4862-HERO-logo-20261110_8f343f5a-dba8-477f-a393-af8a88a4c26e_0187ef23-0d05-4267-a2ed-d61d1df230d7.jpg?v=1794342756","url":"https:\/\/clinieco.ca\/en-us\/products\/clinieco-ultrasonic-cleaner-cd4862-6l-dental","provider":"CliniEco Medical","version":"1.0","type":"link"}