{"product_id":"clinieco-ultrasonic-cleaner-8l-cs8-0-benchtop","title":"CliniEco Dental Ultrasonic Cleaner — 8 L Benchtop, CS8.0 49 kHz with Heater","description":"\u003cp\u003e\u003cstrong\u003eQuick answer:\u003c\/strong\u003e 8 L nominal, 7,000 ml of usable working volume, single frequency at 49 kHz — the size that takes two chairs' instruments in one cycle and the frequency that is easiest on hinged and plated instruments.\u003c\/p\u003e\n\n\u003cp\u003eTwo chairs into one cycle is the argument for an 8 L tank. The morning load runs once instead of twice, and the person doing it is not standing over a tank at 9:15 with patients already seated. The CS8.0 is also the only single-frequency unit in this range: 49 kHz, chosen for small-bubble cavitation into threads and hinges rather than for stripping heavy cement. If most of your soil is heavy, the dual-frequency 6 L is the better fit.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eScope of use.\u003c\/strong\u003e This is a cleaning device. It removes soil — cement residue, polishing paste, dried blood in hinges and threads — as a step in instrument reprocessing. It makes no microbicidal claim, and it does not replace any later step in the workflow set out in the instrument manufacturer’s instructions for use. The \u003ca href=\"https:\/\/www.canada.ca\/en\/health-canada\/services\/drugs-health-products\/medical-devices\/application-information\/guidance-documents\/guidance-document-information-manufacturers-sterilization-reusable-medical-devices.html\"\u003eHealth Canada guidance on reprocessing information\u003c\/a\u003e is why the instrument manufacturer’s instructions — not the cleaner’s specification sheet — decide what happens to a given instrument after it comes out of the tank.\u003c\/p\u003e\n\n\u003ch2\u003eWhat are the CS8.0 specifications?\u003c\/h2\u003e\n\n\u003cp\u003eThe distinction that matters most here is nominal against working volume. An 8 L tank is not 8,000 ml of usable liquid, and the working figure is what decides how many instruments go in.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eTank capacity:\u003c\/strong\u003e 8 L nominal (8,000 ml) — 7,000 ml working volume, 3,600 ml minimum fill\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e 49 kHz, single frequency\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e 450 W\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupply:\u003c\/strong\u003e AC 100–120 V, 60 Hz, North American plug\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDrain:\u003c\/strong\u003e Drain valve fitted for emptying between sessions\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBasket:\u003c\/strong\u003e Stainless basket available as an accessory; internal basket dimensions 31.15 × 21.15 × 5.5 cm\u003c\/p\u003e\u003ctable\u003e\n\u003ccaption\u003eCS8.0 — 8 L benchtop ultrasonic cleaner, specifications as supplied\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eField\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTank capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 L nominal (8,000 ml) — 7,000 ml working volume, 3,600 ml minimum fill\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTank dimensions\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e33.1 × 23.8 × 11.6 cm (length × width × depth), SUS304 stainless steel tank\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49 kHz, single frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC 100–120 V, 60 Hz, North American plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDrain valve fitted for emptying between sessions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless basket available as an accessory; internal basket dimensions 31.15 × 21.15 × 5.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ecETL — Intertek report 220112139GZU-001, to UL 73 and CSA C22.2 No. 68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnit, one-year manufacturer warranty, Canadian warranty support from our Toronto warehouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eList price\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAD $999.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eDoes this unit log cleaning cycles?\u003c\/h2\u003e\n\u003cp\u003eNo. The CS8.0 has no internal data logger and cannot export cycle data to a USB drive or a CSV file. If your reprocessing protocol requires machine-generated cycle records, choose a unit built for that purpose — this model is not one.\u003c\/p\u003e\n\u003cp\u003eWhat the CS8.0 gives you instead is everything needed to keep a defensible manual record: a front-panel timer that counts the cycle, a temperature set-point you can read and write down, and a drain valve so the solution-change date is unambiguous. Under CSA Z314:23 the documentation obligation sits inside your reprocessing quality system rather than inside the appliance, so a signed paper log is not a lesser record — it is the record the standard asks for.\u003c\/p\u003e\n\u003cp\u003eFive fields per cycle is enough: date, operator, temperature set-point, cycle length, and the date the solution was last changed. One line, end of shift.\u003c\/p\u003e\n\u003ch2\u003eWhich tank size in the range fits your room?\u003c\/h2\u003e\n\n\u003cp\u003eAt this size the decision is usually between the 8 L and the 6 L: same family, similar footprint, different frequency and different usable volume. The 6 L is the cassette-size unit; the 8 L is the unit for two chairs' loads or for anyone who wants 49 kHz.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eModel range as listed — tank, frequency and the load each size is built for\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eTank\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eBuilt for\u003c\/th\u003e\n\u003cth\u003eList price (CAD)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-4l-cs4-0-benchtop-dual-frequency\"\u003eCS4.0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 L\u003c\/td\u003e\n\u003ctd\u003e32 \/ 48 kHz\u003c\/td\u003e\n\u003ctd\u003eSingle chair, loose instruments\u003c\/td\u003e\n\u003ctd\u003e$449.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-cd4862-6l-dental\"\u003eCD-4862\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eFull cassette, five temperature presets\u003c\/td\u003e\n\u003ctd\u003e$649.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003eCS6.2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L\u003c\/td\u003e\n\u003ctd\u003e32 \/ 48 kHz\u003c\/td\u003e\n\u003ctd\u003eFull cassette, dual frequency\u003c\/td\u003e\n\u003ctd\u003e$699.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-cd4875-7-5l-dental\"\u003eCD-4875\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eLarger trays, five temperature presets\u003c\/td\u003e\n\u003ctd\u003e$849.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCS8.0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 L\u003c\/td\u003e\n\u003ctd\u003e49 kHz\u003c\/td\u003e\n\u003ctd\u003eTwo chairs into one cycle\u003c\/td\u003e\n\u003ctd\u003e$999.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-20l-cs20-bench\"\u003eCS20\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eSeveral chairs or batch work\u003c\/td\u003e\n\u003ctd\u003e$1,199.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eIf you run more than eight or ten loads a day, neither of these is the answer — that is the point at which a 20 L tank with eight transducers starts to pay for itself. Below that threshold the 8 L removes the second run without turning the bench into a wet room.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/599bf33f4da20fb38d1771bb70a76d19.png?v=1792815581\" alt=\"Six litre benchtop ultrasonic cleaner, straight-on view of the unit with the lid closed\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch2\u003eHow do you run a repeatable cleaning cycle on the CS8.0?\u003c\/h2\u003e\n\n\u003cp\u003eThe 49 kHz setting is quieter and less aggressive than a 32 kHz tank, which changes how you load it rather than how long you run it. Fewer, better-spaced instruments clean better than a packed basket.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eCycle set-up step by step\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStep\u003c\/th\u003e\n\u003cth\u003eSetting\u003c\/th\u003e\n\u003cth\u003eWhy it matters\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1. Fill\u003c\/td\u003e\n\u003ctd\u003e7,000 ml working volume — not the 8,000 ml the tank is named for\u003c\/td\u003e\n\u003ctd\u003eOver-filling to the brim leaves no room for displacement and spills at the seam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2. Heat\u003c\/td\u003e\n\u003ctd\u003eBring the solution to the temperature printed on the solution label\u003c\/td\u003e\n\u003ctd\u003eEnzyme activity has a temperature window; a cold tank under-performs on the same load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3. Load\u003c\/td\u003e\n\u003ctd\u003eBasket only, instruments not touching each other\u003c\/td\u003e\n\u003ctd\u003eCavitation is blocked where two surfaces meet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4. Run\u003c\/td\u003e\n\u003ctd\u003eOne full cycle per load, timed from the panel\u003c\/td\u003e\n\u003ctd\u003eA repeatable interval is what makes the log meaningful\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5. Drain, dry, record\u003c\/td\u003e\n\u003ctd\u003eEmpty through the valve, dry the chamber, write the entry\u003c\/td\u003e\n\u003ctd\u003eThe record is what an inspection reads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eBecause 49 kHz works with smaller bubbles, it reaches into threads and box joints that larger bubbles miss, but it also gives up some stripping power on set cement. If you routinely clean crown-and-bridge work with cement residue, pre-wipe the instrument before it goes in the tank rather than extending the cycle.\u003c\/p\u003e\n\n\u003cp\u003eWhat an infection-control inspection asks for is the record, not the machine. Ontario’s provincial reprocessing guidance asks for \u003cem\u003edocumentation and maintenance of records for each component of the cleaning, disinfection and\/or sterilization process\u003c\/em\u003e, based on the manufacturer’s recommendations, and repeats that records \u003cem\u003emust be retained according to the facility’s policy\u003c\/em\u003e (\u003ca href=\"https:\/\/www.publichealthontario.ca\/-\/media\/Documents\/B\/2013\/bp-cleaning-disinfection-sterilization-hcs.pdf?rev=074097c0ef2343379b7bb17d97b75526\u0026amp;sc_lang=en\"\u003ePublic Health Ontario, “Best Practices for Cleaning, Disinfection and Sterilization of Medical Equipment\/Devices In All Health Care Settings”, 3rd edition, checked 2026-11-07\u003c\/a\u003e). A unit with a drain valve, a visible timer and a stable temperature set-point is what makes that record short enough to write at the end of a shift.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does the cETL mark cover, and what does it not?\u003c\/h2\u003e\n\n\u003cp\u003eThe CS8.0 carries a cETL mark from Intertek under report 220112139GZU-001, the same report that covers the 4 L unit. The mark on the unit is an ETL mark issued by Intertek, tested against \u003ca href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL73\"\u003eUL 73\u003c\/a\u003e and \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/C22.2%20NO.%2068-18\/\"\u003eCSA C22.2 No. 68\u003c\/a\u003e. It is an electrical safety certificate. It is not a UL listing and it is not CSA certification, and it says nothing about how well the tank cleans. Canadian reprocessing practice sits on a separate standard, \u003ca href=\"https:\/\/store.csastandards.org\/store\/product\/2430344\/\"\u003eCSA Z314:23\u003c\/a\u003e, whose scope puts documentation inside the reprocessing quality system rather than inside the appliance.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eWhat the electrical certificate covers, and what it does not\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCovers\u003c\/th\u003e\n\u003cth\u003eDoes not cover\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical safety of the appliance, assessed to UL 73 and CSA C22.2 No. 68\u003c\/td\u003e\n\u003ctd\u003eCleaning performance on your instruments, on your water hardness, or at your solution concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe specific unit family named on Intertek report 220112139GZU-001\u003c\/td\u003e\n\u003ctd\u003eThe condition of an individual unit after a drop, a repair, or a modification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance of the supply, plug and cord assembly for the North American market\u003c\/td\u003e\n\u003ctd\u003eAny clinical outcome, or any claim that the unit removes or inactivates micro-organisms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe identity of the certificate holder and the factory it was issued to\u003c\/td\u003e\n\u003ctd\u003eYour own reprocessing records, which are yours to keep and produce\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\n\u003ch2\u003eWhat is in the box, and what should be ordered with it?\u003c\/h2\u003e\n\n\u003cp\u003eOne cleaner, 8 L, 110 V with a North American plug and the manufacturer warranty. The stainless basket is an accessory, so ask for it explicitly if you want it shipped in the same box. No plumbing or drain pump is required.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003eMulti-enzyme ultrasonic cleaning solution\u003c\/a\u003e is what goes in the tank, sold as a 1 L bottle or a 5 L pail and diluted 1:400 to 1:600. The \u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003e6 L CS6.2\u003c\/a\u003e is the unit to look at if your load grows into full cassettes. Read \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/choosing-ultrasonic-cleaner-tank-size-canadian-dental-clinic\"\u003ehow to choose a tank size\u003c\/a\u003e and \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/what-should-a-canadian-clinic-record-for-ultrasonic-cleaning-log-fields-and-retention\"\u003ewhat to record on the cleaning log\u003c\/a\u003e before you commit to a size.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does one tank fill cost in cleaning solution?\u003c\/h2\u003e\n\u003cp\u003eAn 8 L bath is usually bought for two chairs feeding one cycle, and that doubles the chemistry per fill against the 4 L unit while halving the number of fills a bottle gives. The arithmetic below uses this page’s own nominal capacity, so the millilitres are the ones your staff will actually measure at the bench.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCS8.0 — concentrate per full tank and pack yield at the two label dilutions\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eDilution on the label\u003c\/th\u003e\n\u003cth\u003eConcentrate per full tank (8 L nominal capacity)\u003c\/th\u003e\n\u003cth\u003eFills from a 1 L bottle\u003c\/th\u003e\n\u003cth\u003eFills from a 5 L pail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1:400 — heavier soil\u003c\/td\u003e\n\u003ctd\u003e≈ 20 mL\u003c\/td\u003e\n\u003ctd\u003e50 fills\u003c\/td\u003e\n\u003ctd\u003e250 fills\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1:600 — light soil\u003c\/td\u003e\n\u003ctd\u003e≈ 13.3 mL\u003c\/td\u003e\n\u003ctd\u003e75 fills\u003c\/td\u003e\n\u003ctd\u003e375 fills\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCost per fill = the current pack price divided by the fills in that pack. Both halves of that sum move — the pack price with the market, the fills with how full you run the tank — which is why the page gives the arithmetic instead of a per-cycle figure. If your protocol changes the bath once per working day, five days a week, 50 fills is roughly 10 working weeks from one bottle.\u003c\/p\u003e\n\n\u003ch2\u003eWhich cleaning solution goes in this tank, and when should it be changed?\u003c\/h2\u003e\n\u003cp\u003eThe tank takes the \u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003emulti-enzyme ultrasonic cleaning concentrate\u003c\/a\u003e in 1 L bottles or 5 L pails, diluted 1:400 to 1:600. Low-foam matters more as the tank gets bigger: the larger the free surface, the more foam a foaming product would build, and foam is cavitation energy that never reaches the instruments. Working window on the label is 20–50 °C over 2 to 10 minutes; sealed shelf life is 24 months, 90 days after opening.\u003c\/p\u003e\n\u003cp\u003eHow often the bath is changed belongs to the solution label and your facility protocol. The drain valve on this unit is what makes that a short job: empty, rinse, refill, and write the date on the log in the same line as the temperature and the operator. That record is what an inspection reconstructs the step from — Ontario guidance asks for \u003cem\u003edocumentation and maintenance of records for each component of the cleaning, disinfection and\/or sterilization process\u003c\/em\u003e, retained \u003cem\u003eaccording to the facility’s policy\u003c\/em\u003e (\u003ca href=\"https:\/\/www.publichealthontario.ca\/-\/media\/Documents\/B\/2013\/bp-cleaning-disinfection-sterilization-hcs.pdf?rev=074097c0ef2343379b7bb17d97b75526\u0026amp;sc_lang=en\"\u003ePublic Health Ontario, 3rd edition, checked 2026-11-07\u003c\/a\u003e).\u003c\/p\u003e\n\n\u003ch2\u003eWhat is the lead time, and what maintenance does the unit need?\u003c\/h2\u003e\n\u003cp\u003eThis unit is built to order — allow 3–4 weeks, and we confirm the dispatch date before it ships. The manufacturer warranty runs one year and is supported in Canada. CliniEco Medical holds Health Canada establishment licence (MDEL) #35334 — importer and distributor — which is separate from the warranty terms. What the unit asks of you in return is short, and mostly about the bath rather than the electronics.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCS8.0 — routine maintenance and why each item is on the list\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTask\u003c\/th\u003e\n\u003cth\u003eInterval\u003c\/th\u003e\n\u003cth\u003eWhy it matters\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain and refill\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAt the interval the solution label and your protocol set\u003c\/td\u003e\n\u003ctd\u003eSoil load accumulates in the bath whatever the instruments look like when they come out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRun a fresh fill before the first load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery refill\u003c\/td\u003e\n\u003ctd\u003eDissolved air in new solution damps cavitation, and the bath should be at working temperature before an instrument goes in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRinse tank and basket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery change\u003c\/td\u003e\n\u003ctd\u003eResidue left on stainless carries soil into the next fill and films the tank over time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWipe lid and check cord, plug and drain valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003ctd\u003eThe three parts a drop or a wipe-down damages first\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeep the level above the working minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery cycle\u003c\/td\u003e\n\u003ctd\u003eRunning dry is the one failure mode that ends a tank’s service life early\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFill to the marked working volume rather than to the rim: the 8 L tank has a 7,000 ml working volume and a 3,600 ml minimum fill, and running near the minimum shortens the bath’s useful life in a busy room because the soil load builds faster.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRelated reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/ultrasonic-cleaner-canadian-clinic-tank-frequency-proof-of-clean\"\u003eUltrasonic Cleaner for a Canadian Clinic: Tank, Frequency and Proof of Clean\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/ultrasonic-cleaner-solution-canada-dilution-ratios-case-sizes-where-to-buy\"\u003eUltrasonic Cleaner Solution in Canada: Dilution Ratios and Case Sizes\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/instrument-cleaning-before-sterilization-why-it-matters\"\u003eInstrument Cleaning Before Sterilization: Why Pre-Cleaning Matters\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCliniEco Medical is a licensed medical device establishment (MDEL #35334). We are the Canadian importer of record for this unit: duties and brokerage are handled on our side, and you receive it from our Toronto warehouse with a one-year manufacturer warranty supported in Canada. Questions on which size fits your room go to our \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003esterilization desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt to order.\u003c\/strong\u003e Allow 3–4 weeks — we confirm the dispatch date before the unit ships.\u003c\/p\u003e","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":49376919716062,"sku":"CLI-ULTRA-CLEAN-80","price":711.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CS8.0-HERO-logo-20261110_21525ffc-870f-4967-a21d-f6513fd66b79_e693689f-41fa-4f94-a4ac-fdbfb1a3854c.jpg?v=1794342734","url":"https:\/\/clinieco.ca\/en-us\/products\/clinieco-ultrasonic-cleaner-8l-cs8-0-benchtop","provider":"CliniEco Medical","version":"1.0","type":"link"}