{"product_id":"clinieco-sterilization-compliance-kit-pre-vacuum","title":"Sterilization Compliance Kit — A — For Pre-Vacuum (Class B) Sterilizers","description":"\u003cp\u003e\u003cstrong\u003eA — For pre-vacuum (Class B) sterilizers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEverything one sterilizer needs to keep its monitoring in order for a month — with 10% spare, so a busy week never leaves you short.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKit A is sized for one Class B (pre-vacuum) sterilizer and about a month of monitoring — with the 10% spare already built in.\u003c\/strong\u003e The daily spore test is the \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-50-pack\"\u003e24-hour self-contained 50-pack\u003c\/a\u003e; the rest of the box is what a vacuum cycle needs around it: Bowie-Dick packs, a Class 5 integrator, pouches and indicator tape.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/inside-the-clinieco-sterilization-compliance-assistant-kit-what-dental-teams-get\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/A_01_kit_contents.png?v=1791474575\" alt=\"Sterilization Compliance Kit — A — For Pre-Vacuum (Class B) Sterilizers\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eWhich parts of the kit are used on every sterilization day, and which only occasionally?\u003c\/h2\u003e\n\u003cp\u003eThree things are daily: one biological indicator, its control, and — on a pre-vacuum sterilizer — a Bowie-Dick test on the first cycle of the day. The Class 5 integrator travels with the work, inside every tray and large pack, so it is consumed by load shape rather than by calendar. Pouches and indicator tape run out at their own pace: the kit holds 800 pouches and a three-roll tape set, counted on a 3–4 chair practice using 400–750 pouches a month, so an empty drawer is not the reason a tray waits.\u003c\/p\u003e\n\u003ch2\u003eDoes the kit replace the daily record a dental practice has to keep?\u003c\/h2\u003e\n\u003cp\u003eNo — it supplies the articles the record describes. The record itself is your practice's daily sterilization log, and the obligation to complete it stays with the practice whatever it buys. What we can take out is the friction: the printable daily record on our \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003ecompliance log centre\u003c\/a\u003e is free, needs no account, and has fields for the date, the cycle, the sterilizer, the vial lot number and the result. Copy the lot number off the box and the entry writes itself. Where your provincial requirement reads differently from the numbers below, tell us — we would rather correct the kit than have you rely on the wrong count.\u003c\/p\u003e\n\u003ch2\u003eHow many biological indicators does one Class B sterilizer need in a month, and what does the kit cost per sterilization day?\u003c\/h2\u003e\n\u003cp\u003eFifty, on the pattern of a test plus a control each day the sterilizer runs: two vials a day, so a 50-vial box covers 25 sterilization days — a month with spare, not a second month. The kit lists at $249.00, which is about $9.96 per sterilization day across those 25 days, and that figure already includes the Bowie-Dick packs, the integrator, the pouches and the tape. Kit B, for gravity and non-vacuum sterilizers, lists at $189.00 and leaves out the Bowie-Dick packs, because that test measures air removal and only means something on a pre-vacuum machine.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eKit A contents — pack size, quantity in the box and how long each part covers (pre-vacuum \/ Class B)\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem in the kit\u003c\/th\u003e\n\u003cth\u003ePack size\u003c\/th\u003e\n\u003cth\u003eQuantity in the box\u003c\/th\u003e\n\u003cth\u003eHow long it covers\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBiological indicator, 24-hour readout\u003c\/td\u003e\n\u003ctd\u003e50-pack\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e25 sterilization days at test plus control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBowie-Dick test pack, ISO 11140-5 Type 2\u003c\/td\u003e\n\u003ctd\u003e6-pack\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003efirst cycle of each day, 24 test days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteam chemical integrator, Class 5\u003c\/td\u003e\n\u003ctd\u003e100-pack\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003einside every tray and large pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterilization pouch, Class 4 dual indicator\u003c\/td\u003e\n\u003ctd\u003e200 per box\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e800 pouches, sized on 400–750 a month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoclave indicator tape\u003c\/td\u003e\n\u003ctd\u003e3-roll set\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003esealing and labelling the packs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit A, complete\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003ethe five lines above\u003c\/td\u003e\n\u003ctd\u003e$249.00, about one month for one sterilizer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eWhat you reorder, and what you buy once.\u003c\/strong\u003e The kit is the monthly line. The \u003ca href=\"\/en-us\/products\/clinieco-constant-heat-pouch-sealer-200-c-12mm-seal-110v-dental-sterilization\"\u003econstant-heat pouch sealer\u003c\/a\u003e sits outside it because it lasts, and the \u003ca href=\"\/en-us\/pages\/clinic-supply-planner\"\u003eclinic supply planner\u003c\/a\u003e sits outside it because sizing a second sterilizer is arithmetic, not a purchase. A question about your own setup goes to the \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003ecompliance desk\u003c\/a\u003e, which answers in writing with the standard cited. CliniEco Medical imports this kit under MDEL #35334.\u003c\/p\u003e\n\u003ch2\u003eWhy buy this kit from us\u003c\/h2\u003e\n\u003cp\u003eSterilization compliance for clinics is all we do. So the kit comes with the parts most suppliers leave out:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantities we can show you the working for\u003c\/strong\u003e — built on the RCDSO's daily testing rule, with spare so a busy week never leaves you short. No guessing at how much you actually use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe record sheet your province asks for\u003c\/strong\u003e — ready to print, free, no account, nothing to buy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA named person who can look up your lot number\u003c\/strong\u003e — email \u003ca href=\"mailto:alina@clinieco.ca\"\u003ealina@clinieco.ca\u003c\/a\u003e. Not a ticket queue.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAny compliance question, any time\u003c\/strong\u003e — ask us; even if you never buy anything from us, we're glad to talk it through.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it does not do:\u003c\/strong\u003e it won't tell you whether a cycle passed. That depends on how the sterilizer is loaded and run — that part stays with your team. We supply the monitoring and the guidance around it, not a guarantee of outcomes.\u003c\/p\u003e\u003ch2\u003eQuestions clinics ask before buying\u003c\/h2\u003e\n\u003ch3\u003eDo I need an incubator?\u003c\/h3\u003e\n\u003cp\u003eYes. These indicators have to be incubated at 58 ± 2 °C before you can read them. A self-contained indicator does not need a reader, but it does need an incubator. If your clinic doesn't have one, \u003ca href=\"\/en-us\/products\/clinieco-24-hour-biological-indicator-incubator-precision-dry-block-15-wells\"\u003ewe stock one\u003c\/a\u003e — or email us and we'll help you sort it out rather than send you something you can't use.\u003c\/p\u003e\n\u003ch3\u003eHow do I know this is the right kit for my sterilizer?\u003c\/h3\u003e\n\u003cp\u003eKit A is for pre-vacuum (Class B) sterilizers — the ones with a vacuum pump that need a daily Bowie-Dick test. Kit B is for gravity \/ non-vacuum sterilizers, which don't. If you're not sure which yours is, \u003ca href=\"\/en-us\/products\/clinieco-sterilization-compliance-kit-gravity-non-vacuum\"\u003eKit B\u003c\/a\u003e explains the difference, or email us and we'll tell you.\u003c\/p\u003e\n\u003ch3\u003eHow long does one kit last?\u003c\/h3\u003e\n\u003cp\u003eAbout a month for a clinic running one sterilizer on a normal schedule. The 50 biological indicators are sized on the RCDSO requirement of a test plus a control each day the sterilizer runs, with spare for the busier weeks.\u003c\/p\u003e\n\u003ch3\u003eWhy does Kit A include Bowie-Dick tests and Kit B doesn't?\u003c\/h3\u003e\n\u003cp\u003eBowie-Dick is a test of air removal in the chamber. It is only meaningful on pre-vacuum (Class B) sterilizers, so it isn't part of Kit B.\u003c\/p\u003e\n\u003ch3\u003eWhy is there a Class 5 integrator in both kits?\u003c\/h3\u003e\n\u003cp\u003eIt goes inside trays and large packs where the pouch indicator can't reach. That applies to both sterilizer types, so both kits include it.\u003c\/p\u003e\n\u003ch3\u003eCan I buy the items separately?\u003c\/h3\u003e\n\u003cp\u003eYes — every item in the kit is sold on its own. The kit is for clinics that would rather not work out the quantities, not a way to lock you into a bundle.\u003c\/p\u003e\n\u003ch3\u003eWhat if I run more than one sterilizer, or more than 2 chairs?\u003c\/h3\u003e\n\u003cp\u003eEmail us before ordering and we'll size it for your volume. The kit is built for a 1–2 chair clinic running one autoclave — it is not meant for 6+ chairs.\u003c\/p\u003e\u003ch2\u003eWhere these numbers come from\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBiological indicator every day the sterilizer runs, \u003cstrong\u003eplus a control test\u003c\/strong\u003e — RCDSO Standard 5542, p. 8 (and 5539, p. 23). That is the basis for 50 indicators a month, not 25.\u003c\/li\u003e\n\u003cli\u003eBowie-Dick: \u003cstrong\u003epre-vacuum \/ Class B only, first cycle of each day\u003c\/strong\u003e — RCDSO 5542, p. 7; Public Health Ontario 7.18. A gravity sterilizer does not require it, which is why it is in Kit A only.\u003c\/li\u003e\n\u003cli\u003ePouch count is based on a 3–4 chair practice running 400–750 pouches a month; we round up so you don't run short.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVerified 2026-10-08. If your provincial requirements differ, tell us — we'd rather correct the kit than have you rely on the wrong number.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the kit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBiological Indicator — 24-Hour Readout, 50-Pack × 1\u003c\/li\u003e\n\u003cli\u003eBowie-Dick Test Pack — ISO 11140-5 Type 2, 6-pack × 4\u003c\/li\u003e\n\u003cli\u003eSteam Chemical Integrator — Class 5, 100-Pack × 1 \u003cem\u003e(for your trays and large packs)\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eSterilization Pouch — Class 4 Dual Indicator, 200-pack box × 4\u003c\/li\u003e\n\u003cli\u003eAutoclave Tape — Sterilization Indicator Tape, 3-Roll Set × 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDesigned for:\u003c\/strong\u003e 1–2 chairs · one Class B (pre-vacuum) sterilizer · no dedicated infection-control staff\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot for:\u003c\/strong\u003e 6+ chairs (larger volume — ask us) · sterilizers other than steam\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCovers\u003c\/strong\u003e — products, guidance, records, a specialist who can see your lot number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes not cover\u003c\/strong\u003e — whether a cycle passes. That depends on how the sterilizer is operated and loaded — that part stays with your team.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eRunning a gravity \/ non-vacuum sterilizer? That is \u003ca href=\"\/en-us\/products\/clinieco-sterilization-compliance-kit-gravity-non-vacuum\"\u003eKit B\u003c\/a\u003e.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/which-standards-medical-bowie-dick-test-pack-us-vs-canada\"\u003eWhich Standards Apply to Medical Bowie-Dick Test Pack in the US vs Canada? Sizes and Sourcing\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/how-often-us-vs-canadian-clinics-sterilizer-testing-incubator-guide\"\u003eHow Often Must US vs Canadian Clinics Run Sterilizer Testing? 24-Hour Biological Indicator Incubator Ordering \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/which-standards-medical-biological-indicator-us-vs-canada\"\u003eWhich Standards Apply to Medical Biological Indicator in the US vs Canada? Sizes and Sourcing\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/which-standards-medical-autoclave-tape-us-vs-canada\"\u003eWhich Standards Apply to Medical Autoclave Tape in the US vs Canada? Sizes and Sourcing\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":49172696957150,"sku":"CLI-STER-KIT-PREVAC","price":178.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/KIT-A-HERO-logo-20261110_3535e8a9-6ddf-4841-8968-37dc4b29c6ba.jpg?v=1794343780","url":"https:\/\/clinieco.ca\/en-us\/products\/clinieco-sterilization-compliance-kit-pre-vacuum","provider":"CliniEco Medical","version":"1.0","type":"link"}