{"product_id":"clinieco-medical-biological-indicator-24h-rapid-readout-50-pack","title":"CliniEco Medical Biological Indicator — 24-Hour Self-Contained, 50 Tests","description":"\u003cdiv\u003e\n\u003cp\u003eCliniEco Medical supplies 24-hour biological indicators from Toronto, Ontario, and ships across Canada.\u003c\/p\u003e\n\u003cp\u003eEach box contains 50 self-contained spore strips for steam sterilization, read out in 24 hours.\u003c\/p\u003e\n\u003cp\u003eEach lot is manufactured to ISO 11138-3 and ISO 11138-1, and carries Health Canada MDEL #35334.\u003c\/p\u003e\n\u003cp\u003eLot-level CoA and D-value reports are available on request, and orders ship from stock in Toronto.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv style=\"border:1px solid #E5E7EB;border-radius:8px;padding:14px 16px;margin:0 0 18px;background:#F8FAFB\"\u003e\n\u003cstrong\u003eProof for this lot\u003c\/strong\u003e — D-value report (steam, 121 °C) · lot-level CoA on request · Health Canada MDEL #35334. \u003ca href=\"\/en-us\/pages\/sterilization-assurance\"\u003eHow we verify sterilization monitoring →\u003c\/a\u003e\n\u003c\/div\u003e\u003cdiv class=\"clini-prod\"\u003e \u003cdiv class=\"clini-prod-hero\"\u003e \u003ch2\u003eHow many test days does a 50-pack of 24-hour indicators cover?\u003c\/h2\u003e\n\u003cp\u003eFifty vials is fifty test days for one sterilizer, because the daily routine takes one indicator per unit on every day the unit is used. A room that runs its autoclave on 22 to 25 days a month therefore works through a box in roughly two months on a single unit, and in roughly one month once a second sterilizer is added and takes its own vial on each of those days. That arithmetic is what the three box sizes are for: the \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003e25-vial box\u003c\/a\u003e suits a light single-unit schedule, fifty sits between the two, and the \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-100-pack\"\u003e100-vial box\u003c\/a\u003e is the two-unit, most-days-of-the-month format.\u003c\/p\u003e\n\u003ch2\u003eWhich packing suits a two-sterilizer room better — two 50-packs or one 100-pack?\u003c\/h2\u003e\n\u003cp\u003eBoth put 100 vials on the shelf, so the decision is about how the stock is opened rather than how much arrives. Two 50-vial boxes let one box stay sealed while the working box runs dry, which keeps an untouched lot intact until the first box is finished; one 100-vial box means both sterilizers draw from the same opened container from day one. If the second unit is new, or runs on an irregular schedule, the two-box route mirrors the way its use days actually accumulate. Read the lot code on the box against the certificate that travels with it either way, because the record is per lot and not per box size.\u003c\/p\u003e\n\u003ch2\u003eWhat does the 24-hour readout change about releasing a load?\u003c\/h2\u003e\n\u003cp\u003eIt moves the decision into the next working day instead of the day after. The vial is incubated at 56–60 °C (58 ± 2 °C) in a dry-block incubator and read at 24 hours: purple means no spore growth and the load releases, yellow means the spores survived and everything in that load goes back for re-sterilization and a repeat test. One unexposed indicator from the same lot runs as a positive control on each day of testing — if the control does not turn yellow, the run itself is not valid and the day's result cannot be read as a pass.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003e24-hour self-contained biological indicators: what the 50-vial box carries as listed\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eAs listed on this page\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicators per box\u003c\/td\u003e\n\u003ctd\u003e50 self-contained vials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChallenge organism\u003c\/td\u003e\n\u003ctd\u003eGeobacillus stearothermophilus ATCC 7953\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpore load\u003c\/td\u003e\n\u003ctd\u003e≥1.0 × 10⁶ CFU per vial, typical 1.0–1.2 × 10⁶ as stated on each lot CoA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadout\u003c\/td\u003e\n\u003ctd\u003e24-hour visual colour change, no reader or UV lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncubation\u003c\/td\u003e\n\u003ctd\u003e56–60 °C (58 ± 2 °C) dry-block incubator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCycles covered\u003c\/td\u003e\n\u003ctd\u003e121 °C gravity-displacement and 132–135 °C vacuum-assisted steam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eSelf-contained vial with growth medium, no transfer step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTesting frequency\u003c\/td\u003e\n\u003ctd\u003eEvery day of use per Ontario dental guidance; at least weekly as the CDC \/ AAMI ST79 floor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003ctd\u003eCliniEco MDEL #35334\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/24-hour-self-contained-biological-indicator-pack-sizes-incubation-record\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/p50_01_main_1500_E2.jpg?v=1793459597\" alt=\"CliniEco Medical Biological Indicator — 24-Hour Self-Contained, 50-Pack\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eA test day only counts if it is written down: the printable \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003espore-test log sheet\u003c\/a\u003e carries the date, sterilizer, lot and result, and the same page holds the \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003esterilization log generator\u003c\/a\u003e for the cycle record behind it. Documentation questions about what to keep, and for how long, go to the \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003ecompliance documentation desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eCultures and consumables reach Canadian clinics from CliniEco Medical under MDEL #35334.\u003c\/p\u003e\n\u003ch2 class=\"clini-prod-title\"\u003eCliniEco Medical Biological Indicator — 24-Hour Self-Contained, 50-Pack\u003c\/h2\u003e \u003cp\u003eDaily biological monitoring for Canadian dental clinics — 24-hour results, with the per-test figure taken from the box amount on this page\u003c\/p\u003e\n\u003cp\u003eIn-office monitoring — incubate and read on site; no need to send vials to an outside lab.\u003c\/p\u003e \u003cp\u003eG. stearothermophilus ATCC 7953 · ISO 11138-3 \u003c\/p\u003e\n\u003c\/div\u003e \u003cdiv class=\"clini-prod-section\"\u003e \u003ch2\u003eDaily spore testing — 24-hour results\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003e50 self-contained biological indicators in the box, priced on this page — the per-test figure is that amount divided by fifty.\u003c\/strong\u003e Each vial contains Geobacillus stearothermophilus ATCC 7953 spores (≥1.0 × 10\u003csup\u003e6\u003c\/sup\u003e CFU per vial, typical 1.0–1.2 × 10\u003csup\u003e6\u003c\/sup\u003e, as stated on each lot CoA), the standard challenge organism for steam sterilization, in a self-contained vial with growth medium for a rapid visual readout in 24 hours instead of 48. In Ontario, the RCDSO requires a biological indicator for each sterilizer on every day that it is used — daily monitoring, not weekly. The weekly baseline is the CDC \/ AAMI ST79 standard in most US states. Each monitoring day uses two indicators — one test plus one unexposed positive control — so a 50-pack gives about 25 monitoring days.\u003c\/p\u003e\n\u003c\/div\u003e \u003cdiv class=\"clini-trust\"\u003e \u003ch3\u003e🛡️ Where Your BIs Come From — Traceability You Can Verify\u003c\/h3\u003e \u003cdiv class=\"clini-trust-grid\"\u003e \u003cdiv class=\"clini-trust-item\"\u003e \u003ch4\u003e🏭 Factory Documentation on Request\u003c\/h4\u003e \u003cp\u003eEvery lot ships with full manufacturer documentation available on request — the same supply chain used by established sterilization brands.\u003c\/p\u003e\n\u003c\/div\u003e \u003cdiv class=\"clini-trust-item\"\u003e \u003ch4\u003e🧪 Standard Challenge Organism\u003c\/h4\u003e \u003cp\u003eGeobacillus stearothermophilus ATCC 7953 — the internationally accepted steam sterilization challenge organism, ≥1.0 × 10\u003csup\u003e6\u003c\/sup\u003e CFU per vial (typical 1.0–1.2 × 10\u003csup\u003e6\u003c\/sup\u003e), verified per ISO 11138-1.\u003c\/p\u003e\n\u003c\/div\u003e \u003cdiv class=\"clini-trust-item\"\u003e \u003ch4\u003e📋 Batch Traceability\u003c\/h4\u003e \u003cp\u003eEvery pack carries lot-level traceability. Batch D-value and spore-count documentation available — ask us for the certificate of analysis for your lot.\u003c\/p\u003e\n\u003c\/div\u003e \u003cdiv class=\"clini-trust-item\"\u003e \u003ch4\u003e🇨🇦 Canadian Import \u0026amp; Distribution\u003c\/h4\u003e \u003cp\u003eImported and distributed by CliniEco Medical (MDEL #35334) — with English\/French labeling and Toronto-based support.\u003c\/p\u003e\n\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"clini-trust-item\" style=\"margin-top:12px;\"\u003e \u003ch4\u003e📦 Importer \u0026amp; Regulatory Information\u003c\/h4\u003e \u003cp style=\"font-size:13px;line-height:1.6;color:#374151;\"\u003e Imported and distributed by: \u003cstrong\u003eCliniEco Medical\u003c\/strong\u003e (Ecology Source New Energy Technology Co., Ltd.)\u003cbr\u003e 255 Duncan Mill Road, Suite 512, Toronto, ON M3B 3H9, Canada\u003cbr\u003e Storage: 15–30°C, away from direct sunlight and moisture. Shelf life: 24 months from manufacture; EXP printed on every vial. For professional use only. Do not use if damaged or expired.\u003cbr\u003e Conforms to EN ISO 11138-3 (moist heat) and EN ISO 11138-1 — third-party test report XDX522601161208BST (BST Testing, EN ISO 11138-1:2017 and -3:2017) available on request. For steam sterilization only — not for dry heat, chemical vapour, ethylene oxide (EO) or other low-temperature processes. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHave a question about your own facility?\u003c\/strong\u003e Send it in and you will get a written answer specific to your setup, with the regulation or standard it is based on cited. \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003eAsk your compliance question\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e  \u003cdiv class=\"clini-cert-row\"\u003e \u003cspan class=\"clini-cert-chip\"\u003e✅ ISO 11138-3 Compliant\u003c\/span\u003e \u003cspan class=\"clini-cert-chip\"\u003e✅ ATCC 7953 Challenge Organism\u003c\/span\u003e \u003cspan class=\"clini-cert-chip\"\u003e✅ Batch Traceability\u003c\/span\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"clini-prod-section\"\u003e \u003cdiv class=\"clini-prod-section\"\u003e\n\u003ch2\u003eWhen the 50-Pack Fits Better Than the 25 or the 100\u003c\/h2\u003e\n\u003cp\u003eA test day takes \u003cb\u003etwo\u003c\/b\u003e indicators from the same lot — the vial that runs through the cycle and the unexposed control that must turn yellow for the run to be valid. Work out the year as test days multiplied by two, then pick the box that lands closest to it without leaving you short mid-quarter.\u003c\/p\u003e\n\u003ctable class=\"clini-prod-table\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTest days a year\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eIndicators a year\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e50-packs a year\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eCost in 50-packs, $109.99 each\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eThe same year bought as 25-packs, $69.99 each\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e$109.99\u003c\/td\u003e\n\u003ctd\u003e2 boxes — $139.98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e$219.98\u003c\/td\u003e\n\u003ctd\u003e3 boxes — $209.97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e$219.98\u003c\/td\u003e\n\u003ctd\u003e3 boxes — $209.97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e$219.98\u003c\/td\u003e\n\u003ctd\u003e4 boxes — $279.96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e49\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e$219.98\u003c\/td\u003e\n\u003ctd\u003e4 boxes — $279.96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis box sits between the entry pack and the yearly box. Choose it when your test calendar is real but not daily, or when you want the ordering rhythm to be quarterly instead of monthly.\u003c\/p\u003e\n\u003ch3\u003eTwo situations this box is built for\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eTwo sterilizers on alternating days.\u003c\/b\u003e Each unit is tested on the days it actually runs, so the test days roughly double and the box empties at twice the pace. Buying two 25-packs a month for that rhythm costs more than one 50-pack a quarter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eA two-month to three-month restock cycle.\u003c\/b\u003e A practice that runs two or three days a week gets about two to three months of cover from this box, which means four deliveries a year and a single lot number per quarter — easier to file and easier to trace back if a lot is ever questioned.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOne sterilizer plus a backup unit.\u003c\/b\u003e If the backup is run only on weeks when the main unit is serviced, the extra test days land in bursts; the 50-pack absorbs the burst without a special order.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhen the 50-pack is the wrong box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMore than 49 test days a year: step to the 100-pack, because a hundred vials spread the box amount further and the per-test gap compounds across a year.\u003c\/li\u003e\n\u003cli\u003eUnder 25 test days a year, or a new routine you have not yet proven: the 25-pack at $69.99 covers twelve test days and keeps the exposure small.\u003c\/li\u003e\n\u003cli\u003eStorage that runs warm or damp: indicator vials belong in a dry place at room temperature, and a box that sits for a year in a utility room is a risk you do not need to take for a few dollars a box.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat one box covers, week by week\u003c\/h3\u003e\n\u003cp\u003eFifty indicators is 25 test days. At five test days a week that is five weeks; at three days a week, about eight weeks; at two days a week, about twelve. Write your own test days a week into that line before ordering — if the answer is over fourteen weeks, the box will outlast your patience before it outlasts the shelf, and the 25-pack is the better rhythm.\u003c\/p\u003e\n\n\u003ch3\u003eThe same year, priced against the neighbours\u003c\/h3\u003e\n\u003ctable class=\"clini-prod-table\"\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTest days a year\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eIndicators\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eBought as 50-packs\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eBought as 25-packs\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eBought as 100-packs\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e1 box — $109.99\u003c\/td\u003e\n\u003ctd\u003e2 boxes — $139.98\u003c\/td\u003e\n\u003ctd\u003e1 box — $189.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003ctd\u003e2 boxes — $219.98\u003c\/td\u003e\n\u003ctd\u003e4 boxes — $279.96\u003c\/td\u003e\n\u003ctd\u003e1 box — $189.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eThat last row is the honest one: at 80 indicators a year a single 100-pack is cheaper than two 50-packs, but it leaves twenty vials on the shelf. If your test days are steady and the lot date allows it, the larger box wins on price; if the routine is still settling, pay the small premium and keep the shelf light.\u003c\/p\u003e\n\u003ch2\u003eHow to Read Your 24-Hour Result\u003c\/h2\u003e\n\u003ctable class=\"clini-prod-table\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eNegative — pass\u003c\/td\u003e\n\u003ctd\u003eThe medium stays purple after 24 hours at 56–60 °C (58 ± 2 °C): no spore growth. Release the load.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositive — fail\u003c\/td\u003e\n\u003ctd\u003eThe medium turns yellow: spores survived the cycle. Re-sterilize everything in that load and re-test before releasing instruments.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncubation\u003c\/td\u003e\n\u003ctd\u003e56–60 °C (58 ± 2 °C) dry-block incubator; read at 24 hours (this indicator is rated for a 24-hour readout, not 48 hours).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositive control\u003c\/td\u003e\n\u003ctd\u003eRun one unexposed indicator from the same lot as a control on each day you test; it must turn yellow. If the control does not grow, the test run is not valid.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading is visual\u003c\/td\u003e\n\u003ctd\u003eNo reader or UV lamp is needed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd\u003eManufacturer's instructions for use supplied with each lot.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e \u003ctable class=\"clini-prod-table\"\u003e \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eCliniEco Medical\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eOrganism\u003c\/td\u003e\n\u003ctd\u003eGeobacillus stearothermophilus ATCC 7953 — ≥1.0 × 10\u003csup\u003e6\u003c\/sup\u003e CFU per vial (typical 1.0–1.2 × 10\u003csup\u003e6\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eReadout\u003c\/td\u003e\n\u003ctd\u003e24-hour rapid visual readout (color change)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCycles\u003c\/td\u003e\n\u003ctd\u003e121°C gravity \u0026amp; 132–135°C vacuum-assisted steam sterilization\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eSelf-contained vial with growth medium — no transfer steps\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePack Size\u003c\/td\u003e\n\u003ctd\u003e50 indicators per pack; monitoring log template included\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003eDaily per sterilizer in Ontario (RCDSO); at least weekly in most US states (CDC \/ AAMI ST79)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eD-value \/ Z-value\u003c\/td\u003e\n\u003ctd\u003eReported for every lot on the CoA — current lot: 2.0 min at 121 °C, Z-value 11.3 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003ctd\u003eCliniEco MDEL #35334\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"clini-prod-section\"\u003e \u003cdiv style=\"margin:24px 0;text-align:center;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/COA_ZJ1440_sample_nobrand_1500_a598cd3c-8b43-4c8e-853c-1f3464cfb05c.png?v=1792451616\" alt=\"Certificate of analysis for the 24-hour steam biological indicator (lot sample)\" style=\"max-width:100%;height:auto;border:1px solid #E5E7EB;border-radius:8px;\"\u003e\u003cp style=\"font-size:13px;color:#4B5563;margin-top:8px;\"\u003eSample CoA from a production lot — the certificate issued with your shipment carries your lot number and the manufacturer's details.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e✓ \u003cb\u003eG. stearothermophilus ATCC 7953\u003c\/b\u003e — the accepted steam sterilization challenge organism\u003c\/li\u003e \u003cli\u003e✓ \u003cb\u003e24-hour result\u003c\/b\u003e — results a day sooner than 48-hour vials\u003c\/li\u003e \u003cli\u003e✓ \u003cb\u003eSelf-contained (SCBI)\u003c\/b\u003e — ampoule and medium in one vial\u003c\/li\u003e \u003cli\u003e✓ \u003cb\u003eMonitoring record log template included\u003c\/b\u003e — supports RCDSO daily documentation and CDC \/ AAMI ST79\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv class=\"clini-prod-section\"\u003e \u003ch2\u003eCompliance\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eRCDSO (Ontario): a biological indicator for each sterilizer on every day that it is used — daily, per RCDSO IPAC standard 03\/24_5542\u003c\/li\u003e \u003cli\u003eCDC and AAMI ST79: spore test at least weekly per sterilizer (US baseline)\u003c\/li\u003e \u003cli\u003eTest organism: Geobacillus stearothermophilus ATCC 7953 (steam)\u003c\/li\u003e \u003cli\u003eDistributed by CliniEco Medical under MDEL #35334\u003c\/li\u003e \u003cli\u003eManufactured to EN ISO 11138-3 and EN ISO 11138-1 — documentation available on request\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv style=\"background:linear-gradient(135deg,#123a2f 0%,#206270 100%);border-radius:10px;padding:16px 18px;margin:14px 0;color:#fff;\"\u003e \u003ch3 style=\"margin:0;color:#fff;\"\u003eHardware is sold separately — buy only what you need\u003c\/h3\u003e \u003cp style=\"margin:8px 0 0;font-size:14px;opacity:.95;\"\u003eWe do not bundle hardware into a plan. Prices:\u003c\/p\u003e \u003cul style=\"margin:8px 0 0;padding-left:18px;font-size:14px;opacity:.95;\"\u003e \u003cli\u003e\n\u003cstrong\u003e24-Hour Dry-Block Incubator\u003c\/strong\u003e — $379\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eRapid Reader, 4-well fluorescence\u003c\/strong\u003e — $1,499 (3-hour results)\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"margin:8px 0 0;font-size:13px;opacity:.85;\"\u003eBoth include free printable record sheets. No lock-in — our BIs work in any standard 56–60 °C (58 ± 2 °C) incubator.\u003c\/p\u003e \u003ca href=\"\/en-us\/pages\/free-incubator\" style=\"display:inline-block;background:#fff;color:#123a2f;font-weight:700;padding:10px 22px;border-radius:8px;margin-top:12px;text-decoration:none;\"\u003eStart BI Plan — Reserve Your Free Device →\u003c\/a\u003e \u003c\/div\u003e \u003cdiv style=\"background:#f0f7f2;border:2px solid #123a2f;border-radius:8px;padding:10px 14px;margin:14px 0;\"\u003e \u003ch3 style=\"margin:0;color:#123a2f;\"\u003eCliniEco Service Promise\u003c\/h3\u003e \u003cul style=\"margin:8px 0 0;padding-left:18px;\"\u003e \u003cli\u003e\n\u003cstrong\u003eFree shipping on this 50-pack\u003c\/strong\u003e — anywhere in Canada\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eShips from our next production lot\u003c\/strong\u003e — dispatch date confirmed by email within one business day\u003c\/li\u003e \u003cli\u003e\u003cstrong\u003eCanadian-owned company\u003c\/strong\u003e\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBatch documentation available\u003c\/strong\u003e — CoA, D-value and spore count on request\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv class=\"clini-prod-section\"\u003e \n\u003cdiv class=\"ce-documents-module\"\u003e\n\u003ch2\u003eTechnical Documents\u003c\/h2\u003e\n\u003cp\u003eEverything below is on file for this product. Download what you need; the two documents we send individually are requested by batch so that what you receive matches the box in front of you.\u003c\/p\u003e\n\n  \u003cdiv class=\"ce-doc-row\"\u003e\n\u003cb\u003eProduct Data Sheet (PDS)\u003c\/b\u003e — full specifications, test organism, D-value, storage and stated limitations. \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CliniEco-BI-Technical-Data-Sheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload PDF →\u003c\/a\u003e\n\u003c\/div\u003e\n  \u003cdiv class=\"ce-doc-row\"\u003e\n\u003cb\u003eThird-Party Verification Summary\u003c\/b\u003e — report number, issuing laboratory, standards applied, result. \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CliniEco-BI-Third-Party-Verification-Summary-2p_8f85bf0d-9bf1-4939-a1c6-0a117e4b9c4b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload PDF →\u003c\/a\u003e\n\u003c\/div\u003e\n  \u003cdiv class=\"ce-doc-row\"\u003e\n\u003cb\u003eD-Value Report\u003c\/b\u003e — measured D-value at 121 °C. \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CliniEco-BI-D-Value-Report-24h-SCBI-24H-001.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload PDF →\u003c\/a\u003e\n\u003c\/div\u003e\n  \u003cdiv class=\"ce-doc-row\"\u003e\n\u003cb\u003e24-Month Stability Study\u003c\/b\u003e — real-time stability data behind the stated shelf life. \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CliniEco-BI-Stability-Study-24-Months.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload PDF →\u003c\/a\u003e\n\u003c\/div\u003e\n  \u003cdiv class=\"ce-doc-row\"\u003e\n\u003cb\u003eCertificate of Analysis\u003c\/b\u003e — issued for every batch we ship. \u003ca href=\"\/en-us\/pages\/technical-documents#request\"\u003eRequest by batch number →\u003c\/a\u003e\n\u003c\/div\u003e\n  \u003cdiv class=\"ce-doc-row\"\u003e\n\u003cb\u003eFull third-party laboratory report\u003c\/b\u003e (12 pages) — \u003ca href=\"\/en-us\/pages\/technical-documents#request\"\u003erequest\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cp class=\"ce-doc-cert\"\u003eManufactured by Chengdu QAMED Co., Ltd. (No.80 \u0026amp; 82 Jiangling Road, Xindu District, Chengdu, China; ISO 13485 certificate \u003cb\u003e280012038605752\u003c\/b\u003e, valid to 7 March 2029). Imported and distributed in Canada under Health Canada MDEL #35334.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/pages\/technical-documents\"\u003eAll technical documents →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eClinic \u0026amp; Volume Pricing\u003c\/h2\u003e \u003cp\u003eContact us for volume pricing — email alina@clinieco.ca.\u003c\/p\u003e \u003cul\u003e \u003cli\u003eVolume pricing for clinics, dental practices, LTC homes and distributors\u003c\/li\u003e \u003cli\u003eFree shipping on this item — anywhere in Canada\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv class=\"clini-prod-section\"\u003e \u003ch2\u003eWhy Buy CliniEco?\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e\n\u003cb\u003e24-hour results, with the per-test figure shown on this page\u003c\/b\u003e — a lower per-test figure than our 25-pack\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eCompliance built in\u003c\/b\u003e — the monitoring record log template supports RCDSO daily documentation and CDC \/ AAMI ST79 expectations\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eComplete reprocessing line\u003c\/b\u003e — pairs with CliniEco pouches, rolls, tape and cleaning solution\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eFull traceability\u003c\/b\u003e — factory documentation, batch CoA, Canadian import\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv class=\"clini-prod-section\"\u003e \u003cdiv class=\"clini-prod-section\"\u003e \u003ch2\u003eRelated Reading\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/spore-testing-for-dental-clinics-weekly-biological-indicator-protocol\"\u003eSpore Testing for Canadian Dental Clinics: Step by Step\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/what-to-do-when-a-biological-indicator-test-fails\"\u003eWhat to Do When a Biological Indicator Test Fails\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/geobacillus-stearothermophilus-the-science-behind-autoclave-spore-tests\"\u003eGeobacillus stearothermophilus: The Science Behind Autoclave Spore Tests\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003ch3\u003eRelated Guides\u003c\/h3\u003e\n\u003cp\u003eLearn how to choose and use this product correctly:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/sterility-assurance-level-sal-explained-what-10-6-means-for-sterilization\"\u003eSterility Assurance Level (SAL) Explained: What 10-6 Means for Sterilization\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/what-to-do-when-a-biological-indicator-test-fails\"\u003eBiological Indicator Failure: Recall, Root Cause, and Re-Test Protocol\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/class-4-vs-class-5-vs-class-6-sterilization-indicators-what-each-level-means\"\u003eClass 4 vs 5 vs 6 Sterilization Indicators: Which Do You Need?\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/how-often-should-you-run-a-spore-test-sterilizer-monitoring-schedules\"\u003eHow Often Should You Run a Spore Test? Sterilizer Monitoring Schedules\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003eFree Sterilization Log Sheet Generator — printable, no login\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e \u003cstyle\u003e.clini-prod { max-width:760px; margin:0 auto; font-family:-apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, sans-serif; color:#111827; }.clini-prod-hero { background:linear-gradient(135deg,#123a2f 0%,#206270 100%); border-radius:14px; padding:32px 28px; color:#fff; text-align:center; margin-bottom:24px; }.clini-prod-hero.clini-prod-title { font-size:26px; margin:0 0 8px; }.clini-prod-hero p { font-size:15px; opacity:.92; margin:4px 0; }.clini-prod-section { margin:24px 0; }.clini-prod-section h2 { font-size:18px; color:#123a2f; border-bottom:2px solid #E5E7EB; padding-bottom:8px; }.clini-prod-table { width:100%; border-collapse:collapse; margin:12px 0; }.clini-prod-table td { border:1px solid #E5E7EB; padding:10px 12px; font-size:14px; }.clini-prod-table td:first-child { background:#F9FAFB; font-weight:600; width:35%; }.clini-prod-note { background:#FFF7ED; border:1px solid #FDBA74; border-radius:8px; padding:12px 16px; font-size:13px; color:#7C2D12; margin:16px 0; }.clini-trust { background:#f8fafc; border:1px solid #d1d5db; border-radius:12px; padding:20px; margin:20px 0; }.clini-trust h3 { margin:0 0 12px; font-size:1.1rem; color:#123a2f; }.clini-trust-grid { display:grid; grid-template-columns:1fr 1fr; gap:12px; }.clini-trust-item { background:#fff; border:1px solid #e5e7eb; border-radius:8px; padding:12px; }.clini-trust-item h4 { margin:0 0 4px; font-size:0.95rem; color:#206270; }.clini-trust-item p { margin:0; font-size:13px; color:#4b5563; line-height:1.5; }.clini-cert-row { display:flex; flex-wrap:wrap; gap:8px; margin-top:12px; }.clini-cert-chip { background:#e8f1f5; color:#123a2f; border-radius:20px; padding:5px 14px; font-size:12.5px; font-weight:600; }\n\u003c\/style\u003e\n\u003c\/div\u003e\n\n\u003c!-- bi-family-crosslink v1 --\u003e\n\u003ch3\u003eRelated tests in this BI line\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-clinic-starter-bundle-gloves-spore-testing-sterilization-packaging\"\u003eClinic Starter Bundle — Gloves, Spore Testing \u0026amp; Sterilization Packaging\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-24-hour-biological-indicator-incubator-precision-dry-block-15-wells\"\u003eCliniEco 24-Hour Biological Indicator Incubator — Precision Dry-Block, 24 Wells\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-1-hour-rapid-readout-50-pack\"\u003eCliniEco Medical Biological Indicator — 1-Hour Rapid Readout, Fluorescence, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-20-minute-rapid-readout-50-pack\"\u003eCliniEco Medical Biological Indicator — 20-Minute Rapid Readout, Fluorescence, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-100-pack\"\u003eCliniEco Medical Biological Indicator — 24-Hour Self-Contained, 100-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003eCliniEco Medical Biological Indicator — 24-Hour Self-Contained, 25-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-3-hour-rapid-readout-fluorescence-50-pack\"\u003eCliniEco Medical Biological Indicator — 3-Hour Rapid Readout, Fluorescence, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/pages\/bi-sample-request\"\u003eFree Biological Indicator 5-Pack (clinics)\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-bowie-dick-test-pack-iso-11140-5-type-2-daily-vacuum-check-6-pack\"\u003eCliniEco Medical Bowie-Dick Test Pack — ISO 11140-5 Type 2, Daily Vacuum Check, 6-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-rapid-reader-4-well-fluorescence-biological-indicator-reader\"\u003eCliniEco Rapid Reader — 4-Well Fluorescence Biological Indicator Reader\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/sterilizer-testing-frequency-us-vs-canada-biological-indicator-ordering\"\u003eHow Often Must US vs Canadian Clinics Run Sterilizer Testing? Which Biological Indicator Pack to Order\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/what-is-a-biological-indicator-definition-organism-formats\"\u003eWhat Is a Biological Indicator? Definition, Core Organism, and Steam Autoclave Formats\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/iso-11138-5-low-temperature-steam-formaldehyde-indicators-canadian-buyers-guide\"\u003eISO 11138-5 Low-Temperature Steam Formaldehyde Indicators: A Canadian Buyer's Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/biological-indicator-price-canada-annual-spore-testing-cost-dental-clinic\"\u003eBiological Indicator Price in Canada: What a Year of Daily Spore Testing Costs a Dental Clinic\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow does daily monitoring in Canada compare with the weekly baseline in the United States?\u003c\/h2\u003e\n\u003cp\u003eThe interval is set where the clinic is, not by the indicator. In Ontario the requirement is a biological indicator for each sterilizer on every day that sterilizer is used, which is the RCDSO IPAC standard 03\/24_5542 wording; in most US states the floor is the CDC and AAMI ST79 baseline of at least weekly per sterilizer. The same 50-vial box covers a different length of calendar depending on which of those two regimes the room is under, so the frequency is the first question to settle before choosing a pack size.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eCanada (Ontario)\u003c\/th\u003e\n\u003cth\u003eUnited States\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTesting interval\u003c\/td\u003e\n\u003ctd\u003eA biological indicator for each sterilizer on every day it is used — daily\u003c\/td\u003e\n\u003ctd\u003eAt least weekly per sterilizer — the CDC \/ AAMI ST79 baseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhere the rule comes from\u003c\/td\u003e\n\u003ctd\u003eRCDSO IPAC standard 03\/24_5542\u003c\/td\u003e\n\u003ctd\u003eCDC guidance and AAMI ST79\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicators per test day\u003c\/td\u003e\n\u003ctd\u003eOne test vial plus one unexposed control from the same lot\u003c\/td\u003e\n\u003ctd\u003eOne test vial plus a control run on the day the test is done\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhat 50 vials covers\u003c\/td\u003e\n\u003ctd\u003eAbout 25 monitoring days — roughly one month of daily testing for one sterilizer\u003c\/td\u003e\n\u003ctd\u003eAbout 25 monitoring days — closer to six months at a weekly interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEffect on pack size\u003c\/td\u003e\n\u003ctd\u003eThe 50-pack sits between the 25 and the 100 because daily testing burns through stock\u003c\/td\u003e\n\u003ctd\u003eA 25-pack often covers a quarter or more, so the 50 and 100 packs suit multi-sterilizer rooms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord kept\u003c\/td\u003e\n\u003ctd\u003eDate, sterilizer, lot and result on the daily log\u003c\/td\u003e\n\u003ctd\u003eSame fields; the retention period follows the facility's own policy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTwo notes on that table, because a pack-size decision built on the wrong one costs a year of stock. First, Ontario is the province whose rule is quoted here; other provinces set their own monitoring intervals through their dental colleges, and a clinic outside Ontario should read the requirement it is actually inspected against. Second, the weekly interval is a floor and not a ceiling: an office that has had a failed test, a new sterilizer or a repaired unit will test more often for a period, and the box has to absorb that.\u003c\/p\u003e\n\n\u003ch2\u003eWhat has to be in place before the first test day?\u003c\/h2\u003e\n\u003cp\u003eA 50-pack on a shelf is not a monitoring programme. Three things sit around it, and a practice that buys the box without them ends up with a lot of vials and no usable record.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eWhat it has to be\u003c\/th\u003e\n\u003cth\u003eWhy the box alone will not do\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncubation\u003c\/td\u003e\n\u003ctd\u003eA dry-block incubator held at 56–60 °C (58 ± 2 °C)\u003c\/td\u003e\n\u003ctd\u003eThe vial is read at 24 hours at that temperature; there is no room-temperature route to the result\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositive control\u003c\/td\u003e\n\u003ctd\u003eOne unexposed vial from the same lot on each day of testing\u003c\/td\u003e\n\u003ctd\u003eIf the control does not turn yellow, the run is not valid and the day's result cannot be read as a pass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog\u003c\/td\u003e\n\u003ctd\u003eDate, sterilizer, lot code and result, written on the day\u003c\/td\u003e\n\u003ctd\u003eA test that is not written down cannot be produced at an audit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLot record\u003c\/td\u003e\n\u003ctd\u003eThe certificate that travels with the lot, filed against the lot code on the box\u003c\/td\u003e\n\u003ctd\u003eThe D-value and spore count are per lot, not per box size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFailure route\u003c\/td\u003e\n\u003ctd\u003eA written step for a yellow vial: quarantine the load, re-sterilize, re-test\u003c\/td\u003e\n\u003ctd\u003eThe result is only useful if the room already knows what it does with a fail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eHow should the vials be stored between test days?\u003c\/h2\u003e\n\u003cp\u003eStore the box between 15 and 30 °C at 30–65 % relative humidity, away from sterilants, direct sunlight and UV, and do not crush the packaging — a cracked vial is not a test. Shelf life is 24 months from the date of manufacture, and the expiry is printed on every vial rather than only on the carton, which is what lets a practice keep a part-used box on the shelf and still read the date off each vial it picks up.\u003c\/p\u003e\n\u003cp\u003eThe failure mode to design against is not heat but the utility room. A box that sits for a year next to a still-air autoclave, a chemical store or a window will be out of its stated storage band for most of that time, and the vials will look exactly the same as good ones. Keep the working box in the treatment area where the incubator is, and keep the spare box dry.\u003c\/p\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":48983807688926,"sku":"CLI-STER-BI-50","price":79.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/p50_01_main_1500_E2.jpg?v=1793459597","url":"https:\/\/clinieco.ca\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-50-pack","provider":"CliniEco Medical","version":"1.0","type":"link"}