{"product_id":"clinieco-medical-biological-indicator-1-hour-rapid-readout-50-pack","title":"CliniEco Medical Biological Indicator — 1-Hour Rapid Readout, Fluorescence, 50-Pack","description":"\u003cdiv style=\"border:1px solid #E5E7EB;border-radius:8px;padding:14px 16px;margin:0 0 18px;background:#F8FAFB\"\u003e\n\u003cstrong\u003eProof for this lot\u003c\/strong\u003e — D-value report (steam, 121 °C) · lot-level CoA on request · Health Canada MDEL #35334. \u003ca href=\"\/en-us\/pages\/sterilization-assurance\"\u003eHow we verify sterilization monitoring →\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eRapid-readout sterilization monitoring — results in 1 hour, not 24 hours.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eThe 1-hour vial answers a scheduling question, not a biological one: can this load go back into the chair before the day ends?\u003c\/strong\u003e Fifty self-contained vials (model ZJ60) arrive in one box, and every result is read on the \u003ca href=\"\/en-us\/products\/clinieco-rapid-reader-4-well-fluorescence-biological-indicator-reader\"\u003eCliniEco Rapid Reader\u003c\/a\u003e at 58 ± 2 °C — there is no colour change to read by eye.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/24-hour-self-contained-biological-indicator-pack-sizes-incubation-record\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/1h_01_main_1500_E.jpg?v=1793457254\" alt=\"CliniEco Medical Biological Indicator — 1-Hour Rapid Readout, Fluorescence, 50-Pack\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eWhich sterilizer cycles can a 1-hour biological indicator be used in?\u003c\/h2\u003e\n\u003cp\u003eVacuum and gravity cycles both, on saturated steam at the three temperatures a Canadian clinic actually runs: 121 °C, 132 °C and 134 °C. The vial carries \u003cem\u003eGeobacillus stearothermophilus\u003c\/em\u003e ATCC 7953 at a population of at least 1.0 × 10⁶ c.f.u. with a D-value of at least 1.5 minutes at 121 °C, and it incubates at 58 ± 2 °C. The organism and the reference standards — ISO 11138-1 and ISO 11138-3 — are the same as our 24-hour line, so one sterilizer can run both tiers without splitting the monitoring programme or the logbook format. What changes is the wait, not the organism or the cycle it monitors.\u003c\/p\u003e\n\u003ch2\u003eHow long does the 1-hour result take, and when can the load go back into use?\u003c\/h2\u003e\n\u003cp\u003eSixty minutes from activation, with no overnight hold and no second visit. In practice: run the cycle, activate the vial, read it at the hour mark, and release the load if the result is negative. A positive result is a failed load and it stays failed — re-clean, re-pack, re-sterilize, and look at the sterilizer before it runs again. One indicator per load, every day the sterilizer runs, placed where steam is hardest to reach: in a dental load that means inside the pouch or cassette, not loose in the chamber.\u003c\/p\u003e\n\u003ch2\u003eWhat does the 1-hour tier cost per sterilization day, and how far does one box go?\u003c\/h2\u003e\n\u003cp\u003eA box of 50 vials, priced on this page, works out to a per-test figure by dividing the box amount by fifty. Monitoring that follows the pattern in RCDSO Standard 5542 for Ontario dental practices uses a test plus a control on each day the sterilizer runs, so a sterilization day consumes two vials and one box covers 25 such days. Per-day cost decides a tier: the 24-hour self-contained vial costs less per day, the 3-hour fluorescence vial sits below this tier per day, and the 20-minute vial sits above it.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReadout tier by release window — cost per sterilization day and box to order (CAD)\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eRelease window\u003c\/th\u003e\n\u003cth\u003eTier that fits\u003c\/th\u003e\n\u003cth\u003eCost per sterilization day\u003c\/th\u003e\n\u003cth\u003eBox to order\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet must return to the chair in the same session\u003c\/td\u003e\n\u003ctd\u003e20 minutes, reader required\u003c\/td\u003e\n\u003ctd\u003eDivide the box amount by the vials in the box\u003c\/td\u003e\n\u003ctd\u003e50 vials, $289.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad released before the working day ends\u003c\/td\u003e\n\u003ctd\u003e1 hour, reader required — this listing\u003c\/td\u003e\n\u003ctd\u003eDivide the box amount by the vials in the box\u003c\/td\u003e\n\u003ctd\u003e50 vials, $269.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelease after the morning list\u003c\/td\u003e\n\u003ctd\u003e3 hours, reader required\u003c\/td\u003e\n\u003ctd\u003eDivide the box amount by the vials in the box\u003c\/td\u003e\n\u003ctd\u003e50 vials, $249.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelease next morning, low volume\u003c\/td\u003e\n\u003ctd\u003e24 hours, colour change by eye\u003c\/td\u003e\n\u003ctd\u003eDivide the box amount by the vials in the box\u003c\/td\u003e\n\u003ctd\u003e50 vials, $109.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelease next morning, several cycles a day\u003c\/td\u003e\n\u003ctd\u003e24 hours, 100-vial box\u003c\/td\u003e\n\u003ctd\u003eDivide the box amount by the vials in the box\u003c\/td\u003e\n\u003ctd\u003e100 vials, $189.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOccasional testing, small practice\u003c\/td\u003e\n\u003ctd\u003e24 hours, 25-vial box\u003c\/td\u003e\n\u003ctd\u003eDivide the box amount by the vials in the box\u003c\/td\u003e\n\u003ctd\u003e25 vials, $69.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eWhere the figure meets the logbook.\u003c\/strong\u003e The vial lot number goes against the load on the day of the test; the printable daily record on the \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003ecompliance log centre\u003c\/a\u003e has a column for it, and the \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003ecompliance desk\u003c\/a\u003e will answer a written question about your own sterilizer where the standard you follow reads differently. If you would rather work the number from your own case mix, the \u003ca href=\"\/en-us\/pages\/clinic-supply-planner\"\u003eclinic supply planner\u003c\/a\u003e multiplies sterilizer days by vials per day. Related tiers: \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-3-hour-rapid-readout-fluorescence-50-pack\"\u003e3-hour fluorescence 50-pack\u003c\/a\u003e and \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-50-pack\"\u003e24-hour self-contained 50-pack\u003c\/a\u003e. CliniEco Medical supplies this line under MDEL #35334.\u003c\/p\u003e\n\u003cp\u003eEach vial contains \u003cem\u003eGeobacillus stearothermophilus\u003c\/em\u003e ATCC 7953 spores in a self-contained format. After the sterilization cycle the vial is activated and incubated, and the result is read by \u003cstrong\u003efluorescence\u003c\/strong\u003e — a positive (failed) and negative (passed) result is reported by the reader, not by eye.\u003c\/p\u003e\n\n\u003ch3\u003eHow it differs from our 24-hour indicator\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReadout: 1 hour\u003c\/strong\u003e instead of 24 hours\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReader required\u003c\/strong\u003e — this model is read on the CliniEco Rapid Reader (4-well fluorescence reader). It is not a colour-change product, so it cannot be interpreted visually.\u003c\/li\u003e\n\u003cli\u003eSame spore strain and same ISO reference as our 24-hour line, so both can sit in one monitoring programme.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZJ60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReadout time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-contained vial, rapid readout (enzymatic \/ fluorescence)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrganism\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cem\u003eGeobacillus stearothermophilus\u003c\/em\u003e ATCC 7953\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO 11138-1 and ISO 11138-3, moist heat (per manufacturer specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncubation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e58 ± 2 °C (use with the CliniEco Rapid Reader)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePack size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 vials per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntended use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoutine monitoring of steam (moist heat) sterilization cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFollow the manufacturer's instructions supplied with the box; keep the vials in their original packaging and do not add any label or tape to the vial or cap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eReadout times across our biological indicator line\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eReadout\u003c\/th\u003e\n\u003cth\u003eResult read by\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRapid 20 minutes (ZJ20)\u003c\/td\u003e\n\u003ctd\u003e20 minutes\u003c\/td\u003e\n\u003ctd\u003eCliniEco Rapid Reader\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRapid 1 hour (ZJ60)\u003c\/td\u003e\n\u003ctd\u003e1 hour\u003c\/td\u003e\n\u003ctd\u003eCliniEco Rapid Reader\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRapid 3 hours (ZJ180)\u003c\/td\u003e\n\u003ctd\u003e3 hours\u003c\/td\u003e\n\u003ctd\u003eCliniEco Rapid Reader\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24-hour self-contained (ZJ1440)\u003c\/td\u003e\n\u003ctd\u003eUp to 24 hours (early read at 8 \/ 12 h)\u003c\/td\u003e\n\u003ctd\u003eVisual colour change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePrice per test, and when the 1-hour tier is worth it\u003c\/h3\u003e\n\u003cp\u003eEach of the three fluorescence 50-packs is priced on its own page, and the per-test figure follows there by dividing the box amount by fifty. Against the 20-minute tier this one costs less per test; against the 3-hour tier it costs more. Over 240 tests (two indicators per test day, 120 test days) the gap between adjacent tiers stays small enough that readout speed, not price, is the reason to move up or down a tier.\u003c\/p\u003e\n\u003cp\u003eThis is the tier for a load that has to be released inside the working session, but not inside the half hour: a normal clinic day of two or three cycles, or a shared reader where a 20-minute read would hold up the queue. If results can wait until the end of the day, the 3-hour indicator is cheaper; if the instruments are needed back immediately, the 20-minute one is faster.\u003c\/p\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eDental clinics, medical clinics and laboratories that run daily steam sterilization and need a same-day, documented result — for example where a load cannot be released until the biological indicator reads negative.\u003c\/p\u003e\n\n\u003ch3\u003eWhat you need with it\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCliniEco Rapid Reader — 4-well fluorescence reader (required for this model)\u003c\/li\u003e\n\u003cli\u003eIncubation at 58 ± 2 °C\u003c\/li\u003e\n\u003cli\u003eBatch record: record the vial lot number against the sterilizer load\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDocumentation\u003c\/h3\u003e\n\u003cp\u003eManufacturer's instructions for use are supplied with every box. A certificate of analysis per batch is available on request — the lot number on the box is traceable to the release documentation.\u003c\/p\u003e\n\u003ch3\u003eHow to run a test\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePlace the indicator in the load, in the area that is hardest to sterilize (for a typical dental load: with the instruments in the pouch or cassette).\u003c\/li\u003e\n\u003cli\u003eRun the sterilization cycle as normal.\u003c\/li\u003e\n\u003cli\u003eAfter the cycle, follow the vial activation step described in the manufacturer's instructions — the vial is activated, then incubated.\u003c\/li\u003e\n\u003cli\u003ePlace the vial in the CliniEco Rapid Reader and incubate at 58 ± 2 °C. The reader reports the result at the readout time above.\u003c\/li\u003e\n\u003cli\u003eRecord the result and the vial lot number against the sterilizer load log.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eOne indicator per load, every day.\u003c\/strong\u003e Do not add any label or tape to the vial or its cap — it interferes with the incubation and read.\u003c\/p\u003e\n\n\u003ch3\u003eInterpreting the result\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNegative (pass)\u003c\/strong\u003e — the spores were killed; the load may be released.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePositive (fail)\u003c\/strong\u003e — spores survived. Do not release the load: re-clean, re-pack and re-sterilize, and check the sterilizer before using it again. Retain the indicator and the load record.\u003c\/li\u003e\n\u003cli\u003eThis model is read by the reader only. Unlike our 24-hour indicator, there is no colour change to read by eye — the result must come from the reader.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOfficial manufacturer specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReadout time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncubation range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15–60 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrganism\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cem\u003eGeobacillus stearothermophilus\u003c\/em\u003e ATCC 7953\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePopulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 1.0 × 10⁶ c.f.u. (mean per strip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD-value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 1.5 min at 121 °C (steam)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest conditions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e121 °C \/ 132 °C \/ 134 °C saturated steam — vacuum and gravity cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO 11138-1 and ISO 11138-3 compliant (manufacturer declaration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePack size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 vials per pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency of use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne test per sterilization cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKit contents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBI ampoules and culture media tubes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eParameters as published by the manufacturer. Batch certificate of analysis is traceable from the lot number on the box.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003c!-- bi-family-crosslink v1 --\u003e\n\n\u003cp\u003e\u003cstrong\u003eHave a question about your own facility?\u003c\/strong\u003e Send it in and you will get a written answer specific to your setup, with the regulation or standard it is based on cited. \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003eAsk your compliance question\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eRelated tests in this BI line\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-clinic-starter-bundle-gloves-spore-testing-sterilization-packaging\"\u003eClinic Starter Bundle — Gloves, Spore Testing \u0026amp; Sterilization Packaging\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-24-hour-biological-indicator-incubator-precision-dry-block-15-wells\"\u003eCliniEco 24-Hour Biological Indicator Incubator — Precision Dry-Block, 24 Wells\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-20-minute-rapid-readout-50-pack\"\u003eCliniEco Medical Biological Indicator — 20-Minute Rapid Readout, Fluorescence, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-100-pack\"\u003eCliniEco Medical Biological Indicator — 24-Hour Self-Contained, 100-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003eCliniEco Medical Biological Indicator — 24-Hour Self-Contained, 25-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-50-pack\"\u003eCliniEco Medical Biological Indicator — 24-Hour Self-Contained, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-3-hour-rapid-readout-fluorescence-50-pack\"\u003eCliniEco Medical Biological Indicator — 3-Hour Rapid Readout, Fluorescence, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/pages\/bi-sample-request\"\u003eFree Biological Indicator 5-Pack (clinics)\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-bowie-dick-test-pack-iso-11140-5-type-2-daily-vacuum-check-6-pack\"\u003eCliniEco Medical Bowie-Dick Test Pack — ISO 11140-5 Type 2, Daily Vacuum Check, 6-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-rapid-reader-4-well-fluorescence-biological-indicator-reader\"\u003eCliniEco Rapid Reader — 4-Well Fluorescence Biological Indicator Reader\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/how-to-choose-biological-indicator-incubator-canadian-clinic\"\u003eHow to Choose a Biological Indicator Incubator for a Canadian Clinic\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/how-often-us-vs-canadian-clinics-sterilizer-testing-incubator-guide\"\u003eHow Often Must US vs Canadian Clinics Run Sterilizer Testing? 24-Hour Biological Indicator Incubator Ordering \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/which-standards-medical-biological-indicator-us-vs-canada\"\u003eWhich Standards Apply to Medical Biological Indicator in the US vs Canada? Sizes and Sourcing\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/which-standards-medical-bowie-dick-test-pack-us-vs-canada\"\u003eWhich Standards Apply to Medical Bowie-Dick Test Pack in the US vs Canada? Sizes and Sourcing\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"ce-documents-module\"\u003e\n\u003ch2\u003eTechnical Documents\u003c\/h2\u003e\n\u003cp\u003eEverything below is on file for this product. Download what you need; the two documents we send individually are requested by batch so that what you receive matches the box in front of you.\u003c\/p\u003e\n\n  \u003cdiv class=\"ce-doc-row\"\u003e\n\u003cb\u003eProduct Data Sheet (PDS)\u003c\/b\u003e — full specifications, test organism, D-value, storage and stated limitations. \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CliniEco-BI-Technical-Data-Sheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload PDF →\u003c\/a\u003e\n\u003c\/div\u003e\n  \u003cdiv class=\"ce-doc-row\"\u003e\n\u003cb\u003eThird-Party Verification Summary\u003c\/b\u003e — report number, issuing laboratory, standards applied, result. \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CliniEco-BI-Third-Party-Verification-Summary-2p_8f85bf0d-9bf1-4939-a1c6-0a117e4b9c4b.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload PDF →\u003c\/a\u003e\n\u003c\/div\u003e\n  \u003cdiv class=\"ce-doc-row\"\u003e\n\u003cb\u003eD-Value Report\u003c\/b\u003e — measured D-value at 121 °C. \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CliniEco-BI-D-Value-Report-Rapid-SCBI-RAPID-001.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload PDF →\u003c\/a\u003e\n\u003c\/div\u003e\n  \u003cdiv class=\"ce-doc-row\"\u003e\n\u003cb\u003e24-Month Stability Study\u003c\/b\u003e — real-time stability data behind the stated shelf life. \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CliniEco-BI-Stability-Study-24-Months.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload PDF →\u003c\/a\u003e\n\u003c\/div\u003e\n  \u003cdiv class=\"ce-doc-row\"\u003e\n\u003cb\u003eCertificate of Analysis\u003c\/b\u003e — issued for every batch we ship. \u003ca href=\"\/en-us\/pages\/technical-documents#request\"\u003eRequest by batch number →\u003c\/a\u003e\n\u003c\/div\u003e\n  \u003cdiv class=\"ce-doc-row\"\u003e\n\u003cb\u003eFull third-party laboratory report\u003c\/b\u003e (12 pages) — \u003ca href=\"\/en-us\/pages\/technical-documents#request\"\u003erequest\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cp class=\"ce-doc-cert\"\u003eManufactured by Chengdu QAMED Co., Ltd. (No.80 \u0026amp; 82 Jiangling Road, Xindu District, Chengdu, China; ISO 13485 certificate \u003cb\u003e280012038605752\u003c\/b\u003e, valid to 7 March 2029). Imported and distributed in Canada under Health Canada MDEL #35334.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/pages\/technical-documents\"\u003eAll technical documents →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":49116635005150,"sku":"CLI-STER-BI-R60-50","price":192.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/1h_01_main_1500_E.jpg?v=1793457254","url":"https:\/\/clinieco.ca\/en-us\/products\/clinieco-medical-biological-indicator-1-hour-rapid-readout-50-pack","provider":"CliniEco Medical","version":"1.0","type":"link"}