{"product_id":"clinieco-breast-pump-replacement-parts","title":"CliniEco Breast Pump \u0026 Replacement Parts — Flanges, Valves, Bottles","description":"\u003cp\u003e\u003cstrong\u003eElectric breast pump with replaceable parts\u003c\/strong\u003e — keep suction strong.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMultiple flange sizes for a comfortable fit\u003c\/li\u003e\n\u003cli\u003eValves, diaphragms and bottles available separately\u003c\/li\u003e\n\u003c\/ul\u003e\u003c!-- spec-align-20260919 --\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e \u003cstrong\u003eDevice:\u003c\/strong\u003e Electric breast pump (single or double pumping), rechargeable, multiple suction levels\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eAccessories (refillable):\u003c\/strong\u003e Flanges (multiple sizes) \/ valves \/ diaphragms \/ bottles \/ milk storage bags\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003ePackaging:\u003c\/strong\u003e Colour box with main unit and standard accessories; accessories packed separately\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eFull specification sheet available on request for institutional orders.\u003c\/em\u003e\u003c\/p\u003e\n\u003csection class=\"clinieco-answers\"\u003e\n\u003ch2\u003eWhich breast pump parts wear out first?\u003c\/h2\u003e\n\u003cp\u003eThe valves and membranes go first, then the flanges and the bottles. The signs are the same in every case: suction that feels weaker than it did, milk drawn back toward the tubing, or a flange that no longer seals against the breast. Parts are consumables; the pump motor is the durable part of the system. A clinic that stocks spares shortens the gap between a failing valve and a parent giving up on pumping.\u003c\/p\u003e\n\u003ch2\u003eHow do I choose the right flange size?\u003c\/h2\u003e\n\u003cp\u003eMeasure the nipple diameter at the base and add roughly two to four millimetres to arrive at the tunnel size. A flange that is too small rubs; one that is too large pulls areola into the tunnel. Sizes commonly run from 21 mm to 30 mm, with 24 mm the size most pumps are supplied with. Fit is the most common reason pumping becomes uncomfortable.\u003c\/p\u003e\n\u003ch2\u003eHow should parts be cleaned between sessions?\u003c\/h2\u003e\n\u003cp\u003eRinse in cool water first so milk protein does not set, wash in hot soapy water with a brush kept for the purpose, and sanitise on the schedule the pump manufacturer states. Tubing is not meant to be washed — if milk reaches the tubing, the manufacturer's instruction is to replace it rather than to dry it out and carry on.\u003c\/p\u003e\n\u003ch2\u003eWhat should a clinic confirm about compatibility?\u003c\/h2\u003e\n\u003cp\u003eParts are model-specific. Before a clinic stocks replacement flanges or valves, confirm the pump model and the part number that goes with it, because a valve that looks similar can change the suction profile. This page lists flanges, valves, diaphragms, bottles and storage bags as refillable accessories; the model match is what makes them work. Keep the model number on the parts bin label, not only in the purchasing system.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003ePackaging \/ unit\u003c\/th\u003e\n\u003cth\u003eWear sign\u003c\/th\u003e\n\u003cth\u003eReplacement interval\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve and membrane\u003c\/td\u003e\n\u003ctd\u003eSold as a set\u003c\/td\u003e\n\u003ctd\u003eSuction weaker than before\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlange\u003c\/td\u003e\n\u003ctd\u003eMultiple sizes, per piece\u003c\/td\u003e\n\u003ctd\u003eLoss of seal, rubbing\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiaphragm\u003c\/td\u003e\n\u003ctd\u003ePer piece\u003c\/td\u003e\n\u003ctd\u003eMilk pulled toward tubing\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBottle and storage bag\u003c\/td\u003e\n\u003ctd\u003eBottle per piece, bags per pack\u003c\/td\u003e\n\u003ctd\u003eCracks, clouding\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eClinic and home-care enquiries: \u003ca href=\"\/en-us\/pages\/wholesale\"\u003einstitutional account enquiry page\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eLast reviewed: 2026-11\u003c\/em\u003e\u003c\/p\u003e\u003c\/section\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Single","offer_id":49082005192926,"sku":"CLI-BP-PARTS","price":178.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/clinieco-breast-pump-hero.jpg?v=1794954182","url":"https:\/\/clinieco.ca\/en-us\/products\/clinieco-breast-pump-replacement-parts","provider":"CliniEco Medical","version":"1.0","type":"link"}