{"product_id":"clinieco-benchtop-autoclave-class-b-coming-soon","title":"Benchtop Autoclave (Class B Steam Sterilizer) — Coming Soon","description":"\u003cdiv class=\"product-description\"\u003e\n\u003ch2\u003eWhat does a Class B pre-vacuum cycle change for a clinic?\u003c\/h2\u003e\n\u003cp\u003eA gravity cycle pushes steam in and lets air out; a pre-vacuum cycle pulls air out first, which is what allows wrapped, hollow and porous loads to be sterilised reliably. That is why Class B benchtop units are the format dental clinics, veterinary practices, med-spas and tattoo studios look at: the loads those rooms actually run are wrapped and hollow, not open instruments on a tray.\u003c\/p\u003e\n\u003ch2\u003eWhat has to be true before a benchtop unit goes into service?\u003c\/h2\u003e\n\u003cp\u003eThree things, and none of them are optional: the unit has to be validated for the load types the clinic runs, the monitoring schedule has to be in place from the first cycle, and the records have to survive an inspection. In Ontario, the dental regulator's infection-control standard sets the expectation for sterilisation monitoring; the practical version is a biological indicator on every day the unit runs, plus chemical indicators in every pack and a record of both.\u003c\/p\u003e\n\u003ch2\u003eWhere does this unit sit in that programme?\u003c\/h2\u003e\n\u003cp\u003eIt does not publish chamber volume, cycle times or the licensing position, and a clinic should not plan an equipment replacement around a date that has not been confirmed. What can be done now is the part that takes longer than the purchase: the monitoring routine and the record keeping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFormat:\u003c\/strong\u003e Benchtop steam steriliser, pre-vacuum Class B cycle\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLoad types:\u003c\/strong\u003e Wrapped, hollow and porous loads\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntended settings:\u003c\/strong\u003e Dental clinics, veterinary practices, med-spas, tattoo studios\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMonitoring expectation:\u003c\/strong\u003e Biological indicator each day the unit runs, chemical indicator in every pack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDistribution:\u003c\/strong\u003e CliniEco Medical — MDEL #35334\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFormat:\u003c\/strong\u003e Benchtop steam steriliser, pre-vacuum Class B cycle\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLoad types:\u003c\/strong\u003e Wrapped, hollow and porous loads\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntended settings:\u003c\/strong\u003e Dental clinics, veterinary practices, med-spas, tattoo studios\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMonitoring expectation:\u003c\/strong\u003e Biological indicator each day the unit runs, chemical indicator in every pack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDistribution:\u003c\/strong\u003e CliniEco Medical — MDEL #35334\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eBenchtop steam steriliser — planned specification as listed\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003ePlanned \/ stated\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eBenchtop steam steriliser, pre-vacuum Class B cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad types\u003c\/td\u003e\n\u003ctd\u003eWrapped, hollow and porous loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended settings\u003c\/td\u003e\n\u003ctd\u003eDental clinics, veterinary practices, med-spas, tattoo studios\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChamber volume\u003c\/td\u003e\n\u003ctd\u003eNot stated on the listing — confirmed before release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCycle times\u003c\/td\u003e\n\u003ctd\u003eNot stated on the listing — confirmed before release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring expectation\u003c\/td\u003e\n\u003ctd\u003eBiological indicator each day the unit runs, chemical indicator in every pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003ctd\u003eCliniEco Medical — MDEL #35334\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhat does the monitoring programme need on the shelf?\u003c\/h2\u003e\n\u003cp\u003eA \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-50-pack\"\u003e24-hour self-contained biological indicator, fifty per pack\u003c\/a\u003e covers daily spore testing, and a \u003ca href=\"\/en-us\/products\/clinieco-medical-bowie-dick-test-pack-iso-11140-5-type-2-daily-vacuum-check-6-pack\"\u003eBowie-Dick test pack to ISO 11140-5 Type 2\u003c\/a\u003e is the daily vacuum check a pre-vacuum unit needs before the first load. For packaging, the \u003ca href=\"\/en-us\/products\/clinieco-sterilization-pouch-class-4-self-sealing-dual-indicator-200-per-box\"\u003eClass 4 self-sealing pouch with dual indicators, two hundred per box\u003c\/a\u003e is the consumable that keeps the routine running. Log sheets print from the \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003ecompliance log centre\u003c\/a\u003e and can be generated with the sterilization log generator on that page; clinic quantities are quoted at \u003ca href=\"\/en-us\/pages\/wholesale\"\u003ethe clinic ordering desk\u003c\/a\u003e, and the monitoring question itself can be booked with \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003ethe compliance desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eImported and distributed in Canada by CliniEco Medical — MDEL #35334.\u003c\/p\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eCliniEco Medical is preparing to introduce a \u003cstrong\u003ebenchtop Class B steam sterilizer (autoclave)\u003c\/strong\u003e for Canadian dental clinics, veterinary practices, med-spas, and tattoo studios. Class B pre-vacuum technology delivers validated sterilization for wrapped, hollow, and porous loads — the same standard trusted by modern clinics.\u003c\/p\u003e\n\u003ch2\u003eWhy Wait for Our Autoclave?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance-first\u003c\/strong\u003e — sourced from manufacturers holding Canadian Medical Device Licence (Class II) and FDA 510(k) clearance; distributed by CliniEco Medical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne-stop sterilization room\u003c\/strong\u003e — pairs with our sterilization pouches, rolls, Class 4\/5 indicators, biological indicators (BI) and monitoring equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal support\u003c\/strong\u003e — Toronto warehouse, Canadian-based distributor, full documentation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen consumables ecosystem\u003c\/strong\u003e — works with standard sterilization pouches\/tape\/BI on the market (no lock-in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAvailability\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWe are currently completing model selection and sample validation. Expected retail range CAD $3,500–$4,500 depending on model (final pricing TBD at launch).\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo be notified at launch or to discuss bulk\/group pricing for multi-chair clinics, contact us at \u003ca href=\"mailto:alina@clinieco.ca\"\u003ealina@clinieco.ca\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- sterilization-system-links --\u003e\n\u003cdiv style=\"max-width:820px;margin:28px auto 8px;padding:16px 20px;border:1px solid #e2e8f0;border-radius:12px;background:#f8fafc\"\u003e\n\u003cp style=\"margin:0 0 10px;font-weight:700;color:#206270;font-size:15px\"\u003ePart of the same sterilization system\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px;line-height:1.9;font-size:15px;color:#334155\"\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003e24-Hour Biological Indicators — 25-Pack\u003c\/a\u003e — $69.99\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-us\/products\/clinieco-24-hour-biological-indicator-incubator-precision-dry-block-15-wells\"\u003e24-Hour BI Incubator — Dry-Block\u003c\/a\u003e — $379.00\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-us\/products\/clinieco-sterilization-pouch-class-4-self-sealing-dual-indicator-200-per-box\"\u003eSterilization Pouches — Class 4, Assorted 200-Pack\u003c\/a\u003e — $11.99 (case of 10 — $95.92)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/which-benchtop-autoclave-class-b-british-columbia-spd\"\u003eWhich Benchtop Autoclave (Class B Steam Sterilizer) Do Hospital Sterile Processing Departments in British Colu\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/iso-15882-chemical-indicator-selection-storage-reading\"\u003eISO 15882 in Practice: Selecting, Storing and Reading Chemical Indicators\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":48987217723614,"sku":"CLI-AUTOCLAVE-CB-COMING","price":2844.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/01_main_white_clean_c8ce08af-0c80-47fc-a177-7bb5de0f203a.jpg?v=1791271772","url":"https:\/\/clinieco.ca\/en-us\/products\/clinieco-benchtop-autoclave-class-b-coming-soon","provider":"CliniEco Medical","version":"1.0","type":"link"}