{"title":"Autoclave \u0026 Ultrasonic Equipment","description":"\u003cp\u003eThe sterilization room is three jobs on one bench: cleaning an instrument before anything is packed, sealing the pack, and proving afterwards that the cycle it went through actually worked. This page covers the units that do those three jobs - the ultrasonic tank, the constant-heat sealer, the incubator and the indicator reader - plus the consumables each one depends on. Packaging sits under \u003ca href=\"\/en-us\/collections\/sterilization-pouches\"\u003esterilization pouches\u003c\/a\u003e and the tests sit under \u003ca href=\"\/en-us\/collections\/sterilization-monitoring\"\u003eautoclave monitoring and spore testing\u003c\/a\u003e. The sterilizer itself is not sold here: the Class B benchtop unit on our site is a pre-launch listing, not a purchasable model, so nothing on this page assumes you are buying an autoclave from us.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eShort answer:\u003c\/strong\u003e a single-surgery dental clinic, veterinary practice or med-spa running one autoclave needs a 6 L ultrasonic tank that takes a full instrument cassette, a 12 mm constant-heat pouch sealer, and a dry-block incubator for 24-hour spore tests. Add a 4-well fluorescence reader only if the daily test is a 20-minute, 1-hour or 3-hour rapid-readout indicator. Cycle volume decides the size, not the catalogue.\u003c\/p\u003e\n\n\u003ch2\u003eHow many cycles a week does the room actually run?\u003c\/h2\u003e\n\u003cp\u003eCount it before ordering anything, because the count sets the tank, the block and the number of spare wells. The arithmetic that survives an inspection is simple: cycles per day, multiplied by days the autoclave runs, gives the number of packs that have to be sealed and the number of indicator wells that get filled.\u003c\/p\u003e\n\u003cp\u003eTake a four-chair dental clinic that runs the autoclave four times a day, five days a week. That is twenty cycles and twenty packs to seal, and at one biological indicator per sterilizer per monitoring day it is twenty wells filled in a week. Run six days and the figure climbs to twenty-four. A 20-well dry block - the \u003ca href=\"\/en-us\/products\/dlab-hb120-s-led-digital-dry-bath-incubator\"\u003eHB105-S1 dry-bath incubator\u003c\/a\u003e - is then full with no room left for the re-test after a failed indicator, which is the seat you only need on the week you need it badly. Two sterilizers, or a second suite in the same building, is where a block with spare capacity stops being optional.\u003c\/p\u003e\n\u003cp\u003eThe cleaning side counts differently. A 6 L ultrasonic tank holds one full instrument cassette per cycle, because the tank floor is 31.1 by 17.2 cm - the footprint a standard cassette needs. If your instruments arrive loose instead of in a cassette, you are either unpacking them onto the basket or running two cycles, and that is the point at which a second tank or a longer working day becomes the cheaper decision. The \u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003eCS6.2 6 L dual-frequency cleaner\u003c\/a\u003e is sized around that single-cassette cycle: 32 kHz for heavier soil, 48 kHz to reach lumens and threaded joints, with a 120-second degas at the start of the run so the first load is not fighting a head of air.\u003c\/p\u003e\n\n\u003ch2\u003eWhich configuration fits a one-chair practice, a four-chair clinic, or a building with two sterilizers?\u003c\/h2\u003e\n\u003cp\u003eThe table below is the same decision, stated three ways. Read across the row that matches your cycle count rather than the row that matches your ambition - the units are not upgradable after the fact, and buying a size up usually means a tank that sits half loaded.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eRoom profile\u003c\/th\u003e\n\u003cth\u003eCycles per day\u003c\/th\u003e\n\u003cth\u003eCleaning\u003c\/th\u003e\n\u003cth\u003eSealing\u003c\/th\u003e\n\u003cth\u003eIncubation and readout\u003c\/th\u003e\n\u003cth\u003eWhy this row\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle surgery (solo dental, vet, med-spa, tattoo studio)\u003c\/td\u003e\n\u003ctd\u003e1-4\u003c\/td\u003e\n\u003ctd\u003e6 L tank, \u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003emulti-enzyme concentrate\u003c\/a\u003e at 1:400\u003c\/td\u003e\n\u003ctd\u003e12 mm \u003ca href=\"\/en-us\/products\/clinieco-constant-heat-pouch-sealer-200-c-12mm-seal-110v-dental-sterilization\"\u003econstant-heat sealer\u003c\/a\u003e, or self-sealing pouches if every pack fits a stocked size\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en-us\/products\/dlab-hb120-s-led-digital-dry-bath-incubator\"\u003e20-well dry block\u003c\/a\u003e plus 24-hour spore tests\u003c\/td\u003e\n\u003ctd\u003eOne cassette per cycle; one indicator well per operating day leaves seats to spare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-chair clinic (4-8 chairs, one autoclave)\u003c\/td\u003e\n\u003ctd\u003e6-10\u003c\/td\u003e\n\u003ctd\u003eSame 6 L tank run back to back; solution bought by the larger pack\u003c\/td\u003e\n\u003ctd\u003eSealer in continuous operation after a 2-3 minute pre-heat\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en-us\/products\/clinieco-24-hour-biological-indicator-incubator-precision-dry-block-15-wells\"\u003e24-hour block with USB data export\u003c\/a\u003e, or a second 20-well block\u003c\/td\u003e\n\u003ctd\u003eWells run out before the tank does; export replaces a hand-copied temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilding with two sterilizers, or a suite per floor\u003c\/td\u003e\n\u003ctd\u003e10+\u003c\/td\u003e\n\u003ctd\u003eOne tank per reprocessing room, not one tank shared between floors\u003c\/td\u003e\n\u003ctd\u003eSecond sealer only if both rooms pack separately\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"\/en-us\/products\/clinieco-rapid-reader-4-well-fluorescence-biological-indicator-reader\"\u003e4-well fluorescence reader\u003c\/a\u003e if the daily test is rapid-readout\u003c\/td\u003e\n\u003ctd\u003eBIs are counted per unit per day, so the block and the reader both double\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhat are the specifications, compatibility limits and shipping format of each unit?\u003c\/h2\u003e\n\u003cp\u003eEvery figure below is the one an order turns on: the seal width that decides whether a pack peels cleanly, the well diameter that decides whether an ampoule seats flush, and whether the unit leaves as a single bench machine or a case pack. Consumables are separate lines throughout - the tank does not ship with solution, the reader does not ship with ampoules.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit\u003c\/th\u003e\n\u003cth\u003eKey specification\u003c\/th\u003e\n\u003cth\u003eCompatibility that decides the order\u003c\/th\u003e\n\u003cth\u003eHow it ships\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003eCS6.2 ultrasonic cleaner\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L tank, 31.1 x 17.2 x 11.6 cm; dual frequency 32\/48 kHz; two ceramic heaters; digital timer; 120-second degas\u003c\/td\u003e\n\u003ctd\u003eOne full instrument cassette per cycle; certification by Intertek to CSA C22.2 No. 68 and UL 73 (cETL)\u003c\/td\u003e\n\u003ctd\u003eSingle bench unit with basket, part SB01; replacement baskets ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003eMulti-enzyme cleaning solution\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eProtease, lipase, amylase and cellulase; low-foam; 1:400 to 1:600; 2-10 minutes at 20-50 degrees C\u003c\/td\u003e\n\u003ctd\u003eA 6 L tank takes 15 mL at 1:400 (10 mL at 1:600); 24 months sealed, 90 days after opening\u003c\/td\u003e\n\u003ctd\u003e1 L bottle or 5 L pail; one 5 L pail makes 2,000 to 3,000 litres of working solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-constant-heat-pouch-sealer-200-c-12mm-seal-110v-dental-sterilization\"\u003eConstant-heat pouch sealer\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e200 degrees C thermostatic head; 12 mm seal width; 300 mm maximum seal length; 100 W, 110 V \/ 60 Hz; IPX0 indoor use\u003c\/td\u003e\n\u003ctd\u003ePouches and rolls up to 300 mm wide, three rolls side by side; 2-3 minute pre-heat then continuous operation\u003c\/td\u003e\n\u003ctd\u003eOne stainless-steel bench unit with built-in cutter; no consumables included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/dlab-hb120-s-led-digital-dry-bath-incubator\"\u003eHB105-S1 dry-bath incubator\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20 wells (5 x 4) at 11 mm; room temperature +5 to 105 degrees C; +\/-0.5 degrees C control; 115 V, 110 W\u003c\/td\u003e\n\u003ctd\u003eSelf-contained vials of 8 mm body and 10 mm cap; cTUVus to UL 61010-1 and CAN\/CSA-C22.2 No. 61010-1-12\u003c\/td\u003e\n\u003ctd\u003eSingle unit, 3.2 kg with block fitted; display only, no data export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-24-hour-biological-indicator-incubator-precision-dry-block-15-wells\"\u003e24-hour incubator with USB export\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e56-60 degrees C held to +\/-0.5 degrees C; 8.8 mm machined wells; LCD with USB data export; 100-240 V adapter\u003c\/td\u003e\n\u003ctd\u003eAmpoules read at 56-60 degrees C, the growth band for Geobacillus stearothermophilus\u003c\/td\u003e\n\u003ctd\u003eOne bench unit; no case pack exists, and a two-year warranty applies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-rapid-reader-4-well-fluorescence-biological-indicator-reader\"\u003e4-well fluorescence reader\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eFour wells, model TR-R30MP4, held at 56-60 degrees C; reports positive or negative fluorescence; USB result storage\u003c\/td\u003e\n\u003ctd\u003eReads 20-minute, 1-hour and 3-hour fluorescence ampoules; none are included in the box\u003c\/td\u003e\n\u003ctd\u003eInstrument only; ampoules reordered as separate 50-packs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eDo you need a pouch sealer if you already buy self-sealing pouches?\u003c\/h2\u003e\n\u003cp\u003eSelf-sealing pouches close on a pressure-sensitive strip: no machine, no pre-heat, one fixed size per pack, and nothing to warm up at the start of the day. A sealer covers the two cases a pre-made pouch cannot. Packs longer or wider than any stocked size, and rolls cut to the length the pack actually needs - the \u003ca href=\"\/en-us\/products\/clinieco-medical-sterilization-roll-pre-cut-sheets-50m-roll\"\u003e76 mm by 50 m sterilization roll\u003c\/a\u003e is the usual starting point, and a 30 cm cut gives roughly 166 pouches per roll. If every pack you make already fits the \u003ca href=\"\/en-us\/products\/clinieco-sterilization-pouch-class-4-self-sealing-dual-indicator-200-per-box\"\u003eClass 4 self-sealing pouch\u003c\/a\u003e you buy, the sealer adds a step and removes none.\u003c\/p\u003e\n\u003cp\u003eThe seam is the part that matters. A constant-heat head holds one temperature for the whole run instead of spiking per impulse, and the 12 mm band is the full width of the heating element, which is what lets the pack peel open at the point of use without the film tearing away from the paper. That is a packaging decision, not a sterilization one: the seal keeps the contents sterile until opening, and the indicator inside the pack is what reports whether the cycle reached it.\u003c\/p\u003e\n\n\u003ch2\u003eWhat has to be in place before the units go into service?\u003c\/h2\u003e\n\u003cp\u003eThree things, and none of them is optional. First, the electrical side: the cleaner is certified to CSA C22.2 No. 68 and UL 73, the dry block to CAN\/CSA-C22.2 No. 61010-1-12, and all of it runs on 110-115 V at 60 Hz in a Canadian clinic. Second, the water and the bench: the tank needs a low-foam enzyme at the dilution above, a rinse step after the cycle, and an indoor IPX0 position that will not be splashed. Third, the monitoring routine, which has to start with the first cycle rather than the first inspection.\u003c\/p\u003e\n\u003cp\u003eIn Ontario, the dental regulator's infection-control standard expects a biological indicator on every day a sterilizer runs, a chemical indicator in every pack, and a written record of both. The practical version of that routine is a \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-50-pack\"\u003e24-hour self-contained spore test\u003c\/a\u003e read by colour change, a \u003ca href=\"\/en-us\/products\/clinieco-medical-steam-chemical-integrator-class-5-iso-11140-1-type-5-100-pack\"\u003eClass 5 integrator (ISO 11140-1 Type 5)\u003c\/a\u003e in each pack, \u003ca href=\"\/en-us\/products\/clinieco-medical-bowie-dick-test-pack-iso-11140-5-type-2-daily-vacuum-check-6-pack\"\u003eBowie-Dick packs (ISO 11140-5 Type 2)\u003c\/a\u003e for the daily vacuum check on a pre-vacuum unit, and \u003ca href=\"\/en-us\/products\/clinieco-medical-autoclave-tape-sterilization-indicator-tape-3-roll-set\"\u003eClass 1 indicator tape\u003c\/a\u003e on the outside. Practices that read rapid results instead use the \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-20-minute-rapid-readout-50-pack\"\u003e20-minute\u003c\/a\u003e or \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-3-hour-rapid-readout-fluorescence-50-pack\"\u003e3-hour fluorescence ampoules\u003c\/a\u003e in the reader above.\u003c\/p\u003e\n\u003cp\u003eWhat none of that does is certify a load as sterile. An indicator reports the conditions inside the pack it travelled in; it is evidence about the cycle, not a statement about every instrument in the room. The record is what turns the evidence into something an inspector can check, and the field list for it is at the \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003ecompliance log centre\u003c\/a\u003e, printable and free to use.\u003c\/p\u003e\n\n\u003ch2\u003eBatch, compatibility and ordering notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConsumables never ship with instruments: no ampoules with the reader, no solution with the tank. Order both lines or nothing runs on day one.\u003c\/li\u003e\n\u003cli\u003eWell diameter is a specification, not a detail. An 11 mm block takes an 8 mm vial body with a 10 mm cap; a wider cap will not seat, and a loose tube with an air gap around it is the usual reason one indicator in a batch reads late.\u003c\/li\u003e\n\u003cli\u003eThe incubator and the reader leave as single bench units. There is no case pack of either, and no quantity discount that changes the fact that one reprocessing bench needs one of each.\u003c\/li\u003e\n\u003cli\u003eSolution has a clock: 24 months sealed, 90 days once opened, so a larger pack only saves money if the volume justifies it inside that window.\u003c\/li\u003e\n\u003cli\u003eEquipment ships under CliniEco Medical's MDEL #35334 as a licensed importer and distributor; documentation, manuals and certificates are supplied as documents on request.\u003c\/li\u003e\n\u003cli\u003eFrench-language manuals are available on request; the units themselves are marked in English and use North American plugs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhere to go next\u003c\/h2\u003e\n\u003cp\u003eClinics ordering a full room - tank, sealer, block, reader and the consumables behind them - can open an account with volume terms on the \u003ca href=\"\/en-us\/pages\/wholesale\"\u003eclinic and institutional ordering page\u003c\/a\u003e. If the question is not which unit but which monitoring interval applies to your sterilizers, that answer belongs with a specialist: send it through the \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003esterilization compliance consultation\u003c\/a\u003e and it comes back in writing, with the standard behind it. Packaging and the tests themselves are one click away in the two collections linked above.\u003c\/p\u003e\n","products":[{"product_id":"clinieco-rapid-reader-4-well-fluorescence-biological-indicator-reader","title":"CliniEco Rapid Reader — 4-Well Fluorescence Biological Indicator Reader (20-Minute \/ 1-Hour \/ 3-Hour Readout)","description":"\u003cdiv style=\"border:1px solid #E9EEF2;border-radius:8px;padding:14px 16px;margin:0 0 18px 0;background:#F7FAFB\"\u003e\n\u003cstrong\u003eQuoted per order\u003c\/strong\u003e — this unit is supplied against a confirmed order. Send us your clinic's requirements and we will confirm lead time and price. \u003ca href=\"\/en-us\/pages\/wholesale\"\u003eRequest a quote\u003c\/a\u003e\n\u003c\/div\u003e\u003cdiv class=\"clini-prod\"\u003e\n  \u003cdiv class=\"clini-prod-hero\"\u003e\n    \n\u003ch2 class=\"clini-prod-title\"\u003e⚡ CliniEco Rapid Reader\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eThis listing is the instrument that reads fluorescent biological indicators — not the indicators themselves.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cp\u003eInstrument-read fluorescence results — \u003cstrong\u003e20 minutes \/ 1 hour \/ 3 hours with our rapid-readout BIs\u003c\/strong\u003e (steam rapid modes per the reader manufacturer's technical data sheet)\u003c\/p\u003e\n    \u003cp\u003e4-well fluorescence reader for biological indicators\u003c\/p\u003e\n    \n  \u003c\/div\u003e\n\u003cp\u003eWhat ships is the reader: a four-well bench unit, model TR-R30MP4, holding ampoules at 56-60 °C and reporting a positive or negative fluorescence result. The ampoules are consumables bought separately; none of this page's $1,499 CAD is a box of tests, and an ampoule on its own cannot report a result.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/how-often-us-vs-canadian-clinics-sterilizer-testing-incubator-guide\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/Reader01_2400sq.png?v=1793406845\" alt=\"CliniEco Rapid Reader — 4-Well Fluorescence Biological Indicator Reader (20-Minute \/ 1-Hour \/ 3-Hour Readout)\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eIs this the reader or the indicators?\u003c\/h2\u003e\n\u003cp\u003eThis page sells the reader only. The ampoules it reads are stocked as separate 50-packs and reordered monthly, so a clinic needs both lines to get a result: the instrument once, the vials continuously. The price gap shows which is which — the hardware is priced on this page, the fluorescence vials are priced per 50-pack on their own pages, and the per-test figure follows there by dividing. Opening the ampoule page when you meant the reader, or the reverse, costs a cycle: no vial means no test that day.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReader or indicators — which purchase applies to your clinic (CliniEco, checked October 2026)\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBuy the Rapid Reader if…\u003c\/th\u003e\n\u003cth\u003eBuy only the indicators if…\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eYour daily spore test uses a 20-minute fluorescence ampoule\u003c\/td\u003e\n\u003ctd\u003eYour daily spore test uses a 24-hour self-contained vial read by colour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eYour daily spore test uses a 1-hour fluorescence ampoule\u003c\/td\u003e\n\u003ctd\u003eYou read that colour change by eye after overnight incubation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eYour daily spore test uses a 3-hour fluorescence ampoule\u003c\/td\u003e\n\u003ctd\u003eNext-morning results already fit the way your day opens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eYou want the positive or negative result reported by the instrument\u003c\/td\u003e\n\u003ctd\u003eYou judge the result yourself against the unincubated control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eYou want the result stored on the device and exported over USB\u003c\/td\u003e\n\u003ctd\u003eA paper log sheet is the record you keep and file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eYou are moving a clinic from visual to instrument-read monitoring\u003c\/td\u003e\n\u003ctd\u003eYou already own a reader that takes your current ampoules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhich biological indicators work with this reader, and what do they cost per test?\u003c\/h2\u003e\n\u003cp\u003eThree fluorescence rapid-readout 50-packs fit this instrument, and the readout time is set by the ampoule rather than by the reader: the \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-20-minute-rapid-readout-50-pack\"\u003e20-minute 50-pack\u003c\/a\u003e, the \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-1-hour-rapid-readout-50-pack\"\u003e1-hour 50-pack\u003c\/a\u003e and the \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-3-hour-rapid-readout-fluorescence-50-pack\"\u003e3-hour 50-pack\u003c\/a\u003e, each priced on its own page with the per-test figure following from the pack amount. The ampoules are sold separately and are not covered by the price of this instrument. Wells accept 8-11 mm ampoules and hold four at a time. The \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-50-pack\"\u003e24-hour self-contained 50-pack\u003c\/a\u003e is a different product type and is not read by this instrument.\u003c\/p\u003e\n\u003ch2\u003eDo I need this reader if I use 24-hour self-contained BIs?\u003c\/h2\u003e\n\u003cp\u003eNo. A 24-hour self-contained vial carries its own medium and turns colour when spores survive; after incubation the result is read by eye against a control, with no instrument in the loop. Pairing that vial with this reader adds $1,499 CAD of equipment the vial cannot use, because the wells are heated and optically read for fluorescence ampoules. The decision is therefore about which readout tier your working day needs: the 24-hour vial and the rapid ampoule carry different per-test figures, each set by the price shown on its own 50-pack page, while a fluorescence tier buys the same-day answer that lets a load return to the chair or the tray before the next cycle.\u003c\/p\u003e\n\u003cp\u003ePut the choice on paper before the purchase order goes out: the \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003espore-test log sheet\u003c\/a\u003e shows the column your daily record has to fill, the \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003esterilization log generator\u003c\/a\u003e turns four wells a day into a month of entries, and the \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003ecompliance desk\u003c\/a\u003e will answer the reader-versus-ampoule question in writing, citing the regulation it relies on. This reader reaches Canada under establishment number MDEL #35334, held by CliniEco Medical, Toronto.\u003c\/p\u003e\n\n\n\n\n  \u003cdiv class=\"clini-prod-benefit\"\u003e\n    \u003cp\u003e✅ \u003cstrong\u003eReads rapid fluorescence BI ampoules\u003c\/strong\u003e (20 min \/ 1 h \/ 3 h with our rapid-readout BIs) | ✅ \u003cstrong\u003eOur 24-hour BIs are self-contained and read visually — no reader needed\u003c\/strong\u003e | ✅ \u003cstrong\u003eNo locked equipment\u003c\/strong\u003e — works with standard BI ampoules | ✅ \u003cstrong\u003eFluorescence readout\u003c\/strong\u003e (positive\/negative) | ✅ \u003cstrong\u003eDaily RCDSO\/PHO biological monitoring ready\u003c\/strong\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"clini-price-box\"\u003e\n    \u003cp style=\"margin:0;font-size:14px;color:#6b7280;\"\u003eCompare: 3M Attest Mini Auto-reader 490M — \u003cstrong\u003eCAD 1,162–1,410\u003c\/strong\u003e at four Canadian distributors (Clinical Research Dental, 3B Dahabi, 3Z Dental, United Canada), read 30 Oct 2026\u003c\/p\u003e\n    \u003cp style=\"margin:4px 0;\"\u003e\u003cspan class=\"old\"\u003e\u003c\/span\u003e \u003cspan class=\"new\"\u003e$1,499 CAD\u003c\/span\u003e\u003c\/p\u003e\n    \u003cspan class=\"save\"\u003eLaunch price — professional-grade 4-well fluorescence reader\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"background:linear-gradient(135deg,#123a2f 0%,#206270 100%);border-radius:14px;padding:24px 24px;color:#fff;margin:20px 0;text-align:center;\"\u003e\n    \u003ch2 style=\"margin:0 0 8px;font-size:1.4rem;\"\u003eSold on its own — $1,499 CAD\u003c\/h2\u003e\n    \u003cp style=\"margin:4px 0;font-size:1rem;opacity:.95;\"\u003eThis reader is $1,499 CAD, with no term and nothing to commit to. Our 3-hour indicators are priced per 50-pack on their own page.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e$1,499 CAD — fully deductible against your rapid BIs.\u003c\/strong\u003e Buy the reader now and, within 12 months, the full $1,499 CAD comes back to you as credit on rapid BI purchases once you have ordered $1,500 CAD of rapid BIs. Net cost of the hardware: $0 CAD. The credit applies to the reader only, caps at $1,499 CAD, and does not stack with other offers.\u003c\/p\u003e\n    \u003cp style=\"margin:8px 0 0;font-size:0.9rem;opacity:.85;\"\u003eNo locked equipment · Works with standard rapid BI ampoules · Same-day compliance results\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"background:#f0f7ff;border:2px solid #206270;border-radius:10px;padding:16px;margin:16px 0;\"\u003e\n    \u003cp style=\"margin:0;font-size:14.5px;color:#333;\"\u003e🎁 \u003cstrong\u003eBuy the Reader — Get 1 Month of Rapid BIs FREE\u003c\/strong\u003e — order today and we'll include \u003cstrong\u003e50 rapid BI tests — one full month, a $249.99 CAD value (our 3-hour 50-pack)\u003c\/strong\u003e at no charge. Try the full rapid workflow from day one.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2 style=\"font-size:1.3rem;margin:24px 0 8px;\"\u003eWhy switch from 24-hour tests?\u003c\/h2\u003e\n  \u003cul style=\"margin:16px 0;padding-left:20px;\"\u003e\n    \u003cli style=\"margin:8px 0;\"\u003e⏱️ \u003cstrong\u003eResults in 20 minutes, 1 hour or 3 hours with our rapid-readout BIs — know same-day if your sterilizer passed\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli style=\"margin:8px 0;\"\u003e💰 \u003cstrong\u003eBI priced per vial on that vial's own page\u003c\/strong\u003e — the per-test figure is that page's 50-pack price divided by fifty, and 3M Attest rapid-readout ampoules are priced by channel, so set both figures from your own quotations rather than from a summary line here\u003c\/li\u003e\n    \u003cli style=\"margin:8px 0;\"\u003e🔓 \u003cstrong\u003eThree readout tiers on one instrument\u003c\/strong\u003e — this reader takes standard 8–11 mm ampoules across the 20-minute, 1-hour and 3-hour tiers, while the 3M Attest Mini Auto-reader 490M reads only its own closed set of 24-minute rapid ampoules (per 3M IFU)\u003c\/li\u003e\n    \u003cli style=\"margin:8px 0;\"\u003e✅ \u003cstrong\u003eDaily compliance made easy\u003c\/strong\u003e — required by RCDSO\/PHO, results when you need them\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cdiv class=\"clini-trust\"\u003e\n    \u003ch3\u003e🛡️ Built to Clinical Standards — Inside This Reader\u003c\/h3\u003e\n    \u003cdiv class=\"clini-trust-grid\"\u003e\n      \u003cdiv class=\"clini-trust-item\"\u003e\n        \u003ch4\u003e🔬 Precision Optical Detection\u003c\/h4\u003e\n        \u003cp\u003eBlue LED excitation (~460nm) + silicon photodiode sensor with bandpass filter, in a light-sealed optical chamber — the same detection principle used by major brands, delivering clear positive\/negative fluorescence readouts.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"clini-trust-item\"\u003e\n        \u003ch4\u003e🌡️ 58°C ± 2°C Culture Temperature\u003c\/h4\u003e\n        \u003cp\u003ePID-controlled PTC heating block with NTC temperature sensor, holding a 58°C culture temperature (±2°C), i.e. 56-60°C — critical for accurate BI results.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"clini-trust-item\"\u003e\n        \u003ch4\u003e⚙️ Industrial-Grade Mainboard\u003c\/h4\u003e\n        \u003cp\u003eARM-based microcontroller with on-board memory (10,000+ result log), real-time clock, USB data export — audit-ready record keeping built in.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"clini-trust-item\"\u003e\n        \u003ch4\u003e🔌 Robust Power \u0026amp; Build\u003c\/h4\u003e\n        \u003cp\u003e100-240V AC worldwide power adapter, injection-molded enclosure, 2-year warranty with Toronto-based support.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHave a question about your own facility?\u003c\/strong\u003e Send it in and you will get a written answer specific to your setup, with the regulation or standard it is based on cited. \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003eAsk your compliance question\u003c\/a\u003e.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"clini-cert-row\"\u003e\n      \u003cspan class=\"clini-cert-chip\"\u003e✅ FCC Compliant\u003c\/span\u003e\n      \n      \u003cspan class=\"clini-cert-chip\"\u003e✅ 2-Year Warranty\u003c\/span\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2 style=\"font-size:1.3rem;margin:24px 0 8px;\"\u003eHow We Compare — Spec by Spec\u003c\/h2\u003e\n  \u003ctable class=\"clini-prod-spec\"\u003e\n    \u003ctr\u003e\n\u003cth style=\"width:32%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eCliniEco Rapid Reader\u003c\/th\u003e\n\u003cth\u003e3M Attest 490M\u003c\/th\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWells\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDetection Method\u003c\/td\u003e\n\u003ctd\u003eFluorescence enzyme (LED + photodiode)\u003c\/td\u003e\n\u003ctd\u003eFluorescence (proprietary)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eReadout Time\u003c\/td\u003e\n\u003ctd\u003e3 hours with CliniEco 3-hour rapid BIs\u003c\/td\u003e\n\u003ctd\u003e24 min with 3M super-rapid BIs (per 3M IFU)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e56-60°C (58°C ± 2°C setpoint)\u003c\/td\u003e\n\u003ctd\u003e60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBI Compatibility\u003c\/td\u003e\n\u003ctd\u003eOpen — 8-11 mm fluorescence BI ampoules, no lock-in; the BI's rapid mode must match 20 min \/ 1 h \/ 3 h (manufacturer compatibility statement)\u003c\/td\u003e\n\u003ctd\u003eLocked to 3M Attest BIs\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003e10,000+ results, USB export\u003c\/td\u003e\n\u003ctd\u003eAttest Connect (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eReader Price\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e$1,499 CAD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eCAD 1,162–1,410\u003c\/strong\u003e (4 distributors, read 30 Oct 2026)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eBI Price (per test)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSee each 50-pack page\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSee the 3M dealer's box-of-50 price\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:1.3rem;margin:24px 0 8px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003ctable class=\"clini-prod-spec\"\u003e\n    \u003ctr\u003e\n\u003cth style=\"width:35%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTR-R30MP4 (4-well rapid fluorescence reader)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDetection Method\u003c\/td\u003e\n\u003ctd\u003eFluorescence enzyme (α-glucosidase + fluorescent substrate)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eReadout Time\u003c\/td\u003e\n\u003ctd\u003e3 hours (our 3-hour rapid BIs)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWells\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCompatible Ampoules\u003c\/td\u003e\n\u003ctd\u003eRapid BI ampoules Φ8-11 mm; rapid mode must match 20 min \/ 1 h \/ 3 h\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eClear positive\/negative readout\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e110V\/60Hz (North America)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e56-60°C (58°C ± 2°C setpoint)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eSteam sterilization monitoring (daily RCDSO\/PHO compliance)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eManufacturer documentation available on request\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eImport\u003c\/td\u003e\n\u003ctd\u003eCliniEco Medical, Toronto, ON\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:1.3rem;margin:24px 0 8px;\"\u003eHow it works\u003c\/h2\u003e\n  \u003col style=\"margin:16px 0;padding-left:20px;\"\u003e\n    \u003cli style=\"margin:6px 0;\"\u003eRun your daily sterilization cycle\u003c\/li\u003e\n    \u003cli style=\"margin:6px 0;\"\u003ePlace a rapid BI ampoule in the reader\u003c\/li\u003e\n    \u003cli style=\"margin:6px 0;\"\u003eGet the instrument-read result at the indicator's readout time (3 h with our 3-hour rapid BIs) — positive or negative\u003c\/li\u003e\n    \u003cli style=\"margin:6px 0;\"\u003eRecord results for RCDSO\/PHO audit compliance\u003c\/li\u003e\n  \u003c\/ol\u003e\n\n  \u003ca href=\"\/en-us\/pages\/wholesale\" class=\"clini-prod-cta\"\u003eRequest a quote for the Rapid Reader →\u003c\/a\u003e\n\n  \u003cp class=\"clini-prod-note\"\u003eSold on its own at $1,499 CAD, with no plan and no term.\u003cbr\u003e\n  Questions? Email \u003ca href=\"mailto:alina@clinieco.ca\"\u003ealina@clinieco.ca\u003c\/a\u003e · +1 (437) 466-2232\u003c\/p\u003e\n  \u003cp class=\"clini-prod-note\"\u003eCliniEco Medical · Toronto, ON\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-guides-block\"\u003e\n\u003ch3\u003eRelated Guides\u003c\/h3\u003e\n\u003cp\u003eLearn how to choose and use this product correctly:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/sterility-assurance-level-sal-explained-what-10-6-means-for-sterilization\"\u003eSterility Assurance Level (SAL) Explained: What 10-6 Means for Sterilization\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/what-to-do-when-a-biological-indicator-test-fails\"\u003eBiological Indicator Failure: Recall, Root Cause, and Re-Test Protocol\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/class-4-vs-class-5-vs-class-6-sterilization-indicators-what-each-level-means\"\u003eClass 4 vs 5 vs 6 Sterilization Indicators: Which Do You Need?\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/how-often-should-you-run-a-spore-test-sterilizer-monitoring-schedules\"\u003eHow Often Should You Run a Spore Test? Sterilizer Monitoring Schedules\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n .clini-prod { max-width:760px; margin:0 auto; font-family:-apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, sans-serif; color:#111827; }\n .clini-prod-hero { background:linear-gradient(135deg,#206270 0%,#2A5C8A 100%); border-radius:14px; padding:32px 28px; color:#fff; text-align:center; margin-bottom:24px; }\n .clini-prod-hero.clini-prod-title { font-size:1.9rem; margin:0 0 8px; font-weight:800; }\n .clini-prod-hero p { font-size:1.05rem; margin:4px 0; opacity:0.95; }\n .clini-prod-badge { display:inline-block; background:rgba(255,255,255,0.2); border:1px solid rgba(255,255,255,0.5); border-radius:20px; padding:4px 14px; font-size:0.85rem; margin-top:10px; }\n .clini-prod-benefit { background:#f0f7ff; border:1px solid #2A5C8A; border-radius:10px; padding:16px; margin:16px 0; }\n .clini-prod-benefit p { margin:0; font-size:14.5px; color:#333; }\n .clini-prod-cta { display:block; text-align:center; background:#206270; color:#fff; text-decoration:none; border-radius:10px; padding:16px 24px; font-weight:700; font-size:17px; margin:20px 0; }\n .clini-prod-cta:hover { background:#1645c7; }\n .clini-prod-spec { width:100%; border-collapse:collapse; margin:16px 0; font-size:14px; }\n .clini-prod-spec th { background:#2A5C8A; color:#fff; padding:10px 12px; text-align:left; }\n .clini-prod-spec td { padding:10px 12px; border-bottom:1px solid #e5e7eb; }\n .clini-prod-spec tr:nth-child(even) { background:#f9fafb; }\n .clini-prod-note { text-align:center; color:#6b7280; font-size:13px; margin-top:10px; }\n .clini-price-box { background:#fff7ed; border:2px solid #f97316; border-radius:10px; padding:20px; text-align:center; margin:20px 0; }\n .clini-price-box.old { color:#9ca3af; text-decoration:line-through; font-size:16px; }\n .clini-price-box.new { color:#ea580c; font-size:32px; font-weight:800; }\n .clini-price-box.save { background:#f97316; color:#fff; display:inline-block; padding:4px 12px; border-radius:20px; font-size:14px; font-weight:600; margin-top:8px; }\n .clini-trust { background:#f8fafc; border:1px solid #d1d5db; border-radius:12px; padding:20px; margin:20px 0; }\n .clini-trust h3 { margin:0 0 12px; font-size:1.1rem; color:#123a2f; }\n .clini-trust-grid { display:grid; grid-template-columns:1fr 1fr; gap:12px; }\n .clini-trust-item { background:#fff; border:1px solid #e5e7eb; border-radius:8px; padding:12px; }\n .clini-trust-item h4 { margin:0 0 4px; font-size:0.95rem; color:#206270; }\n .clini-trust-item p { margin:0; font-size:13px; color:#4b5563; line-height:1.5; }\n .clini-cert-row { display:flex; flex-wrap:wrap; gap:8px; margin-top:12px; }\n .clini-cert-chip { background:#e8f1f5; color:#123a2f; border-radius:20px; padding:5px 14px; font-size:12.5px; font-weight:600; }\n\u003c\/style\u003e\n\n\u003c!-- bi-family-crosslink v1 --\u003e\n\u003ch3\u003eRelated tests in this BI line\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-clinic-starter-bundle-gloves-spore-testing-sterilization-packaging\"\u003eClinic Starter Bundle — Gloves, Spore Testing \u0026amp; Sterilization Packaging\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-24-hour-biological-indicator-incubator-precision-dry-block-15-wells\"\u003eCliniEco 24-Hour Biological Indicator Incubator — Precision Dry-Block, 24 Wells\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-1-hour-rapid-readout-50-pack\"\u003eCliniEco Medical Biological Indicator — 1-Hour Rapid Readout, Fluorescence, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-20-minute-rapid-readout-50-pack\"\u003eCliniEco Medical Biological Indicator — 20-Minute Rapid Readout, Fluorescence, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-100-pack\"\u003eCliniEco Medical Biological Indicator — 24-Hour Self-Contained, 100-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003eCliniEco Medical Biological Indicator — 24-Hour Self-Contained, 25-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-50-pack\"\u003eCliniEco Medical Biological Indicator — 24-Hour Self-Contained, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-3-hour-rapid-readout-fluorescence-50-pack\"\u003eCliniEco Medical Biological Indicator — 3-Hour Rapid Readout, Fluorescence, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/pages\/bi-sample-request\"\u003eFree Biological Indicator 5-Pack (clinics)\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-bowie-dick-test-pack-iso-11140-5-type-2-daily-vacuum-check-6-pack\"\u003eCliniEco Medical Bowie-Dick Test Pack — ISO 11140-5 Type 2, Daily Vacuum Check, 6-Pack\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/how-to-choose-biological-indicator-incubator-canadian-clinic\"\u003eHow to Choose a Biological Indicator Incubator for a Canadian Clinic\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/24-hour-self-contained-biological-indicator-pack-sizes-incubation-record\"\u003e24-Hour Self-Contained Biological Indicators: Pack Sizes, Incubation and the Record\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/which-standards-medical-biological-indicator-us-vs-canada\"\u003eWhich Standards Apply to Medical Biological Indicator in the US vs Canada? Sizes and Sourcing\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/which-standards-hb105-s2-dry-bath-incubator-us-vs-canada\"\u003eWhich Standards Apply to HB105-S1 Dry Bath Incubator with Lid in the US vs Canada? Sizes and Sourcing\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":48763291762910,"sku":"CLI-RR-004","price":1499.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/READER-HERO-logo-20261110_6c6c68d1-61ce-4d5f-a376-fd915de29912_2f79a230-d1d6-4131-a722-b77e3c817a69.jpg?v=1794344612"},{"product_id":"clinieco-24-hour-biological-indicator-incubator-precision-dry-block-15-wells","title":"CliniEco 24-Hour Biological Indicator Incubator — Precision Dry-Block, 24 Wells","description":"\u003ch2\u003eWhich biological indicator vials seat properly in this dry block?\u003c\/h2\u003e\n\u003cp\u003eThe block is machined with twenty-four wells of eight point eight millimetres across, cut to the outside diameter of a self-contained spore ampoule, so a standard tube drops in flush and the aluminium wall carries heat the whole length of the vial. A wider cap will not enter the well at all, and an undersized tube sits loose with an air gap around it, which is the usual reason one indicator in a batch reads late. Anything used here has to be read at 56 to 60 degrees C, the growth band for \u003cem\u003eGeobacillus stearothermophilus\u003c\/em\u003e; the \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-50-pack\"\u003e24-hour spore test ampoules\u003c\/a\u003e match that well format and that temperature window.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003e24-hour biological indicator incubator: block, power and order facts as listed\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDry-block biological indicator incubator, 24-hour read\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature zone\u003c\/td\u003e\n\u003ctd\u003e56–60 °C, held to ±0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWells\u003c\/td\u003e\n\u003ctd\u003e24, machined aluminium block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell diameter\u003c\/td\u003e\n\u003ctd\u003e8.8 mm, matched to standard spore ampoules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVial compatibility\u003c\/td\u003e\n\u003ctd\u003eSelf-contained ampoules, \u003cem\u003eG. stearothermophilus\u003c\/em\u003e ATCC 7953\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecords\u003c\/td\u003e\n\u003ctd\u003eLCD temperature display with USB data export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e100–240 V AC external adapter, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSold as\u003c\/td\u003e\n\u003ctd\u003eOne bench unit, not a case pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eCLI-INC-24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eTwo years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eIs one unit the right order, or does a clinic buy a case of them?\u003c\/h2\u003e\n\u003cp\u003eA case pack does not exist for this device: it leaves as a single bench unit with its external adapter, so the SKU on the invoice is one machine and a busy office usually stops there. The reprocessing bench is where incubation happens, not each operatory, so four chairs sharing one sterilizer need one block and a second one only when a second sterilizer sits in another suite. Buying two units for redundancy sounds prudent until both sit half full and neither is ever the one an auditor asks to see.\u003c\/p\u003e\n\u003ch2\u003eHow many wells does a three-sterilizer office fill in a working week?\u003c\/h2\u003e\n\u003cp\u003eCount one well per sterilizer per day it is run. Three sterilizers across a five-day week is fifteen wells, a six-day week is eighteen, and a 24-well block still holds six seats for the re-test that follows a failed indicator and for the extra run after a holiday closure. That spare room is the practical reason the block is sized above a single day's load: a failure on Friday afternoon cannot wait for Monday if the block is already full. Offices that want a same-shift answer pair this block with a rapid reader, or step down to a \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-1-hour-rapid-readout-50-pack\"\u003eone-hour readout indicator\u003c\/a\u003e and read it in the reader at the bench.\u003c\/p\u003e\n\u003cp\u003ePrint the daily record sheet from the \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003espore log and record centre\u003c\/a\u003e, work out how many indicators a week of clinics consumes with the \u003ca href=\"\/en-us\/pages\/clinic-supply-planner\"\u003esterilizer run planner\u003c\/a\u003e, and put a procedure question to the \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003esterilization compliance desk\u003c\/a\u003e. Districts consolidating several sites order through the \u003ca href=\"\/en-us\/pages\/wholesale\"\u003eclinic ordering desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/how-to-choose-biological-indicator-incubator-canadian-clinic\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/clinicare_incubator_main_v2.png?v=1788450549\" alt=\"CliniEco 24-Hour Biological Indicator Incubator — Precision Dry-Block, 24 Wells\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eDistributed in Canada by CliniEco Medical, Toronto, under MDEL #35334.\u003c\/p\u003e\n\u003cdiv class=\"clini-prod\"\u003e \u003cdiv class=\"clini-prod-hero\"\u003e \u003ch2 class=\"clini-prod-title\"\u003eCliniEco 24-Hour Biological Indicator Incubator\u003c\/h2\u003e \u003cp\u003eDaily sterilization monitoring made simple — audit-ready for Ontario dental clinics\u003c\/p\u003e\n\u003c\/div\u003e \u003cdiv class=\"clini-prod-section\"\u003e \u003ch2\u003eWhy Your Clinic Needs This\u003c\/h2\u003e \u003cp\u003eOntario regulations (RCDSO\/PHO) require \u003cstrong\u003eDAILY biological monitoring\u003c\/strong\u003e of sterilizers. Our 24-hour incubator gives you reliable, in-office spore testing with precision temperature control — at a fraction of the cost of major brands.\u003c\/p\u003e \u003cdiv class=\"clini-prod-note\"\u003e💡 \u003cstrong\u003ePrecision dry-block incubation\u003c\/strong\u003e — ±0.5 °C accuracy with LCD display, in a compact 24-well format.\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"clini-trust\"\u003e \u003ch3\u003e🛡️ Built to Clinical Standards — Inside This Incubator\u003c\/h3\u003e \u003cdiv class=\"clini-trust-grid\"\u003e \u003cdiv class=\"clini-trust-item\"\u003e \u003ch4\u003e🌡️ ±0.5°C Precision Heating\u003c\/h4\u003e \u003cp\u003ePID-controlled dry-block heating element with NTC temperature sensor holds a stable 56-60°C incubation zone — critical for accurate BI growth and reliable results.\u003c\/p\u003e\n\u003c\/div\u003e \u003cdiv class=\"clini-trust-item\"\u003e \u003ch4\u003e🔧 Machined Aluminum Block\u003c\/h4\u003e \u003cp\u003eCNC-machined aluminum heating block with 24 precision wells (φ8.8 mm, matched to standard BI vial outer diameter), ensuring consistent thermal contact across every vial.\u003c\/p\u003e\n\u003c\/div\u003e \u003cdiv class=\"clini-trust-item\"\u003e \u003ch4\u003e⚙️ Industrial-Grade Control\u003c\/h4\u003e \u003cp\u003eMicrocontroller-based temperature control with real-time LCD display and USB data export — audit-ready records for RCDSO inspections.\u003c\/p\u003e\n\u003c\/div\u003e \u003cdiv class=\"clini-trust-item\"\u003e \u003ch4\u003e🔌 Robust Build \u0026amp; Support\u003c\/h4\u003e \u003cp\u003e100–240 V AC external adapter (50\/60 Hz), 2-year warranty, Toronto-based support with Canadian distribution under MDEL #35334.\u003c\/p\u003e\n\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"clini-cert-row\"\u003e \u003cspan class=\"clini-cert-chip\"\u003e✅ 2-Year Warranty\u003c\/span\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"clini-prod-section\"\u003e \u003ch2\u003eSpecifications\u003c\/h2\u003e \u003ctable class=\"clini-prod-table\"\u003e \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDry-block biological indicator incubator (24h)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e56-60°C (±0.5°C precision)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eWells\u003c\/td\u003e\n\u003ctd\u003e24 wells (φ8.8 mm, matched to standard BI vial diameter)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eSelf-contained BI ampoules (G. stearothermophilus ATCC 7953)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD temperature display\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eData\u003c\/td\u003e\n\u003ctd\u003eUSB data export (optional record software)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e100-240V AC 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-year warranty\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"clini-prod-section\"\u003e \u003ch2\u003eWhy CliniEco\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003ePrecision:\u003c\/strong\u003e ±0.5 °C dry-block control held across all 24 wells\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eNo lock-in:\u003c\/strong\u003e works with any standard 56-60 °C BI ampoules\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eAudit-ready:\u003c\/strong\u003e pair with our free printable record sheets\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003eMade for Canada:\u003c\/strong\u003e 110V\/60Hz, EN\/FR labeling, Toronto-based support\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv class=\"clini-prod-section\" style=\"text-align:center\"\u003e \u003ch2\u003eSold on its own\u003c\/h2\u003e \u003cp\u003eOur 24-hour indicators start at $2.80 each in the 25-pack, and the price per strip drops as the pack size goes up.\u003c\/p\u003e \u003ca class=\"clini-prod-cta\" href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003eShop the 25-pack\u003c\/a\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eBiological indicator packs priced for this block\u003c\/h2\u003e\n\u003cp\u003eThe block holds twenty-four wells of 8.8 mm, so the 24-hour self-contained ampoule is the format it was machined for; the fluorescence formats below are listed because they need the same bench space but a different readout device. Prices are per pack in CAD, and the cost per test is the pack price divided by the number of tests inside it — no quote required (MDEL #35334).\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePack \/ format\u003c\/th\u003e\n\u003cth\u003ePrice (CAD)\u003c\/th\u003e\n\u003cth\u003eCost per test\u003c\/th\u003e\n\u003cth\u003eOrder\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e24-hour self-contained BI\u003c\/td\u003e\n\u003ctd\u003e25-pack\u003c\/td\u003e\n\u003ctd\u003e$69.99\u003c\/td\u003e\n\u003ctd\u003e$2.80\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003e24-hour self-contained biological indicator, 25-pack\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24-hour self-contained BI\u003c\/td\u003e\n\u003ctd\u003e50-pack\u003c\/td\u003e\n\u003ctd\u003e$109.99\u003c\/td\u003e\n\u003ctd\u003e$2.20\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-50-pack\"\u003e24-hour self-contained biological indicator, 50-pack\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24-hour self-contained BI\u003c\/td\u003e\n\u003ctd\u003e100-pack\u003c\/td\u003e\n\u003ctd\u003e$189.00\u003c\/td\u003e\n\u003ctd\u003e$1.89\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-100-pack\"\u003e24-hour self-contained biological indicator, 100-pack\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCliniEco 24-hour dry-block incubator\u003c\/td\u003e\n\u003ctd\u003e24 wells\u003c\/td\u003e\n\u003ctd\u003e$379.00\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-24-hour-biological-indicator-incubator-precision-dry-block-15-wells\"\u003eCliniEco 24-hour biological indicator incubator, 24 wells\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-hour fluorescence BI (needs the reader)\u003c\/td\u003e\n\u003ctd\u003e50-pack\u003c\/td\u003e\n\u003ctd\u003e$269.99\u003c\/td\u003e\n\u003ctd\u003e$5.40\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-1-hour-rapid-readout-50-pack\"\u003e1-hour fluorescence biological indicators, 50-pack\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eWhich formats fit this block:\u003c\/strong\u003e the 24-hour self-contained ampoule drops straight into the 8.8 mm well and incubates at 56–60 °C; a fluorescence indicator of 1 hour, 3 hours or 20 minutes has to be read in the 4-well fluorescence reader instead, so it belongs on the same bench but not in this block. A cap wider than the well will not enter it, and an undersized tube sits loose with an air gap, which is the usual reason one vial in a batch reads late.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStock and shipping:\u003c\/strong\u003e orders ship from Ontario, Canada, and the exact dispatch date is confirmed with you before the order is released — we do not quote a delivery date at checkout. Every indicator pack carries its lot number, so the entry in your monitoring log can be traced back to the batch.\u003c\/p\u003e\n\u003cdiv class=\"product-guides-block\"\u003e\n\u003ch3\u003eRelated Guides\u003c\/h3\u003e\n\u003cp\u003eLearn how to choose and use this product correctly:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/sterility-assurance-level-sal-explained-what-10-6-means-for-sterilization\"\u003eSterility Assurance Level (SAL) Explained: What 10-6 Means for Sterilization\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/what-to-do-when-a-biological-indicator-test-fails\"\u003eBiological Indicator Failure: Recall, Root Cause, and Re-Test Protocol\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/class-4-vs-class-5-vs-class-6-sterilization-indicators-what-each-level-means\"\u003eClass 4 vs 5 vs 6 Sterilization Indicators: Which Do You Need?\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/how-often-should-you-run-a-spore-test-sterilizer-monitoring-schedules\"\u003eHow Often Should You Run a Spore Test? Sterilizer Monitoring Schedules\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e \u003cstyle\u003e.clini-prod { max-width:760px; margin:0 auto; font-family:-apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, sans-serif; color:#111827; }.clini-prod-hero { background:linear-gradient(135deg,#206270 0%,#2A5C8A 100%); border-radius:14px; padding:32px 28px; color:#fff; text-align:center; margin-bottom:24px; }.clini-prod-hero.clini-prod-title { font-size:26px; margin:0 0 8px; }.clini-prod-hero p { font-size:15px; opacity:.92; margin:4px 0; }.clini-prod-section { margin:24px 0; }.clini-prod-section h2 { font-size:18px; color:#206270; border-bottom:2px solid #E5E7EB; padding-bottom:8px; }.clini-prod-table { width:100%; border-collapse:collapse; margin:12px 0; }.clini-prod-table td { border:1px solid #E5E7EB; padding:10px 12px; font-size:14px; }.clini-prod-table td:first-child { background:#F9FAFB; font-weight:600; width:35%; }.clini-prod-cta { background:#206270; color:#fff; display:inline-block; padding:14px 32px; border-radius:8px; text-decoration:none; font-weight:600; font-size:16px; }.clini-prod-note { background:#FFF7ED; border:1px solid #FDBA74; border-radius:8px; padding:12px 16px; font-size:13px; color:#7C2D12; margin:16px 0; }.clini-trust { background:#f8fafc; border:1px solid #d1d5db; border-radius:12px; padding:20px; margin:20px 0; }.clini-trust h3 { margin:0 0 12px; font-size:1.1rem; color:#123a2f; }.clini-trust-grid { display:grid; grid-template-columns:1fr 1fr; gap:12px; }.clini-trust-item { background:#fff; border:1px solid #e5e7eb; border-radius:8px; padding:12px; }.clini-trust-item h4 { margin:0 0 4px; font-size:0.95rem; color:#206270; }.clini-trust-item p { margin:0; font-size:13px; color:#4b5563; line-height:1.5; }.clini-cert-row { display:flex; flex-wrap:wrap; gap:8px; margin-top:12px; }.clini-cert-chip { background:#e8f1f5; color:#123a2f; border-radius:20px; padding:5px 14px; font-size:12.5px; font-weight:600; }\n\u003c\/style\u003e\n\n\u003c!-- bi-family-crosslink v1 --\u003e\n\n\u003cp\u003e\u003cstrong\u003eHave a question about your own facility?\u003c\/strong\u003e Send it in and you will get a written answer specific to your setup, with the regulation or standard it is based on cited. \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003eAsk your compliance question\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eRelated tests in this BI line\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/dlab-hb120-s-led-digital-dry-bath-incubator\"\u003eDLAB HB105-S1 Dry-Bath Incubator with Lid — 20 wells, $599.00\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-clinic-starter-bundle-gloves-spore-testing-sterilization-packaging\"\u003eClinic Starter Bundle — Gloves, Spore Testing \u0026amp; Sterilization Packaging\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-1-hour-rapid-readout-50-pack\"\u003eCliniEco Medical Biological Indicator — 1-Hour Rapid Readout, Fluorescence, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-20-minute-rapid-readout-50-pack\"\u003eCliniEco Medical Biological Indicator — 20-Minute Rapid Readout, Fluorescence, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-100-pack\"\u003eCliniEco Medical Biological Indicator — 24-Hour Self-Contained, 100-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003eCliniEco Medical Biological Indicator — 24-Hour Self-Contained, 25-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-50-pack\"\u003eCliniEco Medical Biological Indicator — 24-Hour Self-Contained, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-3-hour-rapid-readout-fluorescence-50-pack\"\u003eCliniEco Medical Biological Indicator — 3-Hour Rapid Readout, Fluorescence, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-bowie-dick-test-pack-iso-11140-5-type-2-daily-vacuum-check-6-pack\"\u003eCliniEco Medical Bowie-Dick Test Pack — ISO 11140-5 Type 2, Daily Vacuum Check, 6-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-rapid-reader-4-well-fluorescence-biological-indicator-reader\"\u003eCliniEco Rapid Reader — 4-Well Fluorescence Biological Indicator Reader\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/24-hour-self-contained-biological-indicator-pack-sizes-incubation-record\"\u003e24-Hour Self-Contained Biological Indicators: Pack Sizes, Incubation and the Record\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/how-often-us-vs-canadian-clinics-sterilizer-testing-incubator-guide\"\u003eHow Often Must US vs Canadian Clinics Run Sterilizer Testing? 24-Hour Biological Indicator Incubator Ordering \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/which-standards-medical-biological-indicator-us-vs-canada\"\u003eWhich Standards Apply to Medical Biological Indicator in the US vs Canada? Sizes and Sourcing\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/which-standards-hb105-s2-dry-bath-incubator-us-vs-canada\"\u003eWhich Standards Apply to HB105-S1 Dry Bath Incubator with Lid in the US vs Canada? Sizes and Sourcing\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":48967661715678,"sku":"CLI-INC-24","price":379.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/INCUBATOR-24H-HERO-logo-20261110_4d747eac-4cbf-43ea-afea-8cc34776c101_c8ab695d-16a7-49b0-abbe-bec1f7e07064.jpg?v=1794342630"},{"product_id":"clinieco-benchtop-autoclave-class-b-coming-soon","title":"Benchtop Autoclave (Class B Steam Sterilizer) — Coming Soon","description":"\u003cdiv class=\"product-description\"\u003e\n\u003ch2\u003eWhat does a Class B pre-vacuum cycle change for a clinic?\u003c\/h2\u003e\n\u003cp\u003eA gravity cycle pushes steam in and lets air out; a pre-vacuum cycle pulls air out first, which is what allows wrapped, hollow and porous loads to be sterilised reliably. That is why Class B benchtop units are the format dental clinics, veterinary practices, med-spas and tattoo studios look at: the loads those rooms actually run are wrapped and hollow, not open instruments on a tray.\u003c\/p\u003e\n\u003ch2\u003eWhat has to be true before a benchtop unit goes into service?\u003c\/h2\u003e\n\u003cp\u003eThree things, and none of them are optional: the unit has to be validated for the load types the clinic runs, the monitoring schedule has to be in place from the first cycle, and the records have to survive an inspection. In Ontario, the dental regulator's infection-control standard sets the expectation for sterilisation monitoring; the practical version is a biological indicator on every day the unit runs, plus chemical indicators in every pack and a record of both.\u003c\/p\u003e\n\u003ch2\u003eWhere does this unit sit in that programme?\u003c\/h2\u003e\n\u003cp\u003eIt does not publish chamber volume, cycle times or the licensing position, and a clinic should not plan an equipment replacement around a date that has not been confirmed. What can be done now is the part that takes longer than the purchase: the monitoring routine and the record keeping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFormat:\u003c\/strong\u003e Benchtop steam steriliser, pre-vacuum Class B cycle\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLoad types:\u003c\/strong\u003e Wrapped, hollow and porous loads\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntended settings:\u003c\/strong\u003e Dental clinics, veterinary practices, med-spas, tattoo studios\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMonitoring expectation:\u003c\/strong\u003e Biological indicator each day the unit runs, chemical indicator in every pack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDistribution:\u003c\/strong\u003e CliniEco Medical — MDEL #35334\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFormat:\u003c\/strong\u003e Benchtop steam steriliser, pre-vacuum Class B cycle\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLoad types:\u003c\/strong\u003e Wrapped, hollow and porous loads\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntended settings:\u003c\/strong\u003e Dental clinics, veterinary practices, med-spas, tattoo studios\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMonitoring expectation:\u003c\/strong\u003e Biological indicator each day the unit runs, chemical indicator in every pack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDistribution:\u003c\/strong\u003e CliniEco Medical — MDEL #35334\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eBenchtop steam steriliser — planned specification as listed\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003ePlanned \/ stated\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eBenchtop steam steriliser, pre-vacuum Class B cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad types\u003c\/td\u003e\n\u003ctd\u003eWrapped, hollow and porous loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended settings\u003c\/td\u003e\n\u003ctd\u003eDental clinics, veterinary practices, med-spas, tattoo studios\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChamber volume\u003c\/td\u003e\n\u003ctd\u003eNot stated on the listing — confirmed before release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCycle times\u003c\/td\u003e\n\u003ctd\u003eNot stated on the listing — confirmed before release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring expectation\u003c\/td\u003e\n\u003ctd\u003eBiological indicator each day the unit runs, chemical indicator in every pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003ctd\u003eCliniEco Medical — MDEL #35334\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhat does the monitoring programme need on the shelf?\u003c\/h2\u003e\n\u003cp\u003eA \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-50-pack\"\u003e24-hour self-contained biological indicator, fifty per pack\u003c\/a\u003e covers daily spore testing, and a \u003ca href=\"\/en-us\/products\/clinieco-medical-bowie-dick-test-pack-iso-11140-5-type-2-daily-vacuum-check-6-pack\"\u003eBowie-Dick test pack to ISO 11140-5 Type 2\u003c\/a\u003e is the daily vacuum check a pre-vacuum unit needs before the first load. For packaging, the \u003ca href=\"\/en-us\/products\/clinieco-sterilization-pouch-class-4-self-sealing-dual-indicator-200-per-box\"\u003eClass 4 self-sealing pouch with dual indicators, two hundred per box\u003c\/a\u003e is the consumable that keeps the routine running. Log sheets print from the \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003ecompliance log centre\u003c\/a\u003e and can be generated with the sterilization log generator on that page; clinic quantities are quoted at \u003ca href=\"\/en-us\/pages\/wholesale\"\u003ethe clinic ordering desk\u003c\/a\u003e, and the monitoring question itself can be booked with \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003ethe compliance desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eImported and distributed in Canada by CliniEco Medical — MDEL #35334.\u003c\/p\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eCliniEco Medical is preparing to introduce a \u003cstrong\u003ebenchtop Class B steam sterilizer (autoclave)\u003c\/strong\u003e for Canadian dental clinics, veterinary practices, med-spas, and tattoo studios. Class B pre-vacuum technology delivers validated sterilization for wrapped, hollow, and porous loads — the same standard trusted by modern clinics.\u003c\/p\u003e\n\u003ch2\u003eWhy Wait for Our Autoclave?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance-first\u003c\/strong\u003e — sourced from manufacturers holding Canadian Medical Device Licence (Class II) and FDA 510(k) clearance; distributed by CliniEco Medical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne-stop sterilization room\u003c\/strong\u003e — pairs with our sterilization pouches, rolls, Class 4\/5 indicators, biological indicators (BI) and monitoring equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal support\u003c\/strong\u003e — Toronto warehouse, Canadian-based distributor, full documentation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen consumables ecosystem\u003c\/strong\u003e — works with standard sterilization pouches\/tape\/BI on the market (no lock-in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAvailability\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWe are currently completing model selection and sample validation. Expected retail range CAD $3,500–$4,500 depending on model (final pricing TBD at launch).\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo be notified at launch or to discuss bulk\/group pricing for multi-chair clinics, contact us at \u003ca href=\"mailto:alina@clinieco.ca\"\u003ealina@clinieco.ca\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- sterilization-system-links --\u003e\n\u003cdiv style=\"max-width:820px;margin:28px auto 8px;padding:16px 20px;border:1px solid #e2e8f0;border-radius:12px;background:#f8fafc\"\u003e\n\u003cp style=\"margin:0 0 10px;font-weight:700;color:#206270;font-size:15px\"\u003ePart of the same sterilization system\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px;line-height:1.9;font-size:15px;color:#334155\"\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003e24-Hour Biological Indicators — 25-Pack\u003c\/a\u003e — $69.99\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-us\/products\/clinieco-24-hour-biological-indicator-incubator-precision-dry-block-15-wells\"\u003e24-Hour BI Incubator — Dry-Block\u003c\/a\u003e — $379.00\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-us\/products\/clinieco-sterilization-pouch-class-4-self-sealing-dual-indicator-200-per-box\"\u003eSterilization Pouches — Class 4, Assorted 200-Pack\u003c\/a\u003e — $11.99 (case of 10 — $95.92)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/which-benchtop-autoclave-class-b-british-columbia-spd\"\u003eWhich Benchtop Autoclave (Class B Steam Sterilizer) Do Hospital Sterile Processing Departments in British Colu\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/iso-15882-chemical-indicator-selection-storage-reading\"\u003eISO 15882 in Practice: Selecting, Storing and Reading Chemical Indicators\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":48987217723614,"sku":"CLI-AUTOCLAVE-CB-COMING","price":3999.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/01_main_white_clean_c8ce08af-0c80-47fc-a177-7bb5de0f203a.jpg?v=1791271772"},{"product_id":"clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency","title":"Ultrasonic Dental Cleaner CS6.2 — 6 L Benchtop, Dual-Frequency 32\/48kHz, for Instrument Cassettes | CliniEco Medical","description":"\u003ch3\u003eThe cleaner that takes a full instrument cassette\u003c\/h3\u003e\n\u003cp\u003eMost benchtop ultrasonic cleaners sold online are built for jewellery, glasses and dentures. They are small, they are cheap, and they cannot take a standard dental instrument cassette — which means someone at your practice ends up running them in loose batches, twice.\u003c\/p\u003e\n\u003c!-- ce-glance:CS6.2 --\u003e\n\u003cdiv class=\"ce-glance\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e6 L\u003c\/strong\u003e stainless steel tank · dual frequency 32 \/ 48 kHz · 320 W · AC 100–120 V \/ 60 Hz · cETL certified by Intertek to CSA C22.2 No. 68 and UL 73.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003eA full dental instrument cassette fits in one cycle, lid closed, instruments still in the rack. All sizes, 4 L to 20 L: \u003ca href=\"\/en-us\/collections\/ultrasonic-cleaners\"\u003eultrasonic cleaners and enzyme solution for dental practices in Canada\u003c\/a\u003e.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHow to order\u003c\/th\u003e\n\u003ctd\u003eShips from Toronto, Ontario. Order a single unit online, or by purchase order through \u003ca href=\"\/en-us\/pages\/wholesale\"\u003ewholesale and institutional ordering\u003c\/a\u003e. Current lead time for this model is confirmed before dispatch.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp\u003eIf you are looking for an ultrasonic dental cleaner that takes a full cassette, the CS6.2 is the 6 L class answer: it is a dental ultrasonic cleaner built for dental instrument reprocessing, not for jewellery, glasses or retainers. It is also the ultrasonic cleaner for dental instruments that clinics ask for when their old unit was sized for a countertop, not for a cassette.\u003c\/p\u003e\n\u003cp\u003eThe CS6.2 is a \u003cstrong\u003e6 L class\u003c\/strong\u003e unit. That is the size at which a full cassette fits in one cycle, which is the whole point of having a cleaner on the bench.\u003c\/p\u003e\n\u003cp\u003ecETL certified by Intertek to \u003cstrong\u003eCSA C22.2 No. 68\u003c\/strong\u003e and \u003cstrong\u003eUL 73\u003c\/strong\u003e. CliniEco Medical is a Canadian importer based in Toronto — ask us for the current lead time.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/where-to-buy-dental-ultrasonic-cleaner-dental-clinics-nova-scotia\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/599bf33f4da20fb38d1771bb70a76d19.png?v=1792815581\" alt=\"CliniEco Dental Ultrasonic Cleaner — 6 L Benchtop, CS6.2 Dual-Frequency 32\/48kHz\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eAlready running an ultrasonic bath and reordering solution?\u003c\/h3\u003e\n\u003cp\u003eIf you are buying cleaning solution by the jug, there is already a tank on your bench. The question is no longer whether to run an ultrasonic bath — it is whether that tank is the right size and the right frequency for the load going into it.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eA 6 L class tank.\u003c\/strong\u003e A full instrument cassette fits in a single cycle, so the same load does not get run twice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual frequency, 32 kHz and 48 kHz.\u003c\/strong\u003e 32 kHz for heavier soils, 48 kHz for fine crevices — one unit covers the whole load instead of making you pick one.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat, timer and basket included.\u003c\/strong\u003e Ceramic heaters take the solution to 40–60 °C, the digital timer runs to 30 minutes with a 120 s degas cycle, and the SB01 stainless basket ships with the unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSolution is a running cost that keeps coming back. The unit is a one-time purchase that decides how well that solution works — and if the tank on your bench is the wrong size or the wrong frequency for your cassette, replacing it is the more practical path than working around it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdd the CS6.2 to your cart above\u003c\/strong\u003e, or send us your cassette count and we will tell you whether 6 L is the right size for your room.\u003c\/p\u003e\n\u003ch2\u003eWhat does the CS6.2 cost, and what comes with the unit at that price?\u003c\/h2\u003e\n\u003cp\u003eThe cleaner is a single SKU at $699.00, basket included. That basket is part SB01 and can be re-ordered on its own once it wears, so a replacement does not mean a new machine. At the listed figure you get the 6 L tank, the dual-frequency generator, two ceramic heaters and the digital timer; nothing in the table below is an add-on. Consumables sit outside that price: the \u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003eenzyme cleaning solution\u003c\/a\u003e is what goes in the tank, sold by the 4 L container.\u003c\/p\u003e\n\u003ch2\u003eDoes this unit log cleaning cycles?\u003c\/h2\u003e\n\u003cp\u003eNo. The CS6.2 has no internal data logger and cannot export cycle data to a USB drive or a CSV file. If your reprocessing protocol requires machine-generated cycle records, choose a unit built for that purpose — this model is not one.\u003c\/p\u003e\n\u003cp\u003eWhat the CS6.2 gives you instead is everything needed to keep a defensible manual record: a front-panel timer that counts the cycle, a temperature set-point you can read and write down, and a drain valve so the solution-change date is unambiguous. Under CSA Z314:23 the documentation obligation sits inside your reprocessing quality system rather than inside the appliance, so a signed paper log is not a lesser record — it is the record the standard asks for.\u003c\/p\u003e\n\u003cp\u003eFive fields per cycle is enough: date, operator, temperature set-point, cycle length, and the date the solution was last changed. One line, end of shift.\u003c\/p\u003e\n\u003ch2\u003eWill a 6 L tank take a full instrument cassette?\u003c\/h2\u003e\n\u003cp\u003eYes, and that is the size break the CS6.2 is built around. Tank dimensions are 31.1 × 17.2 × 11.6 cm, the footprint a standard dental cassette needs; under 3 L you are either unpacking instruments or running two cycles. Above 6 L the units are bought for several cassettes and longer runs, and they cost two to three times more, which is why a single-surgery practice rarely needs one. Instruments go in the basket or the cassette — never piled on the tank floor, because metal resting on metal blocks the cavitation underneath.\u003c\/p\u003e\n\u003ch2\u003eDoes a benchtop ultrasonic cleaner sterilise instruments, or only clean them?\u003c\/h2\u003e\n\u003cp\u003eIt cleans, and it does not sterilise. An ultrasonic cycle lifts soil — cement residue, polishing paste, dried blood from hinges — and that step comes before pouching and the autoclave, never in place of it. The 32 kHz setting drives larger bubbles for heavier soil, 48 kHz drives smaller ones into lumens and threaded joints, and the 120-second degas cycle at the start is what keeps the first load of the day behaving like the fourth. What the unit does carry is electrical certification: cETL by Intertek to CSA C22.2 No. 68 and UL 73.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCS6.2 6 L benchtop ultrasonic cleaner — tank, frequencies, certification and price\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eField\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTank capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTank dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.1 × 17.2 × 11.6 cm, SUS304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual — 32 kHz and 48 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 W total; two transducers at 80 W or less each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating and timer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo ceramic heaters, 40–60 °C selectable; digital timer with 120 s degas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ecETL by Intertek to CSA C22.2 No. 68 and UL 73\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC 100–120 V \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCLI-ULTRA-CLEAN-62 — $699.00, basket SB01 included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCleaning records for the reprocessing room print from the \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003ecompliance log centre\u003c\/a\u003e, and the log generator on that page fills the date row for each station; fitting a new unit into an existing workflow is the kind of question the \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003esterilization compliance consultation\u003c\/a\u003e answers. This cleaner is imported into Canada by CliniEco Medical, MDEL #35334.\u003c\/p\u003e\n\u003ch3\u003eWhy the 6 L class is the one that matters\u003c\/h3\u003e\n\u003cp\u003eInstrument cassettes are the standard way dental practices sterilise. If your cleaner cannot take the cassette, you are either unpacking instruments to clean them or running two cycles, and both cost you time every single day.\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTank capacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eWhat fits\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eWho it suits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eUnder 3 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eHandpieces, retainers, loupes\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eFront desk, ortho, solo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003e6 L (this unit)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eA full instrument cassette\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eGeneral practice, hygiene\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e8 L and up\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eMultiple cassettes, larger runs\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eHigh-volume, labs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis is one of the two sizes Canadian dental practices buy most. The larger units in this range cost two to three times more, which is why most single-surgery practices stay in this class.\u003c\/p\u003e\n\u003ch3\u003eCertification you can actually check\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eElectrical certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\n\u003cstrong\u003ecETL (Intertek)\u003c\/strong\u003e, to \u003cstrong\u003eCSA C22.2 No. 68\u003c\/strong\u003e and \u003cstrong\u003eUL 73\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\n\u003cstrong\u003eAC 100–120 V \/ 60 Hz\u003c\/strong\u003e — North American supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eProduct code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\n\u003cstrong\u003eCS6.2\u003c\/strong\u003e — the manufacturer's model number, printed on the unit nameplate and on the carton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eImporter of record\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\n\u003cstrong\u003eCliniEco Medical\u003c\/strong\u003e — Health Canada \u003cstrong\u003eMDEL #35334\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eManufactured by an OEM whose units are already in service with major North American dental distributors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eMany low-cost units sold online carry FCC, CE and RoHS only. Those are not electrical safety certifications, and a unit without an NRTL mark should not be installed in a commercial setting under the Ontario Electrical Safety Code. If you are being asked to sign off on a clinic, that distinction is the one that matters.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px\"\u003eTank capacity\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px\"\u003e\n\u003cstrong\u003e6 L\u003c\/strong\u003e (6 L class)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTank dimensions\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003e31.1 × 17.2 × 11.6 cm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eCleaning frequency\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eDual frequency — 32 kHz \/ 48 kHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTransducers\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e2 × industrial-grade, ≤ 80 W each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eTotal power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003e320 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eHeating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003e2 × ceramic heaters, 40–60 °C (selectable)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eDegassing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\n\u003cstrong\u003e120 s cycle\u003c\/strong\u003e (removes dissolved air that blunts cavitation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTimer\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eDigital, with heater control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTank \u0026amp; basket\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eSUS304 stainless steel, with a removable basket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eHousing (external shell)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eAluminium alloy + ABS — external only; never immersed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eUnit weight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eapprox. \u003cstrong\u003e9.2 kg\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eAC 100–120 V \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eCertification\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003ecETL (Intertek) · CSA C22.2 No. 68 · UL 73\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eElectrical safety report\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eIntertek \u003cstrong\u003e220112140GZU-001\u003c\/strong\u003e — applicable to model CS6.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eBasket part code\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eStainless steel basket \u003cstrong\u003eSB01\u003c\/strong\u003e (replaceable \/ re-orderable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhat the dual frequency actually does for you\u003c\/h3\u003e\n\u003cp\u003eCavitation behaves differently at different frequencies, and this is not a marketing line — it is physics.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e32 kHz\u003c\/strong\u003e — larger, more energetic bubbles. Better at lifting heavier soils: cement residue, polishing paste, dried blood on hinged instruments.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e48 kHz\u003c\/strong\u003e — smaller, denser bubbles. Gentler, and it reaches into fine crevices, lumens and threaded joints without the erosion risk that aggressive low-frequency cavitation can cause on plated instruments.\u003c\/p\u003e\n\u003cp\u003eRunning both means one machine covers the whole load rather than forcing you to choose between \"heavy soil\" and \"delicate instrument\".\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDegassing matters more than people expect.\u003c\/strong\u003e Freshly filled tap water is saturated with dissolved air, and dissolved air absorbs the energy that should be forming cavitation bubbles. A 120-second degas cycle at the start is why the first load of the day performs like the fourth.\u003c\/p\u003e\n\u003ch3\u003eIn use\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eFill\u003c\/strong\u003e to the marked level, add the cleaning solution, and run the \u003cstrong\u003e120 s degas\u003c\/strong\u003e cycle.\u003c\/p\u003e\n\u003cp\u003e2. \u003cstrong\u003eHeat\u003c\/strong\u003e to 40–60 °C (selectable). Warm solution measurably improves soil removal.\u003c\/p\u003e\n\u003cp\u003e3. \u003cstrong\u003eLoad\u003c\/strong\u003e — instruments in the basket or cassette, not piled on the tank floor. Cavitation is blocked by contact surfaces.\u003c\/p\u003e\n\u003cp\u003e4. \u003cstrong\u003eRun\u003c\/strong\u003e the cycle, then \u003cstrong\u003erinse\u003c\/strong\u003e and inspect before sterilisation.\u003c\/p\u003e\n\u003cp\u003e5. \u003cstrong\u003eEmpty and dry\u003c\/strong\u003e the tank. Leaving solution in overnight is what shortens the life of the transducer plate.\u003c\/p\u003e\n\u003ch3\u003eConsumables that go with it\u003c\/h3\u003e\n\u003cp\u003eUltrasonic cleaning is a consumable line, not a one-off purchase.\u003c\/p\u003e\n\u003cp\u003e• \u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003e\u003cstrong\u003eEnzymatic ultrasonic cleaning solution\u003c\/strong\u003e\u003c\/a\u003e — 4 L concentrate. The right chemistry does more work than a longer cycle.\u003c\/p\u003e\n\u003cp\u003e• \u003ca href=\"\/en-us\/collections\/dental-sterilization-essentials\"\u003e\u003cstrong\u003eSterilisation pouches, indicator tape and biological indicators\u003c\/strong\u003e\u003c\/a\u003e — for the steps after the cleaner.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e(We also supply the consumables above. Bundling them with the unit is how most practices run it.)\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eOrdering\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e$699.00.\u003c\/strong\u003e CliniEco Medical, Toronto, Ontario. Ask us for the current lead time before you order.\u003c\/p\u003e\n\u003cp\u003eCliniEco Medical is the importer of record: \u003cstrong\u003eEcology Source New Energy Technology Co., LTD. o\/a CliniEco Medical\u003c\/strong\u003e, Health Canada \u003cstrong\u003eMDEL #35334\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eQuestions about whether this is the right size for your practice — tell us how many cassettes you run per day and we will tell you straight, even if the answer is that you do not need this one.\u003c\/p\u003e\u003ch3\u003eStraight answers — including the things you may not want to hear\u003c\/h3\u003e\n\u003cp\u003eMost listings in this category skip the awkward parts. We do not, because the awkward parts are usually what decides the purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat this unit will not do.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIt will not clean aluminium or anodised instruments.\u003c\/strong\u003e No ultrasonic cleaner will. Anodised coatings and bare aluminium are attacked by the cavitation and by alkaline cleaning solutions. If you use aluminium trays or anodised cassettes, do not put them in any ultrasonic bath. This refers to what you place in the bath — the unit's own housing is aluminium alloy and sits outside the tank, so it is never immersed.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIt will not clean the inside of a narrow lumen on its own.\u003c\/strong\u003e Ultrasonic energy does not travel well down a small-diameter channel. Lumens and hinges need a brush as well — this is true of every unit at every price.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIt does not replace gross decontamination.\u003c\/strong\u003e Heavy debris should be wiped or rinsed off first. Solution life and cleaning performance both drop if you do not.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIt does not sterilise.\u003c\/strong\u003e This is a cleaner. Sterilisation is a separate step, in a separate machine.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat we can state plainly, that others often will not.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eThe tank holds 6 litres, and it measures 31.1 × 17.2 × 11.6 cm.\u003c\/strong\u003e Take a tape measure to your cassette before you buy. We would rather you check and not order than order and be disappointed.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eThe capacity figure is the real tank volume, not a model number.\u003c\/strong\u003e The model is CS6.2. The tank is 6 litres.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eThe electrical certification is cETL, to CSA C22.2 No. 68 and UL 73, issued by Intertek.\u003c\/strong\u003e We name the standard and the issuer so you can verify it. A product that says only \"FCC, CE and RoHS\" is telling you it holds no North American electrical safety certification — those three are emissions and materials marks, not safety marks, and a unit without an NRTL mark has no business being installed in a commercial setting.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eWe are the importer of record.\u003c\/strong\u003e Ecology Source New Energy Technology Co., LTD. o\/a CliniEco Medical, Health Canada MDEL #35334. That is on the label and on the paperwork, and it is who you hold responsible.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIt is not a no-name import.\u003c\/strong\u003e The unit is built by a manufacturer that also produces cleaners for established North American dental brands, and it ships with the manufacturer's own nameplate.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIf it is the wrong size for you, we will say so.\u003c\/strong\u003e Tell us how many cassettes you run per day and what instruments you put through them, and we will answer honestly — including when the honest answer is that you need a larger tank or a different machine.\u003c\/p\u003e\n\u003ch3\u003eSpecifications you can hold us to\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eTank capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\n\u003cstrong\u003e6 litres\u003c\/strong\u003e (model CS6.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTank dimensions\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e31.1 × 17.2 × 11.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eDual — 32 kHz \/ 48 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTransducers\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e2 × industrial grade, ≤ 80 W each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTotal power\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e320 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eHeating\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e2 × ceramic, 40–60 °C (selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eDegassing\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eAC 100–120 V \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eapprox. 9.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eCertification\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003ecETL (Intertek) · CSA C22.2 No. 68 · UL 73\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eImporter\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eCliniEco Medical — Health Canada MDEL #35334\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003eHave a question about your own facility?\u003c\/strong\u003e Send it in and you will get a written answer specific to your setup, with the regulation or standard it is based on cited. \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003eAsk your compliance question\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eChoosing the right option for your clinic\u003c\/h2\u003e\n\u003cp\u003eBefore you order, the decisions that actually change the result are tank size against instrument load, what 32\/48 kHz dual frequency changes, and how to document proof of clean. The full buyer's guide covers them step by step: \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/ultrasonic-cleaner-canadian-clinic-tank-frequency-proof-of-clean\"\u003eUltrasonic Cleaner for a Canadian Clinic: Tank, Frequency and Proof of Clean\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eRelated supplies for the same workflow\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003elow-foam multi-enzyme ultrasonic cleaning solution, 1 L \/ 5 L\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-constant-heat-pouch-sealer-200-c-12mm-seal-110v-dental-sterilization\"\u003econstant-heat pouch sealer, 200 °C, 12 mm seal\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-sterilization-pouch-class-4-self-sealing-dual-indicator-200-per-box\"\u003eClass 4 self-sealing sterilization pouches, 200 per box\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate__pos01_noprice.png?v=1790001406\" alt=\"CliniEco multi-enzyme ultrasonic cleaning solution\" loading=\"lazy\" width=\"480\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eTwo units available in Toronto — ships immediately.\u003c\/strong\u003e Further units ship within one week of payment. Need it for a specific install date? Ask us and we will confirm before you pay.\u003c\/p\u003e\n\u003ch2\u003eHow many instrument cassettes can one 6 L tank get through in a day?\u003c\/h2\u003e\n\u003cp\u003eOne cassette per cycle, because that is what the tank is sized for: 31.1 × 17.2 × 11.6 cm takes a full dental instrument cassette laid flat, and the SB01 basket ships with the unit so the load comes out in one lift. The cycle is whatever you set on the digital timer, which runs to 30 minutes with a 120 s degas phase at the start, while the two ceramic heaters hold the solution in the 40–60 °C band.\u003c\/p\u003e\n\u003cp\u003eSo the daily arithmetic is cycles rather than cassettes. Four cycles in a morning and three in the afternoon is seven cassettes in a day, and the 6 L tank is the reason each of those cycles carries a whole cassette instead of a loose tray. Nothing here batches two cassettes at once: one cassette is what fills the tank usefully, and that is the honest limit of this size.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCycles you run in a day\u003c\/th\u003e\n\u003cth\u003eCassettes cleaned\u003c\/th\u003e\n\u003cth\u003eWhat that rhythm looks like\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2–3\u003c\/td\u003e\n\u003ctd\u003e2–3\u003c\/td\u003e\n\u003ctd\u003eA single surgery with a light morning list\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4–6\u003c\/td\u003e\n\u003ctd\u003e4–6\u003c\/td\u003e\n\u003ctd\u003eOne dentist and one hygienist with turnover between patients\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7–10\u003c\/td\u003e\n\u003ctd\u003e7–10\u003c\/td\u003e\n\u003ctd\u003eTwo chairs running, or a surgical list in the middle of the day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMore than 10\u003c\/td\u003e\n\u003ctd\u003e10+\u003c\/td\u003e\n\u003ctd\u003eNow the queue, not the tank, is the constraint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIn the last row the question is no longer whether 6 L is enough — the unit still cleans one cassette per cycle — but whether the room wants two cleaners on two benches so a second cassette can run while the first is being rinsed. Tell us the cassette count per day and we will say which of those two problems you actually have.\u003c\/p\u003e\n\n\u003ch2\u003eWhat has to be true of the room before the unit goes on the bench?\u003c\/h2\u003e\n\u003cp\u003eFour things, and all four are checkable before the carton is opened. The electrical side is the one that fails an inspection: the unit runs from a standard North American supply at AC 100–120 V \/ 60 Hz, with 320 W of total load across the transducers and heaters — roughly 2.7 A at 120 V, an ordinary branch circuit rather than anything special, but a unit without its cETL mark still should not be installed in a commercial setting.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003cth\u003eWhere the figure comes from\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceptacle\u003c\/td\u003e\n\u003ctd\u003eAC 100–120 V \/ 60 Hz, standard North American outlet\u003c\/td\u003e\n\u003ctd\u003eRating on the unit nameplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit load\u003c\/td\u003e\n\u003ctd\u003e320 W total, about 2.7 A at 120 V (derived from rated power)\u003c\/td\u003e\n\u003ctd\u003eTwo transducers ≤ 80 W each plus two ceramic heaters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety mark\u003c\/td\u003e\n\u003ctd\u003ecETL by Intertek, to CSA C22.2 No. 68 and UL 73\u003c\/td\u003e\n\u003ctd\u003eIntertek report 220112140GZU-001, applicable to model CS6.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBench space\u003c\/td\u003e\n\u003ctd\u003e31.1 × 17.2 cm of tank, plus room to lift the basket clear\u003c\/td\u003e\n\u003ctd\u003eTank dimensions and removable SB01 basket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain and dry-down\u003c\/td\u003e\n\u003ctd\u003eAbility to empty and dry the tank at the end of the day\u003c\/td\u003e\n\u003ctd\u003eSolution is changed daily and not left in the tank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe unit weighs approximately 9.2 kg empty, so it is a benchtop appliance one person can move, not a plumbed installation: no water connection, no drain line. You fill to the marked level and you empty it at the end of the day.\u003c\/p\u003e\n\n\u003ch2\u003eWhat belongs in an ultrasonic bath, and what must stay out?\u003c\/h2\u003e\n\u003cp\u003eThis is the part that decides whether the cleaner helps or quietly damages an instrument stock, and the answer is the same for every ultrasonic unit at every price. What changes with this machine is that 48 kHz gives a gentler cavitation field for plated and hinged work, so the question becomes which load goes in which cycle.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad\u003c\/th\u003e\n\u003cth\u003eIn the bath?\u003c\/th\u003e\n\u003cth\u003eWhat to watch\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStainless cassettes, loaded\u003c\/td\u003e\n\u003ctd\u003eYes — the load this tank is sized for\u003c\/td\u003e\n\u003ctd\u003eLay flat in the basket; never on the tank floor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHinged and plated instruments\u003c\/td\u003e\n\u003ctd\u003eYes, on the 48 kHz setting\u003c\/td\u003e\n\u003ctd\u003eKeep them from touching each other — contact surfaces block cavitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLumens and threaded joints\u003c\/td\u003e\n\u003ctd\u003eYes, plus a brush\u003c\/td\u003e\n\u003ctd\u003eUltrasonic energy does not travel down a narrow channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAluminium and anodised instruments or trays\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eCavitation and alkaline solutions attack both — true of any ultrasonic bath\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeavily soiled instruments from the chair\u003c\/td\u003e\n\u003ctd\u003eOnly after gross decontamination\u003c\/td\u003e\n\u003ctd\u003eHeavy debris shortens solution life and blunts the cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnything the instrument maker says not to immerse\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eThe instrument's reprocessing instructions come before any cleaner setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe housing of the CS6.2 is aluminium alloy and ABS, which is worth reading twice: the aluminium warning applies to what goes into the tank, not to the machine, whose shell sits outside the bath and is never immersed.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does the routine look like, day by day?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eWhen\u003c\/th\u003e\n\u003cth\u003eTask\u003c\/th\u003e\n\u003cth\u003eWhy it matters\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStart of day\u003c\/td\u003e\n\u003ctd\u003eFill, add solution, run the 120 s degas cycle\u003c\/td\u003e\n\u003ctd\u003eFresh tap water is saturated with dissolved air, which absorbs the energy that should form cavitation bubbles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBefore the first load\u003c\/td\u003e\n\u003ctd\u003eHeat the solution into the 40–60 °C band\u003c\/td\u003e\n\u003ctd\u003eWarm solution removes soil measurably better than cold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvery cycle\u003c\/td\u003e\n\u003ctd\u003eLoad in the basket or cassette, never piled on the floor\u003c\/td\u003e\n\u003ctd\u003eMetal on metal blocks cavitation underneath\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAfter every cycle\u003c\/td\u003e\n\u003ctd\u003eRinse and inspect before pouching\u003c\/td\u003e\n\u003ctd\u003eThe cleaner lifts soil; inspection is the check that the lift happened\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDaily, or sooner if soiled\u003c\/td\u003e\n\u003ctd\u003eChange the solution\u003c\/td\u003e\n\u003ctd\u003eThe most common reason practices report poor cleaning results\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnd of day\u003c\/td\u003e\n\u003ctd\u003eEmpty and dry the tank\u003c\/td\u003e\n\u003ctd\u003eSolution left overnight is what shortens the life of the transducer plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhen the basket wears\u003c\/td\u003e\n\u003ctd\u003eRe-order the SB01 basket\u003c\/td\u003e\n\u003ctd\u003eThe basket is a part number, not a consumable of the machine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTwo questions that come in before an order, answered here rather than saved for a call. The tank cannot take two cassettes at once: 31.1 × 17.2 cm of floor plus a 6 litre volume means one cassette fills it usefully, and two would sit against each other and against the walls — the exact contact pattern that ruins a cavitation field. And the heater is not something you stand over: it is controlled from the same panel as the timer, the band is selectable between 40 and 60 °C, and the unit holds the setting for the length of the cycle. What the unit does not do is log the cycle, so the temperature and time record for your reprocessing file is written on the room's own log.\u003c\/p\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":49011615105246,"sku":"CLI-ULTRA-CLEAN-62","price":699.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CS6.2-HERO-logo-20261110_645f5324-e5e4-4ce8-abd2-63c9038be8b5.jpg?v=1794342702"},{"product_id":"dlab-hb120-s-led-digital-dry-bath-incubator","title":"Biological Indicator Incubator - DLAB HB105-S1 Dry Bath, 20-Well, 56-60 C, 24-Hour Readout","description":"\u003cdiv style=\"border:1px solid #d8e3e6;border-radius:10px;padding:22px 24px;margin:0 0 26px;background:#FFFFFF;\"\u003e\n\u003cp style=\"margin:0 0 8px;font-size:11px;font-weight:700;letter-spacing:.12em;text-transform:uppercase;color:#206270;\"\u003eFOR STERILITY ASSURANCE PROGRAMMES\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/dlab-hb105-s2-dry-bath-incubator-alberta-spd\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/01_hero_front_closed.jpg?v=1793235743\" alt=\"DLAB HB105-S1 Dry Bath Incubator with Lid — 20-Well, 24-Hour Biological Indicator Incubation\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 style=\"margin:0 0 12px;font-size:25px;line-height:1.28;font-weight:700;color:#12303a;\"\u003eLaboratory-grade dry-block incubation, built for the audit rather than the brochure.\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 16px;font-size:15.5px;line-height:1.65;color:#33454e;\"\u003eHolds self-contained biological indicators at 56–60 °C for the full 24-hour readout, with control accuracy of ±0.3 °C from 25 °C to 90 °C and ±0.6 °C from 90 °C to 105 °C, and no water bath to fill, change or contaminate.\u003c\/p\u003e\n\u003cdiv style=\"border-left:4px solid #1f6f5c;background:#f2f8f6;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cp style=\"margin:0;\"\u003e\u003cb\u003eLaunch offer — 50 biological indicators included\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"margin:8px 0 0;\"\u003eEvery incubator in this launch batch ships with \u003cb\u003e50 × 24-hour biological indicators\u003c\/b\u003e (the 50-pack is listed at $109.99). At two indicators per sterilisation cycle that covers 25 cycles — enough to run a full spore-testing month while the machine is new.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cul style=\"margin:0 0 18px;padding-left:20px;font-size:14.5px;line-height:1.75;color:#33454e;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e25–90 °C: ±0.3 °C, 90–105 °C: ±0.6 °C control accuracy; ±0.2 °C uniformity at 37 °C\u003c\/strong\u003e — the temperature stability a sterility assurance file depends on.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne block, 20 wells at 11 mm\u003c\/strong\u003e — sized for standard self-contained vials (8 mm body, 10 mm cap) to ISO 11138-3, not a general-purpose dry bath.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupplied with a 20-well block for 8.8 mm tubes.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecTUVus certified\u003c\/strong\u003e — TÜV Rheinland certificate CU 72205506 0001, tested to UL 61010-1 and CAN\/CSA-C22.2 No. 61010-1-12; FCC Part 15 Subpart B and ICES-001 registrations on file.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;margin:0 0 16px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:9px 10px;background:#F1F6F7;color:#12303a;border-bottom:1px solid #d8e3e6;\"\u003eWhat an auditor asks\u003c\/th\u003e\n\u003cth style=\"text-align:left;padding:9px 10px;background:#F1F6F7;color:#12303a;border-bottom:1px solid #d8e3e6;\"\u003eWhat this unit answers\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 10px;border-bottom:1px solid #eaeff1;\"\u003eWas the indicator held at the required temperature for the whole readout?\u003c\/td\u003e\n\u003ctd style=\"padding:9px 10px;border-bottom:1px solid #eaeff1;\"\u003e56–60 °C held for 24 h, within ±0.3 °C, checked against an optional PT1000 reference probe.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 10px;border-bottom:1px solid #eaeff1;\"\u003eIs the indicator itself traceable?\u003c\/td\u003e\n\u003ctd style=\"padding:9px 10px;border-bottom:1px solid #eaeff1;\"\u003eEvery BI lot ships with a certificate of analysis stating the measured spore population and D-value.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 10px;border-bottom:1px solid #eaeff1;\"\u003eCan you produce the electrical safety documentation?\u003c\/td\u003e\n\u003ctd style=\"padding:9px 10px;border-bottom:1px solid #eaeff1;\"\u003ecTUVus certificate number, standards tested to, and FCC\/ICES registrations — supplied as documents, not as claims.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 10px;\"\u003eWhere is the temperature record kept?\u003c\/td\u003e\n\u003ctd style=\"padding:9px 10px;\"\u003e\n\u003cstrong\u003eOn your own load sheet.\u003c\/strong\u003e The display holds temperature and time, and this unit does not log or export data — we would rather tell you that here than have you find it after delivery.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin:0;font-size:13px;line-height:1.65;color:#5b6b73;\"\u003eThis is a dry-block incubator, not a reader and not a data logger. The result is read visually on the indicator — purple passes, yellow fails.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin:0 0 26px;\"\u003e\n\u003cp style=\"margin:0 0 6px;font-size:15px;color:#33454e;\"\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e DLAB HB105-S1 dry bath incubator with transparent lid\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px;font-size:15px;color:#33454e;\"\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e one block, 20 wells (5 × 4), 11 mm well diameter\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px;font-size:15px;color:#33454e;\"\u003e\u003cstrong\u003eTemperature range:\u003c\/strong\u003e room temperature +5 °C to 105 °C, 0.1 °C display resolution\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px;font-size:15px;color:#33454e;\"\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e 25–90 °C: ±0.3 °C, 90–105 °C: ±0.6 °C; uniformity ±0.2 °C at 37 °C; PT1000 external probe supported\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px;font-size:15px;color:#33454e;\"\u003e\u003cstrong\u003eTimer:\u003c\/strong\u003e 0 min to 99 h 59 min\u003c\/p\u003e\n\u003cp style=\"margin:0;font-size:15px;color:#33454e;\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 3.2 kg with the block fitted\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e this page previously covered the HB120-S (no lid). It now ships as the HB105-S1 with a transparent lid — same programme, same bundle, now 20 wells. Existing orders and links are unaffected.\u003c\/em\u003e\u003c\/p\u003e\u003cdiv class=\"clini-prod-section\" style=\"background:#f0f7ff;border:2px solid #206270;border-radius:10px;padding:16px;\"\u003e \u003ch2 style=\"font-size:1.05rem;color:#206270;margin:0 0 6px;\"\u003e🎁 Buy This Incubator — Get a Free 50-Pack of BIs\u003c\/h2\u003e \u003cp style=\"margin:0;font-size:14px;color:#333;\"\u003eOrder the incubator today and we'll include \u003cstrong\u003e50 spore tests (a $109.99 value)\u003c\/strong\u003e at no charge — start your daily monitoring from day one.\u003c\/p\u003e\n\u003cp style=\"margin:12px 0 0;font-size:14px;\"\u003e\u003ca href=\"https:\/\/clinieco.ca\/cart\/49214013014238:1,48983807688926:1\" style=\"display:inline-block;background:#206270;color:#ffffff;padding:11px 20px;border-radius:6px;text-decoration:none;font-weight:600;\"\u003eAdd incubator + free 50-pack\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:8px 0 0;font-size:12.5px;color:#555;\"\u003eThis button puts both items in your cart — the 50-pack shows at $0 and you pay only for the incubator. If you prefer, add the 50-pack yourself: the discount applies automatically to one 50-pack per order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eDLAB HB105-S1 LED Dry Bath Incubator with Lid — for 24-hour biological indicator incubation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA dry-block incubator built for sterility assurance programmes: hold self-contained biological indicator vials at 56–60 °C for the 24-hour readout, with no water bath and no separate reader to buy.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransparent lid for heat preservation\u003c\/strong\u003e — your vials sit in the block for a full 24 hours, and the lid keeps both the heat in and the dust out. The lid is closed by hand.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne heating block — 20 wells (5 rows × 4 columns)\u003c\/strong\u003e, enough for a day of spore tests plus their controls in a single batch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature uniformity ±0.2 °C at 37 °C\u003c\/strong\u003e, control accuracy ±0.3 °C from 25 °C to 90 °C and ±0.6 °C from 90 °C to 105 °C. Runs from room temperature +5 °C up to 105 °C, with 0.1 °C display resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupports a PT1000 external sensor\u003c\/strong\u003e, so you can read from a reference point rather than the block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTimer, 0 min to 99 h 59 min\u003c\/strong\u003e — set it and walk away.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecTUVus certified\u003c\/strong\u003e — cTUVus, TÜV Rheinland certificate CU 72205506 0001, tested to UL 61010-1 and CAN\/CSA-C22.2 No. 61010-1-12; FCC Part 15 Subpart B (registration AK 50495998 0001) and ICES-001:2006 (registration AK 50496013 0001). 115 V AC, 50\/60 Hz power supply (North American plug).\u003c\/li\u003e\n\u003cli\u003eOverheating protection. Manufacturer: DLAB Scientific Co., Ltd., Beijing. Sold in Canada by CliniEco Medical, Health Canada establishment licence MDEL #35334.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor biological indicator incubation\u003c\/strong\u003e\u003cbr\u003e\nIntended for steam-cycle biological indicators — Geobacillus stearothermophilus self-contained vials to ISO 11138-3 — incubated between 55 and 60 °C with a 24-hour readout. The 11 mm wells take vials with a body diameter of 8 mm and a cap diameter of 10 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat this unit does, and does not, do\u003c\/strong\u003e\u003cbr\u003e\nThe result is read visually on the indicator itself: the medium stays purple when the cycle passes and turns yellow on a failure. This unit is an incubator, not a reader — it does not interpret fluorescent or rapid-readout indicators, which require a fluorescence reader. It does not record or export data; temperature and time are shown on the LED display and are kept on your daily record sheet.\u003c\/p\u003e\n\u003ch2\u003eWhat does spore testing cost per year with this incubator?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003cth\u003eCost per test\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHB105-S1 dry bath incubator with lid (one-time)\u003c\/td\u003e\n\u003ctd\u003e$499.00\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003e24-hour self-contained biological indicator, 25-pack\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e$69.99\u003c\/td\u003e\n\u003ctd\u003e$2.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDaily monitoring on one sterilizer, 250 tests a year\u003c\/td\u003e\n\u003ctd\u003e$699.90 in indicators\u003c\/td\u003e\n\u003ctd\u003e$2.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFirst-year total for a single sterilizer is $499.00 for the incubator plus $699.90 in indicators, or $1,198.90; with the launch offer at the top of this page the first 50 indicators are included at no charge, which brings the first-year figure to $1,088.91. From the second year the annual cost is the indicators alone. The 250-test line assumes one test on each day the sterilizer is used, five days a week; a site running two sterilizers doubles the indicator line.\u003c\/p\u003e\n\n\u003ch2\u003eWhich biological indicators work in this incubator?\u003c\/h2\u003e\n\u003cp\u003eThis is a dry bath held at 56 to 60 °C for the 24-hour readout, which is the incubation condition self-contained \u003cem\u003eGeobacillus stearothermophilus\u003c\/em\u003e indicators to ISO 11138-3 are designed for. The 11 mm wells take vials with a body diameter of 8 mm and a cap diameter of 10 mm. Rapid-readout indicators — 1-hour, 3-hour and 20-minute fluorescence — are not incubated here; they need their own reader.\u003c\/p\u003e\n\n\u003ch2\u003eHow many indicators fit in one run, and is that enough?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating blocks\u003c\/td\u003e\n\u003ctd\u003eOne block, 20 wells (5 rows × 4 columns)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e11 mm diameter, for 8 mm vial body \/ 10 mm cap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003eRoom temperature +5 °C to 105 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl accuracy\u003c\/td\u003e\n\u003ctd\u003e25–90 °C: ±0.3 °C; 90–105 °C: ±0.6 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUniformity\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C at 37 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer\u003c\/td\u003e\n\u003ctd\u003e0 min to 99 h 59 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal sensor\u003c\/td\u003e\n\u003ctd\u003ePT1000 supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eAC 115 V, 50\/60 Hz, North American plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLid\u003c\/td\u003e\n\u003ctd\u003eTransparent, hand-closed — keeps heat in and dust out during the run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003ecTUVus, TÜV Rheinland certificate CU 72205506 0001 (UL 61010-1, CAN\/CSA-C22.2 No. 61010-1-12); FCC Part 15 Subpart B, registration AK 50495998 0001; ICES-001:2006, registration AK 50496013 0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTwenty wells take twenty vials in one batch: ten spore tests, each paired with its matching control — the pattern daily monitoring follows on a single sterilizer. A 25-pack therefore runs as two batches, which is why the launch offer ships the 50-pack with this unit. That matters because a 24-hour readout means the block is occupied for the whole day: if the batch does not fit, the results split across two days.\u003c\/p\u003e\n\n\u003ch2\u003eDo I need a reader with this incubator?\u003c\/h2\u003e\n\u003cp\u003eNo. A 24-hour colour-change indicator is read by eye — the medium stays purple when the cycle passes and turns yellow on a failure — and recorded on your daily log. A fluorescence reader is only needed for 1-hour, 3-hour and 20-minute rapid indicators, where the result is a machine reading. This unit does not record or export data; temperature and time are shown on the LED display and copied onto your record sheet — a printable daily log is available at \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003ethe compliance log centre\u003c\/a\u003e. For questions about which monitoring interval applies to your own sterilizers, \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003esend the question to a sterilization compliance specialist\u003c\/a\u003e and you get a written answer that cites the standard behind it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDocumentation\u003c\/strong\u003e\u003cbr\u003e\nEnglish user manual included, French on request. Manufacturer warranty terms are available on request. Not for household use.\u003c\/p\u003e\n\u003ch2\u003eChoosing the right option for your clinic\u003c\/h2\u003e\n\u003cp\u003eBefore you order, the decisions that actually change the result are well count, temperature band, calibration evidence, and what an incubator you cannot defend costs at audit. The full buyer's guide covers them step by step: \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/how-to-choose-biological-indicator-incubator-canadian-clinic\"\u003eHow to Choose a Biological Indicator Incubator for a Canadian Clinic\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eRelated supplies for the same workflow\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003e24-hour self-contained biological indicators, 25 per pack\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-rapid-reader-4-well-fluorescence-biological-indicator-reader\"\u003e4-well fluorescence biological indicator reader\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-24-hour-biological-indicator-incubator-precision-dry-block-15-wells\"\u003eCliniEco 24-hour dry block incubator, 15-well\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/p25_01_main_1500_E2.jpg?v=1793459608\" alt=\"24-hour self-contained biological indicators\" loading=\"lazy\" width=\"480\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/sterilizer-testing-frequency-us-vs-canada-biological-indicator-ordering\"\u003eHow Often Must US vs Canadian Clinics Run Sterilizer Testing? Which Biological Indicator Pack to Order\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/how-often-us-vs-canadian-clinics-sterilizer-testing-incubator-guide\"\u003eHow Often Must US vs Canadian Clinics Run Sterilizer Testing? 24-Hour Biological Indicator Incubator Ordering \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/how-do-i-know-if-my-autoclave-is-working-properly\"\u003eHow do I know if my autoclave is working properly?\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow does a 24-hour incubation run actually work, hour by hour?\u003c\/h2\u003e\n\u003cp\u003eThe run is shorter to describe than it is to get wrong. After the sterilization cycle, each indicator is activated according to the manufacturer's instructions for use, labelled so it can be matched to the sterilizer and the load, stood in the block, and left at incubation temperature for the full readout period. With a 24-hour self-contained indicator that means the block is occupied for a working day, the lid stays on, and the result is read the following day against the unexposed control that was incubated alongside it.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eStage\u003c\/th\u003e\n\u003cth\u003eWhat happens at the unit\u003c\/th\u003e\n\u003cth\u003eWhat is written down\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad\u003c\/td\u003e\n\u003ctd\u003eVials stand in the 20 wells (5 rows × 4 columns, Ø 11 mm), which take an 8 mm vial body with a 10 mm cap\u003c\/td\u003e\n\u003ctd\u003eDate, sterilizer, cycle type and lot code against each position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet the temperature\u003c\/td\u003e\n\u003ctd\u003eThe block is set into the 56–60 °C band for steam indicators; the display reads to 0.1 °C\u003c\/td\u003e\n\u003ctd\u003eSet point, and whether a reference probe was used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRun\u003c\/td\u003e\n\u003ctd\u003eThe timer counts through the readout period — 0 min to 99 h 59 min on this unit — with the transparent lid closed by hand\u003c\/td\u003e\n\u003ctd\u003eStart time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRead\u003c\/td\u003e\n\u003ctd\u003ePurple means no growth and the load releases; yellow means spores survived\u003c\/td\u003e\n\u003ctd\u003eResult, read time, and the control's result\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn a fail\u003c\/td\u003e\n\u003ctd\u003eThe load goes back for re-sterilization and the sterilizer is re-tested before anything in it is released\u003c\/td\u003e\n\u003ctd\u003eThe fail itself, the corrective step and the re-test result\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTwo things about that sequence are worth stating plainly, because they are where an inspection usually lands. The lid is closed by hand and there is nothing that closes it for you, so a run started in a hurry with the lid left off is a run at the wrong temperature. And the block only holds, it does not read: the colour change on the vial is the result, and this unit is not a reader.\u003c\/p\u003e\n\n\u003ch2\u003eHow many vials fit in one run, and when does a result slide to the next day?\u003c\/h2\u003e\n\u003cp\u003eTwenty wells hold twenty vials, and a monitoring day needs two vials per sterilizer — the test and its matching control. That is ten sterilizer-days per batch, which is exactly one sterilizer over ten test days, or two sterilizers over five. A 25-pack therefore takes two batches, because twenty vials fit and five are left over; that leftover is why the 50-pack is the size that ships with this unit rather than the 25.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSterilizers tested per day\u003c\/th\u003e\n\u003cth\u003eVials needed per day\u003c\/th\u003e\n\u003cth\u003eDays one 20-well batch covers\u003c\/th\u003e\n\u003cth\u003eWhat that means for ordering\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e10 test days\u003c\/td\u003e\n\u003ctd\u003eA 25-pack runs as two batches; a 50-pack as five\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e5 test days\u003c\/td\u003e\n\u003ctd\u003eOne week of daily monitoring per batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3 test days\u003c\/td\u003e\n\u003ctd\u003ePlan the week around the block rather than the block around the week\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4 and up\u003c\/td\u003e\n\u003ctd\u003e8 and up\u003c\/td\u003e\n\u003ctd\u003e2 test days or fewer\u003c\/td\u003e\n\u003ctd\u003eTime to ask whether one block is the right equipment for the room\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWhy this matters more than it sounds: a 24-hour readout occupies the well for the whole period, so a batch that does not fit does not run late — it splits across two days, and the second day's results are a day behind. A room that tests two sterilizers daily should be loading the whole week's worth of work into one batch, not discovering on Thursday that the block has been full since Tuesday.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does the certification cover, and what goes in the file?\u003c\/h2\u003e\n\u003cp\u003eThe electrical documentation is the part of a benchtop incubator that auditors ask for and that most listings do not print. This unit carries cTUVus certification from TÜV Rheinland under certificate CU 72205506 0001, tested to UL 61010-1 and CAN\/CSA-C22.2 No. 61010-1-12, with the EMC registrations below held on file.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003cth\u003eWhat it covers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical safety certification\u003c\/td\u003e\n\u003ctd\u003ecTUVus, TÜV Rheinland certificate CU 72205506 0001\u003c\/td\u003e\n\u003ctd\u003eUL 61010-1 and CAN\/CSA-C22.2 No. 61010-1-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC, United States\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Subpart B, registration AK 50495998 0001\u003c\/td\u003e\n\u003ctd\u003eEmissions compliance for the US market\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC, Canada\u003c\/td\u003e\n\u003ctd\u003eICES-001:2006, registration AK 50496013 0001\u003c\/td\u003e\n\u003ctd\u003eEmissions compliance for the Canadian market\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e115 V AC, 50\/60 Hz, North American plug\u003c\/td\u003e\n\u003ctd\u003eThe building supply the unit is rated for\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eDLAB Scientific Co., Ltd., Beijing\u003c\/td\u003e\n\u003ctd\u003eWho built the unit and issues the manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImporter\u003c\/td\u003e\n\u003ctd\u003eCliniEco Medical, Health Canada MDEL #35334\u003c\/td\u003e\n\u003ctd\u003eWho is accountable for it in Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAsk for the certificate and the two registration numbers as documents, not as claims on a listing page — that is the whole point of printing the numbers. The instruction manual ships in English with the unit and in French on request, and the manufacturer's warranty terms are available on request.\u003c\/p\u003e\n\n\u003ch2\u003eHow is the incubation temperature set, and how is it checked?\u003c\/h2\u003e\n\u003cp\u003eThe block runs from room temperature +5 °C up to 105 °C, and steam biological indicators are incubated in the 56–60 °C band, so the set point is a band rather than a single number. The display reads to 0.1 °C and the timer runs to 99 h 59 min, which covers a 24-hour readout with room to spare. The unit also supports a PT1000 external probe, which is the useful part: it lets a practice read from a reference point in the block rather than trusting the set point alone.\u003c\/p\u003e\n\u003cp\u003eWhat the unit does not do is record. There is no logging and no export — the numbers on the LED display are copied onto your own record sheet, which is why the printable logs at the compliance log centre are worth printing before the incubator arrives rather than after. A practice that wants a temperature trace has to keep one; this unit holds the temperature, it does not document it.\u003c\/p\u003e\n\n\u003ch2\u003eWhat this incubator is not\u003c\/h2\u003e\n\u003cp\u003eFour exclusions, each of which sends a buyer somewhere else, and it is quicker to say them here than to discover them after delivery. It is not a reader: 1-hour, 3-hour and 20-minute fluorescence indicators need their own reader and are not incubated here. It is not a data logger. It is not a water bath, so there is nothing to fill, change or spill, and nothing that grows in a tank between runs. And it is not a general-purpose dry bath — the block is drilled for standard self-contained vials to ISO 11138-3, not for tubes of arbitrary size.\u003c\/p\u003e\n\u003cp\u003eThe direct consequence of the first exclusion is the one to plan for: a practice that wants same-shift release needs a rapid-readout system, and a practice that tests daily and releases the next morning is the one this unit is built for.\u003c\/p\u003e\n\n\u003ch2\u003eWho this incubator suits, and who it does not\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSetting\u003c\/th\u003e\n\u003cth\u003eFits?\u003c\/th\u003e\n\u003cth\u003eReason\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolo or small practice, one sterilizer, daily testing\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eTwo vials a day occupies a tenth of the block; the 50-pack ships with the unit for exactly this rhythm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePractice with two sterilizers tested daily\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eFour vials a day, twenty wells, a week of work per batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-site group standardising across rooms\u003c\/td\u003e\n\u003ctd\u003eYes, one per room\u003c\/td\u003e\n\u003ctd\u003eThe unit is a small benchtop box; a shared incubator between rooms means carrying activated vials down a corridor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinic using rapid-readout fluorescence indicators\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eThose need a reader; this block does not interpret them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinic wanting an automated temperature record\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo logging or export — the record is written by hand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWhere it does fit, the first-year cost is one capital line and one consumable line: the incubator once, the indicators every time the box runs out. Spread across a daily-monitoring year the unit is the smaller of the two numbers, which is worth knowing before a practice decides to keep spore-testing by hand and ordering the box that actually documents it later.\u003c\/p\u003e\n\n\u003ch2\u003eWhere should the incubator sit in the reprocessing room?\u003c\/h2\u003e\n\u003cp\u003eIt is a benchtop box of 3.2 kg with the block fitted, and it runs from a standard 115 V AC outlet with a North American plug, so the siting question is about workflow rather than services. Put it where the indicators are activated and where the record is written. A block that lives at the far end of the room from the log sheet is a block whose results get copied down from memory at four o'clock, which is the failure mode a paper record is supposed to prevent.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSiting question\u003c\/th\u003e\n\u003cth\u003eWhat the unit needs\u003c\/th\u003e\n\u003cth\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBench space\u003c\/td\u003e\n\u003ctd\u003eRoom for the footprint plus the hand-closed lid to open and close\u003c\/td\u003e\n\u003ctd\u003eThe lid is operated by hand at the start and end of every run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e115 V AC, 50\/60 Hz, North American plug\u003c\/td\u003e\n\u003ctd\u003eThe unit is supplied as the North American build\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhere the log is kept\u003c\/td\u003e\n\u003ctd\u003eBeside the block, not across the room\u003c\/td\u003e\n\u003ctd\u003eResult, time and lot code are copied off the vials and the display at the end of the run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhere vials are activated\u003c\/td\u003e\n\u003ctd\u003eThe same bench, or the bench next to it\u003c\/td\u003e\n\u003ctd\u003eActivated vials go straight into the block rather than travelling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraffic\u003c\/td\u003e\n\u003ctd\u003eOff the walkway between the sink and the autoclave\u003c\/td\u003e\n\u003ctd\u003eAn incubator is bumped once a month in a busy room, and a knocked block is a lost batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThere is nothing to plumb and nothing to drain, which is the practical advantage of a dry block over a water bath: a bench, a socket and a log sheet are the whole installation.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to check on arrival\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat good looks like\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel and nameplate\u003c\/td\u003e\n\u003ctd\u003eHB105-S1 with the transparent lid, matching the certificate number quoted on this page\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlock\u003c\/td\u003e\n\u003ctd\u003eOne block, 20 wells in 5 rows of 4, Ø 11 mm, seated squarely in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLid\u003c\/td\u003e\n\u003ctd\u003eCloses by hand, sits flush, and does not foul the vial caps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirst run\u003c\/td\u003e\n\u003ctd\u003eSet the block into the 56–60 °C band and confirm the display holds it before the first real batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocuments\u003c\/td\u003e\n\u003ctd\u003eManual in the carton, certificate and EMC registrations on request, importer details on the label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"DLAB","offers":[{"title":"Default Title","offer_id":49214013014238,"sku":"DLAB-HB105-S1","price":499.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/HB105-S1-HERO-promo50-20261110_e2b9bf73-4800-4710-977d-b4bb450cb83c_e0c85514-64d8-48e1-87c7-783f4b7d0fbb.jpg?v=1794342653"},{"product_id":"clinieco-ultrasonic-cleaner-4l-cs4-0-benchtop-dual-frequency","title":"CliniEco Dental Ultrasonic Cleaner — 4 L Benchtop, CS4.0 Dual-Frequency 32\/48 kHz","description":"\u003cp\u003e\u003cstrong\u003eQuick answer:\u003c\/strong\u003e A 4 L tank with both frequencies on one dial and a five-step timer — enough for the loose instruments from one chair, and not enough for a full cassette.\u003c\/p\u003e\n\u003c!-- ce-glance:CS4.0 --\u003e\n\u003cdiv class=\"ce-glance\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e4 L\u003c\/strong\u003e stainless steel tank · dual frequency 32 \/ 48 kHz · five-step timer · AC 100–120 V \/ 60 Hz · cETL certified by Intertek to CSA C22.2 No. 68 and UL 73.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003eLoose instruments from one chair. A standard dental instrument cassette does not fit a 4 L tank — that is the 6 L class. All sizes, 4 L to 20 L: \u003ca href=\"\/en-us\/collections\/ultrasonic-cleaners\"\u003eultrasonic cleaners and enzyme solution for dental practices in Canada\u003c\/a\u003e.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHow to order\u003c\/th\u003e\n\u003ctd\u003eShips from Toronto, Ontario. Order a single unit online, or by purchase order through \u003ca href=\"\/en-us\/pages\/wholesale\"\u003ewholesale and institutional ordering\u003c\/a\u003e. Built to order — allow 3–4 weeks, and the dispatch date is confirmed before it ships.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\n\u003cp\u003eMost benchtop ultrasonic cleaners sold online are built for jewellery and eyewear. They are small, they are cheap, and the timer is a single knob you cannot repeat. The CS4.0 is the same platform as our 6 L unit in a smaller footprint: a 4,000 ml stainless tank, 32 kHz and 48 kHz on the same generator, controlled heating with a temperature read-out in both °C and °F, a drain valve, and a timer with five fixed steps so the same load gets the same cycle next week.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eScope of use.\u003c\/strong\u003e This is a cleaning device. It removes soil — cement residue, polishing paste, dried blood in hinges and threads — as a step in instrument reprocessing. It makes no microbicidal claim, and it does not replace any later step in the workflow set out in the instrument manufacturer’s instructions for use. The \u003ca href=\"https:\/\/www.canada.ca\/en\/health-canada\/services\/drugs-health-products\/medical-devices\/application-information\/guidance-documents\/guidance-document-information-manufacturers-sterilization-reusable-medical-devices.html\"\u003eHealth Canada guidance on reprocessing information\u003c\/a\u003e is why the instrument manufacturer’s instructions — not the cleaner’s specification sheet — decide what happens to a given instrument after it comes out of the tank.\u003c\/p\u003e\n\n\u003ch2\u003eWhat are the CS4.0 specifications?\u003c\/h2\u003e\n\n\u003cp\u003eThe numbers below are the ones that decide whether the unit fits a room: how much liquid you have to mix, how long the cycle runs, and what the electrical certificate actually names.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eTank capacity:\u003c\/strong\u003e 4 L (4,000 ml) stainless steel, with drainage valve\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e Dual — 32 kHz for heavier soil, 48 kHz for fine crevices and hinged joints\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTimer:\u003c\/strong\u003e Five fixed steps: 5 \/ 7.5 \/ 10 \/ 12.5 \/ 15 minutes\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eProgram memory:\u003c\/strong\u003e Remembers the last timer and temperature setting between cycles\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHeating:\u003c\/strong\u003e Controlled heating with a temperature display in °C and °F\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHousing:\u003c\/strong\u003e Moisture-resistant PCB in a hybrid aluminium and plastic housing\u003c\/p\u003e\u003ctable\u003e\n\u003ccaption\u003eCS4.0 — 4 L benchtop ultrasonic cleaner, specifications as supplied\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eField\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTank capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 L (4,000 ml) stainless steel, with drainage valve\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTank dimensions\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e24.8 × 17.4 × 10.3 cm (length × width × depth), SUS304 stainless steel tank\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual — 32 kHz for heavier soil, 48 kHz for fine crevices and hinged joints\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTimer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFive fixed steps: 5 \/ 7.5 \/ 10 \/ 12.5 \/ 15 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgram memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemembers the last timer and temperature setting between cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControlled heating with a temperature display in °C and °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoisture-resistant PCB in a hybrid aluminium and plastic housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC 100–120 V, 50\/60 Hz, North American plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ecETL — Intertek report 220112139GZU-001, to UL 73 and CSA C22.2 No. 68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnit, one-year manufacturer warranty; stainless basket available as an accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eList price\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAD $449.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eDoes this unit log cleaning cycles?\u003c\/h2\u003e\n\u003cp\u003eNo. The CS4.0 has no internal data logger and cannot export cycle data to a USB drive or a CSV file. If your reprocessing protocol requires machine-generated cycle records, choose a unit built for that purpose — this model is not one.\u003c\/p\u003e\n\u003cp\u003eWhat the CS4.0 gives you instead is everything needed to keep a defensible manual record: a front-panel timer that counts the cycle, a temperature set-point you can read and write down, and a drain valve so the solution-change date is unambiguous. Under CSA Z314:23 the documentation obligation sits inside your reprocessing quality system rather than inside the appliance, so a signed paper log is not a lesser record — it is the record the standard asks for.\u003c\/p\u003e\n\u003cp\u003eFive fields per cycle is enough: date, operator, temperature set-point, cycle length, and the date the solution was last changed. One line, end of shift.\u003c\/p\u003e\n\u003ch2\u003eWhich tank size in the range fits your room?\u003c\/h2\u003e\n\n\u003cp\u003eThe size break in this range is not a matter of taste. A standard dental instrument cassette does not fit a 4 L tank, and it does fit a 6 L tank. If your day is one chair’s hand instruments, the 4 L is the whole requirement; if a cassette goes in the tank, you are shopping one row down.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eModel range as listed — tank, frequency and the load each size is built for\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eTank\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eBuilt for\u003c\/th\u003e\n\u003cth\u003eList price (CAD)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCS4.0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 L\u003c\/td\u003e\n\u003ctd\u003e32 \/ 48 kHz\u003c\/td\u003e\n\u003ctd\u003eSingle chair, loose instruments\u003c\/td\u003e\n\u003ctd\u003e$449.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-cd4862-6l-dental\"\u003eCD-4862\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eFull cassette, five temperature presets\u003c\/td\u003e\n\u003ctd\u003e$649.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003eCS6.2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L\u003c\/td\u003e\n\u003ctd\u003e32 \/ 48 kHz\u003c\/td\u003e\n\u003ctd\u003eFull cassette, dual frequency\u003c\/td\u003e\n\u003ctd\u003e$699.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-cd4875-7-5l-dental\"\u003eCD-4875\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eLarger trays, five temperature presets\u003c\/td\u003e\n\u003ctd\u003e$849.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-8l-cs8-0-benchtop\"\u003eCS8.0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e8 L\u003c\/td\u003e\n\u003ctd\u003e49 kHz\u003c\/td\u003e\n\u003ctd\u003eTwo chairs into one cycle\u003c\/td\u003e\n\u003ctd\u003e$999.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-20l-cs20-bench\"\u003eCS20\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eSeveral chairs or batch work\u003c\/td\u003e\n\u003ctd\u003e$1,199.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eTwo practical checks before you order. First, measure the longest instrument you routinely clean — a 4 L tank sets the limit sooner than most people expect. Second, count how many times a day you would run the tank: a single load in the morning and a single load at close is the pattern this size is built for, and three or four loads is the pattern that pushes a practice into the 6 L class.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/599bf33f4da20fb38d1771bb70a76d19.png?v=1792815581\" alt=\"Six litre benchtop ultrasonic cleaner, straight-on view of the unit with the lid closed\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch2\u003eHow do you run a repeatable cleaning cycle on the CS4.0?\u003c\/h2\u003e\n\n\u003cp\u003eThe value of this unit in an inspection is that the cycle can be described in one line and repeated tomorrow by someone else. That means fixed numbers, not judgement calls.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eCycle set-up step by step\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStep\u003c\/th\u003e\n\u003cth\u003eSetting\u003c\/th\u003e\n\u003cth\u003eWhy it matters\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1. Fill\u003c\/td\u003e\n\u003ctd\u003eWorking level with solution at the label dilution (1:400 to 1:600 for our enzyme concentrate)\u003c\/td\u003e\n\u003ctd\u003eUnder-filling loads the transducer unevenly; over-filling spills into the housing seam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2. Heat\u003c\/td\u003e\n\u003ctd\u003eSet the temperature on the front panel and wait for the display to reach it\u003c\/td\u003e\n\u003ctd\u003eThe same set-point every day is what makes the log entry defensible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3. Load\u003c\/td\u003e\n\u003ctd\u003eInstruments in the basket or a tray, never flat on the tank floor\u003c\/td\u003e\n\u003ctd\u003eMetal on metal blocks cavitation underneath the instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4. Run\u003c\/td\u003e\n\u003ctd\u003eChoose 5, 7.5, 10, 12.5 or 15 minutes — the unit remembers the last setting\u003c\/td\u003e\n\u003ctd\u003eA fixed step is repeatable; a hand-held knob is not\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5. Drain and dry\u003c\/td\u003e\n\u003ctd\u003eEmpty through the drain valve, dry the chamber, record the cycle\u003c\/td\u003e\n\u003ctd\u003eResidue left overnight is the usual cause of a cloudy tank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eTwo habits make the difference. Keep the basket in — instruments resting on the tank floor leave shadows in the cavitation field and wear the stainless. And change solution on a schedule rather than when it looks dirty: the log is the evidence, and a tank that is topped up instead of changed cannot be reconstructed afterwards.\u003c\/p\u003e\n\n\u003cp\u003eWhat an infection-control inspection asks for is the record, not the machine. Ontario’s provincial reprocessing guidance asks for \u003cem\u003edocumentation and maintenance of records for each component of the cleaning, disinfection and\/or sterilization process\u003c\/em\u003e, based on the manufacturer’s recommendations, and repeats that records \u003cem\u003emust be retained according to the facility’s policy\u003c\/em\u003e (\u003ca href=\"https:\/\/www.publichealthontario.ca\/-\/media\/Documents\/B\/2013\/bp-cleaning-disinfection-sterilization-hcs.pdf?rev=074097c0ef2343379b7bb17d97b75526\u0026amp;sc_lang=en\"\u003ePublic Health Ontario, “Best Practices for Cleaning, Disinfection and Sterilization of Medical Equipment\/Devices In All Health Care Settings”, 3rd edition, checked 2026-11-07\u003c\/a\u003e). A unit with a drain valve, a visible timer and a stable temperature set-point is what makes that record short enough to write at the end of a shift.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does the cETL mark cover, and what does it not?\u003c\/h2\u003e\n\n\u003cp\u003eThe CS4.0 carries a cETL mark from Intertek under report 220112139GZU-001. The mark on the unit is an ETL mark issued by Intertek, tested against \u003ca href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL73\"\u003eUL 73\u003c\/a\u003e and \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/C22.2%20NO.%2068-18\/\"\u003eCSA C22.2 No. 68\u003c\/a\u003e. It is an electrical safety certificate. It is not a UL listing and it is not CSA certification, and it says nothing about how well the tank cleans. Canadian reprocessing practice sits on a separate standard, \u003ca href=\"https:\/\/store.csastandards.org\/store\/product\/2430344\/\"\u003eCSA Z314:23\u003c\/a\u003e, whose scope puts documentation inside the reprocessing quality system rather than inside the appliance.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eWhat the electrical certificate covers, and what it does not\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCovers\u003c\/th\u003e\n\u003cth\u003eDoes not cover\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical safety of the appliance, assessed to UL 73 and CSA C22.2 No. 68\u003c\/td\u003e\n\u003ctd\u003eCleaning performance on your instruments, on your water hardness, or at your solution concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe specific unit family named on Intertek report 220112139GZU-001\u003c\/td\u003e\n\u003ctd\u003eThe condition of an individual unit after a drop, a repair, or a modification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance of the supply, plug and cord assembly for the North American market\u003c\/td\u003e\n\u003ctd\u003eAny clinical outcome, or any claim that the unit removes or inactivates micro-organisms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe identity of the certificate holder and the factory it was issued to\u003c\/td\u003e\n\u003ctd\u003eYour own reprocessing records, which are yours to keep and produce\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\n\u003ch2\u003eWhat is in the box, and what should be ordered with it?\u003c\/h2\u003e\n\n\u003cp\u003eOne cleaner, 4 L, 110 V with a North American plug, plus the manufacturer warranty. The stainless basket is an accessory rather than a line item, so say so on the order if you want it in the same box. Nothing else is required to run a cycle except solution and water — no plumbing connection, no drain pump.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003eMulti-enzyme ultrasonic cleaning solution\u003c\/a\u003e is what goes in the tank, sold as a 1 L bottle or a 5 L pail and diluted 1:400 to 1:600. The \u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003e6 L CS6.2\u003c\/a\u003e is the unit to look at if your load grows into full cassettes. Read \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/choosing-ultrasonic-cleaner-tank-size-canadian-dental-clinic\"\u003ehow to choose a tank size\u003c\/a\u003e and \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/what-should-a-canadian-clinic-record-for-ultrasonic-cleaning-log-fields-and-retention\"\u003ewhat to record on the cleaning log\u003c\/a\u003e before you commit to a size.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does one tank fill cost in cleaning solution?\u003c\/h2\u003e\n\u003cp\u003eThe CS4.0 is the small end of the range, so the chemistry line is small too: a 4 L fill takes a few millilitres of concentrate, and a single bottle lasts a single-chair practice most of a year. The table converts the label dilution into millilitres per fill and into fills per pack, so the only number you have to look up on the day is the pack price.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCS4.0 — concentrate per full tank and pack yield at the two label dilutions\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eDilution on the label\u003c\/th\u003e\n\u003cth\u003eConcentrate per full tank (4 L, filled to nominal capacity)\u003c\/th\u003e\n\u003cth\u003eFills from a 1 L bottle\u003c\/th\u003e\n\u003cth\u003eFills from a 5 L pail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1:400 — heavier soil\u003c\/td\u003e\n\u003ctd\u003e≈ 10 mL\u003c\/td\u003e\n\u003ctd\u003e100 fills\u003c\/td\u003e\n\u003ctd\u003e500 fills\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1:600 — light soil\u003c\/td\u003e\n\u003ctd\u003e≈ 6.7 mL\u003c\/td\u003e\n\u003ctd\u003e150 fills\u003c\/td\u003e\n\u003ctd\u003e750 fills\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCost per fill = the current pack price divided by the fills in that pack. Both halves of that sum move — the pack price with the market, the fills with how full you run the tank — which is why the page gives the arithmetic instead of a per-cycle figure. If your protocol changes the bath once per working day, five days a week, 100 fills is roughly 20 working weeks from one bottle.\u003c\/p\u003e\n\n\u003ch2\u003eWhich cleaning solution goes in this tank, and when should it be changed?\u003c\/h2\u003e\n\u003cp\u003eThe bath is filled with the \u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003emulti-enzyme ultrasonic cleaning concentrate\u003c\/a\u003e, supplied as a 1 L bottle or a 5 L pail. It is formulated low-foam, which is the property that matters in an ultrasonic tank: a head of foam absorbs cavitation before it reaches the instrument surface. The label gives the working window — 1:400 to 1:600 dilution, 20–50 °C, a 2 to 10 minute cycle — and 24 months shelf life sealed, 90 days once opened.\u003c\/p\u003e\n\u003cp\u003eThe change interval is set by that label and by your facility protocol, not by the cleaner; what the cleaner contributes is a drain valve, so the change is a dated event rather than an estimate. Record it the same way the rest of the cleaning step is recorded: Ontario reprocessing guidance asks for \u003cem\u003edocumentation and maintenance of records for each component of the cleaning, disinfection and\/or sterilization process\u003c\/em\u003e (\u003ca href=\"https:\/\/www.publichealthontario.ca\/-\/media\/Documents\/B\/2013\/bp-cleaning-disinfection-sterilization-hcs.pdf?rev=074097c0ef2343379b7bb17d97b75526\u0026amp;sc_lang=en\"\u003ePublic Health Ontario provincial reprocessing guidance, 3rd edition, checked 2026-11-07\u003c\/a\u003e). Five fields are enough: date, dilution used, fill level, bath temperature, initials.\u003c\/p\u003e\n\n\u003ch2\u003eWhat is the lead time, and what maintenance does the unit need?\u003c\/h2\u003e\n\u003cp\u003eThis unit is built to order — allow 3–4 weeks, and we confirm the dispatch date before it ships. The manufacturer warranty runs one year and is supported in Canada. CliniEco Medical holds Health Canada establishment licence (MDEL) #35334 — importer and distributor — which is separate from the warranty terms. What the unit asks of you in return is short, and mostly about the bath rather than the electronics.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCS4.0 — routine maintenance and why each item is on the list\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTask\u003c\/th\u003e\n\u003cth\u003eInterval\u003c\/th\u003e\n\u003cth\u003eWhy it matters\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain and refill\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAt the interval the solution label and your protocol set\u003c\/td\u003e\n\u003ctd\u003eSoil load accumulates in the bath whatever the instruments look like when they come out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRun a fresh fill before the first load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery refill\u003c\/td\u003e\n\u003ctd\u003eDissolved air in new solution damps cavitation, and the bath should be at working temperature before an instrument goes in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRinse tank and basket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery change\u003c\/td\u003e\n\u003ctd\u003eResidue left on stainless carries soil into the next fill and films the tank over time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWipe lid and check cord, plug and drain valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003ctd\u003eThe three parts a drop or a wipe-down damages first\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeep the level above the working minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery cycle\u003c\/td\u003e\n\u003ctd\u003eRunning dry is the one failure mode that ends a tank’s service life early\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTwo habits keep a small bath predictable: never run it below the working level, and mix to the label ratio rather than adding extra concentrate for a heavily soiled load — over-strength solution leaves a residue that the next rinse then has to remove.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRelated reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/ultrasonic-cleaner-canadian-clinic-tank-frequency-proof-of-clean\"\u003eUltrasonic Cleaner for a Canadian Clinic: Tank, Frequency and Proof of Clean\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/how-often-change-ultrasonic-cleaning-solution-dental\"\u003eHow Often Should a Dental Office Change Ultrasonic Cleaning Solution?\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/ultrasonic-cleaner-water-change-log-printable\"\u003eUltrasonic Cleaner Log Sheet: Daily Water Change and Solution Record\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCliniEco Medical is a licensed medical device establishment (MDEL #35334). We are the Canadian importer of record for this unit: duties and brokerage are handled on our side, and you receive it from our Toronto warehouse with a one-year manufacturer warranty supported in Canada. Questions on which size fits your room go to our \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003esterilization desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt to order.\u003c\/strong\u003e Allow 3–4 weeks — we confirm the dispatch date before the unit ships.\u003c\/p\u003e","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":49376913359070,"sku":"CLI-ULTRA-CLEAN-40","price":449.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CS4.0-HERO-logo-20261110_dee47aa8-3f3d-466e-8757-53fb9d5b6fab_42c73aba-755f-4e7b-80bd-d0cbb7bf80cf.jpg?v=1794342677"},{"product_id":"clinieco-ultrasonic-cleaner-8l-cs8-0-benchtop","title":"CliniEco Dental Ultrasonic Cleaner — 8 L Benchtop, CS8.0 49 kHz with Heater","description":"\u003cp\u003e\u003cstrong\u003eQuick answer:\u003c\/strong\u003e 8 L nominal, 7,000 ml of usable working volume, single frequency at 49 kHz — the size that takes two chairs' instruments in one cycle and the frequency that is easiest on hinged and plated instruments.\u003c\/p\u003e\n\n\u003cp\u003eTwo chairs into one cycle is the argument for an 8 L tank. The morning load runs once instead of twice, and the person doing it is not standing over a tank at 9:15 with patients already seated. The CS8.0 is also the only single-frequency unit in this range: 49 kHz, chosen for small-bubble cavitation into threads and hinges rather than for stripping heavy cement. If most of your soil is heavy, the dual-frequency 6 L is the better fit.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eScope of use.\u003c\/strong\u003e This is a cleaning device. It removes soil — cement residue, polishing paste, dried blood in hinges and threads — as a step in instrument reprocessing. It makes no microbicidal claim, and it does not replace any later step in the workflow set out in the instrument manufacturer’s instructions for use. The \u003ca href=\"https:\/\/www.canada.ca\/en\/health-canada\/services\/drugs-health-products\/medical-devices\/application-information\/guidance-documents\/guidance-document-information-manufacturers-sterilization-reusable-medical-devices.html\"\u003eHealth Canada guidance on reprocessing information\u003c\/a\u003e is why the instrument manufacturer’s instructions — not the cleaner’s specification sheet — decide what happens to a given instrument after it comes out of the tank.\u003c\/p\u003e\n\n\u003ch2\u003eWhat are the CS8.0 specifications?\u003c\/h2\u003e\n\n\u003cp\u003eThe distinction that matters most here is nominal against working volume. An 8 L tank is not 8,000 ml of usable liquid, and the working figure is what decides how many instruments go in.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eTank capacity:\u003c\/strong\u003e 8 L nominal (8,000 ml) — 7,000 ml working volume, 3,600 ml minimum fill\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e 49 kHz, single frequency\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e 450 W\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupply:\u003c\/strong\u003e AC 100–120 V, 60 Hz, North American plug\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDrain:\u003c\/strong\u003e Drain valve fitted for emptying between sessions\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBasket:\u003c\/strong\u003e Stainless basket available as an accessory; internal basket dimensions 31.15 × 21.15 × 5.5 cm\u003c\/p\u003e\u003ctable\u003e\n\u003ccaption\u003eCS8.0 — 8 L benchtop ultrasonic cleaner, specifications as supplied\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eField\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTank capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 L nominal (8,000 ml) — 7,000 ml working volume, 3,600 ml minimum fill\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTank dimensions\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e33.1 × 23.8 × 11.6 cm (length × width × depth), SUS304 stainless steel tank\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49 kHz, single frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC 100–120 V, 60 Hz, North American plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDrain valve fitted for emptying between sessions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless basket available as an accessory; internal basket dimensions 31.15 × 21.15 × 5.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ecETL — Intertek report 220112139GZU-001, to UL 73 and CSA C22.2 No. 68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnit, one-year manufacturer warranty, Canadian warranty support from our Toronto warehouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eList price\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAD $999.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eDoes this unit log cleaning cycles?\u003c\/h2\u003e\n\u003cp\u003eNo. The CS8.0 has no internal data logger and cannot export cycle data to a USB drive or a CSV file. If your reprocessing protocol requires machine-generated cycle records, choose a unit built for that purpose — this model is not one.\u003c\/p\u003e\n\u003cp\u003eWhat the CS8.0 gives you instead is everything needed to keep a defensible manual record: a front-panel timer that counts the cycle, a temperature set-point you can read and write down, and a drain valve so the solution-change date is unambiguous. Under CSA Z314:23 the documentation obligation sits inside your reprocessing quality system rather than inside the appliance, so a signed paper log is not a lesser record — it is the record the standard asks for.\u003c\/p\u003e\n\u003cp\u003eFive fields per cycle is enough: date, operator, temperature set-point, cycle length, and the date the solution was last changed. One line, end of shift.\u003c\/p\u003e\n\u003ch2\u003eWhich tank size in the range fits your room?\u003c\/h2\u003e\n\n\u003cp\u003eAt this size the decision is usually between the 8 L and the 6 L: same family, similar footprint, different frequency and different usable volume. The 6 L is the cassette-size unit; the 8 L is the unit for two chairs' loads or for anyone who wants 49 kHz.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eModel range as listed — tank, frequency and the load each size is built for\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eTank\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eBuilt for\u003c\/th\u003e\n\u003cth\u003eList price (CAD)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-4l-cs4-0-benchtop-dual-frequency\"\u003eCS4.0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 L\u003c\/td\u003e\n\u003ctd\u003e32 \/ 48 kHz\u003c\/td\u003e\n\u003ctd\u003eSingle chair, loose instruments\u003c\/td\u003e\n\u003ctd\u003e$449.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-cd4862-6l-dental\"\u003eCD-4862\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eFull cassette, five temperature presets\u003c\/td\u003e\n\u003ctd\u003e$649.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003eCS6.2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L\u003c\/td\u003e\n\u003ctd\u003e32 \/ 48 kHz\u003c\/td\u003e\n\u003ctd\u003eFull cassette, dual frequency\u003c\/td\u003e\n\u003ctd\u003e$699.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-cd4875-7-5l-dental\"\u003eCD-4875\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eLarger trays, five temperature presets\u003c\/td\u003e\n\u003ctd\u003e$849.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCS8.0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 L\u003c\/td\u003e\n\u003ctd\u003e49 kHz\u003c\/td\u003e\n\u003ctd\u003eTwo chairs into one cycle\u003c\/td\u003e\n\u003ctd\u003e$999.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-20l-cs20-bench\"\u003eCS20\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eSeveral chairs or batch work\u003c\/td\u003e\n\u003ctd\u003e$1,199.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eIf you run more than eight or ten loads a day, neither of these is the answer — that is the point at which a 20 L tank with eight transducers starts to pay for itself. Below that threshold the 8 L removes the second run without turning the bench into a wet room.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/599bf33f4da20fb38d1771bb70a76d19.png?v=1792815581\" alt=\"Six litre benchtop ultrasonic cleaner, straight-on view of the unit with the lid closed\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch2\u003eHow do you run a repeatable cleaning cycle on the CS8.0?\u003c\/h2\u003e\n\n\u003cp\u003eThe 49 kHz setting is quieter and less aggressive than a 32 kHz tank, which changes how you load it rather than how long you run it. Fewer, better-spaced instruments clean better than a packed basket.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eCycle set-up step by step\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStep\u003c\/th\u003e\n\u003cth\u003eSetting\u003c\/th\u003e\n\u003cth\u003eWhy it matters\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1. Fill\u003c\/td\u003e\n\u003ctd\u003e7,000 ml working volume — not the 8,000 ml the tank is named for\u003c\/td\u003e\n\u003ctd\u003eOver-filling to the brim leaves no room for displacement and spills at the seam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2. Heat\u003c\/td\u003e\n\u003ctd\u003eBring the solution to the temperature printed on the solution label\u003c\/td\u003e\n\u003ctd\u003eEnzyme activity has a temperature window; a cold tank under-performs on the same load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3. Load\u003c\/td\u003e\n\u003ctd\u003eBasket only, instruments not touching each other\u003c\/td\u003e\n\u003ctd\u003eCavitation is blocked where two surfaces meet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4. Run\u003c\/td\u003e\n\u003ctd\u003eOne full cycle per load, timed from the panel\u003c\/td\u003e\n\u003ctd\u003eA repeatable interval is what makes the log meaningful\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5. Drain, dry, record\u003c\/td\u003e\n\u003ctd\u003eEmpty through the valve, dry the chamber, write the entry\u003c\/td\u003e\n\u003ctd\u003eThe record is what an inspection reads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eBecause 49 kHz works with smaller bubbles, it reaches into threads and box joints that larger bubbles miss, but it also gives up some stripping power on set cement. If you routinely clean crown-and-bridge work with cement residue, pre-wipe the instrument before it goes in the tank rather than extending the cycle.\u003c\/p\u003e\n\n\u003cp\u003eWhat an infection-control inspection asks for is the record, not the machine. Ontario’s provincial reprocessing guidance asks for \u003cem\u003edocumentation and maintenance of records for each component of the cleaning, disinfection and\/or sterilization process\u003c\/em\u003e, based on the manufacturer’s recommendations, and repeats that records \u003cem\u003emust be retained according to the facility’s policy\u003c\/em\u003e (\u003ca href=\"https:\/\/www.publichealthontario.ca\/-\/media\/Documents\/B\/2013\/bp-cleaning-disinfection-sterilization-hcs.pdf?rev=074097c0ef2343379b7bb17d97b75526\u0026amp;sc_lang=en\"\u003ePublic Health Ontario, “Best Practices for Cleaning, Disinfection and Sterilization of Medical Equipment\/Devices In All Health Care Settings”, 3rd edition, checked 2026-11-07\u003c\/a\u003e). A unit with a drain valve, a visible timer and a stable temperature set-point is what makes that record short enough to write at the end of a shift.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does the cETL mark cover, and what does it not?\u003c\/h2\u003e\n\n\u003cp\u003eThe CS8.0 carries a cETL mark from Intertek under report 220112139GZU-001, the same report that covers the 4 L unit. The mark on the unit is an ETL mark issued by Intertek, tested against \u003ca href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL73\"\u003eUL 73\u003c\/a\u003e and \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/C22.2%20NO.%2068-18\/\"\u003eCSA C22.2 No. 68\u003c\/a\u003e. It is an electrical safety certificate. It is not a UL listing and it is not CSA certification, and it says nothing about how well the tank cleans. Canadian reprocessing practice sits on a separate standard, \u003ca href=\"https:\/\/store.csastandards.org\/store\/product\/2430344\/\"\u003eCSA Z314:23\u003c\/a\u003e, whose scope puts documentation inside the reprocessing quality system rather than inside the appliance.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eWhat the electrical certificate covers, and what it does not\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCovers\u003c\/th\u003e\n\u003cth\u003eDoes not cover\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical safety of the appliance, assessed to UL 73 and CSA C22.2 No. 68\u003c\/td\u003e\n\u003ctd\u003eCleaning performance on your instruments, on your water hardness, or at your solution concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe specific unit family named on Intertek report 220112139GZU-001\u003c\/td\u003e\n\u003ctd\u003eThe condition of an individual unit after a drop, a repair, or a modification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance of the supply, plug and cord assembly for the North American market\u003c\/td\u003e\n\u003ctd\u003eAny clinical outcome, or any claim that the unit removes or inactivates micro-organisms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe identity of the certificate holder and the factory it was issued to\u003c\/td\u003e\n\u003ctd\u003eYour own reprocessing records, which are yours to keep and produce\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\n\u003ch2\u003eWhat is in the box, and what should be ordered with it?\u003c\/h2\u003e\n\n\u003cp\u003eOne cleaner, 8 L, 110 V with a North American plug and the manufacturer warranty. The stainless basket is an accessory, so ask for it explicitly if you want it shipped in the same box. No plumbing or drain pump is required.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003eMulti-enzyme ultrasonic cleaning solution\u003c\/a\u003e is what goes in the tank, sold as a 1 L bottle or a 5 L pail and diluted 1:400 to 1:600. The \u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003e6 L CS6.2\u003c\/a\u003e is the unit to look at if your load grows into full cassettes. Read \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/choosing-ultrasonic-cleaner-tank-size-canadian-dental-clinic\"\u003ehow to choose a tank size\u003c\/a\u003e and \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/what-should-a-canadian-clinic-record-for-ultrasonic-cleaning-log-fields-and-retention\"\u003ewhat to record on the cleaning log\u003c\/a\u003e before you commit to a size.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does one tank fill cost in cleaning solution?\u003c\/h2\u003e\n\u003cp\u003eAn 8 L bath is usually bought for two chairs feeding one cycle, and that doubles the chemistry per fill against the 4 L unit while halving the number of fills a bottle gives. The arithmetic below uses this page’s own nominal capacity, so the millilitres are the ones your staff will actually measure at the bench.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCS8.0 — concentrate per full tank and pack yield at the two label dilutions\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eDilution on the label\u003c\/th\u003e\n\u003cth\u003eConcentrate per full tank (8 L nominal capacity)\u003c\/th\u003e\n\u003cth\u003eFills from a 1 L bottle\u003c\/th\u003e\n\u003cth\u003eFills from a 5 L pail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1:400 — heavier soil\u003c\/td\u003e\n\u003ctd\u003e≈ 20 mL\u003c\/td\u003e\n\u003ctd\u003e50 fills\u003c\/td\u003e\n\u003ctd\u003e250 fills\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1:600 — light soil\u003c\/td\u003e\n\u003ctd\u003e≈ 13.3 mL\u003c\/td\u003e\n\u003ctd\u003e75 fills\u003c\/td\u003e\n\u003ctd\u003e375 fills\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCost per fill = the current pack price divided by the fills in that pack. Both halves of that sum move — the pack price with the market, the fills with how full you run the tank — which is why the page gives the arithmetic instead of a per-cycle figure. If your protocol changes the bath once per working day, five days a week, 50 fills is roughly 10 working weeks from one bottle.\u003c\/p\u003e\n\n\u003ch2\u003eWhich cleaning solution goes in this tank, and when should it be changed?\u003c\/h2\u003e\n\u003cp\u003eThe tank takes the \u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003emulti-enzyme ultrasonic cleaning concentrate\u003c\/a\u003e in 1 L bottles or 5 L pails, diluted 1:400 to 1:600. Low-foam matters more as the tank gets bigger: the larger the free surface, the more foam a foaming product would build, and foam is cavitation energy that never reaches the instruments. Working window on the label is 20–50 °C over 2 to 10 minutes; sealed shelf life is 24 months, 90 days after opening.\u003c\/p\u003e\n\u003cp\u003eHow often the bath is changed belongs to the solution label and your facility protocol. The drain valve on this unit is what makes that a short job: empty, rinse, refill, and write the date on the log in the same line as the temperature and the operator. That record is what an inspection reconstructs the step from — Ontario guidance asks for \u003cem\u003edocumentation and maintenance of records for each component of the cleaning, disinfection and\/or sterilization process\u003c\/em\u003e, retained \u003cem\u003eaccording to the facility’s policy\u003c\/em\u003e (\u003ca href=\"https:\/\/www.publichealthontario.ca\/-\/media\/Documents\/B\/2013\/bp-cleaning-disinfection-sterilization-hcs.pdf?rev=074097c0ef2343379b7bb17d97b75526\u0026amp;sc_lang=en\"\u003ePublic Health Ontario, 3rd edition, checked 2026-11-07\u003c\/a\u003e).\u003c\/p\u003e\n\n\u003ch2\u003eWhat is the lead time, and what maintenance does the unit need?\u003c\/h2\u003e\n\u003cp\u003eThis unit is built to order — allow 3–4 weeks, and we confirm the dispatch date before it ships. The manufacturer warranty runs one year and is supported in Canada. CliniEco Medical holds Health Canada establishment licence (MDEL) #35334 — importer and distributor — which is separate from the warranty terms. What the unit asks of you in return is short, and mostly about the bath rather than the electronics.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCS8.0 — routine maintenance and why each item is on the list\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTask\u003c\/th\u003e\n\u003cth\u003eInterval\u003c\/th\u003e\n\u003cth\u003eWhy it matters\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain and refill\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAt the interval the solution label and your protocol set\u003c\/td\u003e\n\u003ctd\u003eSoil load accumulates in the bath whatever the instruments look like when they come out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRun a fresh fill before the first load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery refill\u003c\/td\u003e\n\u003ctd\u003eDissolved air in new solution damps cavitation, and the bath should be at working temperature before an instrument goes in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRinse tank and basket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery change\u003c\/td\u003e\n\u003ctd\u003eResidue left on stainless carries soil into the next fill and films the tank over time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWipe lid and check cord, plug and drain valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003ctd\u003eThe three parts a drop or a wipe-down damages first\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeep the level above the working minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery cycle\u003c\/td\u003e\n\u003ctd\u003eRunning dry is the one failure mode that ends a tank’s service life early\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFill to the marked working volume rather than to the rim: the 8 L tank has a 7,000 ml working volume and a 3,600 ml minimum fill, and running near the minimum shortens the bath’s useful life in a busy room because the soil load builds faster.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRelated reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/ultrasonic-cleaner-canadian-clinic-tank-frequency-proof-of-clean\"\u003eUltrasonic Cleaner for a Canadian Clinic: Tank, Frequency and Proof of Clean\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/ultrasonic-cleaner-solution-canada-dilution-ratios-case-sizes-where-to-buy\"\u003eUltrasonic Cleaner Solution in Canada: Dilution Ratios and Case Sizes\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/instrument-cleaning-before-sterilization-why-it-matters\"\u003eInstrument Cleaning Before Sterilization: Why Pre-Cleaning Matters\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCliniEco Medical is a licensed medical device establishment (MDEL #35334). We are the Canadian importer of record for this unit: duties and brokerage are handled on our side, and you receive it from our Toronto warehouse with a one-year manufacturer warranty supported in Canada. Questions on which size fits your room go to our \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003esterilization desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt to order.\u003c\/strong\u003e Allow 3–4 weeks — we confirm the dispatch date before the unit ships.\u003c\/p\u003e","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":49376919716062,"sku":"CLI-ULTRA-CLEAN-80","price":999.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CS8.0-HERO-logo-20261110_21525ffc-870f-4967-a21d-f6513fd66b79_e693689f-41fa-4f94-a4ac-fdbfb1a3854c.jpg?v=1794342734"},{"product_id":"clinieco-ultrasonic-cleaner-20l-cs20-bench","title":"CliniEco Ultrasonic Cleaner — 20 L Bench Unit, CS20 with Heater and Drain Valve","description":"\u003cp\u003e\u003cstrong\u003eQuick answer:\u003c\/strong\u003e A 20 L chamber with eight transducers, 500 W of ultrasonic power and 500 W of heating — built for a clinic running several chairs, or a laboratory cleaning in batches.\u003c\/p\u003e\n\n\u003cp\u003eAt 20 L the tank stops being a bench accessory and becomes a station. The chamber is 42 × 26 × 20 cm, the unit is 54 × 37 × 40 cm and weighs 17 kg dry, and eight transducers are distributed under the floor so coverage holds across the full length rather than concentrating in the middle. It can sit on a counter or be installed recessed into one, which is usually how a multi-chair clinic handles a tank this size.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eScope of use.\u003c\/strong\u003e This is a cleaning device. It removes soil — cement residue, polishing paste, dried blood in hinges and threads — as a step in instrument reprocessing. It makes no microbicidal claim, and it does not replace any later step in the workflow set out in the instrument manufacturer’s instructions for use. The \u003ca href=\"https:\/\/www.canada.ca\/en\/health-canada\/services\/drugs-health-products\/medical-devices\/application-information\/guidance-documents\/guidance-document-information-manufacturers-sterilization-reusable-medical-devices.html\"\u003eHealth Canada guidance on reprocessing information\u003c\/a\u003e is why the instrument manufacturer’s instructions — not the cleaner’s specification sheet — decide what happens to a given instrument after it comes out of the tank.\u003c\/p\u003e\n\n\u003ch2\u003eWhat are the CS20 specifications?\u003c\/h2\u003e\n\n\u003cp\u003eThe two numbers that decide an installation are the loaded weight and the footprint: a 20 L working volume is roughly 20 kg of water plus a 17 kg unit.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eTank capacity:\u003c\/strong\u003e 20 L (5.3 US gal) — chamber 42 × 26 × 20 cm\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTransducers:\u003c\/strong\u003e 8, distributed across the tank floor\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e 500 W ultrasonic, 500 W heating, AC 100–120 V, North American plug\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eUnit dimensions:\u003c\/strong\u003e 54 × 37 × 40 cm; net weight 17 kg, gross 20 kg\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e Bench or recessed; noise-reduced cabinet, four-level circuit protection\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDrain:\u003c\/strong\u003e Electric drain valve\u003c\/p\u003e\u003ctable\u003e\n\u003ccaption\u003eCS20 — 20 L benchtop ultrasonic cleaner, specifications as supplied\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eField\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTank capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 L (5.3 US gal) — chamber 42 × 26 × 20 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTank dimensions\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e42 × 26 × 20 cm (length × width × depth)\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8, distributed across the tank floor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 W ultrasonic, 500 W heating, AC 100–120 V, North American plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54 × 37 × 40 cm; net weight 17 kg, gross 20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBench or recessed; noise-reduced cabinet, four-level circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectric drain valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ecETL — Intertek report 260210005GZU-001, to UL 73 and CSA C22.2 No. 68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnit, one-year manufacturer warranty; stainless basket available as an accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eList price\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAD $1,199.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eDoes this unit log cleaning cycles?\u003c\/h2\u003e\n\u003cp\u003eNo. The CS20 has no internal data logger and cannot export cycle data to a USB drive or a CSV file. If your reprocessing protocol requires machine-generated cycle records, choose a unit built for that purpose — this model is not one.\u003c\/p\u003e\n\u003cp\u003eWhat the CS20 gives you instead is everything needed to keep a defensible manual record: a front-panel timer that counts the cycle, a temperature set-point you can read and write down, and a drain valve so the solution-change date is unambiguous. Under CSA Z314:23 the documentation obligation sits inside your reprocessing quality system rather than inside the appliance, so a signed paper log is not a lesser record — it is the record the standard asks for.\u003c\/p\u003e\n\u003cp\u003eFive fields per cycle is enough: date, operator, temperature set-point, cycle length, and the date the solution was last changed. One line, end of shift.\u003c\/p\u003e\n\u003ch2\u003eWhich tank size in the range fits your room?\u003c\/h2\u003e\n\n\u003cp\u003eThis is the largest unit in the range and it is not the right unit for a two-chair practice. The sizes below it cover one chair, one cassette, or two chairs in one cycle; 20 L is for a room where the tank runs continuously or where instruments arrive in bulk.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eModel range as listed — tank, frequency and the load each size is built for\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eTank\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eBuilt for\u003c\/th\u003e\n\u003cth\u003eList price (CAD)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-4l-cs4-0-benchtop-dual-frequency\"\u003eCS4.0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 L\u003c\/td\u003e\n\u003ctd\u003e32 \/ 48 kHz\u003c\/td\u003e\n\u003ctd\u003eSingle chair, loose instruments\u003c\/td\u003e\n\u003ctd\u003e$449.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-cd4862-6l-dental\"\u003eCD-4862\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eFull cassette, five temperature presets\u003c\/td\u003e\n\u003ctd\u003e$649.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003eCS6.2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L\u003c\/td\u003e\n\u003ctd\u003e32 \/ 48 kHz\u003c\/td\u003e\n\u003ctd\u003eFull cassette, dual frequency\u003c\/td\u003e\n\u003ctd\u003e$699.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-cd4875-7-5l-dental\"\u003eCD-4875\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eLarger trays, five temperature presets\u003c\/td\u003e\n\u003ctd\u003e$849.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-8l-cs8-0-benchtop\"\u003eCS8.0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e8 L\u003c\/td\u003e\n\u003ctd\u003e49 kHz\u003c\/td\u003e\n\u003ctd\u003eTwo chairs into one cycle\u003c\/td\u003e\n\u003ctd\u003e$999.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCS20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eSeveral chairs or batch work\u003c\/td\u003e\n\u003ctd\u003e$1,199.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003ePlan the bench before the unit arrives. A loaded 20 L tank is about 37 kg on a 54 × 37 cm footprint, and it needs to sit within reach of a drain or a container you are willing to carry. Recessing it removes the lifting problem and is the reason this model has a noise-reduced cabinet.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/599bf33f4da20fb38d1771bb70a76d19.png?v=1792815581\" alt=\"Six litre benchtop ultrasonic cleaner, straight-on view of the unit with the lid closed\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch2\u003eHow do you run a repeatable cleaning cycle on the CS20?\u003c\/h2\u003e\n\n\u003cp\u003eA tank this size changes the workflow question from ‘does it fit the bench’ to ‘who owns the cycle’. One person should own the fill level, the solution change interval and the log.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eCycle set-up step by step\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStep\u003c\/th\u003e\n\u003cth\u003eSetting\u003c\/th\u003e\n\u003cth\u003eWhy it matters\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1. Fill\u003c\/td\u003e\n\u003ctd\u003e20 L working volume with solution at the label dilution\u003c\/td\u003e\n\u003ctd\u003eThe dose scales with the load, not with the tank shell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2. Heat\u003c\/td\u003e\n\u003ctd\u003eBring to the solution label temperature before the first load\u003c\/td\u003e\n\u003ctd\u003eA large tank takes longer to reach temperature; the first load is the one that gets rushed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3. Load\u003c\/td\u003e\n\u003ctd\u003eBaskets or trays, eight-transducer coverage across the length\u003c\/td\u003e\n\u003ctd\u003eEven spacing uses the whole floor instead of the centre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4. Run\u003c\/td\u003e\n\u003ctd\u003eFull cycle per load; do not add solution mid-cycle\u003c\/td\u003e\n\u003ctd\u003eAdding cold solution mid-cycle resets the working temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5. Drain, dry, record\u003c\/td\u003e\n\u003ctd\u003eElectric drain valve, dry the chamber, log the batch\u003c\/td\u003e\n\u003ctd\u003eBatch records are what a laboratory audit samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eThe failure mode on large tanks is drift: the level drops as baskets come out wet, someone tops it up with water, and after a week the concentration is half what the label says. Keep a marked fill line and change solution on a schedule, not on appearance.\u003c\/p\u003e\n\n\u003cp\u003eWhat an infection-control inspection asks for is the record, not the machine. Ontario’s provincial reprocessing guidance asks for \u003cem\u003edocumentation and maintenance of records for each component of the cleaning, disinfection and\/or sterilization process\u003c\/em\u003e, based on the manufacturer’s recommendations, and repeats that records \u003cem\u003emust be retained according to the facility’s policy\u003c\/em\u003e (\u003ca href=\"https:\/\/www.publichealthontario.ca\/-\/media\/Documents\/B\/2013\/bp-cleaning-disinfection-sterilization-hcs.pdf?rev=074097c0ef2343379b7bb17d97b75526\u0026amp;sc_lang=en\"\u003ePublic Health Ontario, “Best Practices for Cleaning, Disinfection and Sterilization of Medical Equipment\/Devices In All Health Care Settings”, 3rd edition, checked 2026-11-07\u003c\/a\u003e). A unit with a drain valve, a visible timer and a stable temperature set-point is what makes that record short enough to write at the end of a shift.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does the cETL mark cover, and what does it not?\u003c\/h2\u003e\n\n\u003cp\u003eThe CS20 sits under a different Intertek report from the smaller units — 260210005GZU-001 — which is the number to quote if a technician or an inspector asks which certificate covers this family. The mark on the unit is an ETL mark issued by Intertek, tested against \u003ca href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL73\"\u003eUL 73\u003c\/a\u003e and \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/C22.2%20NO.%2068-18\/\"\u003eCSA C22.2 No. 68\u003c\/a\u003e. It is an electrical safety certificate. It is not a UL listing and it is not CSA certification, and it says nothing about how well the tank cleans. Canadian reprocessing practice sits on a separate standard, \u003ca href=\"https:\/\/store.csastandards.org\/store\/product\/2430344\/\"\u003eCSA Z314:23\u003c\/a\u003e, whose scope puts documentation inside the reprocessing quality system rather than inside the appliance.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eWhat the electrical certificate covers, and what it does not\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCovers\u003c\/th\u003e\n\u003cth\u003eDoes not cover\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical safety of the appliance, assessed to UL 73 and CSA C22.2 No. 68\u003c\/td\u003e\n\u003ctd\u003eCleaning performance on your instruments, on your water hardness, or at your solution concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe specific unit family named on Intertek report 260210005GZU-001\u003c\/td\u003e\n\u003ctd\u003eThe condition of an individual unit after a drop, a repair, or a modification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance of the supply, plug and cord assembly for the North American market\u003c\/td\u003e\n\u003ctd\u003eAny clinical outcome, or any claim that the unit removes or inactivates micro-organisms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe identity of the certificate holder and the factory it was issued to\u003c\/td\u003e\n\u003ctd\u003eYour own reprocessing records, which are yours to keep and produce\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\n\u003ch2\u003eWhat is in the box, and what should be ordered with it?\u003c\/h2\u003e\n\n\u003cp\u003eOne cleaner, 20 L, 110 V with a North American plug and the manufacturer warranty. Basket as an accessory. Because the unit can be recessed, confirm the cut-out dimensions with us before the bench is built rather than after.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003eMulti-enzyme ultrasonic cleaning solution\u003c\/a\u003e is what goes in the tank, sold as a 1 L bottle or a 5 L pail and diluted 1:400 to 1:600. The \u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003e6 L CS6.2\u003c\/a\u003e is the unit to look at if your load grows into full cassettes. Read \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/choosing-ultrasonic-cleaner-tank-size-canadian-dental-clinic\"\u003ehow to choose a tank size\u003c\/a\u003e and \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/what-should-a-canadian-clinic-record-for-ultrasonic-cleaning-log-fields-and-retention\"\u003ewhat to record on the cleaning log\u003c\/a\u003e before you commit to a size.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does one tank fill cost in cleaning solution?\u003c\/h2\u003e\n\u003cp\u003eAt 20 L the chemistry line stops being a rounding error and starts being a purchasing decision: a full tank takes about 50 mL at 1:400, a 1 L bottle gives twenty fills and a 5 L pail a hundred. That is why batch work is costed per tank rather than per instrument — the fill, not the piece, is the unit of spend.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCS20 — concentrate per full tank and pack yield at the two label dilutions\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eDilution on the label\u003c\/th\u003e\n\u003cth\u003eConcentrate per full tank (20 L)\u003c\/th\u003e\n\u003cth\u003eFills from a 1 L bottle\u003c\/th\u003e\n\u003cth\u003eFills from a 5 L pail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1:400 — heavier soil\u003c\/td\u003e\n\u003ctd\u003e≈ 50 mL\u003c\/td\u003e\n\u003ctd\u003e20 fills\u003c\/td\u003e\n\u003ctd\u003e100 fills\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1:600 — light soil\u003c\/td\u003e\n\u003ctd\u003e≈ 33.3 mL\u003c\/td\u003e\n\u003ctd\u003e30 fills\u003c\/td\u003e\n\u003ctd\u003e150 fills\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCost per fill = the current pack price divided by the fills in that pack. Both halves of that sum move — the pack price with the market, the fills with how full you run the tank — which is why the page gives the arithmetic instead of a per-cycle figure. If your protocol changes the bath once per working day, five days a week, 20 fills is roughly 4 working weeks from one bottle.\u003c\/p\u003e\n\n\u003ch2\u003eWhich cleaning solution goes in this tank, and when should it be changed?\u003c\/h2\u003e\n\u003cp\u003eThe 20 L chamber takes the \u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003emulti-enzyme ultrasonic cleaning concentrate\u003c\/a\u003e in 1 L bottles or 5 L pails at 1:400 to 1:600. A larger tank holds a larger free surface, so the low-foam formulation is doing real work here: foam that would be a nuisance in a 4 L bath can blanket a 20 L one. Label window: 20–50 °C, 2 to 10 minutes, 24 months sealed, 90 days open.\u003c\/p\u003e\n\u003cp\u003eChange the bath when the label and your protocol say to, and record the change as part of the cleaning record — the electric drain valve on this unit exists so that a 20 L change is a routine task rather than a two-person one. Ontario reprocessing guidance asks for \u003cem\u003edocumentation and maintenance of records for each component of the cleaning, disinfection and\/or sterilization process\u003c\/em\u003e (\u003ca href=\"https:\/\/www.publichealthontario.ca\/-\/media\/Documents\/B\/2013\/bp-cleaning-disinfection-sterilization-hcs.pdf?rev=074097c0ef2343379b7bb17d97b75526\u0026amp;sc_lang=en\"\u003ePublic Health Ontario provincial reprocessing guidance, 3rd edition, checked 2026-11-07\u003c\/a\u003e).\u003c\/p\u003e\n\n\u003ch2\u003eWhat is the lead time, and what maintenance does the unit need?\u003c\/h2\u003e\n\u003cp\u003eThis unit is built to order — allow 3–4 weeks, and we confirm the dispatch date before it ships. The manufacturer warranty runs one year and is supported in Canada. CliniEco Medical holds Health Canada establishment licence (MDEL) #35334 — importer and distributor — which is separate from the warranty terms. What the unit asks of you in return is short, and mostly about the bath rather than the electronics.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCS20 — routine maintenance and why each item is on the list\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTask\u003c\/th\u003e\n\u003cth\u003eInterval\u003c\/th\u003e\n\u003cth\u003eWhy it matters\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain and refill\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAt the interval the solution label and your protocol set\u003c\/td\u003e\n\u003ctd\u003eSoil load accumulates in the bath whatever the instruments look like when they come out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRun a fresh fill before the first load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery refill\u003c\/td\u003e\n\u003ctd\u003eDissolved air in new solution damps cavitation, and the bath should be at working temperature before an instrument goes in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRinse tank and basket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery change\u003c\/td\u003e\n\u003ctd\u003eResidue left on stainless carries soil into the next fill and films the tank over time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWipe lid and check cord, plug and drain valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003ctd\u003eThe three parts a drop or a wipe-down damages first\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeep the level above the working minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery cycle\u003c\/td\u003e\n\u003ctd\u003eRunning dry is the one failure mode that ends a tank’s service life early\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWith eight transducers across the tank floor, a full tank is also a steadier tank: filling to the working level keeps the load immersed and the field even, and never letting the level fall onto the heaters is the one rule that protects the unit.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRelated reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/choosing-ultrasonic-cleaner-tank-size-canadian-dental-clinic\"\u003eChoosing an Ultrasonic Cleaner Tank Size for a Canadian Dental Clinic\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/verifying-instrument-cleaning-protein-residue-tests-tosi-and-cavitation-methods-compared\"\u003eVerifying Instrument Cleaning: Protein Residue Tests, TOSI and Cavitation Methods\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/how-much-does-an-ultrasonic-cleaner-cost-in-canada-2026-price-bands-for-clinics\"\u003eHow Much Does an Ultrasonic Cleaner Cost in Canada? 2026 Price Bands\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCliniEco Medical is a licensed medical device establishment (MDEL #35334). We are the Canadian importer of record for this unit: duties and brokerage are handled on our side, and you receive it from our Toronto warehouse with a one-year manufacturer warranty supported in Canada. Questions on which size fits your room go to our \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003esterilization desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt to order.\u003c\/strong\u003e Allow 3–4 weeks — we confirm the dispatch date before the unit ships.\u003c\/p\u003e","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":49376919781598,"sku":"CLI-ULTRA-CLEAN-200","price":1199.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CS20-HERO-logo-20261110_4db852d0-c1a2-4d5e-9a7f-5206ad0554ee_50015df7-4404-418f-ae60-9fd8ef44a91c.jpg?v=1794342778"},{"product_id":"clinieco-ultrasonic-cleaner-cd4862-6l-dental","title":"CliniEco Dental Ultrasonic Cleaner — CD-4862, 6 L with 5-Preset Heating and Timer","description":"\u003cp\u003e\u003cstrong\u003eQuick answer:\u003c\/strong\u003e A 6 L tank — cassette size — with five fixed temperature presets between 40 °C and 60 °C and a full-range 1 to 30 minute timer, so the cycle is written down rather than guessed.\u003c\/p\u003e\n\n\u003cp\u003eThe 6 L class is the size at which a standard dental instrument cassette fits in one cycle, and this is the unit in the range that treats temperature as a fixed setting rather than a dial. Five presets — 40, 45, 50, 55 and 60 °C — plus a timer that runs the whole 1 to 30 minute range, and a three-colour LED display that shows the set-point while the cycle runs. Tank opening is 32.5 × 20.4 × 9.9 cm, which takes an instrument up to 34 cm long.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eScope of use.\u003c\/strong\u003e This is a cleaning device. It removes soil — cement residue, polishing paste, dried blood in hinges and threads — as a step in instrument reprocessing. It makes no microbicidal claim, and it does not replace any later step in the workflow set out in the instrument manufacturer’s instructions for use. The \u003ca href=\"https:\/\/www.canada.ca\/en\/health-canada\/services\/drugs-health-products\/medical-devices\/application-information\/guidance-documents\/guidance-document-information-manufacturers-sterilization-reusable-medical-devices.html\"\u003eHealth Canada guidance on reprocessing information\u003c\/a\u003e is why the instrument manufacturer’s instructions — not the cleaner’s specification sheet — decide what happens to a given instrument after it comes out of the tank.\u003c\/p\u003e\n\n\u003ch2\u003eWhat are the CD-4862 specifications?\u003c\/h2\u003e\n\n\u003cp\u003eThe presets are the operational difference between this unit and a tank with a rotary thermostat: the number you set is the number you record.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eTank capacity:\u003c\/strong\u003e 6 L (6,000 ml) stainless steel\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTank opening:\u003c\/strong\u003e 32.5 × 20.4 × 9.9 cm — accepts instruments up to 34 cm long\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e 35 kHz, two industrial-grade transducers\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e 260 W rated, AC 100–120 V, 60 Hz, North American plug\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTimer:\u003c\/strong\u003e 1 to 30 minutes, full range, with three-colour LED display\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHeating:\u003c\/strong\u003e Five presets: 40 \/ 45 \/ 50 \/ 55 \/ 60 °C, with the °F equivalent shown\u003c\/p\u003e\u003ctable\u003e\n\u003ccaption\u003eCD-4862 — 6 L benchtop ultrasonic cleaner, specifications as supplied\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eField\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTank capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L (6,000 ml) stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTank dimensions\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e32.5 × 20.4 × 9.9 cm (length × width × depth), SUS304 stainless steel tank\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTank opening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32.5 × 20.4 × 9.9 cm — accepts instruments up to 34 cm long\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 kHz, two industrial-grade transducers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e260 W rated, AC 100–120 V, 60 Hz, North American plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTimer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 30 minutes, full range, with three-colour LED display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFive presets: 40 \/ 45 \/ 50 \/ 55 \/ 60 °C, with the °F equivalent shown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual heating protection, moisture-resistant PCB, detachable power cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ecETL — Intertek report 210716104GZU-001, to UL 73 and CSA C22.2 No. 68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnit, one-year manufacturer warranty; stainless basket available as an accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eList price\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAD $649.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eDoes this unit log cleaning cycles?\u003c\/h2\u003e\n\u003cp\u003eNo. The CD-4862 has no internal data logger and cannot export cycle data to a USB drive or a CSV file. If your reprocessing protocol requires machine-generated cycle records, choose a unit built for that purpose — this model is not one.\u003c\/p\u003e\n\u003cp\u003eWhat the CD-4862 gives you instead is everything needed to keep a defensible manual record: a front-panel timer that counts the cycle, a temperature set-point you can read and write down, and a drain valve so the solution-change date is unambiguous. Under CSA Z314:23 the documentation obligation sits inside your reprocessing quality system rather than inside the appliance, so a signed paper log is not a lesser record — it is the record the standard asks for.\u003c\/p\u003e\n\u003cp\u003eFive fields per cycle is enough: date, operator, temperature set-point, cycle length, and the date the solution was last changed. One line, end of shift.\u003c\/p\u003e\n\u003ch2\u003eWhich tank size in the range fits your room?\u003c\/h2\u003e\n\n\u003cp\u003eTwo 6 L units sit in this range and they are not the same product. This one fixes the temperature in 5 °C steps and runs 35 kHz; the CS6.2 runs 32 and 48 kHz on one generator. If your protocol names a temperature, the preset ladder is the easier machine to audit.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eModel range as listed — tank, frequency and the load each size is built for\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eTank\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eBuilt for\u003c\/th\u003e\n\u003cth\u003eList price (CAD)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-4l-cs4-0-benchtop-dual-frequency\"\u003eCS4.0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 L\u003c\/td\u003e\n\u003ctd\u003e32 \/ 48 kHz\u003c\/td\u003e\n\u003ctd\u003eSingle chair, loose instruments\u003c\/td\u003e\n\u003ctd\u003e$449.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCD-4862\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eFull cassette, five temperature presets\u003c\/td\u003e\n\u003ctd\u003e$649.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003eCS6.2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L\u003c\/td\u003e\n\u003ctd\u003e32 \/ 48 kHz\u003c\/td\u003e\n\u003ctd\u003eFull cassette, dual frequency\u003c\/td\u003e\n\u003ctd\u003e$699.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-cd4875-7-5l-dental\"\u003eCD-4875\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eLarger trays, five temperature presets\u003c\/td\u003e\n\u003ctd\u003e$849.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-8l-cs8-0-benchtop\"\u003eCS8.0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e8 L\u003c\/td\u003e\n\u003ctd\u003e49 kHz\u003c\/td\u003e\n\u003ctd\u003eTwo chairs into one cycle\u003c\/td\u003e\n\u003ctd\u003e$999.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-20l-cs20-bench\"\u003eCS20\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eSeveral chairs or batch work\u003c\/td\u003e\n\u003ctd\u003e$1,199.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eThe length limit is worth measuring before you buy. A 34 cm working length covers most hand instruments and many extraction forceps; anything longer belongs in a 20 L tank where the chamber is 42 cm long.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/599bf33f4da20fb38d1771bb70a76d19.png?v=1792815581\" alt=\"Six litre benchtop ultrasonic cleaner, straight-on view of the unit with the lid closed\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch2\u003eHow do you run a repeatable cleaning cycle on the CD-4862?\u003c\/h2\u003e\n\n\u003cp\u003eThis unit is built for the practice whose protocol already names a temperature. The presets exist so the number in the protocol and the number on the panel are the same number.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eCycle set-up step by step\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStep\u003c\/th\u003e\n\u003cth\u003eSetting\u003c\/th\u003e\n\u003cth\u003eWhy it matters\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1. Fill\u003c\/td\u003e\n\u003ctd\u003eSolution at the label dilution, to the working level in the tank\u003c\/td\u003e\n\u003ctd\u003eThe same fill level every day keeps the load behaviour constant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2. Preset\u003c\/td\u003e\n\u003ctd\u003eChoose 40, 45, 50, 55 or 60 °C to match the solution label\u003c\/td\u003e\n\u003ctd\u003eA fixed preset is a recordable number; a thermostat dial is an estimate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3. Load\u003c\/td\u003e\n\u003ctd\u003eInstruments in a basket or tray, joints open, not stacked\u003c\/td\u003e\n\u003ctd\u003eCavitation does not reach shielded surfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4. Time\u003c\/td\u003e\n\u003ctd\u003e1 to 30 minutes — set the interval your protocol names\u003c\/td\u003e\n\u003ctd\u003eThe full range means the timer is not the constraint on the protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5. Drain, dry, record\u003c\/td\u003e\n\u003ctd\u003eDrain through the valve, dry, then log temperature, time and operator\u003c\/td\u003e\n\u003ctd\u003eThe three data points an inspector reconstructs a cycle from\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eKeep the solution inside the temperature window printed on its label rather than at the highest preset. Hotter is not cleaner: above the solution manufacturer's range, the enzymes lose activity and the tank starts to leave a film on stainless.\u003c\/p\u003e\n\n\u003cp\u003eWhat an infection-control inspection asks for is the record, not the machine. Ontario’s provincial reprocessing guidance asks for \u003cem\u003edocumentation and maintenance of records for each component of the cleaning, disinfection and\/or sterilization process\u003c\/em\u003e, based on the manufacturer’s recommendations, and repeats that records \u003cem\u003emust be retained according to the facility’s policy\u003c\/em\u003e (\u003ca href=\"https:\/\/www.publichealthontario.ca\/-\/media\/Documents\/B\/2013\/bp-cleaning-disinfection-sterilization-hcs.pdf?rev=074097c0ef2343379b7bb17d97b75526\u0026amp;sc_lang=en\"\u003ePublic Health Ontario, “Best Practices for Cleaning, Disinfection and Sterilization of Medical Equipment\/Devices In All Health Care Settings”, 3rd edition, checked 2026-11-07\u003c\/a\u003e). A unit with a drain valve, a visible timer and a stable temperature set-point is what makes that record short enough to write at the end of a shift.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does the cETL mark cover, and what does it not?\u003c\/h2\u003e\n\n\u003cp\u003eThis unit is covered by a separate Intertek report from the CS range — 210716104GZU-001 rather than 220112139GZU-001 — which is worth knowing when a technician asks which family the certificate names. The mark on the unit is an ETL mark issued by Intertek, tested against \u003ca href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL73\"\u003eUL 73\u003c\/a\u003e and \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/C22.2%20NO.%2068-18\/\"\u003eCSA C22.2 No. 68\u003c\/a\u003e. It is an electrical safety certificate. It is not a UL listing and it is not CSA certification, and it says nothing about how well the tank cleans. Canadian reprocessing practice sits on a separate standard, \u003ca href=\"https:\/\/store.csastandards.org\/store\/product\/2430344\/\"\u003eCSA Z314:23\u003c\/a\u003e, whose scope puts documentation inside the reprocessing quality system rather than inside the appliance.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eWhat the electrical certificate covers, and what it does not\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCovers\u003c\/th\u003e\n\u003cth\u003eDoes not cover\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical safety of the appliance, assessed to UL 73 and CSA C22.2 No. 68\u003c\/td\u003e\n\u003ctd\u003eCleaning performance on your instruments, on your water hardness, or at your solution concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe specific unit family named on Intertek report 210716104GZU-001\u003c\/td\u003e\n\u003ctd\u003eThe condition of an individual unit after a drop, a repair, or a modification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance of the supply, plug and cord assembly for the North American market\u003c\/td\u003e\n\u003ctd\u003eAny clinical outcome, or any claim that the unit removes or inactivates micro-organisms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe identity of the certificate holder and the factory it was issued to\u003c\/td\u003e\n\u003ctd\u003eYour own reprocessing records, which are yours to keep and produce\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\n\u003ch2\u003eWhat is in the box, and what should be ordered with it?\u003c\/h2\u003e\n\n\u003cp\u003eOne cleaner, 6 L, 110 V with a North American plug and the manufacturer warranty. The stainless basket is an accessory. The power cord detaches, which matters in a room where the bench is wiped down between sessions.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003eMulti-enzyme ultrasonic cleaning solution\u003c\/a\u003e is what goes in the tank, sold as a 1 L bottle or a 5 L pail and diluted 1:400 to 1:600. The \u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003e6 L CS6.2\u003c\/a\u003e is the unit to look at if your load grows into full cassettes. Read \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/choosing-ultrasonic-cleaner-tank-size-canadian-dental-clinic\"\u003ehow to choose a tank size\u003c\/a\u003e and \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/what-should-a-canadian-clinic-record-for-ultrasonic-cleaning-log-fields-and-retention\"\u003ewhat to record on the cleaning log\u003c\/a\u003e before you commit to a size.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does one tank fill cost in cleaning solution?\u003c\/h2\u003e\n\u003cp\u003eThe 6 L tank is the cassette size, and it is also the worked example on the solution page: a 6 L fill needs 15 mL of concentrate at 1:400 and 10 mL at 1:600. Those two figures are the whole chemistry cost of a cassette cycle — what is left for you to check is the pack price on the day you order, because that is the only variable that moves.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCD-4862 — concentrate per full tank and pack yield at the two label dilutions\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eDilution on the label\u003c\/th\u003e\n\u003cth\u003eConcentrate per full tank (6 L)\u003c\/th\u003e\n\u003cth\u003eFills from a 1 L bottle\u003c\/th\u003e\n\u003cth\u003eFills from a 5 L pail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1:400 — heavier soil\u003c\/td\u003e\n\u003ctd\u003e≈ 15 mL\u003c\/td\u003e\n\u003ctd\u003e66 fills\u003c\/td\u003e\n\u003ctd\u003e333 fills\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1:600 — light soil\u003c\/td\u003e\n\u003ctd\u003e≈ 10 mL\u003c\/td\u003e\n\u003ctd\u003e100 fills\u003c\/td\u003e\n\u003ctd\u003e500 fills\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCost per fill = the current pack price divided by the fills in that pack. Both halves of that sum move — the pack price with the market, the fills with how full you run the tank — which is why the page gives the arithmetic instead of a per-cycle figure. If your protocol changes the bath once per working day, five days a week, 66 fills is roughly 13 working weeks from one bottle.\u003c\/p\u003e\n\n\u003ch2\u003eWhich cleaning solution goes in this tank, and when should it be changed?\u003c\/h2\u003e\n\u003cp\u003eUse the \u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003emulti-enzyme ultrasonic cleaning concentrate\u003c\/a\u003e — 1 L bottle or 5 L pail — diluted 1:400 to 1:600. It is low-foam by design, so the cavitation field does the work instead of a head of bubbles, and it is freely rinsable on stainless, anodised aluminium and plated instruments. The label window is 20–50 °C for 2 to 10 minutes; keep the bath inside it rather than at the highest preset this unit offers.\u003c\/p\u003e\n\u003cp\u003eChange the bath on the schedule your label and protocol set, and log the change with the same five fields as the cycle: date, dilution, fill level, temperature, initials. The drain valve makes the job unambiguous, and the record is the part an inspector reads — Ontario reprocessing guidance asks for \u003cem\u003edocumentation and maintenance of records for each component of the cleaning, disinfection and\/or sterilization process\u003c\/em\u003e (\u003ca href=\"https:\/\/www.publichealthontario.ca\/-\/media\/Documents\/B\/2013\/bp-cleaning-disinfection-sterilization-hcs.pdf?rev=074097c0ef2343379b7bb17d97b75526\u0026amp;sc_lang=en\"\u003ePublic Health Ontario provincial reprocessing guidance, 3rd edition, checked 2026-11-07\u003c\/a\u003e).\u003c\/p\u003e\n\n\u003ch2\u003eWhat is the lead time, and what maintenance does the unit need?\u003c\/h2\u003e\n\u003cp\u003eThis unit is built to order — allow 3–4 weeks, and we confirm the dispatch date before it ships. The manufacturer warranty runs one year and is supported in Canada. CliniEco Medical holds Health Canada establishment licence (MDEL) #35334 — importer and distributor — which is separate from the warranty terms. What the unit asks of you in return is short, and mostly about the bath rather than the electronics.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCD-4862 — routine maintenance and why each item is on the list\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTask\u003c\/th\u003e\n\u003cth\u003eInterval\u003c\/th\u003e\n\u003cth\u003eWhy it matters\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain and refill\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAt the interval the solution label and your protocol set\u003c\/td\u003e\n\u003ctd\u003eSoil load accumulates in the bath whatever the instruments look like when they come out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRun a fresh fill before the first load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery refill\u003c\/td\u003e\n\u003ctd\u003eDissolved air in new solution damps cavitation, and the bath should be at working temperature before an instrument goes in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRinse tank and basket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery change\u003c\/td\u003e\n\u003ctd\u003eResidue left on stainless carries soil into the next fill and films the tank over time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWipe lid and check cord, plug and drain valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003ctd\u003eThe three parts a drop or a wipe-down damages first\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeep the level above the working minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery cycle\u003c\/td\u003e\n\u003ctd\u003eRunning dry is the one failure mode that ends a tank’s service life early\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eA presets-based unit invites a habit worth avoiding: turning the temperature up when a load comes out dull. Above the solution label’s range the enzymes lose activity and the tank starts to film over — the fix is a fresh fill at the correct dilution, not a hotter one.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRelated reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/choosing-ultrasonic-cleaner-tank-size-canadian-dental-clinic\"\u003eChoosing an Ultrasonic Cleaner Tank Size for a Canadian Dental Clinic\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/what-should-a-canadian-clinic-record-for-ultrasonic-cleaning-log-fields-and-retention\"\u003eWhat Should a Canadian Clinic Record for Ultrasonic Cleaning?\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/enzymatic-cleaner-cost-per-litre-canada-dilution-economics\"\u003eEnzymatic Cleaner Cost per Litre in Canada: Dilution Economics\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCliniEco Medical is a licensed medical device establishment (MDEL #35334). We are the Canadian importer of record for this unit: duties and brokerage are handled on our side, and you receive it from our Toronto warehouse with a one-year manufacturer warranty supported in Canada. Questions on which size fits your room go to our \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003esterilization desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt to order.\u003c\/strong\u003e Allow 3–4 weeks — we confirm the dispatch date before the unit ships.\u003c\/p\u003e","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":49376920142046,"sku":"CLI-ULTRA-CLEAN-CD4862","price":649.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CD-4862-HERO-logo-20261110_8f343f5a-dba8-477f-a393-af8a88a4c26e_0187ef23-0d05-4267-a2ed-d61d1df230d7.jpg?v=1794342756"},{"product_id":"clinieco-ultrasonic-cleaner-cd4875-7-5l-dental","title":"CliniEco Dental Ultrasonic Cleaner — CD-4875, 7.5 L Benchtop with Heating","description":"\u003cp\u003e\u003cstrong\u003eQuick answer:\u003c\/strong\u003e 7.5 L nominal, 6,000 ml working volume, 35 kHz and 380 W, with the same five temperature presets as the 6 L unit — more room in the tank, the same size of usable load.\u003c\/p\u003e\n\n\u003cp\u003eThis is the awkward row in any ultrasonic range, and it is worth being precise about why. A 7.5 L tank (7,500 ml, or 2.0 US gallons) has a 6,000 ml working volume, which is the same usable load as the 6 L class. What the extra shell buys is headroom: longer trays fit, splashing stays inside the tank, and the unit does not have to be filled to its limit. It does not buy a second cassette.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eScope of use.\u003c\/strong\u003e This is a cleaning device. It removes soil — cement residue, polishing paste, dried blood in hinges and threads — as a step in instrument reprocessing. It makes no microbicidal claim, and it does not replace any later step in the workflow set out in the instrument manufacturer’s instructions for use. The \u003ca href=\"https:\/\/www.canada.ca\/en\/health-canada\/services\/drugs-health-products\/medical-devices\/application-information\/guidance-documents\/guidance-document-information-manufacturers-sterilization-reusable-medical-devices.html\"\u003eHealth Canada guidance on reprocessing information\u003c\/a\u003e is why the instrument manufacturer’s instructions — not the cleaner’s specification sheet — decide what happens to a given instrument after it comes out of the tank.\u003c\/p\u003e\n\n\u003ch2\u003eWhat are the CD-4875 specifications?\u003c\/h2\u003e\n\n\u003cp\u003eRead the working volume row before the capacity row. Between 6 L and 7.5 L the nominal figure moves and the usable figure does not, which is exactly the sort of detail that decides a purchase.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eTank capacity:\u003c\/strong\u003e 7.5 L nominal (7,500 ml, 2.0 US gal) — 6,000 ml working volume\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e 35 kHz\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e 380 W, AC 100–120 V, 60 Hz, North American plug\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTimer:\u003c\/strong\u003e 1 to 30 minutes\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHeating:\u003c\/strong\u003e Five presets: 40 \/ 45 \/ 50 \/ 55 \/ 60 °C\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety features:\u003c\/strong\u003e Dual heating protection, moisture-resistant PCB, detachable power cord\u003c\/p\u003e\u003ctable\u003e\n\u003ccaption\u003eCD-4875 — 7.5 L benchtop ultrasonic cleaner, specifications as supplied\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eField\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTank capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 L nominal (7,500 ml, 2.0 US gal) — 6,000 ml working volume\u003c\/td\u003e\n\u003c\/tr\u003e\n \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTank dimensions\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e33.1 × 23.8 × 10.5 cm (length × width × depth), SUS304 stainless steel tank\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 W, AC 100–120 V, 60 Hz, North American plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTimer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFive presets: 40 \/ 45 \/ 50 \/ 55 \/ 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual heating protection, moisture-resistant PCB, detachable power cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDrain valve fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ecETL — Intertek report 220112139GZU-001, to UL 73 and CSA C22.2 No. 68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnit, one-year manufacturer warranty; stainless basket available as an accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eList price\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAD $849.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eDoes this unit log cleaning cycles?\u003c\/h2\u003e\n\u003cp\u003eNo. The CD-4875 has no internal data logger and cannot export cycle data to a USB drive or a CSV file. If your reprocessing protocol requires machine-generated cycle records, choose a unit built for that purpose — this model is not one.\u003c\/p\u003e\n\u003cp\u003eWhat the CD-4875 gives you instead is everything needed to keep a defensible manual record: a front-panel timer that counts the cycle, a temperature set-point you can read and write down, and a drain valve so the solution-change date is unambiguous. Under CSA Z314:23 the documentation obligation sits inside your reprocessing quality system rather than inside the appliance, so a signed paper log is not a lesser record — it is the record the standard asks for.\u003c\/p\u003e\n\u003cp\u003eFive fields per cycle is enough: date, operator, temperature set-point, cycle length, and the date the solution was last changed. One line, end of shift.\u003c\/p\u003e\n\u003ch2\u003eWhich tank size in the range fits your room?\u003c\/h2\u003e\n\n\u003cp\u003eIf a cassette is the unit of work in your practice, the choice is 6 L or 20 L, and this size sits between them for a different reason: it gives the same 6,000 ml working load with more freeboard in the tank.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eModel range as listed — tank, frequency and the load each size is built for\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eTank\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eBuilt for\u003c\/th\u003e\n\u003cth\u003eList price (CAD)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-4l-cs4-0-benchtop-dual-frequency\"\u003eCS4.0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 L\u003c\/td\u003e\n\u003ctd\u003e32 \/ 48 kHz\u003c\/td\u003e\n\u003ctd\u003eSingle chair, loose instruments\u003c\/td\u003e\n\u003ctd\u003e$449.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-cd4862-6l-dental\"\u003eCD-4862\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eFull cassette, five temperature presets\u003c\/td\u003e\n\u003ctd\u003e$649.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003eCS6.2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L\u003c\/td\u003e\n\u003ctd\u003e32 \/ 48 kHz\u003c\/td\u003e\n\u003ctd\u003eFull cassette, dual frequency\u003c\/td\u003e\n\u003ctd\u003e$699.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCD-4875\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eLarger trays, five temperature presets\u003c\/td\u003e\n\u003ctd\u003e$849.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-8l-cs8-0-benchtop\"\u003eCS8.0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e8 L\u003c\/td\u003e\n\u003ctd\u003e49 kHz\u003c\/td\u003e\n\u003ctd\u003eTwo chairs into one cycle\u003c\/td\u003e\n\u003ctd\u003e$999.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-20l-cs20-bench\"\u003eCS20\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20 L\u003c\/td\u003e\n\u003ctd\u003e35 kHz\u003c\/td\u003e\n\u003ctd\u003eSeveral chairs or batch work\u003c\/td\u003e\n\u003ctd\u003e$1,199.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eThe practical case for this size is a bench where trays rather than cassettes are loaded — implant trays, orthodontic pliers laid out in a line, a row of handpieces that do not fit a cassette. Measure the tray first; if it fits with 2 cm to spare, this is the tank that stops the splashing.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/599bf33f4da20fb38d1771bb70a76d19.png?v=1792815581\" alt=\"Six litre benchtop ultrasonic cleaner, straight-on view of the unit with the lid closed\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\n\u003ch2\u003eHow do you run a repeatable cleaning cycle on the CD-4875?\u003c\/h2\u003e\n\n\u003cp\u003eWith more freeboard than the 6 L unit, this tank tolerates a tray that sits proud of the liquid line better than a brim-full smaller tank — but not a tray that is only half submerged. Load, then check the level.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eCycle set-up step by step\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eStep\u003c\/th\u003e\n\u003cth\u003eSetting\u003c\/th\u003e\n\u003cth\u003eWhy it matters\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1. Fill\u003c\/td\u003e\n\u003ctd\u003eTo 6,000 ml working volume with solution at the label dilution\u003c\/td\u003e\n\u003ctd\u003eThe 7.5 L figure is the shell, not the dose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2. Preset\u003c\/td\u003e\n\u003ctd\u003e40, 45, 50, 55 or 60 °C — matched to the solution label\u003c\/td\u003e\n\u003ctd\u003eEnzymes have a working window; the preset keeps you inside it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3. Load\u003c\/td\u003e\n\u003ctd\u003eTray or basket, items separated, hollow instruments flooded\u003c\/td\u003e\n\u003ctd\u003eTrapped air is the most common reason a lumen does not clean\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4. Time\u003c\/td\u003e\n\u003ctd\u003e1 to 30 minutes, set to the interval your protocol names\u003c\/td\u003e\n\u003ctd\u003eA number on the log, not an approximation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5. Drain, dry, record\u003c\/td\u003e\n\u003ctd\u003eEmpty through the valve, dry the chamber, log the cycle\u003c\/td\u003e\n\u003ctd\u003eThe record is the deliverable an inspection asks for\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eBecause the usable volume is 6,000 ml whatever the shell says, the dose of solution is the same as a 6 L unit. Buying the larger tank does not mean buying more concentrate per cycle, and a log that records a larger dose than the label ratio is the kind of small inconsistency an auditor notices.\u003c\/p\u003e\n\n\u003cp\u003eWhat an infection-control inspection asks for is the record, not the machine. Ontario’s provincial reprocessing guidance asks for \u003cem\u003edocumentation and maintenance of records for each component of the cleaning, disinfection and\/or sterilization process\u003c\/em\u003e, based on the manufacturer’s recommendations, and repeats that records \u003cem\u003emust be retained according to the facility’s policy\u003c\/em\u003e (\u003ca href=\"https:\/\/www.publichealthontario.ca\/-\/media\/Documents\/B\/2013\/bp-cleaning-disinfection-sterilization-hcs.pdf?rev=074097c0ef2343379b7bb17d97b75526\u0026amp;sc_lang=en\"\u003ePublic Health Ontario, “Best Practices for Cleaning, Disinfection and Sterilization of Medical Equipment\/Devices In All Health Care Settings”, 3rd edition, checked 2026-11-07\u003c\/a\u003e). A unit with a drain valve, a visible timer and a stable temperature set-point is what makes that record short enough to write at the end of a shift.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does the cETL mark cover, and what does it not?\u003c\/h2\u003e\n\n\u003cp\u003eThe CD-4875 is covered by Intertek report 220112139GZU-001 — the same report family as the CS units — rather than the 210716104GZU-001 report that covers the 6 L CD-4862. The mark on the unit is an ETL mark issued by Intertek, tested against \u003ca href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL73\"\u003eUL 73\u003c\/a\u003e and \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/C22.2%20NO.%2068-18\/\"\u003eCSA C22.2 No. 68\u003c\/a\u003e. It is an electrical safety certificate. It is not a UL listing and it is not CSA certification, and it says nothing about how well the tank cleans. Canadian reprocessing practice sits on a separate standard, \u003ca href=\"https:\/\/store.csastandards.org\/store\/product\/2430344\/\"\u003eCSA Z314:23\u003c\/a\u003e, whose scope puts documentation inside the reprocessing quality system rather than inside the appliance.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ccaption\u003eWhat the electrical certificate covers, and what it does not\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCovers\u003c\/th\u003e\n\u003cth\u003eDoes not cover\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical safety of the appliance, assessed to UL 73 and CSA C22.2 No. 68\u003c\/td\u003e\n\u003ctd\u003eCleaning performance on your instruments, on your water hardness, or at your solution concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe specific unit family named on Intertek report 220112139GZU-001\u003c\/td\u003e\n\u003ctd\u003eThe condition of an individual unit after a drop, a repair, or a modification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance of the supply, plug and cord assembly for the North American market\u003c\/td\u003e\n\u003ctd\u003eAny clinical outcome, or any claim that the unit removes or inactivates micro-organisms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe identity of the certificate holder and the factory it was issued to\u003c\/td\u003e\n\u003ctd\u003eYour own reprocessing records, which are yours to keep and produce\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\n\u003ch2\u003eWhat is in the box, and what should be ordered with it?\u003c\/h2\u003e\n\n\u003cp\u003eOne cleaner, 7.5 L, 110 V with a North American plug and the manufacturer warranty. Basket as an accessory. The detachable cord and the drain valve are the two features that make end-of-day cleaning quick.\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003eMulti-enzyme ultrasonic cleaning solution\u003c\/a\u003e is what goes in the tank, sold as a 1 L bottle or a 5 L pail and diluted 1:400 to 1:600. The \u003ca href=\"\/en-us\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003e6 L CS6.2\u003c\/a\u003e is the unit to look at if your load grows into full cassettes. Read \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/choosing-ultrasonic-cleaner-tank-size-canadian-dental-clinic\"\u003ehow to choose a tank size\u003c\/a\u003e and \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/what-should-a-canadian-clinic-record-for-ultrasonic-cleaning-log-fields-and-retention\"\u003ewhat to record on the cleaning log\u003c\/a\u003e before you commit to a size.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does one tank fill cost in cleaning solution?\u003c\/h2\u003e\n\u003cp\u003eThe 7.5 L unit sits between the cassette tank and the 8 L bench unit, and the difference shows up in the fill arithmetic: roughly 19 mL of concentrate per full tank at 1:400, and just over fifty fills from a 1 L bottle. Clinics that run longer trays and change the bath once a day will see a pail pay for itself in handling time long before it pays for itself in chemistry.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCD-4875 — concentrate per full tank and pack yield at the two label dilutions\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eDilution on the label\u003c\/th\u003e\n\u003cth\u003eConcentrate per full tank (7.5 L nominal capacity)\u003c\/th\u003e\n\u003cth\u003eFills from a 1 L bottle\u003c\/th\u003e\n\u003cth\u003eFills from a 5 L pail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1:400 — heavier soil\u003c\/td\u003e\n\u003ctd\u003e≈ 18.8 mL\u003c\/td\u003e\n\u003ctd\u003e53 fills\u003c\/td\u003e\n\u003ctd\u003e266 fills\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1:600 — light soil\u003c\/td\u003e\n\u003ctd\u003e≈ 12.5 mL\u003c\/td\u003e\n\u003ctd\u003e80 fills\u003c\/td\u003e\n\u003ctd\u003e400 fills\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCost per fill = the current pack price divided by the fills in that pack. Both halves of that sum move — the pack price with the market, the fills with how full you run the tank — which is why the page gives the arithmetic instead of a per-cycle figure. If your protocol changes the bath once per working day, five days a week, 53 fills is roughly 11 working weeks from one bottle.\u003c\/p\u003e\n\n\u003ch2\u003eWhich cleaning solution goes in this tank, and when should it be changed?\u003c\/h2\u003e\n\u003cp\u003eThe tank is dosed with the \u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003emulti-enzyme ultrasonic cleaning concentrate\u003c\/a\u003e, packed as 1 L or 5 L, diluted 1:400 to 1:600 in water. Low-foam formulation, working temperature 20–50 °C, cycle 2 to 10 minutes, 24 months sealed shelf life and 90 days after opening — all of it printed on the label that comes with the pack.\u003c\/p\u003e\n\u003cp\u003eThe cleaner does not decide when the bath is spent; the label and your protocol do. What this unit adds is a drain valve, so the bath is emptied through the valve instead of being lifted out, and the change goes into the record in the same minute. Ontario guidance asks for \u003cem\u003edocumentation and maintenance of records for each component of the cleaning, disinfection and\/or sterilization process\u003c\/em\u003e, retained \u003cem\u003eaccording to the facility’s policy\u003c\/em\u003e (\u003ca href=\"https:\/\/www.publichealthontario.ca\/-\/media\/Documents\/B\/2013\/bp-cleaning-disinfection-sterilization-hcs.pdf?rev=074097c0ef2343379b7bb17d97b75526\u0026amp;sc_lang=en\"\u003ePublic Health Ontario, 3rd edition, checked 2026-11-07\u003c\/a\u003e).\u003c\/p\u003e\n\n\u003ch2\u003eWhat is the lead time, and what maintenance does the unit need?\u003c\/h2\u003e\n\u003cp\u003eThis unit is built to order — allow 3–4 weeks, and we confirm the dispatch date before it ships. The manufacturer warranty runs one year and is supported in Canada. CliniEco Medical holds Health Canada establishment licence (MDEL) #35334 — importer and distributor — which is separate from the warranty terms. What the unit asks of you in return is short, and mostly about the bath rather than the electronics.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCD-4875 — routine maintenance and why each item is on the list\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTask\u003c\/th\u003e\n\u003cth\u003eInterval\u003c\/th\u003e\n\u003cth\u003eWhy it matters\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain and refill\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAt the interval the solution label and your protocol set\u003c\/td\u003e\n\u003ctd\u003eSoil load accumulates in the bath whatever the instruments look like when they come out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRun a fresh fill before the first load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery refill\u003c\/td\u003e\n\u003ctd\u003eDissolved air in new solution damps cavitation, and the bath should be at working temperature before an instrument goes in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRinse tank and basket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery change\u003c\/td\u003e\n\u003ctd\u003eResidue left on stainless carries soil into the next fill and films the tank over time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWipe lid and check cord, plug and drain valve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeekly\u003c\/td\u003e\n\u003ctd\u003eThe three parts a drop or a wipe-down damages first\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeep the level above the working minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvery cycle\u003c\/td\u003e\n\u003ctd\u003eRunning dry is the one failure mode that ends a tank’s service life early\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eLonger trays mean more shielding between instruments, so load discipline matters as much as chemistry: joints open, instruments not stacked, and the tray not resting directly on the tank floor where the transducer field is strongest and least even.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRelated reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/choosing-ultrasonic-cleaner-tank-size-canadian-dental-clinic\"\u003eChoosing an Ultrasonic Cleaner Tank Size for a Canadian Dental Clinic\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/ultrasonic-cleaning-vs-manual-scrubbing-order\"\u003eUltrasonic Cleaning vs Manual Scrubbing: Correct Order in Instrument Reprocessing\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/ultrasonic-cleaning-baths-how-to-verify\"\u003eUltrasonic Cleaning Baths: How Do You Verify They Work?\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCliniEco Medical is a licensed medical device establishment (MDEL #35334). We are the Canadian importer of record for this unit: duties and brokerage are handled on our side, and you receive it from our Toronto warehouse with a one-year manufacturer warranty supported in Canada. Questions on which size fits your room go to our \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003esterilization desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt to order.\u003c\/strong\u003e Allow 3–4 weeks — we confirm the dispatch date before the unit ships.\u003c\/p\u003e","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":49376920174814,"sku":"CLI-ULTRA-CLEAN-CD4875","price":849.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CD-4875-HERO-logo-20261110_95a68414-ed9b-4ea0-bfc9-e2ad0f6c58f1_b6f233cc-8c14-46e8-a59c-34f33f169f18.jpg?v=1794344560"}],"url":"https:\/\/clinieco.ca\/en-us\/collections\/sterilization-equipment.oembed","provider":"CliniEco Medical","version":"1.0","type":"link"}