{"title":"Equipment","description":"\u003cp\u003eEquipment is the part of a clinic build-out that gets decided late and paid for early. The lease is signed, the rooms are drawn, and then someone has to answer a deceptively simple question: what has to be on the bench before the first patient is seen, and what can wait a year. This page is the entry point for that decision — what each group of equipment does, which room it belongs in, and what has to be in place in Canada before a device can be used at all.\u003c\/p\u003e\n\u003cp\u003eWhere a specification decides a purchase — voltage, well diameter, seal width, certification standard — it is quoted from the product listing itself, not from a distributor's summary, because those two drift apart quickly.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does a Canadian clinic actually need on the equipment list?\u003c\/h2\u003e\n\u003cp\u003eMost of it falls into five groups, and only the first three are interdependent. A practice can open without magnification and without monitors; it cannot open without a way to clean, pack and verify instruments, because those three steps are what an infection-control inspection asks about.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment group\u003c\/th\u003e\n\u003cth\u003eWhat the group does in the clinic\u003c\/th\u003e\n\u003cth\u003eWhere it is usually found\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCleaning\u003c\/td\u003e\n\u003ctd\u003eLifts soil, cement residue and dried blood from instruments and cassettes before anything is packed\u003c\/td\u003e\n\u003ctd\u003eAny practice reprocessing reusable instruments: dental, veterinary, medical aesthetics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging\u003c\/td\u003e\n\u003ctd\u003eSeals pouches and rolls to a measured seam so a pack stays sterile until the point of use\u003c\/td\u003e\n\u003ctd\u003eSame room as the cleaner, wherever packs are made rather than bought pre-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncubation and readout\u003c\/td\u003e\n\u003ctd\u003eHolds a biological indicator at 56–60 °C for its full readout and reports the result\u003c\/td\u003e\n\u003ctd\u003ePractices running a daily or per-load spore test and keeping the file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnification and light\u003c\/td\u003e\n\u003ctd\u003ePuts a magnified, lit field on a single tooth or site for fine work\u003c\/td\u003e\n\u003ctd\u003eDental operatories, hygiene rooms, endodontic and surgical setups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eBlood pressure, pulse oximetry, temperature and therapy devices used chairside or at home\u003c\/td\u003e\n\u003ctd\u003eExam rooms, and in home-care and long-term-care settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe order of that table is the order of the spend. Clinics that buy the optics first and the reprocessing bench last usually end up running instruments through a tank that is too small for a cassette, which is a problem the machine cannot solve afterwards.\u003c\/p\u003e\n\n\u003ch2\u003eWhich room does each piece belong in?\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSterilization room.\u003c\/strong\u003e Four units share one bench, and the job each one does is the reason the bench has a sequence. Cleaning comes first: the \u003ca href=\"https:\/\/clinieco.ca\/products\/clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency\"\u003eCS6.2 ultrasonic cleaner\u003c\/a\u003e is a 6 L tank — the size at which a full instrument cassette fits in one cycle — with 32 kHz for heavier soil and 48 kHz for lumens and threaded joints. It cleans; it does not sterilise, and no ultrasonic unit does. Packing follows, and a \u003ca href=\"https:\/\/clinieco.ca\/products\/clinieco-constant-heat-pouch-sealer-200-c-12mm-seal-110v-dental-sterilization\"\u003econstant-heat pouch sealer\u003c\/a\u003e earns its bench space in exactly two cases: packs longer or wider than a stocked pouch, and rolls cut to the length actually needed. Verification is the third job, and it is one purchase or two: a \u003ca href=\"https:\/\/clinieco.ca\/products\/dlab-hb120-s-led-digital-dry-bath-incubator\"\u003e20-well dry-block incubator\u003c\/a\u003e for 24-hour vials read by colour, or a \u003ca href=\"https:\/\/clinieco.ca\/products\/clinieco-24-hour-biological-indicator-incubator-precision-dry-block-15-wells\"\u003e24-hour incubator with USB export\u003c\/a\u003e where the temperature record has to leave the unit. A \u003ca href=\"https:\/\/clinieco.ca\/products\/clinieco-rapid-reader-4-well-fluorescence-biological-indicator-reader\"\u003e4-well fluorescence reader\u003c\/a\u003e only applies if the daily test is a rapid-readout indicator, and it ships as the instrument alone — the ampoules are a separate consumable, and one without the other reports nothing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExam and treatment room.\u003c\/strong\u003e Working distance is fixed per pair of loupes, so a clinician is measured before the order rather than fitted after it. The \u003ca href=\"https:\/\/clinieco.ca\/products\/clinieco-flip-up-dental-loupes-2-5x-magnification-adjustable-lightweight\"\u003e2.5× flip-up pair\u003c\/a\u003e, set to a working distance between 350 and 500 mm and adjustable for interpupillary distance, suits general dentistry and hygiene; the \u003ca href=\"https:\/\/clinieco.ca\/products\/clinieco-flip-up-dental-loupes-3-5x-magnification-adjustable-lightweight\"\u003e3.5× prism pair\u003c\/a\u003e shows a smaller field and belongs on endodontic and surgical work. Light is a separate decision rather than an accessory: the \u003ca href=\"https:\/\/clinieco.ca\/products\/clinieco-wireless-dental-headlight-core-35k-lux-ultra-light-for-loupes\"\u003eCore wireless headlight\u003c\/a\u003e mounts on the same universal T-mount, adds roughly 12 g at the lamp head and charges over USB-C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHome and bedside.\u003c\/strong\u003e Monitors are bought for a patient rather than for a room, and get replaced one at a time, so they are grouped on the \u003ca href=\"https:\/\/clinieco.ca\/collections\/health-monitors\"\u003ehealth monitors page\u003c\/a\u003e rather than here.\u003c\/p\u003e\n\n\u003ch2\u003eWhat has to be in place before a device can be used in a Canadian clinic?\u003c\/h2\u003e\n\u003cp\u003eThree things, and they are checked in this order by anyone who inspects the room.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImporter and licence.\u003c\/strong\u003e A device sold into Canada is imported by a company holding a Medical Device Establishment Licence, and the device itself sits under a licence or registration appropriate to its class. CliniEco Medical holds MDEL #35334, and licence numbers are stated on the listings that carry one. A supplier who cannot produce a licence number on request has ended the conversation rather than started it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical certification for a Canadian supply.\u003c\/strong\u003e Certification is issued against named standards, so the standard is what you ask for — not the word \"certified\". On this bench that means cETL by Intertek to CSA C22.2 No. 68 and UL 73 on the ultrasonic tank, and on the DLAB incubator cTUVus by TÜV Rheinland, certificate CU 72205506 0001, tested to UL 61010-1 and CAN\/CSA-C22.2 No. 61010-1-12, with FCC Part 15 Subpart B and ICES-001 registrations on file. Voltage and frequency belong in the same check: 110 V \/ 60 Hz is the working assumption for a Canadian room, and a unit built for another supply needs a transformer before it needs bench space.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReprocessing practice.\u003c\/strong\u003e Equipment supports a documented process; it does not create one. CSA Z314:23 is the current Canadian standard for reprocessing reusable medical devices in health care settings, and what an inspection looks for is the record behind each load — which cycle ran, which indicator was used, what it read, and who signed it off. A reader that stores results or an incubator that exports them helps you produce that file. Neither one writes it for you.\u003c\/p\u003e\n\n\u003ch2\u003eWhat should you ask a supplier before you commit?\u003c\/h2\u003e\n\u003cp\u003eSix questions, in this order. They are what separates a quotation from a purchase order.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eWhich licence or registration covers this device, and what is the number?\u003c\/li\u003e\n\u003cli\u003eWhich standards is the unit certified to, by which body, and what certificate number appears on the label?\u003c\/li\u003e\n\u003cli\u003eWhat is in the box at the quoted configuration — block, basket, lid, battery, spare — and what is priced separately?\u003c\/li\u003e\n\u003cli\u003eHow is temperature or output verified, and does the unit keep or export a record, or does the record stay on paper?\u003c\/li\u003e\n\u003cli\u003eWhat consumable does the device depend on, is the format proprietary, and what is the reorder part number?\u003c\/li\u003e\n\u003cli\u003eWho services the unit in Canada, what is the warranty term, and how long does a replacement part take to arrive?\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat to put in front of the supplier\u003c\/th\u003e\n\u003cth\u003eWhat a usable answer looks like\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice licensing\u003c\/td\u003e\n\u003ctd\u003eAsk for the licence or registration number covering the device\u003c\/td\u003e\n\u003ctd\u003eA number in writing, matched to the model on the quotation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical certification\u003c\/td\u003e\n\u003ctd\u003eAsk for the certification body and the standard numbers\u003c\/td\u003e\n\u003ctd\u003eIssuer plus standards plus certificate number, not a logo alone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply compatibility\u003c\/td\u003e\n\u003ctd\u003eAsk for the nameplate voltage and frequency\u003c\/td\u003e\n\u003ctd\u003e110 V \/ 60 Hz stated, or the transformer requirement stated with it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature control\u003c\/td\u003e\n\u003ctd\u003eAsk how accuracy is stated and how it is confirmed in the room\u003c\/td\u003e\n\u003ctd\u003eA tolerance figure plus the method used to verify it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecords\u003c\/td\u003e\n\u003ctd\u003eAsk whether the unit logs, prints or exports, and in what format\u003c\/td\u003e\n\u003ctd\u003eA plain answer either way; a unit with no export should say so\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArrival and service\u003c\/td\u003e\n\u003ctd\u003eAsk what is checked on delivery and who repairs it locally\u003c\/td\u003e\n\u003ctd\u003eA named Canadian service contact and a warranty term in months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eHow do you receive and document equipment after it arrives?\u003c\/h2\u003e\n\u003cp\u003eUnpack in the room it will live in, not in a corridor, and do it while the delivery paperwork is still on the counter. Three things get recorded before the carton is broken down: the serial number as printed on the plate, the contents against the packing list, and any damage to the housing or the cord — photographed the same day, because a carrier claim made a week later is a harder conversation.\u003c\/p\u003e\n\u003cp\u003eThen the asset register, one line per device: purchase date, serial number, warranty end, service agent, and where its documentation is filed. The maintenance record sits beside it, and on a reprocessing bench the maintenance record and the load record are in practice the same file — the week the sealer was serviced and the week a pack sealed badly tend to be the same week. Printable load and spore logs are kept in the \u003ca href=\"https:\/\/clinieco.ca\/pages\/compliance-log-center\"\u003ecompliance log centre\u003c\/a\u003e, and they are worth printing before the first cycle rather than after the first inspection.\u003c\/p\u003e\n\n\u003ch2\u003eWhere do multi-site and institutional orders go?\u003c\/h2\u003e\n\u003cp\u003eA five-chair clinic and a twelve-site long-term-care group do not buy equipment the same way. The second needs purchase orders, delivery windows, an asset list per site and one invoice instead of twelve. Institutional supply — clinics, dental groups, long-term care, schools and government buyers — is handled through the \u003ca href=\"https:\/\/clinieco.ca\/pages\/wholesale\"\u003einstitutional supply enquiry\u003c\/a\u003e, and a mixed order of equipment and consumables is quoted as one basket rather than line by line.\u003c\/p\u003e\n\n\u003ch2\u003eWhat this page deliberately leaves out\u003c\/h2\u003e\n\u003cp\u003eSteam sterilization itself. Which sterilizer to buy, how to load it, which cycle to run and how to validate a chamber are questions with their own answers, and they sit on the \u003ca href=\"https:\/\/clinieco.ca\/collections\/sterilization-equipment\"\u003esterilization and ultrasonic equipment page\u003c\/a\u003e — including the fact that the Class B benchtop unit we list is a pre-launch listing and not yet a purchasable model. This page is the way into the equipment range, not a substitute for that one.\u003c\/p\u003e\n","products":[{"product_id":"clinieco-rapid-reader-4-well-fluorescence-biological-indicator-reader","title":"CliniEco Rapid Reader — 4-Well Fluorescence Biological Indicator Reader (20-Minute \/ 1-Hour \/ 3-Hour Readout)","description":"\u003cdiv style=\"border:1px solid #E9EEF2;border-radius:8px;padding:14px 16px;margin:0 0 18px 0;background:#F7FAFB\"\u003e\n\u003cstrong\u003eQuoted per order\u003c\/strong\u003e — this unit is supplied against a confirmed order. Send us your clinic's requirements and we will confirm lead time and price. \u003ca href=\"\/en-us\/pages\/wholesale\"\u003eRequest a quote\u003c\/a\u003e\n\u003c\/div\u003e\u003cdiv class=\"clini-prod\"\u003e\n  \u003cdiv class=\"clini-prod-hero\"\u003e\n    \n\u003ch2 class=\"clini-prod-title\"\u003e⚡ CliniEco Rapid Reader\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eThis listing is the instrument that reads fluorescent biological indicators — not the indicators themselves.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cp\u003eInstrument-read fluorescence results — \u003cstrong\u003e20 minutes \/ 1 hour \/ 3 hours with our rapid-readout BIs\u003c\/strong\u003e (steam rapid modes per the reader manufacturer's technical data sheet)\u003c\/p\u003e\n    \u003cp\u003e4-well fluorescence reader for biological indicators\u003c\/p\u003e\n    \n  \u003c\/div\u003e\n\u003cp\u003eWhat ships is the reader: a four-well bench unit, model TR-R30MP4, holding ampoules at 56-60 °C and reporting a positive or negative fluorescence result. The ampoules are consumables bought separately; none of this page's $1,499 CAD is a box of tests, and an ampoule on its own cannot report a result.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/how-often-us-vs-canadian-clinics-sterilizer-testing-incubator-guide\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/Reader01_2400sq.png?v=1793406845\" alt=\"CliniEco Rapid Reader — 4-Well Fluorescence Biological Indicator Reader (20-Minute \/ 1-Hour \/ 3-Hour Readout)\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eIs this the reader or the indicators?\u003c\/h2\u003e\n\u003cp\u003eThis page sells the reader only. The ampoules it reads are stocked as separate 50-packs and reordered monthly, so a clinic needs both lines to get a result: the instrument once, the vials continuously. The price gap shows which is which — the hardware is priced on this page, the fluorescence vials are priced per 50-pack on their own pages, and the per-test figure follows there by dividing. Opening the ampoule page when you meant the reader, or the reverse, costs a cycle: no vial means no test that day.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eReader or indicators — which purchase applies to your clinic (CliniEco, checked October 2026)\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBuy the Rapid Reader if…\u003c\/th\u003e\n\u003cth\u003eBuy only the indicators if…\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eYour daily spore test uses a 20-minute fluorescence ampoule\u003c\/td\u003e\n\u003ctd\u003eYour daily spore test uses a 24-hour self-contained vial read by colour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eYour daily spore test uses a 1-hour fluorescence ampoule\u003c\/td\u003e\n\u003ctd\u003eYou read that colour change by eye after overnight incubation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eYour daily spore test uses a 3-hour fluorescence ampoule\u003c\/td\u003e\n\u003ctd\u003eNext-morning results already fit the way your day opens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eYou want the positive or negative result reported by the instrument\u003c\/td\u003e\n\u003ctd\u003eYou judge the result yourself against the unincubated control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eYou want the result stored on the device and exported over USB\u003c\/td\u003e\n\u003ctd\u003eA paper log sheet is the record you keep and file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eYou are moving a clinic from visual to instrument-read monitoring\u003c\/td\u003e\n\u003ctd\u003eYou already own a reader that takes your current ampoules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhich biological indicators work with this reader, and what do they cost per test?\u003c\/h2\u003e\n\u003cp\u003eThree fluorescence rapid-readout 50-packs fit this instrument, and the readout time is set by the ampoule rather than by the reader: the \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-20-minute-rapid-readout-50-pack\"\u003e20-minute 50-pack\u003c\/a\u003e, the \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-1-hour-rapid-readout-50-pack\"\u003e1-hour 50-pack\u003c\/a\u003e and the \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-3-hour-rapid-readout-fluorescence-50-pack\"\u003e3-hour 50-pack\u003c\/a\u003e, each priced on its own page with the per-test figure following from the pack amount. The ampoules are sold separately and are not covered by the price of this instrument. Wells accept 8-11 mm ampoules and hold four at a time. The \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-50-pack\"\u003e24-hour self-contained 50-pack\u003c\/a\u003e is a different product type and is not read by this instrument.\u003c\/p\u003e\n\u003ch2\u003eDo I need this reader if I use 24-hour self-contained BIs?\u003c\/h2\u003e\n\u003cp\u003eNo. A 24-hour self-contained vial carries its own medium and turns colour when spores survive; after incubation the result is read by eye against a control, with no instrument in the loop. Pairing that vial with this reader adds $1,499 CAD of equipment the vial cannot use, because the wells are heated and optically read for fluorescence ampoules. The decision is therefore about which readout tier your working day needs: the 24-hour vial and the rapid ampoule carry different per-test figures, each set by the price shown on its own 50-pack page, while a fluorescence tier buys the same-day answer that lets a load return to the chair or the tray before the next cycle.\u003c\/p\u003e\n\u003cp\u003ePut the choice on paper before the purchase order goes out: the \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003espore-test log sheet\u003c\/a\u003e shows the column your daily record has to fill, the \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003esterilization log generator\u003c\/a\u003e turns four wells a day into a month of entries, and the \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003ecompliance desk\u003c\/a\u003e will answer the reader-versus-ampoule question in writing, citing the regulation it relies on. This reader reaches Canada under establishment number MDEL #35334, held by CliniEco Medical, Toronto.\u003c\/p\u003e\n\n\n\n\n  \u003cdiv class=\"clini-prod-benefit\"\u003e\n    \u003cp\u003e✅ \u003cstrong\u003eReads rapid fluorescence BI ampoules\u003c\/strong\u003e (20 min \/ 1 h \/ 3 h with our rapid-readout BIs) | ✅ \u003cstrong\u003eOur 24-hour BIs are self-contained and read visually — no reader needed\u003c\/strong\u003e | ✅ \u003cstrong\u003eNo locked equipment\u003c\/strong\u003e — works with standard BI ampoules | ✅ \u003cstrong\u003eFluorescence readout\u003c\/strong\u003e (positive\/negative) | ✅ \u003cstrong\u003eDaily RCDSO\/PHO biological monitoring ready\u003c\/strong\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"clini-price-box\"\u003e\n    \u003cp style=\"margin:0;font-size:14px;color:#6b7280;\"\u003eCompare: 3M Attest Mini Auto-reader 490M — \u003cstrong\u003eCAD 1,162–1,410\u003c\/strong\u003e at four Canadian distributors (Clinical Research Dental, 3B Dahabi, 3Z Dental, United Canada), read 30 Oct 2026\u003c\/p\u003e\n    \u003cp style=\"margin:4px 0;\"\u003e\u003cspan class=\"old\"\u003e\u003c\/span\u003e \u003cspan class=\"new\"\u003e$1,499 CAD\u003c\/span\u003e\u003c\/p\u003e\n    \u003cspan class=\"save\"\u003eLaunch price — professional-grade 4-well fluorescence reader\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"background:linear-gradient(135deg,#123a2f 0%,#206270 100%);border-radius:14px;padding:24px 24px;color:#fff;margin:20px 0;text-align:center;\"\u003e\n    \u003ch2 style=\"margin:0 0 8px;font-size:1.4rem;\"\u003eSold on its own — $1,499 CAD\u003c\/h2\u003e\n    \u003cp style=\"margin:4px 0;font-size:1rem;opacity:.95;\"\u003eThis reader is $1,499 CAD, with no term and nothing to commit to. Our 3-hour indicators are priced per 50-pack on their own page.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e$1,499 CAD — fully deductible against your rapid BIs.\u003c\/strong\u003e Buy the reader now and, within 12 months, the full $1,499 CAD comes back to you as credit on rapid BI purchases once you have ordered $1,500 CAD of rapid BIs. Net cost of the hardware: $0 CAD. The credit applies to the reader only, caps at $1,499 CAD, and does not stack with other offers.\u003c\/p\u003e\n    \u003cp style=\"margin:8px 0 0;font-size:0.9rem;opacity:.85;\"\u003eNo locked equipment · Works with standard rapid BI ampoules · Same-day compliance results\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv style=\"background:#f0f7ff;border:2px solid #206270;border-radius:10px;padding:16px;margin:16px 0;\"\u003e\n    \u003cp style=\"margin:0;font-size:14.5px;color:#333;\"\u003e🎁 \u003cstrong\u003eBuy the Reader — Get 1 Month of Rapid BIs FREE\u003c\/strong\u003e — order today and we'll include \u003cstrong\u003e50 rapid BI tests — one full month, a $249.99 CAD value (our 3-hour 50-pack)\u003c\/strong\u003e at no charge. Try the full rapid workflow from day one.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch2 style=\"font-size:1.3rem;margin:24px 0 8px;\"\u003eWhy switch from 24-hour tests?\u003c\/h2\u003e\n  \u003cul style=\"margin:16px 0;padding-left:20px;\"\u003e\n    \u003cli style=\"margin:8px 0;\"\u003e⏱️ \u003cstrong\u003eResults in 20 minutes, 1 hour or 3 hours with our rapid-readout BIs — know same-day if your sterilizer passed\u003c\/strong\u003e\n\u003c\/li\u003e\n    \u003cli style=\"margin:8px 0;\"\u003e💰 \u003cstrong\u003eBI priced per vial on that vial's own page\u003c\/strong\u003e — the per-test figure is that page's 50-pack price divided by fifty, and 3M Attest rapid-readout ampoules are priced by channel, so set both figures from your own quotations rather than from a summary line here\u003c\/li\u003e\n    \u003cli style=\"margin:8px 0;\"\u003e🔓 \u003cstrong\u003eThree readout tiers on one instrument\u003c\/strong\u003e — this reader takes standard 8–11 mm ampoules across the 20-minute, 1-hour and 3-hour tiers, while the 3M Attest Mini Auto-reader 490M reads only its own closed set of 24-minute rapid ampoules (per 3M IFU)\u003c\/li\u003e\n    \u003cli style=\"margin:8px 0;\"\u003e✅ \u003cstrong\u003eDaily compliance made easy\u003c\/strong\u003e — required by RCDSO\/PHO, results when you need them\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cdiv class=\"clini-trust\"\u003e\n    \u003ch3\u003e🛡️ Built to Clinical Standards — Inside This Reader\u003c\/h3\u003e\n    \u003cdiv class=\"clini-trust-grid\"\u003e\n      \u003cdiv class=\"clini-trust-item\"\u003e\n        \u003ch4\u003e🔬 Precision Optical Detection\u003c\/h4\u003e\n        \u003cp\u003eBlue LED excitation (~460nm) + silicon photodiode sensor with bandpass filter, in a light-sealed optical chamber — the same detection principle used by major brands, delivering clear positive\/negative fluorescence readouts.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"clini-trust-item\"\u003e\n        \u003ch4\u003e🌡️ 58°C ± 2°C Culture Temperature\u003c\/h4\u003e\n        \u003cp\u003ePID-controlled PTC heating block with NTC temperature sensor, holding a 58°C culture temperature (±2°C), i.e. 56-60°C — critical for accurate BI results.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"clini-trust-item\"\u003e\n        \u003ch4\u003e⚙️ Industrial-Grade Mainboard\u003c\/h4\u003e\n        \u003cp\u003eARM-based microcontroller with on-board memory (10,000+ result log), real-time clock, USB data export — audit-ready record keeping built in.\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"clini-trust-item\"\u003e\n        \u003ch4\u003e🔌 Robust Power \u0026amp; Build\u003c\/h4\u003e\n        \u003cp\u003e100-240V AC worldwide power adapter, injection-molded enclosure, 2-year warranty with Toronto-based support.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHave a question about your own facility?\u003c\/strong\u003e Send it in and you will get a written answer specific to your setup, with the regulation or standard it is based on cited. \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003eAsk your compliance question\u003c\/a\u003e.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"clini-cert-row\"\u003e\n      \u003cspan class=\"clini-cert-chip\"\u003e✅ FCC Compliant\u003c\/span\u003e\n      \n      \u003cspan class=\"clini-cert-chip\"\u003e✅ 2-Year Warranty\u003c\/span\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2 style=\"font-size:1.3rem;margin:24px 0 8px;\"\u003eHow We Compare — Spec by Spec\u003c\/h2\u003e\n  \u003ctable class=\"clini-prod-spec\"\u003e\n    \u003ctr\u003e\n\u003cth style=\"width:32%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eCliniEco Rapid Reader\u003c\/th\u003e\n\u003cth\u003e3M Attest 490M\u003c\/th\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWells\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDetection Method\u003c\/td\u003e\n\u003ctd\u003eFluorescence enzyme (LED + photodiode)\u003c\/td\u003e\n\u003ctd\u003eFluorescence (proprietary)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eReadout Time\u003c\/td\u003e\n\u003ctd\u003e3 hours with CliniEco 3-hour rapid BIs\u003c\/td\u003e\n\u003ctd\u003e24 min with 3M super-rapid BIs (per 3M IFU)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e56-60°C (58°C ± 2°C setpoint)\u003c\/td\u003e\n\u003ctd\u003e60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBI Compatibility\u003c\/td\u003e\n\u003ctd\u003eOpen — 8-11 mm fluorescence BI ampoules, no lock-in; the BI's rapid mode must match 20 min \/ 1 h \/ 3 h (manufacturer compatibility statement)\u003c\/td\u003e\n\u003ctd\u003eLocked to 3M Attest BIs\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003e10,000+ results, USB export\u003c\/td\u003e\n\u003ctd\u003eAttest Connect (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eReader Price\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e$1,499 CAD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eCAD 1,162–1,410\u003c\/strong\u003e (4 distributors, read 30 Oct 2026)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd\u003eBI Price (per test)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSee each 50-pack page\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSee the 3M dealer's box-of-50 price\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:1.3rem;margin:24px 0 8px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n  \u003ctable class=\"clini-prod-spec\"\u003e\n    \u003ctr\u003e\n\u003cth style=\"width:35%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTR-R30MP4 (4-well rapid fluorescence reader)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDetection Method\u003c\/td\u003e\n\u003ctd\u003eFluorescence enzyme (α-glucosidase + fluorescent substrate)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eReadout Time\u003c\/td\u003e\n\u003ctd\u003e3 hours (our 3-hour rapid BIs)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWells\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCompatible Ampoules\u003c\/td\u003e\n\u003ctd\u003eRapid BI ampoules Φ8-11 mm; rapid mode must match 20 min \/ 1 h \/ 3 h\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eClear positive\/negative readout\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e110V\/60Hz (North America)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e56-60°C (58°C ± 2°C setpoint)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eSteam sterilization monitoring (daily RCDSO\/PHO compliance)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eManufacturer documentation available on request\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eImport\u003c\/td\u003e\n\u003ctd\u003eCliniEco Medical, Toronto, ON\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003ch2 style=\"font-size:1.3rem;margin:24px 0 8px;\"\u003eHow it works\u003c\/h2\u003e\n  \u003col style=\"margin:16px 0;padding-left:20px;\"\u003e\n    \u003cli style=\"margin:6px 0;\"\u003eRun your daily sterilization cycle\u003c\/li\u003e\n    \u003cli style=\"margin:6px 0;\"\u003ePlace a rapid BI ampoule in the reader\u003c\/li\u003e\n    \u003cli style=\"margin:6px 0;\"\u003eGet the instrument-read result at the indicator's readout time (3 h with our 3-hour rapid BIs) — positive or negative\u003c\/li\u003e\n    \u003cli style=\"margin:6px 0;\"\u003eRecord results for RCDSO\/PHO audit compliance\u003c\/li\u003e\n  \u003c\/ol\u003e\n\n  \u003ca href=\"\/en-us\/pages\/wholesale\" class=\"clini-prod-cta\"\u003eRequest a quote for the Rapid Reader →\u003c\/a\u003e\n\n  \u003cp class=\"clini-prod-note\"\u003eSold on its own at $1,499 CAD, with no plan and no term.\u003cbr\u003e\n  Questions? Email \u003ca href=\"mailto:alina@clinieco.ca\"\u003ealina@clinieco.ca\u003c\/a\u003e · +1 (437) 466-2232\u003c\/p\u003e\n  \u003cp class=\"clini-prod-note\"\u003eCliniEco Medical · Toronto, ON\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-guides-block\"\u003e\n\u003ch3\u003eRelated Guides\u003c\/h3\u003e\n\u003cp\u003eLearn how to choose and use this product correctly:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/sterility-assurance-level-sal-explained-what-10-6-means-for-sterilization\"\u003eSterility Assurance Level (SAL) Explained: What 10-6 Means for Sterilization\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/what-to-do-when-a-biological-indicator-test-fails\"\u003eBiological Indicator Failure: Recall, Root Cause, and Re-Test Protocol\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/class-4-vs-class-5-vs-class-6-sterilization-indicators-what-each-level-means\"\u003eClass 4 vs 5 vs 6 Sterilization Indicators: Which Do You Need?\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/how-often-should-you-run-a-spore-test-sterilizer-monitoring-schedules\"\u003eHow Often Should You Run a Spore Test? Sterilizer Monitoring Schedules\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n .clini-prod { max-width:760px; margin:0 auto; font-family:-apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, sans-serif; color:#111827; }\n .clini-prod-hero { background:linear-gradient(135deg,#206270 0%,#2A5C8A 100%); border-radius:14px; padding:32px 28px; color:#fff; text-align:center; margin-bottom:24px; }\n .clini-prod-hero.clini-prod-title { font-size:1.9rem; margin:0 0 8px; font-weight:800; }\n .clini-prod-hero p { font-size:1.05rem; margin:4px 0; opacity:0.95; }\n .clini-prod-badge { display:inline-block; background:rgba(255,255,255,0.2); border:1px solid rgba(255,255,255,0.5); border-radius:20px; padding:4px 14px; font-size:0.85rem; margin-top:10px; }\n .clini-prod-benefit { background:#f0f7ff; border:1px solid #2A5C8A; border-radius:10px; padding:16px; margin:16px 0; }\n .clini-prod-benefit p { margin:0; font-size:14.5px; color:#333; }\n .clini-prod-cta { display:block; text-align:center; background:#206270; color:#fff; text-decoration:none; border-radius:10px; padding:16px 24px; font-weight:700; font-size:17px; margin:20px 0; }\n .clini-prod-cta:hover { background:#1645c7; }\n .clini-prod-spec { width:100%; border-collapse:collapse; margin:16px 0; font-size:14px; }\n .clini-prod-spec th { background:#2A5C8A; color:#fff; padding:10px 12px; text-align:left; }\n .clini-prod-spec td { padding:10px 12px; border-bottom:1px solid #e5e7eb; }\n .clini-prod-spec tr:nth-child(even) { background:#f9fafb; }\n .clini-prod-note { text-align:center; color:#6b7280; font-size:13px; margin-top:10px; }\n .clini-price-box { background:#fff7ed; border:2px solid #f97316; border-radius:10px; padding:20px; text-align:center; margin:20px 0; }\n .clini-price-box.old { color:#9ca3af; text-decoration:line-through; font-size:16px; }\n .clini-price-box.new { color:#ea580c; font-size:32px; font-weight:800; }\n .clini-price-box.save { background:#f97316; color:#fff; display:inline-block; padding:4px 12px; border-radius:20px; font-size:14px; font-weight:600; margin-top:8px; }\n .clini-trust { background:#f8fafc; border:1px solid #d1d5db; border-radius:12px; padding:20px; margin:20px 0; }\n .clini-trust h3 { margin:0 0 12px; font-size:1.1rem; color:#123a2f; }\n .clini-trust-grid { display:grid; grid-template-columns:1fr 1fr; gap:12px; }\n .clini-trust-item { background:#fff; border:1px solid #e5e7eb; border-radius:8px; padding:12px; }\n .clini-trust-item h4 { margin:0 0 4px; font-size:0.95rem; color:#206270; }\n .clini-trust-item p { margin:0; font-size:13px; color:#4b5563; line-height:1.5; }\n .clini-cert-row { display:flex; flex-wrap:wrap; gap:8px; margin-top:12px; }\n .clini-cert-chip { background:#e8f1f5; color:#123a2f; border-radius:20px; padding:5px 14px; font-size:12.5px; font-weight:600; }\n\u003c\/style\u003e\n\n\u003c!-- bi-family-crosslink v1 --\u003e\n\u003ch3\u003eRelated tests in this BI line\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-clinic-starter-bundle-gloves-spore-testing-sterilization-packaging\"\u003eClinic Starter Bundle — Gloves, Spore Testing \u0026amp; Sterilization Packaging\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-24-hour-biological-indicator-incubator-precision-dry-block-15-wells\"\u003eCliniEco 24-Hour Biological Indicator Incubator — Precision Dry-Block, 24 Wells\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-1-hour-rapid-readout-50-pack\"\u003eCliniEco Medical Biological Indicator — 1-Hour Rapid Readout, Fluorescence, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-20-minute-rapid-readout-50-pack\"\u003eCliniEco Medical Biological Indicator — 20-Minute Rapid Readout, Fluorescence, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-100-pack\"\u003eCliniEco Medical Biological Indicator — 24-Hour Self-Contained, 100-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003eCliniEco Medical Biological Indicator — 24-Hour Self-Contained, 25-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-50-pack\"\u003eCliniEco Medical Biological Indicator — 24-Hour Self-Contained, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-3-hour-rapid-readout-fluorescence-50-pack\"\u003eCliniEco Medical Biological Indicator — 3-Hour Rapid Readout, Fluorescence, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/pages\/bi-sample-request\"\u003eFree Biological Indicator 5-Pack (clinics)\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-bowie-dick-test-pack-iso-11140-5-type-2-daily-vacuum-check-6-pack\"\u003eCliniEco Medical Bowie-Dick Test Pack — ISO 11140-5 Type 2, Daily Vacuum Check, 6-Pack\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/how-to-choose-biological-indicator-incubator-canadian-clinic\"\u003eHow to Choose a Biological Indicator Incubator for a Canadian Clinic\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/24-hour-self-contained-biological-indicator-pack-sizes-incubation-record\"\u003e24-Hour Self-Contained Biological Indicators: Pack Sizes, Incubation and the Record\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/which-standards-medical-biological-indicator-us-vs-canada\"\u003eWhich Standards Apply to Medical Biological Indicator in the US vs Canada? Sizes and Sourcing\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/which-standards-hb105-s2-dry-bath-incubator-us-vs-canada\"\u003eWhich Standards Apply to HB105-S1 Dry Bath Incubator with Lid in the US vs Canada? Sizes and Sourcing\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":48763291762910,"sku":"CLI-RR-004","price":1499.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/READER-HERO-logo-20261110_6c6c68d1-61ce-4d5f-a376-fd915de29912_2f79a230-d1d6-4131-a722-b77e3c817a69.jpg?v=1794344612"},{"product_id":"clinieco-24-hour-biological-indicator-incubator-precision-dry-block-15-wells","title":"CliniEco 24-Hour Biological Indicator Incubator — Precision Dry-Block, 24 Wells","description":"\u003ch2\u003eWhich biological indicator vials seat properly in this dry block?\u003c\/h2\u003e\n\u003cp\u003eThe block is machined with twenty-four wells of eight point eight millimetres across, cut to the outside diameter of a self-contained spore ampoule, so a standard tube drops in flush and the aluminium wall carries heat the whole length of the vial. A wider cap will not enter the well at all, and an undersized tube sits loose with an air gap around it, which is the usual reason one indicator in a batch reads late. Anything used here has to be read at 56 to 60 degrees C, the growth band for \u003cem\u003eGeobacillus stearothermophilus\u003c\/em\u003e; the \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-50-pack\"\u003e24-hour spore test ampoules\u003c\/a\u003e match that well format and that temperature window.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003e24-hour biological indicator incubator: block, power and order facts as listed\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDry-block biological indicator incubator, 24-hour read\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature zone\u003c\/td\u003e\n\u003ctd\u003e56–60 °C, held to ±0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWells\u003c\/td\u003e\n\u003ctd\u003e24, machined aluminium block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell diameter\u003c\/td\u003e\n\u003ctd\u003e8.8 mm, matched to standard spore ampoules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVial compatibility\u003c\/td\u003e\n\u003ctd\u003eSelf-contained ampoules, \u003cem\u003eG. stearothermophilus\u003c\/em\u003e ATCC 7953\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecords\u003c\/td\u003e\n\u003ctd\u003eLCD temperature display with USB data export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e100–240 V AC external adapter, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSold as\u003c\/td\u003e\n\u003ctd\u003eOne bench unit, not a case pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eCLI-INC-24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eTwo years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eIs one unit the right order, or does a clinic buy a case of them?\u003c\/h2\u003e\n\u003cp\u003eA case pack does not exist for this device: it leaves as a single bench unit with its external adapter, so the SKU on the invoice is one machine and a busy office usually stops there. The reprocessing bench is where incubation happens, not each operatory, so four chairs sharing one sterilizer need one block and a second one only when a second sterilizer sits in another suite. Buying two units for redundancy sounds prudent until both sit half full and neither is ever the one an auditor asks to see.\u003c\/p\u003e\n\u003ch2\u003eHow many wells does a three-sterilizer office fill in a working week?\u003c\/h2\u003e\n\u003cp\u003eCount one well per sterilizer per day it is run. Three sterilizers across a five-day week is fifteen wells, a six-day week is eighteen, and a 24-well block still holds six seats for the re-test that follows a failed indicator and for the extra run after a holiday closure. That spare room is the practical reason the block is sized above a single day's load: a failure on Friday afternoon cannot wait for Monday if the block is already full. Offices that want a same-shift answer pair this block with a rapid reader, or step down to a \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-1-hour-rapid-readout-50-pack\"\u003eone-hour readout indicator\u003c\/a\u003e and read it in the reader at the bench.\u003c\/p\u003e\n\u003cp\u003ePrint the daily record sheet from the \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003espore log and record centre\u003c\/a\u003e, work out how many indicators a week of clinics consumes with the \u003ca href=\"\/en-us\/pages\/clinic-supply-planner\"\u003esterilizer run planner\u003c\/a\u003e, and put a procedure question to the \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003esterilization compliance desk\u003c\/a\u003e. Districts consolidating several sites order through the \u003ca href=\"\/en-us\/pages\/wholesale\"\u003eclinic ordering desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/how-to-choose-biological-indicator-incubator-canadian-clinic\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/clinicare_incubator_main_v2.png?v=1788450549\" alt=\"CliniEco 24-Hour Biological Indicator Incubator — Precision Dry-Block, 24 Wells\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eDistributed in Canada by CliniEco Medical, Toronto, under MDEL #35334.\u003c\/p\u003e\n\u003cdiv class=\"clini-prod\"\u003e \u003cdiv class=\"clini-prod-hero\"\u003e \u003ch2 class=\"clini-prod-title\"\u003eCliniEco 24-Hour Biological Indicator Incubator\u003c\/h2\u003e \u003cp\u003eDaily sterilization monitoring made simple — audit-ready for Ontario dental clinics\u003c\/p\u003e\n\u003c\/div\u003e \u003cdiv class=\"clini-prod-section\"\u003e \u003ch2\u003eWhy Your Clinic Needs This\u003c\/h2\u003e \u003cp\u003eOntario regulations (RCDSO\/PHO) require \u003cstrong\u003eDAILY biological monitoring\u003c\/strong\u003e of sterilizers. Our 24-hour incubator gives you reliable, in-office spore testing with precision temperature control — at a fraction of the cost of major brands.\u003c\/p\u003e \u003cdiv class=\"clini-prod-note\"\u003e💡 \u003cstrong\u003ePrecision dry-block incubation\u003c\/strong\u003e — ±0.5 °C accuracy with LCD display, in a compact 24-well format.\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"clini-trust\"\u003e \u003ch3\u003e🛡️ Built to Clinical Standards — Inside This Incubator\u003c\/h3\u003e \u003cdiv class=\"clini-trust-grid\"\u003e \u003cdiv class=\"clini-trust-item\"\u003e \u003ch4\u003e🌡️ ±0.5°C Precision Heating\u003c\/h4\u003e \u003cp\u003ePID-controlled dry-block heating element with NTC temperature sensor holds a stable 56-60°C incubation zone — critical for accurate BI growth and reliable results.\u003c\/p\u003e\n\u003c\/div\u003e \u003cdiv class=\"clini-trust-item\"\u003e \u003ch4\u003e🔧 Machined Aluminum Block\u003c\/h4\u003e \u003cp\u003eCNC-machined aluminum heating block with 24 precision wells (φ8.8 mm, matched to standard BI vial outer diameter), ensuring consistent thermal contact across every vial.\u003c\/p\u003e\n\u003c\/div\u003e \u003cdiv class=\"clini-trust-item\"\u003e \u003ch4\u003e⚙️ Industrial-Grade Control\u003c\/h4\u003e \u003cp\u003eMicrocontroller-based temperature control with real-time LCD display and USB data export — audit-ready records for RCDSO inspections.\u003c\/p\u003e\n\u003c\/div\u003e \u003cdiv class=\"clini-trust-item\"\u003e \u003ch4\u003e🔌 Robust Build \u0026amp; Support\u003c\/h4\u003e \u003cp\u003e100–240 V AC external adapter (50\/60 Hz), 2-year warranty, Toronto-based support with Canadian distribution under MDEL #35334.\u003c\/p\u003e\n\u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"clini-cert-row\"\u003e \u003cspan class=\"clini-cert-chip\"\u003e✅ 2-Year Warranty\u003c\/span\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"clini-prod-section\"\u003e \u003ch2\u003eSpecifications\u003c\/h2\u003e \u003ctable class=\"clini-prod-table\"\u003e \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDry-block biological indicator incubator (24h)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e56-60°C (±0.5°C precision)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eWells\u003c\/td\u003e\n\u003ctd\u003e24 wells (φ8.8 mm, matched to standard BI vial diameter)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eSelf-contained BI ampoules (G. stearothermophilus ATCC 7953)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD temperature display\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eData\u003c\/td\u003e\n\u003ctd\u003eUSB data export (optional record software)\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e100-240V AC 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2-year warranty\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"clini-prod-section\"\u003e \u003ch2\u003eWhy CliniEco\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003ePrecision:\u003c\/strong\u003e ±0.5 °C dry-block control held across all 24 wells\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eNo lock-in:\u003c\/strong\u003e works with any standard 56-60 °C BI ampoules\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eAudit-ready:\u003c\/strong\u003e pair with our free printable record sheets\u003c\/li\u003e  \u003cli\u003e\n\u003cstrong\u003eMade for Canada:\u003c\/strong\u003e 110V\/60Hz, EN\/FR labeling, Toronto-based support\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv class=\"clini-prod-section\" style=\"text-align:center\"\u003e \u003ch2\u003eSold on its own\u003c\/h2\u003e \u003cp\u003eOur 24-hour indicators start at $2.80 each in the 25-pack, and the price per strip drops as the pack size goes up.\u003c\/p\u003e \u003ca class=\"clini-prod-cta\" href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003eShop the 25-pack\u003c\/a\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eBiological indicator packs priced for this block\u003c\/h2\u003e\n\u003cp\u003eThe block holds twenty-four wells of 8.8 mm, so the 24-hour self-contained ampoule is the format it was machined for; the fluorescence formats below are listed because they need the same bench space but a different readout device. Prices are per pack in CAD, and the cost per test is the pack price divided by the number of tests inside it — no quote required (MDEL #35334).\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePack \/ format\u003c\/th\u003e\n\u003cth\u003ePrice (CAD)\u003c\/th\u003e\n\u003cth\u003eCost per test\u003c\/th\u003e\n\u003cth\u003eOrder\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e24-hour self-contained BI\u003c\/td\u003e\n\u003ctd\u003e25-pack\u003c\/td\u003e\n\u003ctd\u003e$69.99\u003c\/td\u003e\n\u003ctd\u003e$2.80\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003e24-hour self-contained biological indicator, 25-pack\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24-hour self-contained BI\u003c\/td\u003e\n\u003ctd\u003e50-pack\u003c\/td\u003e\n\u003ctd\u003e$109.99\u003c\/td\u003e\n\u003ctd\u003e$2.20\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-50-pack\"\u003e24-hour self-contained biological indicator, 50-pack\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24-hour self-contained BI\u003c\/td\u003e\n\u003ctd\u003e100-pack\u003c\/td\u003e\n\u003ctd\u003e$189.00\u003c\/td\u003e\n\u003ctd\u003e$1.89\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-100-pack\"\u003e24-hour self-contained biological indicator, 100-pack\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCliniEco 24-hour dry-block incubator\u003c\/td\u003e\n\u003ctd\u003e24 wells\u003c\/td\u003e\n\u003ctd\u003e$379.00\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-24-hour-biological-indicator-incubator-precision-dry-block-15-wells\"\u003eCliniEco 24-hour biological indicator incubator, 24 wells\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-hour fluorescence BI (needs the reader)\u003c\/td\u003e\n\u003ctd\u003e50-pack\u003c\/td\u003e\n\u003ctd\u003e$269.99\u003c\/td\u003e\n\u003ctd\u003e$5.40\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-1-hour-rapid-readout-50-pack\"\u003e1-hour fluorescence biological indicators, 50-pack\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eWhich formats fit this block:\u003c\/strong\u003e the 24-hour self-contained ampoule drops straight into the 8.8 mm well and incubates at 56–60 °C; a fluorescence indicator of 1 hour, 3 hours or 20 minutes has to be read in the 4-well fluorescence reader instead, so it belongs on the same bench but not in this block. A cap wider than the well will not enter it, and an undersized tube sits loose with an air gap, which is the usual reason one vial in a batch reads late.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStock and shipping:\u003c\/strong\u003e orders ship from Ontario, Canada, and the exact dispatch date is confirmed with you before the order is released — we do not quote a delivery date at checkout. Every indicator pack carries its lot number, so the entry in your monitoring log can be traced back to the batch.\u003c\/p\u003e\n\u003cdiv class=\"product-guides-block\"\u003e\n\u003ch3\u003eRelated Guides\u003c\/h3\u003e\n\u003cp\u003eLearn how to choose and use this product correctly:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/sterility-assurance-level-sal-explained-what-10-6-means-for-sterilization\"\u003eSterility Assurance Level (SAL) Explained: What 10-6 Means for Sterilization\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/what-to-do-when-a-biological-indicator-test-fails\"\u003eBiological Indicator Failure: Recall, Root Cause, and Re-Test Protocol\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/class-4-vs-class-5-vs-class-6-sterilization-indicators-what-each-level-means\"\u003eClass 4 vs 5 vs 6 Sterilization Indicators: Which Do You Need?\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/how-often-should-you-run-a-spore-test-sterilizer-monitoring-schedules\"\u003eHow Often Should You Run a Spore Test? Sterilizer Monitoring Schedules\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e \u003cstyle\u003e.clini-prod { max-width:760px; margin:0 auto; font-family:-apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, sans-serif; color:#111827; }.clini-prod-hero { background:linear-gradient(135deg,#206270 0%,#2A5C8A 100%); border-radius:14px; padding:32px 28px; color:#fff; text-align:center; margin-bottom:24px; }.clini-prod-hero.clini-prod-title { font-size:26px; margin:0 0 8px; }.clini-prod-hero p { font-size:15px; opacity:.92; margin:4px 0; }.clini-prod-section { margin:24px 0; }.clini-prod-section h2 { font-size:18px; color:#206270; border-bottom:2px solid #E5E7EB; padding-bottom:8px; }.clini-prod-table { width:100%; border-collapse:collapse; margin:12px 0; }.clini-prod-table td { border:1px solid #E5E7EB; padding:10px 12px; font-size:14px; }.clini-prod-table td:first-child { background:#F9FAFB; font-weight:600; width:35%; }.clini-prod-cta { background:#206270; color:#fff; display:inline-block; padding:14px 32px; border-radius:8px; text-decoration:none; font-weight:600; font-size:16px; }.clini-prod-note { background:#FFF7ED; border:1px solid #FDBA74; border-radius:8px; padding:12px 16px; font-size:13px; color:#7C2D12; margin:16px 0; }.clini-trust { background:#f8fafc; border:1px solid #d1d5db; border-radius:12px; padding:20px; margin:20px 0; }.clini-trust h3 { margin:0 0 12px; font-size:1.1rem; color:#123a2f; }.clini-trust-grid { display:grid; grid-template-columns:1fr 1fr; gap:12px; }.clini-trust-item { background:#fff; border:1px solid #e5e7eb; border-radius:8px; padding:12px; }.clini-trust-item h4 { margin:0 0 4px; font-size:0.95rem; color:#206270; }.clini-trust-item p { margin:0; font-size:13px; color:#4b5563; line-height:1.5; }.clini-cert-row { display:flex; flex-wrap:wrap; gap:8px; margin-top:12px; }.clini-cert-chip { background:#e8f1f5; color:#123a2f; border-radius:20px; padding:5px 14px; font-size:12.5px; font-weight:600; }\n\u003c\/style\u003e\n\n\u003c!-- bi-family-crosslink v1 --\u003e\n\n\u003cp\u003e\u003cstrong\u003eHave a question about your own facility?\u003c\/strong\u003e Send it in and you will get a written answer specific to your setup, with the regulation or standard it is based on cited. \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003eAsk your compliance question\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eRelated tests in this BI line\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/dlab-hb120-s-led-digital-dry-bath-incubator\"\u003eDLAB HB105-S1 Dry-Bath Incubator with Lid — 20 wells, $599.00\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-clinic-starter-bundle-gloves-spore-testing-sterilization-packaging\"\u003eClinic Starter Bundle — Gloves, Spore Testing \u0026amp; Sterilization Packaging\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-1-hour-rapid-readout-50-pack\"\u003eCliniEco Medical Biological Indicator — 1-Hour Rapid Readout, Fluorescence, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-20-minute-rapid-readout-50-pack\"\u003eCliniEco Medical Biological Indicator — 20-Minute Rapid Readout, Fluorescence, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-100-pack\"\u003eCliniEco Medical Biological Indicator — 24-Hour Self-Contained, 100-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003eCliniEco Medical Biological Indicator — 24-Hour Self-Contained, 25-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-50-pack\"\u003eCliniEco Medical Biological Indicator — 24-Hour Self-Contained, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-3-hour-rapid-readout-fluorescence-50-pack\"\u003eCliniEco Medical Biological Indicator — 3-Hour Rapid Readout, Fluorescence, 50-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-bowie-dick-test-pack-iso-11140-5-type-2-daily-vacuum-check-6-pack\"\u003eCliniEco Medical Bowie-Dick Test Pack — ISO 11140-5 Type 2, Daily Vacuum Check, 6-Pack\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-rapid-reader-4-well-fluorescence-biological-indicator-reader\"\u003eCliniEco Rapid Reader — 4-Well Fluorescence Biological Indicator Reader\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/24-hour-self-contained-biological-indicator-pack-sizes-incubation-record\"\u003e24-Hour Self-Contained Biological Indicators: Pack Sizes, Incubation and the Record\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/how-often-us-vs-canadian-clinics-sterilizer-testing-incubator-guide\"\u003eHow Often Must US vs Canadian Clinics Run Sterilizer Testing? 24-Hour Biological Indicator Incubator Ordering \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/which-standards-medical-biological-indicator-us-vs-canada\"\u003eWhich Standards Apply to Medical Biological Indicator in the US vs Canada? Sizes and Sourcing\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/which-standards-hb105-s2-dry-bath-incubator-us-vs-canada\"\u003eWhich Standards Apply to HB105-S1 Dry Bath Incubator with Lid in the US vs Canada? Sizes and Sourcing\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":48967661715678,"sku":"CLI-INC-24","price":379.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/INCUBATOR-24H-HERO-logo-20261110_4d747eac-4cbf-43ea-afea-8cc34776c101_c8ab695d-16a7-49b0-abbe-bec1f7e07064.jpg?v=1794342630"},{"product_id":"clinieco-benchtop-autoclave-class-b-coming-soon","title":"Benchtop Autoclave (Class B Steam Sterilizer) — Coming Soon","description":"\u003cdiv class=\"product-description\"\u003e\n\u003ch2\u003eWhat does a Class B pre-vacuum cycle change for a clinic?\u003c\/h2\u003e\n\u003cp\u003eA gravity cycle pushes steam in and lets air out; a pre-vacuum cycle pulls air out first, which is what allows wrapped, hollow and porous loads to be sterilised reliably. That is why Class B benchtop units are the format dental clinics, veterinary practices, med-spas and tattoo studios look at: the loads those rooms actually run are wrapped and hollow, not open instruments on a tray.\u003c\/p\u003e\n\u003ch2\u003eWhat has to be true before a benchtop unit goes into service?\u003c\/h2\u003e\n\u003cp\u003eThree things, and none of them are optional: the unit has to be validated for the load types the clinic runs, the monitoring schedule has to be in place from the first cycle, and the records have to survive an inspection. In Ontario, the dental regulator's infection-control standard sets the expectation for sterilisation monitoring; the practical version is a biological indicator on every day the unit runs, plus chemical indicators in every pack and a record of both.\u003c\/p\u003e\n\u003ch2\u003eWhere does this unit sit in that programme?\u003c\/h2\u003e\n\u003cp\u003eIt does not publish chamber volume, cycle times or the licensing position, and a clinic should not plan an equipment replacement around a date that has not been confirmed. What can be done now is the part that takes longer than the purchase: the monitoring routine and the record keeping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFormat:\u003c\/strong\u003e Benchtop steam steriliser, pre-vacuum Class B cycle\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLoad types:\u003c\/strong\u003e Wrapped, hollow and porous loads\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntended settings:\u003c\/strong\u003e Dental clinics, veterinary practices, med-spas, tattoo studios\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMonitoring expectation:\u003c\/strong\u003e Biological indicator each day the unit runs, chemical indicator in every pack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDistribution:\u003c\/strong\u003e CliniEco Medical — MDEL #35334\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFormat:\u003c\/strong\u003e Benchtop steam steriliser, pre-vacuum Class B cycle\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLoad types:\u003c\/strong\u003e Wrapped, hollow and porous loads\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntended settings:\u003c\/strong\u003e Dental clinics, veterinary practices, med-spas, tattoo studios\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMonitoring expectation:\u003c\/strong\u003e Biological indicator each day the unit runs, chemical indicator in every pack\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDistribution:\u003c\/strong\u003e CliniEco Medical — MDEL #35334\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eBenchtop steam steriliser — planned specification as listed\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003ePlanned \/ stated\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eBenchtop steam steriliser, pre-vacuum Class B cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad types\u003c\/td\u003e\n\u003ctd\u003eWrapped, hollow and porous loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended settings\u003c\/td\u003e\n\u003ctd\u003eDental clinics, veterinary practices, med-spas, tattoo studios\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChamber volume\u003c\/td\u003e\n\u003ctd\u003eNot stated on the listing — confirmed before release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCycle times\u003c\/td\u003e\n\u003ctd\u003eNot stated on the listing — confirmed before release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring expectation\u003c\/td\u003e\n\u003ctd\u003eBiological indicator each day the unit runs, chemical indicator in every pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003ctd\u003eCliniEco Medical — MDEL #35334\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhat does the monitoring programme need on the shelf?\u003c\/h2\u003e\n\u003cp\u003eA \u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-50-pack\"\u003e24-hour self-contained biological indicator, fifty per pack\u003c\/a\u003e covers daily spore testing, and a \u003ca href=\"\/en-us\/products\/clinieco-medical-bowie-dick-test-pack-iso-11140-5-type-2-daily-vacuum-check-6-pack\"\u003eBowie-Dick test pack to ISO 11140-5 Type 2\u003c\/a\u003e is the daily vacuum check a pre-vacuum unit needs before the first load. For packaging, the \u003ca href=\"\/en-us\/products\/clinieco-sterilization-pouch-class-4-self-sealing-dual-indicator-200-per-box\"\u003eClass 4 self-sealing pouch with dual indicators, two hundred per box\u003c\/a\u003e is the consumable that keeps the routine running. Log sheets print from the \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003ecompliance log centre\u003c\/a\u003e and can be generated with the sterilization log generator on that page; clinic quantities are quoted at \u003ca href=\"\/en-us\/pages\/wholesale\"\u003ethe clinic ordering desk\u003c\/a\u003e, and the monitoring question itself can be booked with \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003ethe compliance desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eImported and distributed in Canada by CliniEco Medical — MDEL #35334.\u003c\/p\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eCliniEco Medical is preparing to introduce a \u003cstrong\u003ebenchtop Class B steam sterilizer (autoclave)\u003c\/strong\u003e for Canadian dental clinics, veterinary practices, med-spas, and tattoo studios. Class B pre-vacuum technology delivers validated sterilization for wrapped, hollow, and porous loads — the same standard trusted by modern clinics.\u003c\/p\u003e\n\u003ch2\u003eWhy Wait for Our Autoclave?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance-first\u003c\/strong\u003e — sourced from manufacturers holding Canadian Medical Device Licence (Class II) and FDA 510(k) clearance; distributed by CliniEco Medical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne-stop sterilization room\u003c\/strong\u003e — pairs with our sterilization pouches, rolls, Class 4\/5 indicators, biological indicators (BI) and monitoring equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal support\u003c\/strong\u003e — Toronto warehouse, Canadian-based distributor, full documentation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen consumables ecosystem\u003c\/strong\u003e — works with standard sterilization pouches\/tape\/BI on the market (no lock-in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAvailability\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWe are currently completing model selection and sample validation. Expected retail range CAD $3,500–$4,500 depending on model (final pricing TBD at launch).\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo be notified at launch or to discuss bulk\/group pricing for multi-chair clinics, contact us at \u003ca href=\"mailto:alina@clinieco.ca\"\u003ealina@clinieco.ca\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- sterilization-system-links --\u003e\n\u003cdiv style=\"max-width:820px;margin:28px auto 8px;padding:16px 20px;border:1px solid #e2e8f0;border-radius:12px;background:#f8fafc\"\u003e\n\u003cp style=\"margin:0 0 10px;font-weight:700;color:#206270;font-size:15px\"\u003ePart of the same sterilization system\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px;line-height:1.9;font-size:15px;color:#334155\"\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003e24-Hour Biological Indicators — 25-Pack\u003c\/a\u003e — $69.99\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-us\/products\/clinieco-24-hour-biological-indicator-incubator-precision-dry-block-15-wells\"\u003e24-Hour BI Incubator — Dry-Block\u003c\/a\u003e — $379.00\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-us\/products\/clinieco-sterilization-pouch-class-4-self-sealing-dual-indicator-200-per-box\"\u003eSterilization Pouches — Class 4, Assorted 200-Pack\u003c\/a\u003e — $11.99 (case of 10 — $95.92)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/which-benchtop-autoclave-class-b-british-columbia-spd\"\u003eWhich Benchtop Autoclave (Class B Steam Sterilizer) Do Hospital Sterile Processing Departments in British Colu\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/iso-15882-chemical-indicator-selection-storage-reading\"\u003eISO 15882 in Practice: Selecting, Storing and Reading Chemical Indicators\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":48987217723614,"sku":"CLI-AUTOCLAVE-CB-COMING","price":3999.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/01_main_white_clean_c8ce08af-0c80-47fc-a177-7bb5de0f203a.jpg?v=1791271772"},{"product_id":"clinieco-ultrasonic-cleaner-6l-cs6-2-benchtop-dual-frequency","title":"Ultrasonic Dental Cleaner CS6.2 — 6 L Benchtop, Dual-Frequency 32\/48kHz, for Instrument Cassettes | CliniEco Medical","description":"\u003ch3\u003eThe cleaner that takes a full instrument cassette\u003c\/h3\u003e\n\u003cp\u003eMost benchtop ultrasonic cleaners sold online are built for jewellery, glasses and dentures. They are small, they are cheap, and they cannot take a standard dental instrument cassette — which means someone at your practice ends up running them in loose batches, twice.\u003c\/p\u003e\n\u003c!-- ce-glance:CS6.2 --\u003e\n\u003cdiv class=\"ce-glance\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003e6 L\u003c\/strong\u003e stainless steel tank · dual frequency 32 \/ 48 kHz · 320 W · AC 100–120 V \/ 60 Hz · cETL certified by Intertek to CSA C22.2 No. 68 and UL 73.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003eA full dental instrument cassette fits in one cycle, lid closed, instruments still in the rack. All sizes, 4 L to 20 L: \u003ca href=\"\/en-us\/collections\/ultrasonic-cleaners\"\u003eultrasonic cleaners and enzyme solution for dental practices in Canada\u003c\/a\u003e.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHow to order\u003c\/th\u003e\n\u003ctd\u003eShips from Toronto, Ontario. Order a single unit online, or by purchase order through \u003ca href=\"\/en-us\/pages\/wholesale\"\u003ewholesale and institutional ordering\u003c\/a\u003e. Current lead time for this model is confirmed before dispatch.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp\u003eIf you are looking for an ultrasonic dental cleaner that takes a full cassette, the CS6.2 is the 6 L class answer: it is a dental ultrasonic cleaner built for dental instrument reprocessing, not for jewellery, glasses or retainers. It is also the ultrasonic cleaner for dental instruments that clinics ask for when their old unit was sized for a countertop, not for a cassette.\u003c\/p\u003e\n\u003cp\u003eThe CS6.2 is a \u003cstrong\u003e6 L class\u003c\/strong\u003e unit. That is the size at which a full cassette fits in one cycle, which is the whole point of having a cleaner on the bench.\u003c\/p\u003e\n\u003cp\u003ecETL certified by Intertek to \u003cstrong\u003eCSA C22.2 No. 68\u003c\/strong\u003e and \u003cstrong\u003eUL 73\u003c\/strong\u003e. CliniEco Medical is a Canadian importer based in Toronto — ask us for the current lead time.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/where-to-buy-dental-ultrasonic-cleaner-dental-clinics-nova-scotia\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/599bf33f4da20fb38d1771bb70a76d19.png?v=1792815581\" alt=\"CliniEco Dental Ultrasonic Cleaner — 6 L Benchtop, CS6.2 Dual-Frequency 32\/48kHz\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eAlready running an ultrasonic bath and reordering solution?\u003c\/h3\u003e\n\u003cp\u003eIf you are buying cleaning solution by the jug, there is already a tank on your bench. The question is no longer whether to run an ultrasonic bath — it is whether that tank is the right size and the right frequency for the load going into it.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eA 6 L class tank.\u003c\/strong\u003e A full instrument cassette fits in a single cycle, so the same load does not get run twice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual frequency, 32 kHz and 48 kHz.\u003c\/strong\u003e 32 kHz for heavier soils, 48 kHz for fine crevices — one unit covers the whole load instead of making you pick one.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat, timer and basket included.\u003c\/strong\u003e Ceramic heaters take the solution to 40–60 °C, the digital timer runs to 30 minutes with a 120 s degas cycle, and the SB01 stainless basket ships with the unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSolution is a running cost that keeps coming back. The unit is a one-time purchase that decides how well that solution works — and if the tank on your bench is the wrong size or the wrong frequency for your cassette, replacing it is the more practical path than working around it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdd the CS6.2 to your cart above\u003c\/strong\u003e, or send us your cassette count and we will tell you whether 6 L is the right size for your room.\u003c\/p\u003e\n\u003ch2\u003eWhat does the CS6.2 cost, and what comes with the unit at that price?\u003c\/h2\u003e\n\u003cp\u003eThe cleaner is a single SKU at $699.00, basket included. That basket is part SB01 and can be re-ordered on its own once it wears, so a replacement does not mean a new machine. At the listed figure you get the 6 L tank, the dual-frequency generator, two ceramic heaters and the digital timer; nothing in the table below is an add-on. Consumables sit outside that price: the \u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003eenzyme cleaning solution\u003c\/a\u003e is what goes in the tank, sold by the 4 L container.\u003c\/p\u003e\n\u003ch2\u003eDoes this unit log cleaning cycles?\u003c\/h2\u003e\n\u003cp\u003eNo. The CS6.2 has no internal data logger and cannot export cycle data to a USB drive or a CSV file. If your reprocessing protocol requires machine-generated cycle records, choose a unit built for that purpose — this model is not one.\u003c\/p\u003e\n\u003cp\u003eWhat the CS6.2 gives you instead is everything needed to keep a defensible manual record: a front-panel timer that counts the cycle, a temperature set-point you can read and write down, and a drain valve so the solution-change date is unambiguous. Under CSA Z314:23 the documentation obligation sits inside your reprocessing quality system rather than inside the appliance, so a signed paper log is not a lesser record — it is the record the standard asks for.\u003c\/p\u003e\n\u003cp\u003eFive fields per cycle is enough: date, operator, temperature set-point, cycle length, and the date the solution was last changed. One line, end of shift.\u003c\/p\u003e\n\u003ch2\u003eWill a 6 L tank take a full instrument cassette?\u003c\/h2\u003e\n\u003cp\u003eYes, and that is the size break the CS6.2 is built around. Tank dimensions are 31.1 × 17.2 × 11.6 cm, the footprint a standard dental cassette needs; under 3 L you are either unpacking instruments or running two cycles. Above 6 L the units are bought for several cassettes and longer runs, and they cost two to three times more, which is why a single-surgery practice rarely needs one. Instruments go in the basket or the cassette — never piled on the tank floor, because metal resting on metal blocks the cavitation underneath.\u003c\/p\u003e\n\u003ch2\u003eDoes a benchtop ultrasonic cleaner sterilise instruments, or only clean them?\u003c\/h2\u003e\n\u003cp\u003eIt cleans, and it does not sterilise. An ultrasonic cycle lifts soil — cement residue, polishing paste, dried blood from hinges — and that step comes before pouching and the autoclave, never in place of it. The 32 kHz setting drives larger bubbles for heavier soil, 48 kHz drives smaller ones into lumens and threaded joints, and the 120-second degas cycle at the start is what keeps the first load of the day behaving like the fourth. What the unit does carry is electrical certification: cETL by Intertek to CSA C22.2 No. 68 and UL 73.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCS6.2 6 L benchtop ultrasonic cleaner — tank, frequencies, certification and price\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eField\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTank capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 L class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTank dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31.1 × 17.2 × 11.6 cm, SUS304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual — 32 kHz and 48 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 W total; two transducers at 80 W or less each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating and timer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo ceramic heaters, 40–60 °C selectable; digital timer with 120 s degas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ecETL by Intertek to CSA C22.2 No. 68 and UL 73\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC 100–120 V \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCLI-ULTRA-CLEAN-62 — $699.00, basket SB01 included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCleaning records for the reprocessing room print from the \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003ecompliance log centre\u003c\/a\u003e, and the log generator on that page fills the date row for each station; fitting a new unit into an existing workflow is the kind of question the \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003esterilization compliance consultation\u003c\/a\u003e answers. This cleaner is imported into Canada by CliniEco Medical, MDEL #35334.\u003c\/p\u003e\n\u003ch3\u003eWhy the 6 L class is the one that matters\u003c\/h3\u003e\n\u003cp\u003eInstrument cassettes are the standard way dental practices sterilise. If your cleaner cannot take the cassette, you are either unpacking instruments to clean them or running two cycles, and both cost you time every single day.\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTank capacity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eWhat fits\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eWho it suits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eUnder 3 L\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eHandpieces, retainers, loupes\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eFront desk, ortho, solo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003e6 L (this unit)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eA full instrument cassette\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eGeneral practice, hygiene\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e8 L and up\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eMultiple cassettes, larger runs\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eHigh-volume, labs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis is one of the two sizes Canadian dental practices buy most. The larger units in this range cost two to three times more, which is why most single-surgery practices stay in this class.\u003c\/p\u003e\n\u003ch3\u003eCertification you can actually check\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eElectrical certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\n\u003cstrong\u003ecETL (Intertek)\u003c\/strong\u003e, to \u003cstrong\u003eCSA C22.2 No. 68\u003c\/strong\u003e and \u003cstrong\u003eUL 73\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\n\u003cstrong\u003eAC 100–120 V \/ 60 Hz\u003c\/strong\u003e — North American supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eProduct code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\n\u003cstrong\u003eCS6.2\u003c\/strong\u003e — the manufacturer's model number, printed on the unit nameplate and on the carton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eImporter of record\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\n\u003cstrong\u003eCliniEco Medical\u003c\/strong\u003e — Health Canada \u003cstrong\u003eMDEL #35334\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eManufactured by an OEM whose units are already in service with major North American dental distributors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eMany low-cost units sold online carry FCC, CE and RoHS only. Those are not electrical safety certifications, and a unit without an NRTL mark should not be installed in a commercial setting under the Ontario Electrical Safety Code. If you are being asked to sign off on a clinic, that distinction is the one that matters.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px\"\u003eTank capacity\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px\"\u003e\n\u003cstrong\u003e6 L\u003c\/strong\u003e (6 L class)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTank dimensions\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003e31.1 × 17.2 × 11.6 cm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eCleaning frequency\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eDual frequency — 32 kHz \/ 48 kHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTransducers\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e2 × industrial-grade, ≤ 80 W each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eTotal power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003e320 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eHeating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003e2 × ceramic heaters, 40–60 °C (selectable)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eDegassing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\n\u003cstrong\u003e120 s cycle\u003c\/strong\u003e (removes dissolved air that blunts cavitation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTimer\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eDigital, with heater control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTank \u0026amp; basket\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eSUS304 stainless steel, with a removable basket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eHousing (external shell)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eAluminium alloy + ABS — external only; never immersed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eUnit weight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eapprox. \u003cstrong\u003e9.2 kg\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eAC 100–120 V \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eCertification\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003ecETL (Intertek) · CSA C22.2 No. 68 · UL 73\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eElectrical safety report\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eIntertek \u003cstrong\u003e220112140GZU-001\u003c\/strong\u003e — applicable to model CS6.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eBasket part code\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eStainless steel basket \u003cstrong\u003eSB01\u003c\/strong\u003e (replaceable \/ re-orderable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhat the dual frequency actually does for you\u003c\/h3\u003e\n\u003cp\u003eCavitation behaves differently at different frequencies, and this is not a marketing line — it is physics.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e32 kHz\u003c\/strong\u003e — larger, more energetic bubbles. Better at lifting heavier soils: cement residue, polishing paste, dried blood on hinged instruments.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e48 kHz\u003c\/strong\u003e — smaller, denser bubbles. Gentler, and it reaches into fine crevices, lumens and threaded joints without the erosion risk that aggressive low-frequency cavitation can cause on plated instruments.\u003c\/p\u003e\n\u003cp\u003eRunning both means one machine covers the whole load rather than forcing you to choose between \"heavy soil\" and \"delicate instrument\".\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDegassing matters more than people expect.\u003c\/strong\u003e Freshly filled tap water is saturated with dissolved air, and dissolved air absorbs the energy that should be forming cavitation bubbles. A 120-second degas cycle at the start is why the first load of the day performs like the fourth.\u003c\/p\u003e\n\u003ch3\u003eIn use\u003c\/h3\u003e\n\u003cp\u003e1. \u003cstrong\u003eFill\u003c\/strong\u003e to the marked level, add the cleaning solution, and run the \u003cstrong\u003e120 s degas\u003c\/strong\u003e cycle.\u003c\/p\u003e\n\u003cp\u003e2. \u003cstrong\u003eHeat\u003c\/strong\u003e to 40–60 °C (selectable). Warm solution measurably improves soil removal.\u003c\/p\u003e\n\u003cp\u003e3. \u003cstrong\u003eLoad\u003c\/strong\u003e — instruments in the basket or cassette, not piled on the tank floor. Cavitation is blocked by contact surfaces.\u003c\/p\u003e\n\u003cp\u003e4. \u003cstrong\u003eRun\u003c\/strong\u003e the cycle, then \u003cstrong\u003erinse\u003c\/strong\u003e and inspect before sterilisation.\u003c\/p\u003e\n\u003cp\u003e5. \u003cstrong\u003eEmpty and dry\u003c\/strong\u003e the tank. Leaving solution in overnight is what shortens the life of the transducer plate.\u003c\/p\u003e\n\u003ch3\u003eConsumables that go with it\u003c\/h3\u003e\n\u003cp\u003eUltrasonic cleaning is a consumable line, not a one-off purchase.\u003c\/p\u003e\n\u003cp\u003e• \u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003e\u003cstrong\u003eEnzymatic ultrasonic cleaning solution\u003c\/strong\u003e\u003c\/a\u003e — 4 L concentrate. The right chemistry does more work than a longer cycle.\u003c\/p\u003e\n\u003cp\u003e• \u003ca href=\"\/en-us\/collections\/dental-sterilization-essentials\"\u003e\u003cstrong\u003eSterilisation pouches, indicator tape and biological indicators\u003c\/strong\u003e\u003c\/a\u003e — for the steps after the cleaner.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e(We also supply the consumables above. Bundling them with the unit is how most practices run it.)\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eOrdering\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e$699.00.\u003c\/strong\u003e CliniEco Medical, Toronto, Ontario. Ask us for the current lead time before you order.\u003c\/p\u003e\n\u003cp\u003eCliniEco Medical is the importer of record: \u003cstrong\u003eEcology Source New Energy Technology Co., LTD. o\/a CliniEco Medical\u003c\/strong\u003e, Health Canada \u003cstrong\u003eMDEL #35334\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eQuestions about whether this is the right size for your practice — tell us how many cassettes you run per day and we will tell you straight, even if the answer is that you do not need this one.\u003c\/p\u003e\u003ch3\u003eStraight answers — including the things you may not want to hear\u003c\/h3\u003e\n\u003cp\u003eMost listings in this category skip the awkward parts. We do not, because the awkward parts are usually what decides the purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat this unit will not do.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIt will not clean aluminium or anodised instruments.\u003c\/strong\u003e No ultrasonic cleaner will. Anodised coatings and bare aluminium are attacked by the cavitation and by alkaline cleaning solutions. If you use aluminium trays or anodised cassettes, do not put them in any ultrasonic bath. This refers to what you place in the bath — the unit's own housing is aluminium alloy and sits outside the tank, so it is never immersed.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIt will not clean the inside of a narrow lumen on its own.\u003c\/strong\u003e Ultrasonic energy does not travel well down a small-diameter channel. Lumens and hinges need a brush as well — this is true of every unit at every price.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIt does not replace gross decontamination.\u003c\/strong\u003e Heavy debris should be wiped or rinsed off first. Solution life and cleaning performance both drop if you do not.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIt does not sterilise.\u003c\/strong\u003e This is a cleaner. Sterilisation is a separate step, in a separate machine.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat we can state plainly, that others often will not.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eThe tank holds 6 litres, and it measures 31.1 × 17.2 × 11.6 cm.\u003c\/strong\u003e Take a tape measure to your cassette before you buy. We would rather you check and not order than order and be disappointed.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eThe capacity figure is the real tank volume, not a model number.\u003c\/strong\u003e The model is CS6.2. The tank is 6 litres.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eThe electrical certification is cETL, to CSA C22.2 No. 68 and UL 73, issued by Intertek.\u003c\/strong\u003e We name the standard and the issuer so you can verify it. A product that says only \"FCC, CE and RoHS\" is telling you it holds no North American electrical safety certification — those three are emissions and materials marks, not safety marks, and a unit without an NRTL mark has no business being installed in a commercial setting.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eWe are the importer of record.\u003c\/strong\u003e Ecology Source New Energy Technology Co., LTD. o\/a CliniEco Medical, Health Canada MDEL #35334. That is on the label and on the paperwork, and it is who you hold responsible.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIt is not a no-name import.\u003c\/strong\u003e The unit is built by a manufacturer that also produces cleaners for established North American dental brands, and it ships with the manufacturer's own nameplate.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIf it is the wrong size for you, we will say so.\u003c\/strong\u003e Tell us how many cassettes you run per day and what instruments you put through them, and we will answer honestly — including when the honest answer is that you need a larger tank or a different machine.\u003c\/p\u003e\n\u003ch3\u003eSpecifications you can hold us to\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eTank capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\n\u003cstrong\u003e6 litres\u003c\/strong\u003e (model CS6.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTank dimensions\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e31.1 × 17.2 × 11.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eDual — 32 kHz \/ 48 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTransducers\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e2 × industrial grade, ≤ 80 W each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTotal power\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e320 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eHeating\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e2 × ceramic, 40–60 °C (selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eDegassing\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eAC 100–120 V \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eapprox. 9.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eCertification\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003ecETL (Intertek) · CSA C22.2 No. 68 · UL 73\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eImporter\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eCliniEco Medical — Health Canada MDEL #35334\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003eHave a question about your own facility?\u003c\/strong\u003e Send it in and you will get a written answer specific to your setup, with the regulation or standard it is based on cited. \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003eAsk your compliance question\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eChoosing the right option for your clinic\u003c\/h2\u003e\n\u003cp\u003eBefore you order, the decisions that actually change the result are tank size against instrument load, what 32\/48 kHz dual frequency changes, and how to document proof of clean. The full buyer's guide covers them step by step: \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/ultrasonic-cleaner-canadian-clinic-tank-frequency-proof-of-clean\"\u003eUltrasonic Cleaner for a Canadian Clinic: Tank, Frequency and Proof of Clean\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eRelated supplies for the same workflow\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003elow-foam multi-enzyme ultrasonic cleaning solution, 1 L \/ 5 L\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-constant-heat-pouch-sealer-200-c-12mm-seal-110v-dental-sterilization\"\u003econstant-heat pouch sealer, 200 °C, 12 mm seal\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-sterilization-pouch-class-4-self-sealing-dual-indicator-200-per-box\"\u003eClass 4 self-sealing sterilization pouches, 200 per box\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/clinieco-medical-ultrasonic-cleaning-solution-enzyme-4l-concentrate__pos01_noprice.png?v=1790001406\" alt=\"CliniEco multi-enzyme ultrasonic cleaning solution\" loading=\"lazy\" width=\"480\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eTwo units available in Toronto — ships immediately.\u003c\/strong\u003e Further units ship within one week of payment. Need it for a specific install date? Ask us and we will confirm before you pay.\u003c\/p\u003e\n\u003ch2\u003eHow many instrument cassettes can one 6 L tank get through in a day?\u003c\/h2\u003e\n\u003cp\u003eOne cassette per cycle, because that is what the tank is sized for: 31.1 × 17.2 × 11.6 cm takes a full dental instrument cassette laid flat, and the SB01 basket ships with the unit so the load comes out in one lift. The cycle is whatever you set on the digital timer, which runs to 30 minutes with a 120 s degas phase at the start, while the two ceramic heaters hold the solution in the 40–60 °C band.\u003c\/p\u003e\n\u003cp\u003eSo the daily arithmetic is cycles rather than cassettes. Four cycles in a morning and three in the afternoon is seven cassettes in a day, and the 6 L tank is the reason each of those cycles carries a whole cassette instead of a loose tray. Nothing here batches two cassettes at once: one cassette is what fills the tank usefully, and that is the honest limit of this size.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCycles you run in a day\u003c\/th\u003e\n\u003cth\u003eCassettes cleaned\u003c\/th\u003e\n\u003cth\u003eWhat that rhythm looks like\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2–3\u003c\/td\u003e\n\u003ctd\u003e2–3\u003c\/td\u003e\n\u003ctd\u003eA single surgery with a light morning list\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4–6\u003c\/td\u003e\n\u003ctd\u003e4–6\u003c\/td\u003e\n\u003ctd\u003eOne dentist and one hygienist with turnover between patients\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7–10\u003c\/td\u003e\n\u003ctd\u003e7–10\u003c\/td\u003e\n\u003ctd\u003eTwo chairs running, or a surgical list in the middle of the day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMore than 10\u003c\/td\u003e\n\u003ctd\u003e10+\u003c\/td\u003e\n\u003ctd\u003eNow the queue, not the tank, is the constraint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIn the last row the question is no longer whether 6 L is enough — the unit still cleans one cassette per cycle — but whether the room wants two cleaners on two benches so a second cassette can run while the first is being rinsed. Tell us the cassette count per day and we will say which of those two problems you actually have.\u003c\/p\u003e\n\n\u003ch2\u003eWhat has to be true of the room before the unit goes on the bench?\u003c\/h2\u003e\n\u003cp\u003eFour things, and all four are checkable before the carton is opened. The electrical side is the one that fails an inspection: the unit runs from a standard North American supply at AC 100–120 V \/ 60 Hz, with 320 W of total load across the transducers and heaters — roughly 2.7 A at 120 V, an ordinary branch circuit rather than anything special, but a unit without its cETL mark still should not be installed in a commercial setting.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eRequirement\u003c\/th\u003e\n\u003cth\u003eWhere the figure comes from\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceptacle\u003c\/td\u003e\n\u003ctd\u003eAC 100–120 V \/ 60 Hz, standard North American outlet\u003c\/td\u003e\n\u003ctd\u003eRating on the unit nameplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit load\u003c\/td\u003e\n\u003ctd\u003e320 W total, about 2.7 A at 120 V (derived from rated power)\u003c\/td\u003e\n\u003ctd\u003eTwo transducers ≤ 80 W each plus two ceramic heaters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety mark\u003c\/td\u003e\n\u003ctd\u003ecETL by Intertek, to CSA C22.2 No. 68 and UL 73\u003c\/td\u003e\n\u003ctd\u003eIntertek report 220112140GZU-001, applicable to model CS6.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBench space\u003c\/td\u003e\n\u003ctd\u003e31.1 × 17.2 cm of tank, plus room to lift the basket clear\u003c\/td\u003e\n\u003ctd\u003eTank dimensions and removable SB01 basket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain and dry-down\u003c\/td\u003e\n\u003ctd\u003eAbility to empty and dry the tank at the end of the day\u003c\/td\u003e\n\u003ctd\u003eSolution is changed daily and not left in the tank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe unit weighs approximately 9.2 kg empty, so it is a benchtop appliance one person can move, not a plumbed installation: no water connection, no drain line. You fill to the marked level and you empty it at the end of the day.\u003c\/p\u003e\n\n\u003ch2\u003eWhat belongs in an ultrasonic bath, and what must stay out?\u003c\/h2\u003e\n\u003cp\u003eThis is the part that decides whether the cleaner helps or quietly damages an instrument stock, and the answer is the same for every ultrasonic unit at every price. What changes with this machine is that 48 kHz gives a gentler cavitation field for plated and hinged work, so the question becomes which load goes in which cycle.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad\u003c\/th\u003e\n\u003cth\u003eIn the bath?\u003c\/th\u003e\n\u003cth\u003eWhat to watch\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStainless cassettes, loaded\u003c\/td\u003e\n\u003ctd\u003eYes — the load this tank is sized for\u003c\/td\u003e\n\u003ctd\u003eLay flat in the basket; never on the tank floor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHinged and plated instruments\u003c\/td\u003e\n\u003ctd\u003eYes, on the 48 kHz setting\u003c\/td\u003e\n\u003ctd\u003eKeep them from touching each other — contact surfaces block cavitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLumens and threaded joints\u003c\/td\u003e\n\u003ctd\u003eYes, plus a brush\u003c\/td\u003e\n\u003ctd\u003eUltrasonic energy does not travel down a narrow channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAluminium and anodised instruments or trays\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eCavitation and alkaline solutions attack both — true of any ultrasonic bath\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeavily soiled instruments from the chair\u003c\/td\u003e\n\u003ctd\u003eOnly after gross decontamination\u003c\/td\u003e\n\u003ctd\u003eHeavy debris shortens solution life and blunts the cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnything the instrument maker says not to immerse\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eThe instrument's reprocessing instructions come before any cleaner setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe housing of the CS6.2 is aluminium alloy and ABS, which is worth reading twice: the aluminium warning applies to what goes into the tank, not to the machine, whose shell sits outside the bath and is never immersed.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does the routine look like, day by day?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eWhen\u003c\/th\u003e\n\u003cth\u003eTask\u003c\/th\u003e\n\u003cth\u003eWhy it matters\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStart of day\u003c\/td\u003e\n\u003ctd\u003eFill, add solution, run the 120 s degas cycle\u003c\/td\u003e\n\u003ctd\u003eFresh tap water is saturated with dissolved air, which absorbs the energy that should form cavitation bubbles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBefore the first load\u003c\/td\u003e\n\u003ctd\u003eHeat the solution into the 40–60 °C band\u003c\/td\u003e\n\u003ctd\u003eWarm solution removes soil measurably better than cold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvery cycle\u003c\/td\u003e\n\u003ctd\u003eLoad in the basket or cassette, never piled on the floor\u003c\/td\u003e\n\u003ctd\u003eMetal on metal blocks cavitation underneath\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAfter every cycle\u003c\/td\u003e\n\u003ctd\u003eRinse and inspect before pouching\u003c\/td\u003e\n\u003ctd\u003eThe cleaner lifts soil; inspection is the check that the lift happened\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDaily, or sooner if soiled\u003c\/td\u003e\n\u003ctd\u003eChange the solution\u003c\/td\u003e\n\u003ctd\u003eThe most common reason practices report poor cleaning results\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnd of day\u003c\/td\u003e\n\u003ctd\u003eEmpty and dry the tank\u003c\/td\u003e\n\u003ctd\u003eSolution left overnight is what shortens the life of the transducer plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhen the basket wears\u003c\/td\u003e\n\u003ctd\u003eRe-order the SB01 basket\u003c\/td\u003e\n\u003ctd\u003eThe basket is a part number, not a consumable of the machine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTwo questions that come in before an order, answered here rather than saved for a call. The tank cannot take two cassettes at once: 31.1 × 17.2 cm of floor plus a 6 litre volume means one cassette fills it usefully, and two would sit against each other and against the walls — the exact contact pattern that ruins a cavitation field. And the heater is not something you stand over: it is controlled from the same panel as the timer, the band is selectable between 40 and 60 °C, and the unit holds the setting for the length of the cycle. What the unit does not do is log the cycle, so the temperature and time record for your reprocessing file is written on the room's own log.\u003c\/p\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":49011615105246,"sku":"CLI-ULTRA-CLEAN-62","price":699.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CS6.2-HERO-logo-20261110_645f5324-e5e4-4ce8-abd2-63c9038be8b5.jpg?v=1794342702"},{"product_id":"clinieco-constant-heat-pouch-sealer-200-c-12mm-seal-110v-dental-sterilization","title":"CliniEco Constant-Heat Pouch Sealer — 200°C, 12mm Seal, 110V (Dental Sterilization)","description":"\u003cp\u003e\u003cstrong\u003eConstant-Heat Pouch Sealer — Professional Sterilization Packaging\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CliniEco pouch sealer creates easily peelable, 12 mm-wide sealing seams for medical paper\/film sterilization pouches and rolls — the packaging format used to keep instruments sterile until the point of use.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstant temperature heating\u003c\/strong\u003e — holds a steady sealing temperature across the full seam for reproducible closure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelligent temperature and pressure compensation\u003c\/strong\u003e — maintains sealing performance during continuous use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne pre-heat, continuous operation\u003c\/strong\u003e — ready in 2–3 minutes, then run all day\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnti-roll and anti-scorch design\u003c\/strong\u003e for safe, clean results\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in cutter\u003c\/strong\u003e — trim pouches and rolls to any length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic beep\u003c\/strong\u003e when the seal cycle completes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicrocomputer control\u003c\/strong\u003e with overheat protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/how-often-should-sealers-be-tested-canada\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/9715fcd7ac9bd7aea2d9adb4f16108d2.png?v=1788977597\" alt=\"CliniEco Constant-Heat Pouch Sealer — 200°C, 12mm Seal, 110V (Dental Sterilization)\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eDo I need a pouch sealer, or are self-sealing pouches enough?\u003c\/h2\u003e\n\u003cp\u003eSelf-sealing pouches close on a pressure-sensitive strip: no machine, no pre-heat, one fixed size per pack, and nothing to warm up at seven in the morning. A sealer covers the two cases a pre-made pouch cannot — packs longer or wider than any stocked size, and rolls you cut to the length you actually need. If every pack you make already fits the pouch you buy, the sealer adds a step and removes none: fold, align, seal, wait for the beep.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does this sealer produce?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeal method\u003c\/td\u003e\n\u003ctd\u003eConstant heat (thermostatic head), no impulse wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeal width\u003c\/td\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax seal length\u003c\/td\u003e\n\u003ctd\u003e300 mm (12\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax roll width\u003c\/td\u003e\n\u003ctd\u003e300 mm, up to three rolls side by side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-heat time\u003c\/td\u003e\n\u003ctd\u003e2–3 minutes, then continuous operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e100 W, 110 V \/ 60 Hz (Canadian standard); 220 V also available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eOverheat cut-out, anti-scorch and anti-roll design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eStainless steel, IPX0 (indoor use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtras\u003c\/td\u003e\n\u003ctd\u003eBuilt-in cutter; audible beep at the end of each cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe 12 mm seam is the full width of the heating band, which is what lets the pack peel open at the point of use without the film tearing away from the paper. This is the 200 °C constant-heat model: the head holds one temperature for the whole run instead of spiking per impulse, so the tenth pack of the morning is sealed under the same conditions as the first.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does sealing cost per pack, against buying pouches?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ccaption\u003eCost per pack: the sterilization roll is a consumable sold as a case of 10 rolls; the sealer unit itself is priced separately in the first row\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003cth\u003eBasis\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstant-heat pouch sealer (one-time)\u003c\/td\u003e\n\u003ctd\u003e$349.00\u003c\/td\u003e\n\u003ctd\u003eThis page\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-sterilization-roll-pre-cut-sheets-50m-roll\"\u003eSterilization roll, 76 mm × 50 m (case of 10 rolls)\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e$105.00\u003c\/td\u003e\n\u003ctd\u003e105.00 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoll cost per metre\u003c\/td\u003e\n\u003ctd\u003eDivide the case amount by ten rolls and by the 50 m on each roll\u003c\/td\u003e\n\u003ctd\u003eAlways from the case amount on this page\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial for one 30 cm pack\u003c\/td\u003e\n\u003ctd\u003e0.30 m at the per-metre figure above\u003c\/td\u003e\n\u003ctd\u003eArithmetic, not a separate price\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe roll is tubing, so one cut length makes one pack: a 30 cm pack uses about 30 cm of roll, and the material carried in that length follows from the case amount shown on this page — the case holds ten rolls, and the per-metre figure comes from dividing the case amount by the total length on the case. A ready-made pouch of a comparable size runs $0.04 to $0.12 per pack (checked Oct 2026). That is the honest comparison — rolls win when the pack is a size nobody stocks, not when it is a size you can simply buy. The 76 mm roll we stock suits packs up to about three inches wide; the sealer itself takes rolls up to 300 mm.\u003c\/p\u003e\n\n\u003ch2\u003eWhich packs should be sealed rather than self-sealed?\u003c\/h2\u003e\n\u003cp\u003eLong or oversized loads are the usual reason to own a sealer: orthodontic pliers and long forceps, a handpiece packed with its bur block, instruments that overhang a 7\" × 13\" pouch. Short routine packs are faster self-sealed, because there is no pre-heat and no alignment step. Clinics running both formats keep the sealer on the bench for the long packs and use pouches for everything else — the machine earns its space on the ten per cent of packs that no pouch fits.\u003c\/p\u003e\n\n\u003ch2\u003eWhere do I get the log for sealed packs?\u003c\/h2\u003e\n\u003cp\u003eA sealed pack is logged exactly like a pouch: date, cycle, sterilizer, contents. \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003ePrint the sterilization record sheet\u003c\/a\u003e, or build your own columns for roll-cut packs in the \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003elog generator\u003c\/a\u003e. Keep the roll lot number with the record — it is what lets a seal failure be traced to a batch of packaging. If you are validating a new pack format before it goes into routine use, \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003eask a sterilization compliance specialist\u003c\/a\u003e what has to be tested and written down first.\u003c\/p\u003e\n\n\n\n\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSeal method: constant heat (thermostatic)\u003c\/li\u003e\n\u003cli\u003eSeal width: 12 mm\u003c\/li\u003e\n\u003cli\u003eMax seal length: 300 mm (12\")\u003c\/li\u003e\n\u003cli\u003eMax roll width: 300 mm — up to three rolls side by side\u003c\/li\u003e\n\u003cli\u003eVoltage \/ frequency: 110V \/ 60Hz (Canadian standard); 220V also available\u003c\/li\u003e\n\u003cli\u003ePower consumption: 100 W\u003c\/li\u003e\n\u003cli\u003ePreheating time: 2–3 minutes\u003c\/li\u003e\n\u003cli\u003eOverheat protection: yes\u003c\/li\u003e\n\u003cli\u003eHousing: stainless steel\u003c\/li\u003e\n\u003cli\u003eWaterproof grade: IPX0 (indoor use)\u003c\/li\u003e\n\u003cli\u003eConformity: EU Low Voltage Directive 2014\/35\/EU\u003c\/li\u003e\n\u003cli\u003eCompatible roll widths: 5 \/ 7.5 \/ 10 \/ 15 \/ 20 \/ 25 \/ 30 cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWho uses it\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDental and veterinary clinics, medical offices, tattoo and piercing studios and laboratories that sterilize instruments in pouches — anyone who needs dependable seals that hold through autoclave cycles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance Support\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDistributed by CliniEco Medical under Health Canada MDEL #35334. 1-year warranty. Documentation and country-of-origin details available on request.\u003c\/p\u003e\n\u003cp\u003eFor sealing sterilization pouches and rolls in professional settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHave a question about your own facility?\u003c\/strong\u003e Send it in and you will get a written answer specific to your setup, with the regulation or standard it is based on cited. \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003eAsk your compliance question\u003c\/a\u003e.\u003c\/p\u003e\n\u003c!-- sterilization-system-links --\u003e\n\u003cdiv style=\"max-width:820px;margin:28px auto 8px;padding:16px 20px;border:1px solid #e2e8f0;border-radius:12px;background:#f8fafc\"\u003e\n\u003cp style=\"margin:0 0 10px;font-weight:700;color:#206270;font-size:15px\"\u003ePart of the same sterilization system\u003c\/p\u003e\n\u003cul style=\"margin:0;padding-left:18px;line-height:1.9;font-size:15px;color:#334155\"\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-us\/products\/clinieco-sterilization-pouch-class-4-self-sealing-dual-indicator-200-per-box\"\u003eSterilization Pouches — Class 4, Assorted 200-Pack\u003c\/a\u003e — $11.99 (case of 10 — $95.92)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-us\/products\/clinieco-medical-sterilization-roll-pre-cut-sheets-50m-roll\"\u003eSterilization Roll — 50 m\u003c\/a\u003e — $105.00\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-us\/products\/clinieco-medical-autoclave-tape-sterilization-indicator-tape-3-roll-set\"\u003eAutoclave Indicator Tape — 3-Roll Set\u003c\/a\u003e — $159.92\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eRelated reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/self-seal-pouches-and-rolls-cost-per-load\"\u003eSelf-seal pouches vs rolls: cost per load in a busy clinic\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/pouch-vs-roll-sterilization-cost-canada\"\u003ePouch vs roll sterilization: which is more cost-effective in Canada\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/cassette-pouch-vs-wrap\"\u003ePeel pouch vs wrap: seal integrity and speed for cassette packs\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/where-to-buy-dental-ultrasonic-cleaner-dental-clinics-nova-scotia\"\u003eWhere to Buy Dental Ultrasonic Cleaner for Dental Clinics in Nova Scotia\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":49012264108254,"sku":"CLI-SEAL-300","price":349.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/SEALER-HERO-logo-20261110_4f5bdfea-2e19-4287-8927-3df61b22de82.jpg?v=1794344580"},{"product_id":"clinieco-wireless-dental-headlight-core-35k-lux-ultra-light-for-loupes","title":"CliniEco Wireless Dental Headlight — Core, 32K Lux, Ultra-Light (for Loupes)","description":"\u003ch3\u003eBright, light, and available now\u003c\/h3\u003e\n\u003cp\u003eA wireless headlight that puts a genuinely bright, true-colour field on the work without adding noticeable weight to your loupe frame. The charger carries ETL certification, with a lamp head of approximately \u003cstrong\u003e11.80 g\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIf you need a headlight this week rather than this quarter, this is the model we ship from Toronto.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/wireless-dental-headlight-lux-cri-weight\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/41cb9efa3aa297d250721f480412f5f5.jpg?v=1788977578\" alt=\"CliniEco Wireless Dental Headlight — Core, 32K Lux, Ultra-Light (for Loupes)\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eWhich loupes will this headlight fit?\u003c\/h2\u003e\n\u003cp\u003eThe mount is a clip that opens to 15 mm, and the light mounts directly on the frames you already wear: the \u003ca href=\"\/en-us\/products\/clinieco-flip-up-dental-loupes-2-5x-with-wireless-headlight-set\"\u003e2.5× flip-up loupes\u003c\/a\u003e and the \u003ca href=\"\/en-us\/products\/clinieco-flip-up-dental-loupes-3-5x-with-wireless-headlight-set\"\u003e3.5× flip-up loupes\u003c\/a\u003e are both built to take it, and the clip grips the frame bridge, which is roughly 5 mm across. What to check before you order: the mount point on your existing frame, not the loupe barrel — a frame that clamps to a prescription insert in a different way will need its own bracket, and that is a question for us before the order rather than after it.\u003c\/p\u003e\n\n\u003ch2\u003eWhat is in the box, and what is not?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eIncluded\u003c\/th\u003e\n\u003cth\u003eNote\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp head (32,000 lux class at 40 cm, approx. 11.80 g)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eThe part that mounts on the frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClip mount, opens to 15 mm\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eFits the loupe frames listed above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrange filter\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eSupplied with the lamp head; replacements available separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRechargeable battery\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eHot-swap capable; USB-C charging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd\u003e2 or 3 — selected above\u003c\/td\u003e\n\u003ctd\u003eRechargeable packs, USB-C, hot-swap capable. The 2-pack version ships with 2 packs; the 3-pack version ships with 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCamera, recording, built-in magnification\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eThe loupes magnify; the light only lights the field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe specification list above is the whole of it, with nothing left to a footnote: the battery is rechargeable and hot-swap capable, and a spare is listed as optional rather than included. Nothing about the price changes with the frame you already own, and nothing extra is needed to wear it: mount it, charge it, and it works.\u003c\/p\u003e\n\n\u003ch2\u003eHow does the Core compare with the Pro model?\u003c\/h2\u003e\n\u003cp\u003eSame platform, two positions on the range. The Core is the 32,000 lux class light measured at 40 cm, at roughly 11.80 g of lamp head, which is the version that suits a practice doing routine restorative and hygiene work all day. The \u003ca href=\"\/en-us\/products\/clinieco-wireless-dental-headlight-pro-50k-lux-dual-battery\"\u003ePro model\u003c\/a\u003e adds a second battery for continuous use and a higher output, and it is the one to look at if you work long sessions without a charging break. Buy the Core when the light is a working tool you want to forget you are wearing; buy the Pro when a swapped battery mid-afternoon is the alternative you are trying to avoid.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does the light add to the frame over a full day?\u003c\/h2\u003e\n\u003cp\u003eRoughly 11.80 g at the lamp head, before the battery — the figure that matters when the frame is already on your nose for eight hours. Weight is cumulative in a way that brightness is not: a heavy light is felt by mid-afternoon and starts changing how you hold your head over the patient, which is a worse outcome than a slightly dimmer field. That trade is why the weight is quoted in the specification list above rather than left to a photo.\u003c\/p\u003e\n\n\u003ch2\u003eHow do you cost a headlight over its working life?\u003c\/h2\u003e\n\u003cp\u003e$399.00 is one line of capital, not a monthly cost. Spread across three years of clinical use at roughly 240 working days a year, it works out to about $133 a year, or about 55 cents a working day — the same order as a box of gloves a month. If you are equipping several operatories, price the whole room in the \u003ca href=\"\/en-us\/pages\/clinic-supply-planner\"\u003eclinic supply and cost planner\u003c\/a\u003e rather than one lamp at a time, and open a \u003ca href=\"\/en-us\/pages\/wholesale\"\u003efacility and clinic account\u003c\/a\u003e when the order covers more than one chair. If the alternative is scheduling around a shared overhead light or working with a head mirror, the comparison is not the price of this lamp against another lamp; it is the price against the minutes you lose to poor light on every anterior restoration.\u003c\/p\u003e\n\u003ch3\u003eSpecifications you can hold us to\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eLight output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e32,000 lux class, \u003cstrong\u003emeasured at 40 cm\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eLamp head weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eapprox. 11.80 g (without battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eColour rendering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eCRI ≥90 — high-CRI medical-grade LED, chosen for colour fidelity at the chair, so the shade differences you rely on stay visible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eDimming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eMulti-step manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eMount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eClip, opens to 15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e2 or 3 rechargeable packs (select above), USB-C, hot-swap capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eCharging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eUSB-C, approx. 2.5 h to full\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eResin filter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eOrange, included — one ships with every headlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eImporter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eCliniEco Medical — Health Canada MDEL #35334\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eUltra-light lamp head (~11.80 g)\u003c\/strong\u003e — comfortable for all-day wear with loupes.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e32,000 lux class output at 40 cm\u003c\/strong\u003e — a bright, true-colour field at working distance.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eLow-battery indicator\u003c\/strong\u003e — no surprise shutdowns mid-procedure.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eUSB-C charging\u003c\/strong\u003e — the cable you already have.\u003c\/p\u003e\n\n\u003ch3\u003eWhy the lux figure is quoted at a working distance, and why that matters\u003c\/h3\u003e\n\u003cp\u003eLight falls off with distance, so a lux figure on its own means nothing. \u003cstrong\u003eEvery figure we quote is measured at 40 cm\u003c\/strong\u003e — roughly the distance from your eyes to a patient's mouth when you are wearing loupes. This is the number that describes what you will actually experience.\u003c\/p\u003e\n\u003cp\u003eIf you see a headlight advertised with a very large lux figure and no stated distance, that figure was almost certainly measured as close to the emitter as possible. It is not comparable to ours, and it is not comparable to anything you will see while working.\u003c\/p\u003e\n\u003ch3\u003eColour rendering is not a decoration\u003c\/h3\u003e\n\u003ch3\u003eWeight, because you wear it all day\u003c\/h3\u003e\n\u003cp\u003eThe Core lamp head is approximately \u003cstrong\u003e11.80 g\u003c\/strong\u003e without the battery. On a loupe frame this is the difference between lighting that disappears into your working day and lighting that you are aware of by mid-afternoon.\u003c\/p\u003e\n\u003ch3\u003eWhat we can state plainly\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eWe quote lux at 40 cm and say so.\u003c\/strong\u003e Compare any other product on the same terms before you decide.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eThe mount is a clip mount.\u003c\/strong\u003e It fits CliniEco Flip-Up Dental Loupes and most standard loupe frames, so you are not locked into one system.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eBattery behaviour is stated, not implied.\u003c\/strong\u003e If a light will not run continuously without a swap, we say so and tell you what solves it, rather than describing \"all-day battery life\" and leaving you to find out.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eImporter of record:\u003c\/strong\u003e Ecology Source New Energy Technology Co., LTD. o\/a CliniEco Medical, Health Canada MDEL #35334. Four brightness levels, 6,000 K, CRI 90. Ships from Toronto, Ontario.\u003c\/p\u003e\n\n\u003c!-- CROSSLINK-C-GROUP-20260926 --\u003e\n\u003ch3\u003eRelated in this range\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-us\/products\/clinieco-flip-up-dental-loupes-2-5x-magnification-adjustable-lightweight\"\u003eCliniEco Flip-Up Dental Loupes — 2.5×\u003c\/a\u003e — The frame this light mounts to.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-us\/products\/clinieco-flip-up-dental-loupes-3-5x-magnification-adjustable-lightweight\"\u003eCliniEco Flip-Up Dental Loupes — 3.5×\u003c\/a\u003e — The frame this light mounts to.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/where-to-buy-dental-ultrasonic-cleaner-dental-clinics-nova-scotia\"\u003eWhere to Buy Dental Ultrasonic Cleaner for Dental Clinics in Nova Scotia\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/where-to-buy-dental-loupes-wireless-headlight-set-quebec\"\u003eWhere to Buy Dental Loupes + Wireless Headlight Set for Dental Clinics in Quebec\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow do you mount the light on a frame you already own?\u003c\/h2\u003e\n\u003cp\u003eThe mount is a clip that opens to 15 mm and grips the frame bridge, which on the loupe frames this light is built for is roughly 5 mm across. The clip is the part to check before ordering, not the loupe barrel: a frame that carries a prescription insert, or that clamps in a different way, needs its own bracket, and that is a question to settle with us before the order rather than after it.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eWhat you already own\u003c\/th\u003e\n\u003cth\u003eHow it mounts\u003c\/th\u003e\n\u003cth\u003eWhat to check first\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCliniEco 2.5× flip-up loupes\u003c\/td\u003e\n\u003ctd\u003eClip onto the frame bridge\u003c\/td\u003e\n\u003ctd\u003eNothing beyond the usual fit; the frame is built to take it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCliniEco 3.5× flip-up loupes\u003c\/td\u003e\n\u003ctd\u003eClip onto the frame bridge\u003c\/td\u003e\n\u003ctd\u003eSame mount, same clip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThird-party loupes with a standard light bar\u003c\/td\u003e\n\u003ctd\u003eMost clamp to the same bar\u003c\/td\u003e\n\u003ctd\u003eThe clip or bar diameter, and whether the battery sits behind the head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame with a prescription insert\u003c\/td\u003e\n\u003ctd\u003eUsually needs its own bracket\u003c\/td\u003e\n\u003ctd\u003eSend us the frame model before ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo loupe frame, or shared use\u003c\/td\u003e\n\u003ctd\u003eNot included in this kit — please confirm before ordering\u003c\/td\u003e\n\u003ctd\u003eWhether the light will be shared between clinicians\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe clip is the part that matters: it grips the bridge of the frame you already wear, so the light travels with your loupes and nothing extra has to be bought to mount it.\u003c\/p\u003e\n\n\u003ch2\u003eTwo battery packs or three: how does a practice schedule a day?\u003c\/h2\u003e\n\u003cp\u003eThe honest answer starts with what this page does not quote. There is no runtime-per-pack figure printed here, so a practice should not plan a day around an assumed number of hours. What is quoted is the behaviour that matters instead: the packs are rechargeable over USB-C, each reaches full charge in roughly 2.5 hours, they are hot-swap capable, and a low-battery indicator warns before shutdown rather than during a procedure.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eWhat is stated\u003c\/th\u003e\n\u003cth\u003eFigure\u003c\/th\u003e\n\u003cth\u003eHow a room uses it\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging\u003c\/td\u003e\n\u003ctd\u003eUSB-C, roughly 2.5 hours to full\u003c\/td\u003e\n\u003ctd\u003eOne pack on the charger during a coffee break or a lunch hour covers a swap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwap\u003c\/td\u003e\n\u003ctd\u003eHot-swap capable\u003c\/td\u003e\n\u003ctd\u003eThe light does not have to come off the frame to change packs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow-battery warning\u003c\/td\u003e\n\u003ctd\u003eIndicator on the light\u003c\/td\u003e\n\u003ctd\u003eGives the clinician the chance to swap between patients rather than mid-procedure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacks included\u003c\/td\u003e\n\u003ctd\u003e2 or 3, selected above\u003c\/td\u003e\n\u003ctd\u003eA 2-pack version ships with two packs; a 3-pack version with three\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime per pack\u003c\/td\u003e\n\u003ctd\u003eNot quoted on this page\u003c\/td\u003e\n\u003ctd\u003ePlan on swapping and charging rather than on a claimed number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThat is the difference between the two configurations: two packs is a swap-and-charge day where the spare lives on the charger, and three packs absorbs a longer session or a room where two clinicians share one light. If a practice works long sessions back to back, the third pack is the cheaper answer than a mid-afternoon dark chair — and if the light only runs a few hours a day, the second pack is already more than the day needs.\u003c\/p\u003e\n\n\u003ch2\u003eHow should a practice judge a lux figure before buying?\u003c\/h2\u003e\n\u003cp\u003eLight falls off with distance, so a lux figure with no stated distance is not a specification, it is a number. Every figure quoted for this light is measured at 40 cm, which is roughly the distance from the eyes to a patient's mouth when working through loupes — the distance the light is actually used at. That is why the page says 32,000 lux class at 40 cm rather than simply 32,000 lux.\u003c\/p\u003e\n\u003cp\u003eWhen comparing a light from elsewhere, the first question is where the figure was measured. A very large lux number with no distance attached was almost certainly taken close to the emitter, and it cannot be compared with a figure taken at working distance. Ask for the distance before you ask for the output, and ask whether the figure is a class or a measured value at that distance.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does colour rendering change at the chair?\u003c\/h2\u003e\n\u003cp\u003eThe LED is specified at CRI ≥90, which is the part of the purchase that shows up in shade work rather than in brightness. A high-CRI emitter is chosen so that colour differences stay visible at the chair; a light that is bright but shifts colour makes a shade match a negotiation with the lamp instead of a comparison of teeth. The page quotes the figure rather than an adjective, and that is deliberate — a buyer can check a CRI number against a manufacturer's data sheet, and cannot check a phrase like true colour.\u003c\/p\u003e\n\u003cp\u003eBrightness is adjustable in multiple manual steps, so the light can be turned down for a shaded field rather than left at one output all day. That matters more than it sounds over an eight-hour day: a light that only has one setting is a light that a clinician ends up tilting away from.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does 11.80 g mean across a working day?\u003c\/h2\u003e\n\u003cp\u003eThe lamp head weighs approximately 11.80 g without the battery, and that figure is the whole argument for this model. Weight on a loupe frame is cumulative in a way that brightness is not: a light that is a few grams heavier is noticed by mid-afternoon, and a clinician who notices the light starts holding their head differently over the patient. The battery is carried separately in this design, which is the reason the lamp head can stay at that weight.\u003c\/p\u003e\n\u003cp\u003eFor a practice equipping several operatories, the weight question is also a sharing question: a light that is comfortable on one clinician's frame is a light that can be handed to the next clinician with the frame, rather than one that only suits the person who chose it.\u003c\/p\u003e\n\n\u003ch2\u003eWhat ships in the box, and what do you add later?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eIncluded\u003c\/th\u003e\n\u003cth\u003eWhat it is for\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLamp head, 32,000 lux class at 40 cm, approx. 11.80 g\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eThe part that mounts on the frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClip mount, opens to 15 mm\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eFits the loupe frames listed above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrange resin filter\u003c\/td\u003e\n\u003ctd\u003eYes — one with every headlight\u003c\/td\u003e\n\u003ctd\u003eSupplied with the lamp head; replacements available separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRechargeable battery packs\u003c\/td\u003e\n\u003ctd\u003e2 or 3, selected above\u003c\/td\u003e\n\u003ctd\u003eUSB-C, hot-swap capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging\u003c\/td\u003e\n\u003ctd\u003eUSB-C cable; the charger carries ETL certification\u003c\/td\u003e\n\u003ctd\u003eThe cable a practice already owns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCamera, recording, built-in magnification\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eThe loupes magnify; the light only lights the field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe spare pack is the only thing a practice usually adds, and it is listed as an option rather than bundled for a reason: a room that charges during lunch does not need one, and a room with back-to-back long sessions does.\u003c\/p\u003e\n\n\u003ch2\u003eWho this light suits\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSetting\u003c\/th\u003e\n\u003cth\u003eFits?\u003c\/th\u003e\n\u003cth\u003eReason\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral restorative and hygiene work all day\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eThe lamp head stays light, which is what all-day wear needs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShared frame between clinicians\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eThe clip fits the frames both loupe models use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinician without loupes, working in shadow\u003c\/td\u003e \u003ctd\u003eOnly with a separate headband\u003c\/td\u003e \u003ctd\u003eThis kit is clip-mount; a headband version is not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong surgical sessions without a charging break\u003c\/td\u003e\n\u003ctd\u003eOnly with the third pack\u003c\/td\u003e\n\u003ctd\u003eA swap is quick, but it is still a swap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnyone wanting recording or magnification from the light\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eThe light lights the field; magnification is the loupes' job\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhat to check when it arrives\u003c\/h2\u003e\n\u003cp\u003eFive minutes at the bench, before the first clinic day. Clip the light onto the frame and check that it grips the bridge without rocking; charge both or all three packs to confirm each takes a charge over USB-C; run the light through its dimming steps and confirm it returns to a usable setting; and check that the orange filter sits in place on the lamp head.\u003c\/p\u003e\n\u003cp\u003eIf anything does not sit right, that is the moment to tell us — before the light has been through a clinic day, and long before it has been through a month of them.\u003c\/p\u003e\n\n\u003ch2\u003eWhat is the light certified for, and what is it not?\u003c\/h2\u003e\n\u003cp\u003eThree separate things are stated about this product, and they answer three different questions. The photobiological safety of the light itself is addressed by compliance with IEC 62471, the light carries CE and FCC marks, and the charger carries ETL certification. None of those is a claim about what the light does clinically.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eWhat is stated\u003c\/th\u003e\n\u003cth\u003eWhat it answers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotobiological safety\u003c\/td\u003e\n\u003ctd\u003eComplies with IEC 62471\u003c\/td\u003e\n\u003ctd\u003eWhether the lamp has been assessed as a light source rather than only as an electrical product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct marking\u003c\/td\u003e\n\u003ctd\u003eCE and FCC\u003c\/td\u003e\n\u003ctd\u003eThe marks carried by the light as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging\u003c\/td\u003e\n\u003ctd\u003eThe charger carries ETL certification\u003c\/td\u003e\n\u003ctd\u003eElectrical safety of the charging path, which is the part a clinic plugs in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended use\u003c\/td\u003e\n\u003ctd\u003eA professional lighting aid\u003c\/td\u003e\n\u003ctd\u003eIt is not a diagnostic or therapeutic device, and nothing on this page presents it as one\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThat last line is worth keeping in the same paragraph as the certifications, because the two are easy to blur. A bright light on a loupe frame helps a clinician see; it does not diagnose anything, and a practice should not describe it to a client or an insurer as if it did.\u003c\/p\u003e\n\n\u003ch2\u003eHow does a headlight change the way a room is laid out?\u003c\/h2\u003e\n\u003cp\u003eMost practices have an overhead light that everyone shares, and the usual arrangement is that whoever is under it works, while whoever is not waits or angles the patient towards the beam. A worn light changes that arithmetic: the clinician who has one carries their own field of light, and the room stops being scheduled around a single lamp.\u003c\/p\u003e\n\u003cp\u003eThe alternatives a practice usually weighs are an overhead unit that follows the chair, a head mirror, or a worn light. A head mirror needs an external source and a trained hand; an overhead unit is fixed to the chair, so a second clinician working at the same time either shares the beam or works in shadow. A worn light travels with the person, which is why it tends to get bought once a practice has more than one clinician working at once — and why a light that moves between clinicians is worth planning for before the second chair is equipped.\u003c\/p\u003e\n\u003cp\u003eWhat a worn light is not is a replacement for room lighting. The treatment room still needs the general light it has; the headlight is for the field, not for the room.\u003c\/p\u003e\n\n\u003ch2\u003eHow should a practice compare this light against a lower-cost lamp?\u003c\/h2\u003e\n\u003cp\u003eCompare three figures and the distance each was measured at: output at the working distance, the weight of the part that sits on the face, and what is included. A lamp sold on output alone invites the comparison that flatters it, because output is the one figure that can be inflated by measuring closer to the emitter. Weight is the figure that cannot be inflated, and it is the one a clinician feels by the afternoon. Included parts are the third: a light that needs a bracket, a filter and a spare battery bought separately is not the same purchase as one that arrives with them.\u003c\/p\u003e\n\u003cp\u003eIf a practice is choosing between two lights, ask both suppliers for the working distance behind the lux figure and the weight of the lamp head without the battery. A supplier who cannot answer either is telling you something useful about the specification sheet.\u003c\/p\u003e\n\u003ch2\u003eCuring light vs operatory light: what the orange filter is for\u003c\/h2\u003e\n\u003cp\u003eTwo different lights act on composite during a restorative appointment, and only one of them comes from your headlight. Keeping them apart is what tells you whether the accessory is worth carrying.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe lamp you point into the prep.\u003c\/strong\u003e A white LED beam carries a blue component, and blue is the end of the spectrum that starts the setting reaction in composite. The orange filter sits over the lamp head and takes that blue end out of the beam you are aiming into the mouth, which buys working time at the point where it matters and lets a shade be read without looking through a blue-washed field.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe room light.\u003c\/strong\u003e A filter on a headlight does not filter the operatory. It is a disc over your own lamp; the ceiling light and the dental unit's light still fall on the tooth. Anything that claims a clip-on loupe filter protects the restoration from the room is describing an accessory that does not exist.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eWhat it is\u003c\/th\u003e\n\u003cth\u003eWhat it changes at the chair\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrange filter\u003c\/td\u003e\n\u003ctd\u003eA disc that fits over the wireless headlight's lamp head\u003c\/td\u003e\n\u003ctd\u003eRemoves the blue end from the headlight's own beam: more working time on uncured composite, and a shade read closer to room light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoom and unit light\u003c\/td\u003e\n\u003ctd\u003eThe ambient lighting of the operatory\u003c\/td\u003e\n\u003ctd\u003eNothing: no filter on a headlight changes the light in the room\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuring light\u003c\/td\u003e\n\u003ctd\u003eThe device that sets the restoration deliberately\u003c\/td\u003e\n\u003ctd\u003eNothing: the filter does not shorten or extend a curing cycle, and it is not a substitute for one\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eWhat it fits, and what it costs.\u003c\/strong\u003e Every CliniEco wireless headlight ships with one orange filter, so this is a spare or a replacement rather than a first purchase: \u003ca href=\"\/en-us\/products\/custom-cut-orange-filter-dental-loupes\"\u003ea spare is $99\u003c\/a\u003e. It fits the lamp head, not the loupe; the loupes take no filter of their own. The 15 mm clip is how the lamp attaches to a frame, not how the filter attaches to the lamp.\u003c\/p\u003e\n\u003cp\u003eThe same filter fits the angled pairs because the mount is the same, so the light clips to the \u003ca href=\"\/en-us\/products\/clinieco-ergo-angled-dental-loupes-3-5x-with-wireless-headlight\"\u003e3.5× angled set\u003c\/a\u003e exactly as it does to the straight flip-up frames on this page.\u003c\/p\u003e\n","brand":"CliniEco Medical","offers":[{"title":"2 battery packs","offer_id":49012566261982,"sku":"CLI-HL-CORE-2B","price":399.0,"currency_code":"CAD","in_stock":true},{"title":"3 battery packs","offer_id":49381078204638,"sku":"CLI-HL-CORE-3B","price":429.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CLI-HL-CORE-HERO-v3-20261117.jpg?v=1794951992"},{"product_id":"clinieco-flip-up-dental-loupes-2-5x-magnification-adjustable-lightweight","title":"CliniEco Galilean Flip-Up Dental Loupes — 2.5× Magnification, Adjustable, Lightweight","description":"\u003ch3\u003eFlip-up loupes you can use on the day they arrive\u003c\/h3\u003e\n\u003cp\u003eMost professional loupes are made to order: you are measured, they are built to your anatomy, and you wait several weeks for the fitting. They are good — and they are impractical if you need magnification now, if more than one clinician will use the pair, or if your working posture is likely to change.\u003c\/p\u003e\n\u003cp\u003eThese are \u003cstrong\u003e2.5× flip-up loupes with adjustable interpupillary distance and adjustable declination\u003c\/strong\u003e. They arrive ready to use. No fitting appointment, no multi-week wait, and they can be handed to a colleague who will get the same result.\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cstrong\u003eReady-to-wear flip-up loupes come with one trade-off that should be said in the first line: the working distance is fixed per pair.\u003c\/strong\u003e Four groups — short 280–380 mm, medium 360–460, long 440–540 and extra-long 500–600 — are selected when the pair is built and then locked; interpupillary distance and declination stay adjustable, which is what lets one frame pass between clinicians. The \u003ca href=\"\/en-us\/products\/clinieco-wireless-dental-headlight-core-35k-lux-ultra-light-for-loupes\"\u003eCore wireless headlight\u003c\/a\u003e clips to the same mount for clinicians who end up working in shadow.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/custom-fitted-vs-adjustable-flip-up-dental-loupes\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/10_scene.png?v=1790374782\" alt=\"CliniEco Flip-Up Dental Loupes — 2.5× Magnification, Adjustable, Lightweight\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eWhich flip-up loupes suit a team that shares one pair between clinicians?\u003c\/h2\u003e\n\u003cp\u003eThe 2.5× pair, provided the people sharing it work at the same distance. Interpupillary distance and declination adjust on the frame, so a hygienist and a dentist can each set the optics to their own eyes in seconds; the working distance is built in when the pair is made, so two clinicians who sit at 400 mm and at 480 mm need two pairs, not one. Measure each person's natural distance before ordering rather than assuming one pair will suit everyone — the section below explains how to take that measurement. Sharing works where the team shares a posture, and it stops where the team does not.\u003c\/p\u003e\n\u003ch2\u003eHow much do flip-up loupes cost, and what does a headlight add?\u003c\/h2\u003e\n\u003cp\u003eThis 2.5× pair lists at $329.00. The 3.5× pair is $699.00, and the bundles that pair the loupes with a wireless headlight are $644.00 for 2.5× and $959.00 for 3.5×; the Core headlight on its own is $429.00, for a clinician who already owns loupes and only needs light. The arithmetic that matters is per user rather than per clinic: a shared pair is one price, but a second clinician with a different working distance needs a second pair, and that line is usually what decides the budget.\u003c\/p\u003e\n\u003ch2\u003eDoes a flip-up loupe fit a headlight you already own?\u003c\/h2\u003e\n\u003cp\u003eThe frame takes a clip-on light, so our Core headlight attaches directly and most third-party loupe lights clamp to the same bar. Two things to check on a light you already own: the clip or bar diameter, and whether the battery sits behind the head rather than on the frame — a battery carried on the frame is the usual reason a light feels heavier than the loupes. If you are unsure, send us the model and we will tell you whether it fits, rather than sell you a second light you do not need.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eFlip-up loupe configurations in this range — magnification, what the price includes, price (CAD)\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eMagnification\u003c\/th\u003e\n\u003cth\u003eWhat the price includes\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePair only, this listing\u003c\/td\u003e\n\u003ctd\u003e2.5×\u003c\/td\u003e\n\u003ctd\u003eLoupes, protective case, microfibre cloth\u003c\/td\u003e\n\u003ctd\u003e$329.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePair only\u003c\/td\u003e\n\u003ctd\u003e3.5× magnification\u003c\/td\u003e\n\u003ctd\u003eLoupes, protective case, microfibre cloth\u003c\/td\u003e\n\u003ctd\u003e$699.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePair with wireless headlight\u003c\/td\u003e\n\u003ctd\u003e2.5×\u003c\/td\u003e\n\u003ctd\u003e2.5× pair plus a wireless headlight\u003c\/td\u003e\n\u003ctd\u003e$644.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePair with wireless headlight\u003c\/td\u003e\n\u003ctd\u003e3.5× magnification\u003c\/td\u003e\n\u003ctd\u003e3.5× pair plus the Core 32K lux headlight\u003c\/td\u003e\n\u003ctd\u003e$959.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeadlight only\u003c\/td\u003e\n\u003ctd\u003enone\u003c\/td\u003e\n\u003ctd\u003eWireless headlight for loupes you already own\u003c\/td\u003e\n\u003ctd\u003e$429.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecond pair for the same working distance\u003c\/td\u003e\n\u003ctd\u003e2.5×\u003c\/td\u003e\n\u003ctd\u003eSame pair again — no new measurement needed\u003c\/td\u003e\n\u003ctd\u003e$329.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eWhat decides the purchase.\u003c\/strong\u003e Working distance first, magnification second, light third: a pair built for the wrong distance strains the neck whatever the optics do. The \u003ca href=\"\/en-us\/pages\/clinic-supply-planner\"\u003eclinic supply planner\u003c\/a\u003e is where a multi-chair practice converts chairs and clinicians into pairs and headsets. Send your height and whether you work seated or standing and we will say which working distance we would order — including telling you to take the \u003ca href=\"\/en-us\/products\/clinieco-flip-up-dental-loupes-3-5x-magnification-adjustable-lightweight\"\u003e3.5× pair\u003c\/a\u003e instead. Group purchases for a whole practice are quoted on the \u003ca href=\"\/en-us\/pages\/wholesale\"\u003eclinic ordering page\u003c\/a\u003e. CliniEco Medical imports these loupes under MDEL #35334.\u003c\/p\u003e\n\u003ch3\u003eSpecifications you can hold us to\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eMagnification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e2.5×, multi-coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eWorking distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eSelectable — four groups: 280–380 \/ 360–460 \/ 440–540 \/ 500–600 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eMount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eFlip-up, adjustable declination, clip-on light mount (15 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eFrame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTitanium alloy frame, matte finish, approx. 70 g incl. optics\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eField of view 100–110 mm; 42 g with the frame. In the box\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eLoupes, protective case, microfibre cloth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eImporter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eCliniEco Medical — Health Canada MDEL #35334\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eAdjustable interpupillary distance\u003c\/strong\u003e — one frame fits different users, no custom lab work.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eAdjustable declination with flip-up optics\u003c\/strong\u003e — lift the lenses out of the way between patients without removing the frame.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eMulti-coated optics\u003c\/strong\u003e — bright, high-contrast, low-distortion image across the field.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eFour selectable working-distance groups\u003c\/strong\u003e — 280–380 \/ 360–460 \/ 440–540 \/ 500–600 mm.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eClip-on light mount, 15 mm opening\u003c\/strong\u003e — fits the CliniEco Wireless Headlight and most standard loupe lights.\u003c\/p\u003e\n\n\u003ch3\u003eWhich one to choose, and the trade-off nobody explains\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHigher magnification means a smaller field of view. That is physics, not a product limitation.\u003c\/strong\u003e Our 2.5× shows a wider field at the same working distance; our 3.5× shows a narrower one. More detail, less context in the frame. Choose the magnification that matches the work, not the biggest number on the page.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e2.5×\u003c\/strong\u003e — general dentistry, hygiene, restorative. You can see most of an arch without repositioning, which is what you want when you are working across a quadrant.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e3.5×\u003c\/strong\u003e — endodontics, surgical and detailed restorative work, where you are looking at one tooth or one site closely and do not need the surrounding view.\u003c\/p\u003e\n\u003ch3\u003eWorking distance: the setting that decides whether loupes work for you\u003c\/h3\u003e\n\u003cp\u003eEach pair offers four selectable working distances — \u003cstrong\u003e280–380 mm (short), 360–460 mm (medium), 440–540 mm (long) and 500–600 mm (extra-long)\u003c\/strong\u003e. Pick the wrong one and you will be straining or sitting badly, no matter how good the optics are.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasure it before you order.\u003c\/strong\u003e Sit or stand the way you actually work, close your eyes, let your arms drop naturally, then open your eyes and have someone measure from your eyes to your hands. That distance is the one to order. Most clinicians land at 450 mm; shorter clinicians and those who work seated close often need the short band, 280–380 mm; taller clinicians working over a standing patient often need the long or extra-long band, 440–600 mm. If you are unsure, tell us your height and whether you work seated or standing, and we will tell you which one we would pick.\u003c\/p\u003e\n\u003ch3\u003eWhy these are adjustable rather than custom-made — and when that is the wrong answer for you\u003c\/h3\u003e\n\u003cp\u003eCustom loupes are made to one person's anatomy. They are excellent, and if you are the only person who will ever wear them and you are willing to wait several weeks and pay for the fitting, they are a reasonable purchase. What they are not is fast, shared, or replaceable.\u003c\/p\u003e\n\u003cp\u003eOurs take the other route: \u003cstrong\u003eadjustable interpupillary distance and adjustable declination on a flip-up mount\u003c\/strong\u003e, ready to use out of the box. There is no fitting appointment and no multi-week wait. The flip-up optics lift out of the way between patients without removing the frame, which matters when you are moving between magnification and unaided work all day.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere we would tell you to go custom instead:\u003c\/strong\u003e if you have a strong preference for a fixed, individually-fitted declination angle and you know your working posture will never change, a custom pair will feel better than any adjustable pair. We would rather say that than pretend adjustability is identical to a custom fit. It is not. It is faster, cheaper, and it works for anyone who picks them up — which is why clinics standardise on them.\u003c\/p\u003e\n\u003ch3\u003eWhat they mount to\u003c\/h3\u003e\n\u003cp\u003eThe clip-on mount, \u003cstrong\u003e15 mm opening\u003c\/strong\u003e, fits our CliniEco Wireless Headlight and most standard loupe lights, so you are not tied to one brand of light. The frame is titanium alloy at approximately \u003cstrong\u003e70 g including optics\u003c\/strong\u003e — light enough that the weight is not what you notice after an hour.\u003c\/p\u003e\n\u003ch3\u003eIn the box\u003c\/h3\u003e\n\u003cp\u003eLoupes, protective case, microfibre cloth.\u003c\/p\u003e\n\u003ch3\u003eWhat we can state plainly\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eThe optics are multi-coated\u003c\/strong\u003e — bright, high-contrast and low-distortion across the field. We publish the figures we can check rather than adjectives.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eSelectable working distance is four groups\u003c\/strong\u003e (280–380 \/ 360–460 \/ 440–540 \/ 500–600 mm), not a continuous adjustment. Know which one you need before ordering.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eWe will tell you if the wrong magnification or working distance is what you are about to buy.\u003c\/strong\u003e Send us what you do and how you sit or stand, and we will answer honestly, including telling you to choose the other model.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eImporter of record:\u003c\/strong\u003e Ecology Source New Energy Technology Co., LTD. o\/a CliniEco Medical, Health Canada MDEL #35334. Ships from Toronto, Ontario.\u003c\/p\u003e\n\n\u003c!-- CROSSLINK-C-GROUP-20260926 --\u003e\n\u003ch3\u003eRelated in this range\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-us\/products\/clinieco-flip-up-dental-loupes-3-5x-magnification-adjustable-lightweight\"\u003eCliniEco Flip-Up Dental Loupes — 3.5×\u003c\/a\u003e — More magnification, narrower field of view.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-us\/products\/clinieco-wireless-dental-headlight-core-35k-lux-ultra-light-for-loupes\"\u003eCliniEco Wireless Dental Headlight — Core, 32K Lux\u003c\/a\u003e — Mounts on these loupes.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/where-to-buy-dental-ultrasonic-cleaner-dental-clinics-nova-scotia\"\u003eWhere to Buy Dental Ultrasonic Cleaner for Dental Clinics in Nova Scotia\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/where-to-buy-flip-up-dental-loupes-dental-clinics-canada\"\u003eWhere to Buy Flip-Up Dental Loupes for Dental Clinics in Canada\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow do you size a pair of flip-up loupes for someone you have not measured?\u003c\/h2\u003e\n\u003cp\u003eThe measurement is one number, and any colleague can take it in a minute. Sit or stand the way the person actually works, ask them to close their eyes and let their arms drop naturally, then have them open their eyes and hold their hands as if they were working. The distance from their eyes to their hands is the working distance to order — it is the position the optics will be used in, not a seated height or a head size.\u003c\/p\u003e\n\u003cp\u003eThat number then picks one of the four working distances this pair is built in. Interpupillary distance and declination stay adjustable once the frame arrives, which is what allows one pair to be handed between clinicians; the working distance does not move after the pair is built, so it is the one decision that has to be right at the order and cannot be corrected on the bench.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eWho is being fitted\u003c\/th\u003e\n\u003cth\u003eHow they usually work\u003c\/th\u003e\n\u003cth\u003eWhat to do before ordering\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDentist working across a quadrant\u003c\/td\u003e\n\u003ctd\u003eSeated, upright, working at arm's length\u003c\/td\u003e\n\u003ctd\u003eTake the measurement seated, in their own stool, not standing in the corridor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHygienist doing scaling all day\u003c\/td\u003e\n\u003ctd\u003eSeated, often closer to the patient than the dentist\u003c\/td\u003e\n\u003ctd\u003eTake it seated and let them settle into their working posture first — this is where a short working distance usually shows up\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinician who stands for surgical or specialist work\u003c\/td\u003e\n\u003ctd\u003eStanding, often leaning over a patient on a table\u003c\/td\u003e\n\u003ctd\u003eTake the measurement standing; a seated figure taken for a standing clinician will be too short\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociate or locum sharing a practice pair\u003c\/td\u003e\n\u003ctd\u003eWhichever posture the room's equipment imposes\u003c\/td\u003e\n\u003ctd\u003eMeasure the person, not the room — and see the next section on sharing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStudent or new graduate buying a first pair\u003c\/td\u003e\n\u003ctd\u003eStill settling into a posture\u003c\/td\u003e\n\u003ctd\u003eMeasure in the clinic they are training in, and ask whether that posture is likely to change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIf the measurement lands between two positions, tell us the figure and what the person does all day and we will say which of the two we would order. That is a conversation worth having before an order rather than after one, because the working distance is the only part of this pair that is locked.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does sharing one pair between clinicians actually require?\u003c\/h2\u003e\n\u003cp\u003eTwo of the three settings on a flip-up frame are adjustable and one is not, and that single fact decides whether sharing works. Interpupillary distance adjusts, so two people with different eye spacing can each set the optics to themselves in seconds. Declination adjusts, so a clinician who sits more upright than their colleague can tilt the optics to their own posture. The working distance was set when the pair was built, so two people who work at different distances need two pairs — not because the frame cannot be adjusted, but because there is nothing on the frame left to adjust.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSharing scenario\u003c\/th\u003e\n\u003cth\u003eDoes one pair work?\u003c\/th\u003e\n\u003cth\u003eWhat decides it\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwo clinicians, same working posture and same distance\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eEach sets interpupillary distance and declination once and writes the settings down\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDentist and hygienist working at different distances\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eTwo different working distances were built into two different pairs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePractice pair kept for locums and associates\u003c\/td\u003e\n\u003ctd\u003eOnly for the posture it was built for\u003c\/td\u003e\n\u003ctd\u003eA locum who works at a different distance will lean into the optics rather than the other way round\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurgical list twice a month, routine work the rest of the time\u003c\/td\u003e\n\u003ctd\u003eUsually one pair, one magnification\u003c\/td\u003e\n\u003ctd\u003eWhat changes between those sessions is the posture, and that is what to check before a shared pair is bought\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWhere sharing does work, write the settings down. A shared pair that gets re-set from scratch every morning is a pair that gets re-set wrong at least once a week, and the clinician who ends up with someone else's interpupillary distance is the one who notices first.\u003c\/p\u003e\n\n\u003ch2\u003eHow does a practice work out how many pairs it needs?\u003c\/h2\u003e\n\u003cp\u003eCount working distances, not clinicians. A practice with four clinicians who all sit at the same distance needs one pair per person for convenience but only one working distance to specify; a practice with two clinicians who work at different distances needs two working distances even if only two people ever wear loupes. The number that drives the order is the number of distinct distances, and the number that drives the budget is the number of people who need a pair in their hands at once.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eRoom and team\u003c\/th\u003e\n\u003cth\u003eDistinct working distances\u003c\/th\u003e\n\u003cth\u003ePairs to order\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle dentist, one operatory\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e1 — the pair follows the clinician, not the room\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDentist plus hygienist, same posture\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e2 if both wear them at the same time, 1 if the pair is handed over between appointments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDentist plus hygienist, different posture\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2 — one per distance, regardless of how the day is scheduled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThree chairs, two clinicians, one shared set\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2 working distances; a third pair only if a third person is in the room at the same time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePractice buying a pair for associates\u003c\/td\u003e\n\u003ctd\u003e1, if the associates work alike\u003c\/td\u003e\n\u003ctd\u003e1 shared pair, and measure each locum before they use it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eGroup purchases are quoted on the clinic ordering page, and the clinic supply planner is where a multi-chair practice turns chairs and clinicians into a pair count. Send the heights and whether each person works seated or standing and we will come back with the working distances we would order; if the answer is that two of your four clinicians need a different pair, that is what we will tell you.\u003c\/p\u003e\n\n\u003ch2\u003eWhy the distance setting matters more than the magnification on the page\u003c\/h2\u003e\n\u003cp\u003eA pair set to the wrong working distance makes a clinician lean in or sit back to find the focal point, all day, at every appointment. That is a posture problem created by a purchase decision, and no amount of optics fixes it. The magnification number is the more visible decision and the less consequential one: it changes how much of the arch you see at once, while the distance setting decides whether the pair is usable in the position the clinician actually works in.\u003c\/p\u003e\n\u003cp\u003eThis is also the answer to the question patients ask least and clinicians ask most: whether to buy the higher magnification. Higher magnification buys detail and costs context, in that order, and the trade is only worth making when the work is one site rather than one quadrant. The two pairs on this page share a frame, a mount and the same four working distances, so the decision is not about build quality — it is about what the clinician is looking at for most of the day.\u003c\/p\u003e\n\n\u003ch2\u003eWhat arrives in the box, and what to check on the first day?\u003c\/h2\u003e\n\u003cp\u003eThe box holds the loupes, a protective case and a microfibre cloth. There is no fitting appointment and nothing to assemble, which is the point of the adjustable frame; what there is, is a short list of checks that takes five minutes and saves a return.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat good looks like\u003c\/th\u003e\n\u003cth\u003eIf it is not right\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterpupillary adjustment\u003c\/td\u003e\n\u003ctd\u003eThe two barrels move smoothly and stay where they are set\u003c\/td\u003e\n\u003ctd\u003eSet them, note the setting, and re-check after a week of use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeclination\u003c\/td\u003e\n\u003ctd\u003eThe optics tilt to the clinician's posture and hold\u003c\/td\u003e\n\u003ctd\u003eSet it seated, at the stool they work from\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlip-up action\u003c\/td\u003e\n\u003ctd\u003eLenses lift clear of the line of sight without the frame moving\u003c\/td\u003e\n\u003ctd\u003eCheck the hinge before the first clinic day, not during it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking distance\u003c\/td\u003e\n\u003ctd\u003eThe focal point sits where the hands work, unaided\u003c\/td\u003e\n\u003ctd\u003eThis is the one thing that cannot be adjusted — talk to us before using the pair in clinic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight mount\u003c\/td\u003e\n\u003ctd\u003eThe 15 mm clip opening takes the light cleanly\u003c\/td\u003e\n\u003ctd\u003eConfirm the light's clip or bar diameter before ordering one\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight on the face\u003c\/td\u003e\n\u003ctd\u003eAbout 70 g including optics, noticed only for the first hour\u003c\/td\u003e\n\u003ctd\u003eAdjust the temples and nose pads before concluding anything about the frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe frame is titanium alloy with a matte finish, and the optics are multi-coated, which is what gives a bright, high-contrast image across the field rather than a bright centre and a soft edge. Both are printed on the specification table above because they are the things a buyer can check against the pair in their hand.\u003c\/p\u003e\n\n\u003ch2\u003eWhen should a clinic buy custom loupes instead of these?\u003c\/h2\u003e\n\u003cp\u003eCustom loupes are built to one person's anatomy, and for one person who will never share them they are a legitimate purchase. What they are not is fast, shared or replaceable: there is a fitting, there is a wait, and a pair that arrives for one clinician cannot be handed to another. Buy custom when the wearer is fixed, the posture is fixed, and the wait is acceptable; buy adjustable when the pair has to work for more than one person or has to arrive this month.\u003c\/p\u003e\n\u003cp\u003eWe would rather say that plainly than pretend adjustability is identical to a custom fit. It is not. It is faster, it works for whoever picks it up, and it can be re-set between clinicians without a lab — which is why clinics standardise on it and single-handed specialists sometimes do not. If you are the only person who will ever wear the pair and your posture is settled, the custom route is the better answer and we will tell you so.\u003c\/p\u003e\n\u003ch2\u003eTwo constructions, same magnification: how do you tell which one you are buying?\u003c\/h2\u003e\n\u003cp\u003eLoupes are built in two ways, and the difference shows up at the chair long before it shows up on a spec sheet. Nothing on this page depends on knowing the name of either construction; what matters is what each one does to the field, the weight and the path of the light.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe lighter construction.\u003c\/strong\u003e Two lens elements, the lighter of the two, a wide field for its magnification and a shorter working distance. It is the usual answer at 2.5×, and it is what most compact flip-up pairs on the market are.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe folded construction.\u003c\/strong\u003e A telescope with extra elements that fold the light path. It is the usual answer above 3.5×, it holds the edge of the field straighter at higher power, and it is what allows the path to be turned downward in an angled pair. The price of that is weight and money.\u003c\/p\u003e\n\u003cp\u003eAt 3.5× the two overlap on paper, which is why two 3.5× pairs can look identical in a catalogue and feel different at the chair. This page is the lighter construction: a wide field for 2.5×, and it hinges up out of the way between patients.\u003c\/p\u003e\n\u003cp\u003eThree questions separate them in practice: what magnification do you actually need, whether you need the light path turned down toward the site, and what you can wear for a full day. This page answers the first and the third. The angled pairs answer the second, on the \u003ca href=\"\/en-us\/products\/clinieco-ergo-angled-dental-loupes-3-5x-adjustable-pd\"\u003eErgo Angled 3.5× page\u003c\/a\u003e and the \u003ca href=\"\/en-us\/products\/clinieco-ergo-angled-dental-loupes-3-5x-with-wireless-headlight\"\u003eangled set with the wireless headlight\u003c\/a\u003e.\u003c\/p\u003e\n","brand":"CliniEco Medical","offers":[{"title":"S · 280–380 mm","offer_id":49019952529630,"sku":"CLI-LOUPE-25","price":329.0,"currency_code":"CAD","in_stock":true},{"title":"R · 360–460 mm","offer_id":49457055826142,"sku":"CLI-LOUPE-25-R","price":329.0,"currency_code":"CAD","in_stock":true},{"title":"L · 440–540 mm","offer_id":49457055858910,"sku":"CLI-LOUPE-25-L","price":329.0,"currency_code":"CAD","in_stock":true},{"title":"XL · 500–600 mm","offer_id":49457055891678,"sku":"CLI-LOUPE-25-XL","price":329.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CLI-LOUPE-25-HERO-v3-20261117.jpg?v=1794951952"},{"product_id":"clinieco-flip-up-dental-loupes-3-5x-magnification-adjustable-lightweight","title":"CliniEco Prism Flip-Up Dental Loupes — 3.5× Magnification, Adjustable, Lightweight","description":"\u003ch3\u003eFor the work where you need to see one thing very clearly\u003c\/h3\u003e\n\u003cp\u003e3.5× is the magnification for endodontics, surgical work and detailed restorative procedures — the moments when you are looking at a single tooth or a single site and the surrounding arch is not what matters.\u003c\/p\u003e\n\u003cp\u003eChoosing between frames? The \u003ca href=\"\/en-us\/products\/clinieco-ergo-angled-dental-loupes-3-5x-adjustable-pd\"\u003eangled 3.5× loupes\u003c\/a\u003e show the same magnified view from a different posture, and the \u003ca href=\"\/en-us\/products\/clinieco-flip-up-dental-loupes-2-5x-magnification-adjustable-lightweight\"\u003e2.5× flip-up loupes\u003c\/a\u003e give the wider view in this same frame when detail at one site is not what your day needs.\u003c\/p\u003e\n\u003cp\u003eIt is the same frame, the same adjustability and the same flip-up mount as our 2.5×. What changes is the optics: more magnification, and a correspondingly smaller field of view. Read the trade-off section below before you choose between the two, because the higher number is not automatically the right purchase.\u003c\/p\u003e\n\n\n\u003ch3\u003eSpecifications you can hold us to\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eMagnification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e3.5× Magnification, multi-coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eField of view\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eConfirmed for the working distance you order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eWorking distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eSelectable — five settings: 340 \/ 420 \/ 460 \/ 500 \/ 550 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eMount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eFlip-up, adjustable declination, clip mount (opens to 15 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eFrame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eTitanium wire frame, matte black, approx. 70 g incl. optics\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eField of view 80 mm; 88 g with the frame. In the box\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eLoupes, protective case, microfibre cloth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eImporter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eCliniEco Medical — Health Canada MDEL #35334\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eAdjustable interpupillary distance\u003c\/strong\u003e — one frame fits different users, no custom lab work.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eAdjustable declination with flip-up optics\u003c\/strong\u003e — lift the lenses out of the way between patients without removing the frame.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eMulti-coated optics\u003c\/strong\u003e — bright, high-contrast, low-distortion image across the field.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eFive selectable working distances\u003c\/strong\u003e — 340 \/ 420 \/ 460 \/ 500 \/ 550 mm.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eClip mount (opens to 15 mm)\u003c\/strong\u003e — fits the CliniEco Wireless Headlight and most standard loupe lights.\u003c\/p\u003e\n\n\u003ch3\u003eWhich one to choose, and the trade-off nobody explains\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHigher magnification means a smaller field of view. That is physics, not a product limitation.\u003c\/strong\u003e Our 2.5× gives the wider view and our 3.5× a correspondingly narrower one at the same working distance; the exact figure is confirmed for the working distance you order. More detail, less context in the frame. Choose the magnification that matches the work, not the biggest number on the page.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/custom-fitted-vs-adjustable-flip-up-dental-loupes\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/04_barrel_hinge_407b8a97-68dd-4115-838e-519e9d341d40.png?v=1790374798\" alt=\"CliniEco Flip-Up Dental Loupes — 3.5× Magnification, Adjustable, Lightweight\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\u003ch2\u003eShould you choose 3.5× or 2.5× loupes?\u003c\/h2\u003e\n\u003cp\u003e• \u003cstrong\u003e2.5×\u003c\/strong\u003e — general dentistry, hygiene, restorative. You can see most of an arch without repositioning, which is what you want when you are working across a quadrant.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e3.5×\u003c\/strong\u003e — endodontics, surgical and detailed restorative work, where you are looking at one tooth or one site closely and do not need the surrounding view.\u003c\/p\u003e\n\u003ch3\u003eWorking distance: the setting that decides whether loupes work for you\u003c\/h3\u003e\n\u003cp\u003eEach pair offers five selectable working distances — \u003cstrong\u003e340 mm, 420 mm, 460 mm, 500 mm and 550 mm\u003c\/strong\u003e. Pick the wrong one and you will be straining or sitting badly, no matter how good the optics are.\u003c\/p\u003e\n\u003ch2\u003eWhich working distance do you need — 340, 420, 460, 500 or 550 mm?\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMeasure it before you order.\u003c\/strong\u003e Sit or stand the way you actually work, close your eyes, let your arms drop naturally, then open your eyes and have someone measure from your eyes to your hands. That distance is the one to order. Most clinicians land at 450 mm; shorter clinicians and those who work seated close often need the short band, 280–380 mm; taller clinicians working over a standing patient often need the long or extra-long band, 440–600 mm. If you are unsure, tell us your height and whether you work seated or standing, and we will tell you which one we would pick.\u003c\/p\u003e\n\u003ch3\u003eWhy these are adjustable rather than custom-made — and when that is the wrong answer for you\u003c\/h3\u003e\n\u003cp\u003eCustom loupes are made to one person's anatomy. They are excellent, and if you are the only person who will ever wear them and you are willing to wait several weeks and pay for the fitting, they are a reasonable purchase. What they are not is fast, shared, or replaceable.\u003c\/p\u003e\n\u003ch2\u003eHow do adjustable loupes compare with custom loupes?\u003c\/h2\u003e\n\u003cp\u003eOurs take the other route: \u003cstrong\u003eadjustable interpupillary distance and adjustable declination on a flip-up mount\u003c\/strong\u003e, ready to use out of the box. There is no fitting appointment and no multi-week wait. The flip-up optics lift out of the way between patients without removing the frame, which matters when you are moving between magnification and unaided work all day.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere we would tell you to go custom instead:\u003c\/strong\u003e if you have a strong preference for a fixed, individually-fitted declination angle and you know your working posture will never change, a custom pair will feel better than any adjustable pair. We would rather say that than pretend adjustability is identical to a custom fit. It is not. It is faster, cheaper, and it works for anyone who picks them up — which is why clinics standardise on them.\u003c\/p\u003e\n\u003ch3\u003eWhat they mount to\u003c\/h3\u003e\n\u003ch2\u003eDo these loupes fit a dental headlight?\u003c\/h2\u003e\n\u003cp\u003eThe clip mount fits our CliniEco Wireless Headlight and most standard loupe lights, so you are not tied to one brand of light. The frame is titanium wire frame at approximately \u003cstrong\u003e70 g including optics\u003c\/strong\u003e — light enough that the weight is not what you notice after an hour.\u003c\/p\u003e\n\u003ch3\u003eIn the box\u003c\/h3\u003e\n\u003cp\u003eLoupes, protective case, microfibre cloth.\u003c\/p\u003e\n\u003ch3\u003eWhat we can state plainly\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eThe optics are multi-coated\u003c\/strong\u003e — bright, high-contrast and low-distortion across the field. We name the type rather than saying \"high quality optics\".\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eSelectable working distance is five settings\u003c\/strong\u003e (340 \/ 420 \/ 460 \/ 500 \/ 550 mm), not a continuous adjustment. Know which one you need before ordering.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eWe will tell you if the wrong magnification or working distance is what you are about to buy.\u003c\/strong\u003e Send us what you do and how you sit or stand, and we will answer honestly, including telling you to choose the other model.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eImporter of record:\u003c\/strong\u003e Ecology Source New Energy Technology Co., LTD. o\/a CliniEco Medical, Health Canada MDEL #35334. Ships from Toronto, Ontario.\u003c\/p\u003e\n\n\u003ch2\u003eStraight flip-up or angled — which one matches the way you sit?\u003c\/h2\u003e\n\u003cp\u003eMagnification is the number most buyers compare first, but it is not the first decision. The first decision is where the optics point, because that fixes the posture you hold for a whole appointment. On a straight flip-up frame the optics look straight ahead of your eyes, so bringing a lower tooth into that line means tipping your head down and keeping it there. On an angled frame the optical path is turned downward by approximately 45 degrees inside the barrel: the magnified image leaves the eyepiece roughly level and arrives at the work from below, so your head stays closer to upright for the same view. Both are 3.5× — the angle changes your posture, not the detail you can see.\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px;text-align:left\"\u003eWhat changes\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px;text-align:left\"\u003eStraight flip-up (this listing)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px;text-align:left\"\u003eAngled\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eStraight barrel; the optical path leaves the eyepiece straight ahead, with no bend\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eAngled barrel; the optical path is turned downward by about 45° inside the housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eLine of sight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eYour usual horizontal line of sight; the head tips forward to reach the lower arch\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eLeaves the eyepiece roughly level and meets the work about 45° below it; the head stays closer to upright\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eProcedures it suits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eExamination, charting, hygiene and restorative work that moves around the arch\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eEndodontics, surgical work and margins that keep you at one site for a long appointment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eMagnification offered\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e2.5× and 3.5× in the same frame\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e3.5×\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003ePrice tier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eCAD $699 for the 3.5× on this page; CAD $959 as a set with the Core headlight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eCAD $1,099; CAD $1,649 as a set with the headlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eHeadlight compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eClip mount that opens to 15 mm; takes the Core and the Pro headlight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eSame clip mount; the same two headlights fit without an adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eInterpupillary distance and declination adjustable by the wearer; no fitting visit\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eInterpupillary distance adjustable by the wearer; the barrel angle is set by the design, not adjusted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eNeither answer is the better purchase in the abstract, which is why both are listed. If your day is examination, charting, hygiene and restorative work that moves around the arch, the straight frame keeps your usual line of sight, and the same frame is offered in 2.5× when a wider view matters more than detail. If your day is endodontics, surgical work or margins that keep you at one site for a long appointment, the angled frame is the one built around that posture. It sits in a higher price tier because the frame and its optics cost more to make — not because it magnifies more.\u003c\/p\u003e\n\n\u003ch2\u003eWhat are the specifications, and what does each one change at the chair?\u003c\/h2\u003e\n\u003cp\u003eA specification is only worth listing if you can see what it does to your working day. These are the six that decide the purchase, with the consequence next to each one rather than in a footnote at the bottom of the page.\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px;text-align:left\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px;text-align:left\"\u003eThis listing\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px;text-align:left\"\u003eWhat it changes for you\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eMagnification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e3.5×, multi-coated optics\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eDetail at the cost of context in the frame; 2.5× is the wider companion listing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eWorking distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eFive settings — 340 \/ 420 \/ 460 \/ 500 \/ 550 mm, one chosen at order\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eDecides whether you sit naturally or compensate by leaning in all day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eField of view\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eConfirmed for the working distance you order\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eIt follows the setting rather than being one fixed number, so it is answered for your pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eApproximately 70 g including optics\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eThe figure you feel on the bridge of the nose by the end of a long day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eInterpupillary distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eAdjustable by the wearer on the frame\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eNo impression, no lab work and no fitting appointment; one pair can be shared in a practice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003e\u003cstrong\u003eHeadlight interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eClip mount opening to 15 mm; grips a frame bridge about 5 mm across\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eDecides which light will actually sit on this frame, before you buy one\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eTwo of those rows are the ones buyers most often get wrong. Working distance is not a quality setting — it is the distance your eyes naturally sit from the site when you sit the way you work, and a setting that does not match is compensated for by leaning in or sitting back, appointment after appointment. Interpupillary distance is adjusted on the frame itself, which is why there is no impression and no fitting visit, and why the same pair can be handed between two clinicians.\u003c\/p\u003e\n\n\u003ch2\u003eWhich procedures suit 3.5×, and when is 2.5× the better order?\u003c\/h2\u003e\n\u003cp\u003e3.5× is bought for a single site seen closely. Endodontic access and canal work, surgical procedures, and the margins of a detailed restoration are the cases it was chosen for. What it does not do is keep the whole arch in the picture, and no frame can give that back at this magnification.\u003c\/p\u003e\n\u003cp\u003eStay at 2.5× if most of your day is examination, charting, prophylaxis or light restorative work across adjacent teeth, where repositioning between teeth costs more time than the extra detail saves. The two magnifications share a frame, a mount and a working-distance system, so the decision is about your day and not about which product is newer. If you are buying a first pair for a new graduate, 2.5× is usually the easier place to start — that is also what we tell clinics that ask us to fit a whole team.\u003c\/p\u003e\n\n\u003ch2\u003eWhat do we need from you before the order ships?\u003c\/h2\u003e\n\u003cp\u003eFour answers settle the order, and three of them cannot be changed afterwards without a new pair of loupes. Write them into the order note, or send them to us and we will confirm them in writing before anything ships from Toronto.\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse\"\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px;text-align:left\"\u003eWhat we ask\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd;padding:6px;text-align:left\"\u003eWhy it changes the order\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eYour working distance, measured eye to hands\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eIt is built into the pair at the factory; it cannot be adjusted at the chair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eWhether you work seated or standing\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eIt is the second half of the distance answer, and it is the question most buyers cannot answer alone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eWhether you already own a headlight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eThe clip opens to 15 mm; if your light uses a different mount, that is a question for us before the order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eThe procedures you do most\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:6px\"\u003eIt is how we tell you that the magnification you picked is the wrong purchase — including when the answer is 2.5×\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eImporter of record: Ecology Source New Energy Technology Co., LTD. o\/a CliniEco Medical, Health Canada MDEL #35334. The loupes ship from Toronto, Ontario, and the clip mount takes the \u003ca href=\"\/en-us\/products\/clinieco-wireless-dental-headlight-core-35k-lux-ultra-light-for-loupes\"\u003eCore wireless headlight\u003c\/a\u003e or the Pro without an adapter. If you want the angled version of the same 3.5× optics, that is the \u003ca href=\"\/en-us\/products\/clinieco-ergo-angled-dental-loupes-3-5x-adjustable-pd\"\u003eErgo angled 3.5× listing\u003c\/a\u003e; if you want the wider view in the same frame, it is the \u003ca href=\"\/en-us\/products\/clinieco-flip-up-dental-loupes-2-5x-magnification-adjustable-lightweight\"\u003e2.5× flip-up\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003c!-- CROSSLINK-C-GROUP-20260926 --\u003e\n\u003ch3\u003eRelated in this range\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-us\/products\/clinieco-flip-up-dental-loupes-2-5x-magnification-adjustable-lightweight\"\u003eCliniEco Flip-Up Dental Loupes — 2.5×\u003c\/a\u003e — Wider field of view, easier for longer sessions.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/en-us\/products\/clinieco-wireless-dental-headlight-core-35k-lux-ultra-light-for-loupes\"\u003eCliniEco Wireless Dental Headlight — Core, 32K Lux\u003c\/a\u003e — Mounts on these loupes.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/products\/clinieco-flip-up-dental-loupes-2-5x-with-wireless-headlight-set\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/10_scene_4aaa16c5-ef78-4b6a-990f-e34175cbfdd0.png?v=1790546842\" alt=\"clinieco flip up dental loupes 2 5x with wireless headlight set\" loading=\"lazy\" width=\"480\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eChoosing between 2.5× and 3.5× magnification\u003c\/h3\u003e\u003cp\u003e3.5× narrows the field of view for endodontic work and fine margins. If charting and light restorative work are the bulk of your day, the wider field of view of the \u003ca href=\"\/en-us\/products\/clinieco-flip-up-dental-loupes-2-5x-magnification-adjustable-lightweight\"\u003e2.5× flip-up dental loupes\u003c\/a\u003e is the usual choice, and the same frames accept the \u003ca href=\"\/en-us\/products\/clinieco-wireless-dental-headlight-core-35k-lux-ultra-light-for-loupes\"\u003e32k lux wireless headlight\u003c\/a\u003e. Working distance, declination angle and light output are covered in our \u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/where-to-buy-flip-up-dental-loupes-dental-clinics-canada\"\u003eguide to buying flip-up dental loupes for Canadian clinics\u003c\/a\u003e.\u003c\/p\u003e\n\n\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/where-to-buy-dental-ultrasonic-cleaner-dental-clinics-nova-scotia\"\u003eWhere to Buy Dental Ultrasonic Cleaner for Dental Clinics in Nova Scotia\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTwo constructions, same magnification: how do you tell which one you are buying?\u003c\/h2\u003e\n\u003cp\u003eLoupes are built in two ways, and the difference shows up at the chair long before it shows up on a spec sheet. Nothing on this page depends on knowing the name of either construction; what matters is what each one does to the field, the weight and the path of the light.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe lighter construction.\u003c\/strong\u003e Two lens elements, the lighter of the two, a wide field for its magnification and a shorter working distance. It is the usual answer at 2.5×, and it is what most compact flip-up pairs on the market are.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe folded construction.\u003c\/strong\u003e A telescope with extra elements that fold the light path. It is the usual answer above 3.5×, it holds the edge of the field straighter at higher power, and it is what allows the path to be turned downward in an angled pair. The price of that is weight and money.\u003c\/p\u003e\n\u003cp\u003eAt 3.5× the two overlap on paper, which is why two 3.5× pairs can look identical in a catalogue and feel different at the chair. This page is the flip-up construction: straight barrel, hinges up between patients, about 70 g with the optics.\u003c\/p\u003e\n\u003cp\u003eThree questions separate them in practice: what magnification do you actually need, whether you need the light path turned down toward the site, and what you can wear for a full day. This page answers the first and the third. The angled pair, where the path is turned downward instead of running straight, answers the second, on the \u003ca href=\"\/en-us\/products\/clinieco-ergo-angled-dental-loupes-3-5x-adjustable-pd\"\u003eErgo Angled 3.5× page\u003c\/a\u003e and the \u003ca href=\"\/en-us\/products\/clinieco-ergo-angled-dental-loupes-3-5x-with-wireless-headlight\"\u003eangled set with the wireless headlight\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003c!-- CMP35 --\u003e\n### Both are 3.5×. They are not the same loupe.\n\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eGalilean 3.5×\u003cbr\u003e\u003csmall\u003e$449\u003c\/small\u003e\n\u003c\/th\u003e\n\u003cth\u003ePrism 3.5×\u003cbr\u003e\u003csmall\u003e$699\u003c\/small\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of view\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60–65 mm\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e80 mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField steadiness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNarrows as you tilt your head in\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eHolds its width when you lean in\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-element Galilean\u003c\/td\u003e\n\u003ctd\u003eMulti-element with prism group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoutine exams, hygiene, crown and bridge — the lowest-cost way to get 3.5×\u003c\/td\u003e\n\u003ctd\u003eEndodontics, restorative detail, long sessions where the field must stay put\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eTake the Galilean\u003c\/strong\u003e if you want 3.5× at the lowest price and you work mostly upright.\u003cbr\u003e\n\u003cstrong\u003eTake the Prism\u003c\/strong\u003e if the field has to stay wide and steady while you lean in, or you work at 3.5× for hours at a time.\u003c\/p\u003e\n\n\u003cp\u003e\u003csmall\u003eBoth are flip-up with adjustable interpupillary distance and declination. Working distance is fixed per pair on both.\u003c\/small\u003e\u003c\/p\u003e\n\n\u003c!-- \/CMP35 --\u003e","brand":"CliniEco Medical","offers":[{"title":"340 mm","offer_id":49019952595166,"sku":"CLI-LOUPE-35","price":699.0,"currency_code":"CAD","in_stock":true},{"title":"420 mm","offer_id":49457056612574,"sku":"CLI-LOUPE-35-420","price":699.0,"currency_code":"CAD","in_stock":true},{"title":"460 mm","offer_id":49457056645342,"sku":"CLI-LOUPE-35-460","price":699.0,"currency_code":"CAD","in_stock":true},{"title":"500 mm","offer_id":49457056678110,"sku":"CLI-LOUPE-35-500","price":699.0,"currency_code":"CAD","in_stock":true},{"title":"550 mm","offer_id":49457056710878,"sku":"CLI-LOUPE-35-550","price":699.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/CLI-LOUPE-35-HERO-v3-20261117.jpg?v=1794951962"},{"product_id":"dlab-hb120-s-led-digital-dry-bath-incubator","title":"Biological Indicator Incubator - DLAB HB105-S1 Dry Bath, 20-Well, 56-60 C, 24-Hour Readout","description":"\u003cdiv style=\"border:1px solid #d8e3e6;border-radius:10px;padding:22px 24px;margin:0 0 26px;background:#FFFFFF;\"\u003e\n\u003cp style=\"margin:0 0 8px;font-size:11px;font-weight:700;letter-spacing:.12em;text-transform:uppercase;color:#206270;\"\u003eFOR STERILITY ASSURANCE PROGRAMMES\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/dlab-hb105-s2-dry-bath-incubator-alberta-spd\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/01_hero_front_closed.jpg?v=1793235743\" alt=\"DLAB HB105-S1 Dry Bath Incubator with Lid — 20-Well, 24-Hour Biological Indicator Incubation\" width=\"480\" height=\"480\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2 style=\"margin:0 0 12px;font-size:25px;line-height:1.28;font-weight:700;color:#12303a;\"\u003eLaboratory-grade dry-block incubation, built for the audit rather than the brochure.\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 16px;font-size:15.5px;line-height:1.65;color:#33454e;\"\u003eHolds self-contained biological indicators at 56–60 °C for the full 24-hour readout, with control accuracy of ±0.3 °C from 25 °C to 90 °C and ±0.6 °C from 90 °C to 105 °C, and no water bath to fill, change or contaminate.\u003c\/p\u003e\n\u003cdiv style=\"border-left:4px solid #1f6f5c;background:#f2f8f6;padding:14px 16px;margin:18px 0;\"\u003e\n\u003cp style=\"margin:0;\"\u003e\u003cb\u003eLaunch offer — 50 biological indicators included\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"margin:8px 0 0;\"\u003eEvery incubator in this launch batch ships with \u003cb\u003e50 × 24-hour biological indicators\u003c\/b\u003e (the 50-pack is listed at $109.99). At two indicators per sterilisation cycle that covers 25 cycles — enough to run a full spore-testing month while the machine is new.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cul style=\"margin:0 0 18px;padding-left:20px;font-size:14.5px;line-height:1.75;color:#33454e;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e25–90 °C: ±0.3 °C, 90–105 °C: ±0.6 °C control accuracy; ±0.2 °C uniformity at 37 °C\u003c\/strong\u003e — the temperature stability a sterility assurance file depends on.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne block, 20 wells at 11 mm\u003c\/strong\u003e — sized for standard self-contained vials (8 mm body, 10 mm cap) to ISO 11138-3, not a general-purpose dry bath.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupplied with a 20-well block for 8.8 mm tubes.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecTUVus certified\u003c\/strong\u003e — TÜV Rheinland certificate CU 72205506 0001, tested to UL 61010-1 and CAN\/CSA-C22.2 No. 61010-1-12; FCC Part 15 Subpart B and ICES-001 registrations on file.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;margin:0 0 16px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:9px 10px;background:#F1F6F7;color:#12303a;border-bottom:1px solid #d8e3e6;\"\u003eWhat an auditor asks\u003c\/th\u003e\n\u003cth style=\"text-align:left;padding:9px 10px;background:#F1F6F7;color:#12303a;border-bottom:1px solid #d8e3e6;\"\u003eWhat this unit answers\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 10px;border-bottom:1px solid #eaeff1;\"\u003eWas the indicator held at the required temperature for the whole readout?\u003c\/td\u003e\n\u003ctd style=\"padding:9px 10px;border-bottom:1px solid #eaeff1;\"\u003e56–60 °C held for 24 h, within ±0.3 °C, checked against an optional PT1000 reference probe.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 10px;border-bottom:1px solid #eaeff1;\"\u003eIs the indicator itself traceable?\u003c\/td\u003e\n\u003ctd style=\"padding:9px 10px;border-bottom:1px solid #eaeff1;\"\u003eEvery BI lot ships with a certificate of analysis stating the measured spore population and D-value.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 10px;border-bottom:1px solid #eaeff1;\"\u003eCan you produce the electrical safety documentation?\u003c\/td\u003e\n\u003ctd style=\"padding:9px 10px;border-bottom:1px solid #eaeff1;\"\u003ecTUVus certificate number, standards tested to, and FCC\/ICES registrations — supplied as documents, not as claims.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 10px;\"\u003eWhere is the temperature record kept?\u003c\/td\u003e\n\u003ctd style=\"padding:9px 10px;\"\u003e\n\u003cstrong\u003eOn your own load sheet.\u003c\/strong\u003e The display holds temperature and time, and this unit does not log or export data — we would rather tell you that here than have you find it after delivery.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin:0;font-size:13px;line-height:1.65;color:#5b6b73;\"\u003eThis is a dry-block incubator, not a reader and not a data logger. The result is read visually on the indicator — purple passes, yellow fails.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin:0 0 26px;\"\u003e\n\u003cp style=\"margin:0 0 6px;font-size:15px;color:#33454e;\"\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e DLAB HB105-S1 dry bath incubator with transparent lid\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px;font-size:15px;color:#33454e;\"\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e one block, 20 wells (5 × 4), 11 mm well diameter\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px;font-size:15px;color:#33454e;\"\u003e\u003cstrong\u003eTemperature range:\u003c\/strong\u003e room temperature +5 °C to 105 °C, 0.1 °C display resolution\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px;font-size:15px;color:#33454e;\"\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e 25–90 °C: ±0.3 °C, 90–105 °C: ±0.6 °C; uniformity ±0.2 °C at 37 °C; PT1000 external probe supported\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px;font-size:15px;color:#33454e;\"\u003e\u003cstrong\u003eTimer:\u003c\/strong\u003e 0 min to 99 h 59 min\u003c\/p\u003e\n\u003cp style=\"margin:0;font-size:15px;color:#33454e;\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 3.2 kg with the block fitted\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e this page previously covered the HB120-S (no lid). It now ships as the HB105-S1 with a transparent lid — same programme, same bundle, now 20 wells. Existing orders and links are unaffected.\u003c\/em\u003e\u003c\/p\u003e\u003cdiv class=\"clini-prod-section\" style=\"background:#f0f7ff;border:2px solid #206270;border-radius:10px;padding:16px;\"\u003e \u003ch2 style=\"font-size:1.05rem;color:#206270;margin:0 0 6px;\"\u003e🎁 Buy This Incubator — Get a Free 50-Pack of BIs\u003c\/h2\u003e \u003cp style=\"margin:0;font-size:14px;color:#333;\"\u003eOrder the incubator today and we'll include \u003cstrong\u003e50 spore tests (a $109.99 value)\u003c\/strong\u003e at no charge — start your daily monitoring from day one.\u003c\/p\u003e\n\u003cp style=\"margin:12px 0 0;font-size:14px;\"\u003e\u003ca href=\"https:\/\/clinieco.ca\/cart\/49214013014238:1,48983807688926:1\" style=\"display:inline-block;background:#206270;color:#ffffff;padding:11px 20px;border-radius:6px;text-decoration:none;font-weight:600;\"\u003eAdd incubator + free 50-pack\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"margin:8px 0 0;font-size:12.5px;color:#555;\"\u003eThis button puts both items in your cart — the 50-pack shows at $0 and you pay only for the incubator. If you prefer, add the 50-pack yourself: the discount applies automatically to one 50-pack per order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eDLAB HB105-S1 LED Dry Bath Incubator with Lid — for 24-hour biological indicator incubation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA dry-block incubator built for sterility assurance programmes: hold self-contained biological indicator vials at 56–60 °C for the 24-hour readout, with no water bath and no separate reader to buy.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransparent lid for heat preservation\u003c\/strong\u003e — your vials sit in the block for a full 24 hours, and the lid keeps both the heat in and the dust out. The lid is closed by hand.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne heating block — 20 wells (5 rows × 4 columns)\u003c\/strong\u003e, enough for a day of spore tests plus their controls in a single batch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature uniformity ±0.2 °C at 37 °C\u003c\/strong\u003e, control accuracy ±0.3 °C from 25 °C to 90 °C and ±0.6 °C from 90 °C to 105 °C. Runs from room temperature +5 °C up to 105 °C, with 0.1 °C display resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupports a PT1000 external sensor\u003c\/strong\u003e, so you can read from a reference point rather than the block.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTimer, 0 min to 99 h 59 min\u003c\/strong\u003e — set it and walk away.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecTUVus certified\u003c\/strong\u003e — cTUVus, TÜV Rheinland certificate CU 72205506 0001, tested to UL 61010-1 and CAN\/CSA-C22.2 No. 61010-1-12; FCC Part 15 Subpart B (registration AK 50495998 0001) and ICES-001:2006 (registration AK 50496013 0001). 115 V AC, 50\/60 Hz power supply (North American plug).\u003c\/li\u003e\n\u003cli\u003eOverheating protection. Manufacturer: DLAB Scientific Co., Ltd., Beijing. Sold in Canada by CliniEco Medical, Health Canada establishment licence MDEL #35334.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor biological indicator incubation\u003c\/strong\u003e\u003cbr\u003e\nIntended for steam-cycle biological indicators — Geobacillus stearothermophilus self-contained vials to ISO 11138-3 — incubated between 55 and 60 °C with a 24-hour readout. The 11 mm wells take vials with a body diameter of 8 mm and a cap diameter of 10 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat this unit does, and does not, do\u003c\/strong\u003e\u003cbr\u003e\nThe result is read visually on the indicator itself: the medium stays purple when the cycle passes and turns yellow on a failure. This unit is an incubator, not a reader — it does not interpret fluorescent or rapid-readout indicators, which require a fluorescence reader. It does not record or export data; temperature and time are shown on the LED display and are kept on your daily record sheet.\u003c\/p\u003e\n\u003ch2\u003eWhat does spore testing cost per year with this incubator?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003cth\u003eCost per test\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHB105-S1 dry bath incubator with lid (one-time)\u003c\/td\u003e\n\u003ctd\u003e$499.00\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003e24-hour self-contained biological indicator, 25-pack\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e$69.99\u003c\/td\u003e\n\u003ctd\u003e$2.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDaily monitoring on one sterilizer, 250 tests a year\u003c\/td\u003e\n\u003ctd\u003e$699.90 in indicators\u003c\/td\u003e\n\u003ctd\u003e$2.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFirst-year total for a single sterilizer is $499.00 for the incubator plus $699.90 in indicators, or $1,198.90; with the launch offer at the top of this page the first 50 indicators are included at no charge, which brings the first-year figure to $1,088.91. From the second year the annual cost is the indicators alone. The 250-test line assumes one test on each day the sterilizer is used, five days a week; a site running two sterilizers doubles the indicator line.\u003c\/p\u003e\n\n\u003ch2\u003eWhich biological indicators work in this incubator?\u003c\/h2\u003e\n\u003cp\u003eThis is a dry bath held at 56 to 60 °C for the 24-hour readout, which is the incubation condition self-contained \u003cem\u003eGeobacillus stearothermophilus\u003c\/em\u003e indicators to ISO 11138-3 are designed for. The 11 mm wells take vials with a body diameter of 8 mm and a cap diameter of 10 mm. Rapid-readout indicators — 1-hour, 3-hour and 20-minute fluorescence — are not incubated here; they need their own reader.\u003c\/p\u003e\n\n\u003ch2\u003eHow many indicators fit in one run, and is that enough?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating blocks\u003c\/td\u003e\n\u003ctd\u003eOne block, 20 wells (5 rows × 4 columns)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e11 mm diameter, for 8 mm vial body \/ 10 mm cap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003eRoom temperature +5 °C to 105 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl accuracy\u003c\/td\u003e\n\u003ctd\u003e25–90 °C: ±0.3 °C; 90–105 °C: ±0.6 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUniformity\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C at 37 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer\u003c\/td\u003e\n\u003ctd\u003e0 min to 99 h 59 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal sensor\u003c\/td\u003e\n\u003ctd\u003ePT1000 supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd\u003eAC 115 V, 50\/60 Hz, North American plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLid\u003c\/td\u003e\n\u003ctd\u003eTransparent, hand-closed — keeps heat in and dust out during the run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003ecTUVus, TÜV Rheinland certificate CU 72205506 0001 (UL 61010-1, CAN\/CSA-C22.2 No. 61010-1-12); FCC Part 15 Subpart B, registration AK 50495998 0001; ICES-001:2006, registration AK 50496013 0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTwenty wells take twenty vials in one batch: ten spore tests, each paired with its matching control — the pattern daily monitoring follows on a single sterilizer. A 25-pack therefore runs as two batches, which is why the launch offer ships the 50-pack with this unit. That matters because a 24-hour readout means the block is occupied for the whole day: if the batch does not fit, the results split across two days.\u003c\/p\u003e\n\n\u003ch2\u003eDo I need a reader with this incubator?\u003c\/h2\u003e\n\u003cp\u003eNo. A 24-hour colour-change indicator is read by eye — the medium stays purple when the cycle passes and turns yellow on a failure — and recorded on your daily log. A fluorescence reader is only needed for 1-hour, 3-hour and 20-minute rapid indicators, where the result is a machine reading. This unit does not record or export data; temperature and time are shown on the LED display and copied onto your record sheet — a printable daily log is available at \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003ethe compliance log centre\u003c\/a\u003e. For questions about which monitoring interval applies to your own sterilizers, \u003ca href=\"\/en-us\/pages\/sterilization-compliance-consultation\"\u003esend the question to a sterilization compliance specialist\u003c\/a\u003e and you get a written answer that cites the standard behind it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDocumentation\u003c\/strong\u003e\u003cbr\u003e\nEnglish user manual included, French on request. Manufacturer warranty terms are available on request. Not for household use.\u003c\/p\u003e\n\u003ch2\u003eChoosing the right option for your clinic\u003c\/h2\u003e\n\u003cp\u003eBefore you order, the decisions that actually change the result are well count, temperature band, calibration evidence, and what an incubator you cannot defend costs at audit. The full buyer's guide covers them step by step: \u003ca href=\"https:\/\/clinieco.ca\/blogs\/medical-supply-guide\/how-to-choose-biological-indicator-incubator-canadian-clinic\"\u003eHow to Choose a Biological Indicator Incubator for a Canadian Clinic\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eRelated supplies for the same workflow\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003e24-hour self-contained biological indicators, 25 per pack\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-rapid-reader-4-well-fluorescence-biological-indicator-reader\"\u003e4-well fluorescence biological indicator reader\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/products\/clinieco-24-hour-biological-indicator-incubator-precision-dry-block-15-wells\"\u003eCliniEco 24-hour dry block incubator, 15-well\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"\/en-us\/products\/clinieco-medical-biological-indicator-24h-rapid-readout-25-pack\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/p25_01_main_1500_E2.jpg?v=1793459608\" alt=\"24-hour self-contained biological indicators\" loading=\"lazy\" width=\"480\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/sterilizer-testing-frequency-us-vs-canada-biological-indicator-ordering\"\u003eHow Often Must US vs Canadian Clinics Run Sterilizer Testing? Which Biological Indicator Pack to Order\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/how-often-us-vs-canadian-clinics-sterilizer-testing-incubator-guide\"\u003eHow Often Must US vs Canadian Clinics Run Sterilizer Testing? 24-Hour Biological Indicator Incubator Ordering \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/how-do-i-know-if-my-autoclave-is-working-properly\"\u003eHow do I know if my autoclave is working properly?\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow does a 24-hour incubation run actually work, hour by hour?\u003c\/h2\u003e\n\u003cp\u003eThe run is shorter to describe than it is to get wrong. After the sterilization cycle, each indicator is activated according to the manufacturer's instructions for use, labelled so it can be matched to the sterilizer and the load, stood in the block, and left at incubation temperature for the full readout period. With a 24-hour self-contained indicator that means the block is occupied for a working day, the lid stays on, and the result is read the following day against the unexposed control that was incubated alongside it.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eStage\u003c\/th\u003e\n\u003cth\u003eWhat happens at the unit\u003c\/th\u003e\n\u003cth\u003eWhat is written down\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad\u003c\/td\u003e\n\u003ctd\u003eVials stand in the 20 wells (5 rows × 4 columns, Ø 11 mm), which take an 8 mm vial body with a 10 mm cap\u003c\/td\u003e\n\u003ctd\u003eDate, sterilizer, cycle type and lot code against each position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet the temperature\u003c\/td\u003e\n\u003ctd\u003eThe block is set into the 56–60 °C band for steam indicators; the display reads to 0.1 °C\u003c\/td\u003e\n\u003ctd\u003eSet point, and whether a reference probe was used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRun\u003c\/td\u003e\n\u003ctd\u003eThe timer counts through the readout period — 0 min to 99 h 59 min on this unit — with the transparent lid closed by hand\u003c\/td\u003e\n\u003ctd\u003eStart time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRead\u003c\/td\u003e\n\u003ctd\u003ePurple means no growth and the load releases; yellow means spores survived\u003c\/td\u003e\n\u003ctd\u003eResult, read time, and the control's result\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn a fail\u003c\/td\u003e\n\u003ctd\u003eThe load goes back for re-sterilization and the sterilizer is re-tested before anything in it is released\u003c\/td\u003e\n\u003ctd\u003eThe fail itself, the corrective step and the re-test result\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTwo things about that sequence are worth stating plainly, because they are where an inspection usually lands. The lid is closed by hand and there is nothing that closes it for you, so a run started in a hurry with the lid left off is a run at the wrong temperature. And the block only holds, it does not read: the colour change on the vial is the result, and this unit is not a reader.\u003c\/p\u003e\n\n\u003ch2\u003eHow many vials fit in one run, and when does a result slide to the next day?\u003c\/h2\u003e\n\u003cp\u003eTwenty wells hold twenty vials, and a monitoring day needs two vials per sterilizer — the test and its matching control. That is ten sterilizer-days per batch, which is exactly one sterilizer over ten test days, or two sterilizers over five. A 25-pack therefore takes two batches, because twenty vials fit and five are left over; that leftover is why the 50-pack is the size that ships with this unit rather than the 25.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSterilizers tested per day\u003c\/th\u003e\n\u003cth\u003eVials needed per day\u003c\/th\u003e\n\u003cth\u003eDays one 20-well batch covers\u003c\/th\u003e\n\u003cth\u003eWhat that means for ordering\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e10 test days\u003c\/td\u003e\n\u003ctd\u003eA 25-pack runs as two batches; a 50-pack as five\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e5 test days\u003c\/td\u003e\n\u003ctd\u003eOne week of daily monitoring per batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e3 test days\u003c\/td\u003e\n\u003ctd\u003ePlan the week around the block rather than the block around the week\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4 and up\u003c\/td\u003e\n\u003ctd\u003e8 and up\u003c\/td\u003e\n\u003ctd\u003e2 test days or fewer\u003c\/td\u003e\n\u003ctd\u003eTime to ask whether one block is the right equipment for the room\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWhy this matters more than it sounds: a 24-hour readout occupies the well for the whole period, so a batch that does not fit does not run late — it splits across two days, and the second day's results are a day behind. A room that tests two sterilizers daily should be loading the whole week's worth of work into one batch, not discovering on Thursday that the block has been full since Tuesday.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does the certification cover, and what goes in the file?\u003c\/h2\u003e\n\u003cp\u003eThe electrical documentation is the part of a benchtop incubator that auditors ask for and that most listings do not print. This unit carries cTUVus certification from TÜV Rheinland under certificate CU 72205506 0001, tested to UL 61010-1 and CAN\/CSA-C22.2 No. 61010-1-12, with the EMC registrations below held on file.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eReference\u003c\/th\u003e\n\u003cth\u003eWhat it covers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical safety certification\u003c\/td\u003e\n\u003ctd\u003ecTUVus, TÜV Rheinland certificate CU 72205506 0001\u003c\/td\u003e\n\u003ctd\u003eUL 61010-1 and CAN\/CSA-C22.2 No. 61010-1-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC, United States\u003c\/td\u003e\n\u003ctd\u003eFCC Part 15 Subpart B, registration AK 50495998 0001\u003c\/td\u003e\n\u003ctd\u003eEmissions compliance for the US market\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC, Canada\u003c\/td\u003e\n\u003ctd\u003eICES-001:2006, registration AK 50496013 0001\u003c\/td\u003e\n\u003ctd\u003eEmissions compliance for the Canadian market\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e115 V AC, 50\/60 Hz, North American plug\u003c\/td\u003e\n\u003ctd\u003eThe building supply the unit is rated for\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eDLAB Scientific Co., Ltd., Beijing\u003c\/td\u003e\n\u003ctd\u003eWho built the unit and issues the manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImporter\u003c\/td\u003e\n\u003ctd\u003eCliniEco Medical, Health Canada MDEL #35334\u003c\/td\u003e\n\u003ctd\u003eWho is accountable for it in Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAsk for the certificate and the two registration numbers as documents, not as claims on a listing page — that is the whole point of printing the numbers. The instruction manual ships in English with the unit and in French on request, and the manufacturer's warranty terms are available on request.\u003c\/p\u003e\n\n\u003ch2\u003eHow is the incubation temperature set, and how is it checked?\u003c\/h2\u003e\n\u003cp\u003eThe block runs from room temperature +5 °C up to 105 °C, and steam biological indicators are incubated in the 56–60 °C band, so the set point is a band rather than a single number. The display reads to 0.1 °C and the timer runs to 99 h 59 min, which covers a 24-hour readout with room to spare. The unit also supports a PT1000 external probe, which is the useful part: it lets a practice read from a reference point in the block rather than trusting the set point alone.\u003c\/p\u003e\n\u003cp\u003eWhat the unit does not do is record. There is no logging and no export — the numbers on the LED display are copied onto your own record sheet, which is why the printable logs at the compliance log centre are worth printing before the incubator arrives rather than after. A practice that wants a temperature trace has to keep one; this unit holds the temperature, it does not document it.\u003c\/p\u003e\n\n\u003ch2\u003eWhat this incubator is not\u003c\/h2\u003e\n\u003cp\u003eFour exclusions, each of which sends a buyer somewhere else, and it is quicker to say them here than to discover them after delivery. It is not a reader: 1-hour, 3-hour and 20-minute fluorescence indicators need their own reader and are not incubated here. It is not a data logger. It is not a water bath, so there is nothing to fill, change or spill, and nothing that grows in a tank between runs. And it is not a general-purpose dry bath — the block is drilled for standard self-contained vials to ISO 11138-3, not for tubes of arbitrary size.\u003c\/p\u003e\n\u003cp\u003eThe direct consequence of the first exclusion is the one to plan for: a practice that wants same-shift release needs a rapid-readout system, and a practice that tests daily and releases the next morning is the one this unit is built for.\u003c\/p\u003e\n\n\u003ch2\u003eWho this incubator suits, and who it does not\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSetting\u003c\/th\u003e\n\u003cth\u003eFits?\u003c\/th\u003e\n\u003cth\u003eReason\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolo or small practice, one sterilizer, daily testing\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eTwo vials a day occupies a tenth of the block; the 50-pack ships with the unit for exactly this rhythm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePractice with two sterilizers tested daily\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eFour vials a day, twenty wells, a week of work per batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-site group standardising across rooms\u003c\/td\u003e\n\u003ctd\u003eYes, one per room\u003c\/td\u003e\n\u003ctd\u003eThe unit is a small benchtop box; a shared incubator between rooms means carrying activated vials down a corridor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinic using rapid-readout fluorescence indicators\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eThose need a reader; this block does not interpret them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinic wanting an automated temperature record\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo logging or export — the record is written by hand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWhere it does fit, the first-year cost is one capital line and one consumable line: the incubator once, the indicators every time the box runs out. Spread across a daily-monitoring year the unit is the smaller of the two numbers, which is worth knowing before a practice decides to keep spore-testing by hand and ordering the box that actually documents it later.\u003c\/p\u003e\n\n\u003ch2\u003eWhere should the incubator sit in the reprocessing room?\u003c\/h2\u003e\n\u003cp\u003eIt is a benchtop box of 3.2 kg with the block fitted, and it runs from a standard 115 V AC outlet with a North American plug, so the siting question is about workflow rather than services. Put it where the indicators are activated and where the record is written. A block that lives at the far end of the room from the log sheet is a block whose results get copied down from memory at four o'clock, which is the failure mode a paper record is supposed to prevent.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSiting question\u003c\/th\u003e\n\u003cth\u003eWhat the unit needs\u003c\/th\u003e\n\u003cth\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBench space\u003c\/td\u003e\n\u003ctd\u003eRoom for the footprint plus the hand-closed lid to open and close\u003c\/td\u003e\n\u003ctd\u003eThe lid is operated by hand at the start and end of every run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e115 V AC, 50\/60 Hz, North American plug\u003c\/td\u003e\n\u003ctd\u003eThe unit is supplied as the North American build\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhere the log is kept\u003c\/td\u003e\n\u003ctd\u003eBeside the block, not across the room\u003c\/td\u003e\n\u003ctd\u003eResult, time and lot code are copied off the vials and the display at the end of the run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhere vials are activated\u003c\/td\u003e\n\u003ctd\u003eThe same bench, or the bench next to it\u003c\/td\u003e\n\u003ctd\u003eActivated vials go straight into the block rather than travelling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraffic\u003c\/td\u003e\n\u003ctd\u003eOff the walkway between the sink and the autoclave\u003c\/td\u003e\n\u003ctd\u003eAn incubator is bumped once a month in a busy room, and a knocked block is a lost batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThere is nothing to plumb and nothing to drain, which is the practical advantage of a dry block over a water bath: a bench, a socket and a log sheet are the whole installation.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to check on arrival\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat good looks like\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel and nameplate\u003c\/td\u003e\n\u003ctd\u003eHB105-S1 with the transparent lid, matching the certificate number quoted on this page\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlock\u003c\/td\u003e\n\u003ctd\u003eOne block, 20 wells in 5 rows of 4, Ø 11 mm, seated squarely in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLid\u003c\/td\u003e\n\u003ctd\u003eCloses by hand, sits flush, and does not foul the vial caps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirst run\u003c\/td\u003e\n\u003ctd\u003eSet the block into the 56–60 °C band and confirm the display holds it before the first real batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDocuments\u003c\/td\u003e\n\u003ctd\u003eManual in the carton, certificate and EMC registrations on request, importer details on the label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"DLAB","offers":[{"title":"Default Title","offer_id":49214013014238,"sku":"DLAB-HB105-S1","price":499.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/HB105-S1-HERO-promo50-20261110_e2b9bf73-4800-4710-977d-b4bb450cb83c_e0c85514-64d8-48e1-87c7-783f4b7d0fbb.jpg?v=1794342653"}],"url":"https:\/\/clinieco.ca\/en-us\/collections\/equipment.oembed","provider":"CliniEco Medical","version":"1.0","type":"link"}