{"title":"Diabetes Care","description":"\u003c!-- geo:collbody:20261106:diabetes-care --\u003e\n\u003cp\u003e\u003cstrong\u003eInsulin delivery and capillary blood sampling are two different jobs, and the four listings in this collection split three ways.\u003c\/strong\u003e A pen needle, an insulin syringe and a blood lancet all end in a sharp point, and buyers routinely treat them as one supply line because they arrive in the same diabetes order. They are not substitutes: each one is defined by a different standard, a different gauge geometry and a different job at the point of use. What follows is the specification logic that decides which format belongs on the shelf, and where the used sharp goes afterwards.\u003c\/p\u003e\n\n\u003ch2\u003eAre 32G pen needles, 1 cc 31G syringes and 33G lancets interchangeable?\u003c\/h2\u003e\n\u003cp\u003eNo, and the reason is upstream of the gauge number. A pen needle attaches to a specific insulin pen and is a double-ended, sterile, single-use needle covered by ISO 11608-2:2022, which is written for needles used with needle-based injection systems built to ISO 11608-1. An insulin syringe is a complete delivery device: a barrel, a plunger and an attached needle, covered by ISO 8537:2016, which is written specifically for empty, sterile, single-use plastic syringes intended solely for insulin. A lancet is neither. It is a single-use sterile point for capillary blood, and its job ends with a drop of blood on a strip.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eThe three formats in this collection, side by side\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFormat\u003c\/th\u003e\n\u003cth\u003eGauge and nominal outside diameter\u003c\/th\u003e\n\u003cth\u003eWhat it does\u003c\/th\u003e\n\u003cth\u003eProduct standard\u003c\/th\u003e\n\u003cth\u003ePack\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/insulin-pen-needles-32g-4mm-100-box\"\u003eInsulin pen needle, 32G by 4 mm\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e32G, 0.23 mm\u003c\/td\u003e\n\u003ctd\u003eDelivers insulin from a pen cartridge into subcutaneous tissue\u003c\/td\u003e\n\u003ctd\u003eISO 11608-2:2022, with tubing dimensions from ISO 9626:2016\u003c\/td\u003e\n\u003ctd\u003e100 per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/insulin-syringes-1cc-31g-100-box\"\u003eInsulin syringe, 1 cc with 31G needle\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e31G, 0.25 mm\u003c\/td\u003e\n\u003ctd\u003eDraws insulin from a vial and delivers a measured dose\u003c\/td\u003e\n\u003ctd\u003eISO 8537:2016\u003c\/td\u003e\n\u003ctd\u003e100 per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/sterile-blood-lancets-33g-100-box\"\u003eSterile blood lancet, 33G\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e33G, 0.20 mm\u003c\/td\u003e\n\u003ctd\u003ePunctures skin for a capillary blood drop\u003c\/td\u003e\n\u003ctd\u003eSterile, single use; sterilisation validated to ISO 11135:2014 or the ISO 11137 series\u003c\/td\u003e\n\u003ctd\u003e100 per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/en-us\/products\/clinieco-blood-glucose-monitor-kit-complete-diabetes-testing-kit-with-50-test-strips\"\u003eBlood glucose monitor kit with 50 test strips\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMeter plus strip system\u003c\/td\u003e\n\u003ctd\u003eReads a capillary blood sample against a test strip\u003c\/td\u003e\n\u003ctd\u003eSystem performance under ISO 15197:2013\u003c\/td\u003e\n\u003ctd\u003eKit with 50 strips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhat does the gauge number actually measure, and why does that change the injection?\u003c\/h2\u003e\n\u003cp\u003eGauge is the outside diameter of the cannula, not its bore, and the numbers run in the opposite direction to intuition: 33G is thinner than 32G, which is thinner than 31G. In the ISO 9626:2016 tubing series the nominal outside diameters are 0.20 mm at 33G, 0.23 mm at 32G and 0.25 mm at 31G, against 0.18 mm at 34G and 0.30 mm at 30G. Wall thickness then decides the inner diameter, so two needles both marked 32G can differ in flow and in the force needed to deliver a dose, because a thin-wall and an extra-thin-wall cannula are different products.\u003c\/p\u003e\n\u003cp\u003eLength is a separate variable. Four millimetres on a pen needle reaches subcutaneous fat in most adults, including adults with a higher body mass index, which is why guidance moved away from longer needles as the default. It is not universal: very young children, very lean adults and anyone injecting into a lifted skin fold need a clinical decision, and the technique belongs in the written protocol next to the product code. A 1 cc barrel is chosen for the opposite reason: at small doses the graduations are further apart than on a 3 cc barrel, so the dose is easier to read.\u003c\/p\u003e\n\n\u003ch2\u003eWhich standard should a supplier's test report cite?\u003c\/h2\u003e\n\u003cp\u003eAsk for four documents and the edition of each. For pen needles, ISO 11608-2:2022 covers requirements and test methods for single-use double-ended sterile needles, and ISO 11608-1 covers dose accuracy on the complete system rather than on the needle alone. For insulin syringes, ISO 8537:2016 is the product standard, and it excludes glass syringes, pump syringes and manufacturer-prefilled syringes, so a report citing it tells you which category the product is in. For both, needle tubing dimensions come from ISO 9626:2016. Separately, sterility and the sterile barrier are their own questions: the sterilisation process should be validated to ISO 11135:2014 for ethylene oxide or to the ISO 11137 series for radiation, and the packaging system qualified to ISO 11607-1:2019.\u003c\/p\u003e\n\u003cp\u003eA manufacturer working to ISO 13485:2016 can produce these on request. In Canada, the establishment that distributes the finished device holds a Medical Device Establishment Licence, and CliniEco Medical operates under MDEL #35334. A specification sheet that names the standard and the edition answers most of a procurement review before it begins, and it is the difference between a listing and a documented supply line.\u003c\/p\u003e\n\n\u003ch2\u003eWhere do used pen needles, syringes and lancets go, and how do the rules differ between Canada and the United States?\u003c\/h2\u003e\n\u003cp\u003eEvery sharp in this collection is single use, and disposal is part of the product decision rather than an afterthought. In Ontario, used needles, syringes and lancets are biomedical waste and are segregated at the point of use into a sharps container, under Guideline C-4, the provincial document that sets containment and colour coding for that jurisdiction: sharps waste takes a yellow label carrying the universal biohazard symbol. Other provinces publish their own requirements, so a policy covering sites in more than one province has to name the jurisdiction instead of treating one province's rule as national.\u003c\/p\u003e\n\u003cp\u003eContainer construction is a separate standard from the waste rule. CSA Z316.6:20 sets requirements and test methods for sharps containers, including puncture resistance, closure and resistance to damage after dropping, and it adopts ISO 23907-2:2019 with Canadian requirements added. In the United States the same disposal question is governed by the bloodborne pathogens standard, which requires containers that are closable, puncture resistant, leakproof on the sides and bottom, and labelled or colour-coded.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eSame consumable, two rulebooks: Canada compared with the United States\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eCanada\u003c\/th\u003e\n\u003cth\u003eUnited States\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSharps segregation\u003c\/td\u003e\n\u003ctd\u003eProvincial. In Ontario, Guideline C-4 requires a yellow label with the universal biohazard symbol on sharps waste\u003c\/td\u003e\n\u003ctd\u003eOSHA 29 CFR 1910.1030(d)(4)(iii)(A): closable, puncture resistant, leakproof on sides and bottom, labelled or colour-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSharps container performance\u003c\/td\u003e\n\u003ctd\u003eCSA Z316.6:20, which adopts ISO 23907-2:2019 with Canadian requirements added\u003c\/td\u003e\n\u003ctd\u003eNo single national container standard; the OSHA container properties are the requirement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulin syringe as a device\u003c\/td\u003e\n\u003ctd\u003eDevice under the Medical Devices Regulations; the distributor holds an MDEL (CliniEco Medical: MDEL #35334)\u003c\/td\u003e\n\u003ctd\u003ePiston syringe under 21 CFR 880.5860\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePen needle\u003c\/td\u003e\n\u003ctd\u003eDevice under the Medical Devices Regulations; ISO 11608-2:2022 is the product standard a buyer can specify\u003c\/td\u003e\n\u003ctd\u003eDevice; the same ISO standard is recognised by the FDA for premarket review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlood glucose meter\u003c\/td\u003e\n\u003ctd\u003eDevice licence held by the manufacturer or importer; the distributor holds an MDEL\u003c\/td\u003e\n\u003ctd\u003ePremarket notification required before marketing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eIs an insulin syringe approved for sale in Canada also cleared for sale in the United States?\u003c\/h2\u003e\n\u003cp\u003eNo. Device authorisation is granted market by market. A Medical Device Establishment Licence permits an establishment to distribute devices in Canada; it says nothing about the FDA, and it is not a product approval in either country. In the other direction, an FDA clearance does not authorise Canadian sale: the Canadian importer or distributor still needs an establishment licence, and the manufacturer still needs its own device authorisation in Canada. What does travel is the test evidence. Where the same ISO standard is recognised on both sides the reports can be reused, which is one reason ISO 11608-2:2022 matters commercially as well as technically: it carries FDA recognition number 6-476, so a supplier holding that report is not starting from zero in either market.\u003c\/p\u003e\n\n\u003ch2\u003eShould a clinic standardise on one gauge, or keep two?\u003c\/h2\u003e\n\u003cp\u003eOne gauge per pen model, plus a second size only where a patient population justifies it. Pen needles are not interchangeable between pen models by gauge alone: the hub has to be the one the pen manufacturer's instructions list, and that verification is a document check, not a fit test. Lancets are the opposite case, because the limiting factor is capillary flow rather than device compatibility, and a thinner lancet is usually less painful but needs good perfusion. A clinic that sees cold hands, older patients or low-perfusion fingers often keeps a second lancet size for those appointments, and that is a clinical stock decision rather than a purchasing one.\u003c\/p\u003e\n\u003cp\u003eThe rule that does not bend is single use with no recapping by hand, a sharps container within reach of every injection point, and a documented needlestick procedure. Those three items belong in the same written standard as the product codes, because an audit asks for the procedure, not for the catalogue.\u003c\/p\u003e\n\n\u003ch2\u003eWhat does a complete monitoring kit have to contain, and what does it not replace?\u003c\/h2\u003e\n\u003cp\u003eFour parts: a meter, test strips, a lancing device and lancets. The kit listed here arrives with all four and 50 test strips, so a first reading is possible on the day it is unpacked rather than after a second order for consumables. The meter is the durable part of the system; strips and lancets are the consumables that run out and are replaced, which is why the strip count on the box, not the meter, sets the reorder rhythm. Self-monitoring does not replace laboratory testing: A1C and laboratory results stay in the clinician's plan, and the meter reports a number that the care team interprets.\u003c\/p\u003e\n\u003cp\u003eOne procurement note. Current availability is stated on each product page, and where a format is not currently offered through the online store, the institutional account enquiry page is the route to a lead time and to the documentation package. Specification sheets for institutional orders are available on request.\u003c\/p\u003e\n\n\u003ch2\u003eStandards and sources behind this page\u003c\/h2\u003e\n\u003cp\u003eEditions and links were checked on 6 November 2026. \u003ca href=\"https:\/\/www.evs.ee\/en\/iso-11608-2-2022\"\u003eISO 11608-2:2022, double-ended pen needles\u003c\/a\u003e, with dose accuracy on the system under ISO 11608-1. \u003ca href=\"https:\/\/www.evs.ee\/en\/iso-8537-2016\"\u003eISO 8537:2016, sterile single-use syringes for insulin\u003c\/a\u003e. \u003ca href=\"https:\/\/www.evs.ee\/en\/iso-9626-2016\"\u003eISO 9626:2016, stainless steel needle tubing\u003c\/a\u003e. \u003ca href=\"https:\/\/www.evs.ee\/en\/iso-15197-2013\"\u003eISO 15197:2013, blood-glucose monitoring systems for self-testing\u003c\/a\u003e, which is the current edition with a revision in progress. \u003ca href=\"https:\/\/www.evs.ee\/en\/iso-11135-2014\"\u003eISO 11135:2014, ethylene oxide sterilisation\u003c\/a\u003e. \u003ca href=\"https:\/\/www.evs.ee\/en\/iso-11607-1-2019\"\u003eISO 11607-1:2019, packaging for terminally sterilised devices\u003c\/a\u003e. \u003ca href=\"https:\/\/www.csagroup.org\/store\/product\/CSA%20Z316.6%3A20\/\"\u003eCSA Z316.6:20, sharps containers\u003c\/a\u003e. \u003ca href=\"https:\/\/www.ontario.ca\/page\/c-4-management-biomedical-waste-ontario\"\u003eOntario, Guideline C-4: management of biomedical waste\u003c\/a\u003e. \u003ca href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.1030\"\u003eOSHA 29 CFR 1910.1030, bloodborne pathogens\u003c\/a\u003e. \u003ca href=\"https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfstandards\/detail.cfm?standard__identification_no=43455\"\u003eFDA recognised consensus standard for ISO 11608-2:2022, recognition number 6-476\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eRelated reading\u003c\/h2\u003e\n\u003cp\u003eTwo background pieces on the same supply line: \u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/insulin-pen-needles-sharps-long-term-care-canada\"\u003einsulin pen needles and sharps handling in Canadian long-term care\u003c\/a\u003e, and \u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/which-low-dead-space-syringe-community-health-centres-alberta-sizes-case-formats\"\u003elow dead-space syringes and case formats for community health centres\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eIs a 33G lancet finer than a 32G pen needle?\u003c\/h3\u003e\n\u003cp\u003eYes. Gauge runs in reverse: 33G is 0.20 mm nominal outside diameter and 32G is 0.23 mm, so the lancet is the thinner of the two, even though the two products do different jobs and are not alternatives to each other.\u003c\/p\u003e\n\u003ch3\u003eCan a pen needle be used on any insulin pen?\u003c\/h3\u003e\n\u003cp\u003eNo. The hub has to be one the pen manufacturer's own instructions list for that pen model. Gauge and length are not compatibility information, and a fits-most-pens claim is not a substitute for the pen manufacturer's list.\u003c\/p\u003e\n\u003ch3\u003eDoes the Ontario sharps rule apply across Canada?\u003c\/h3\u003e\n\u003cp\u003eNo. Guideline C-4 is an Ontario document. Other provinces set their own requirements for biomedical waste, so a policy covering several provinces has to name each jurisdiction rather than adopt one rule nationally.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between the syringe and the pen needle standard?\u003c\/h3\u003e\n\u003cp\u003eISO 8537:2016 covers the complete insulin syringe as a product. ISO 11608-2:2022 covers a double-ended sterile pen needle used with a needle-based injection system, and it refers to ISO 11608-1 for dose accuracy on the system rather than on the needle alone.\u003c\/p\u003e\n\u003ch3\u003eWhere does an institutional buyer start?\u003c\/h3\u003e\n\u003cp\u003eWith the specification sheet and the test reports for the exact product code, then the sharps container specification for the site. Volume requirements and multi-site accounts go through the \u003ca href=\"\/en-us\/pages\/wholesale\"\u003einstitutional account enquiry page\u003c\/a\u003e; the \u003ca href=\"\/en-us\/pages\/clinic-supply-planner\"\u003eclinic supply planner\u003c\/a\u003e and the \u003ca href=\"\/en-us\/pages\/compliance-log-center\"\u003ecompliance log centre\u003c\/a\u003e carry the record-keeping side.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDistribution:\u003c\/strong\u003e CliniEco Medical — MDEL #35334. Gauge, length and pack counts are those printed on the current product listings; confirm the specification sheet and the standard edition with the supplier before a tender or an accreditation review.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\n  \"@id\": \"https:\/\/clinieco.ca\/collections\/diabetes-care#faq\",\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Is a 33G lancet finer than a 32G pen needle?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Gauge runs in reverse: 33G is 0.20 mm nominal outside diameter and 32G is 0.23 mm, so the lancet is the thinner of the two, even though the two products do different jobs and are not alternatives to each other.\"}},{\"@type\":\"Question\",\"name\":\"Can a pen needle be used on any insulin pen?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. The hub has to be one the pen manufacturer's own instructions list for that pen model. Gauge and length are not compatibility information, and a fits-most-pens claim is not a substitute for the pen manufacturer's list.\"}},{\"@type\":\"Question\",\"name\":\"Does the Ontario sharps rule apply across Canada?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. Guideline C-4 is an Ontario document. Other provinces set their own requirements for biomedical waste, so a policy covering several provinces has to name each jurisdiction rather than adopt one rule nationally.\"}},{\"@type\":\"Question\",\"name\":\"What is the difference between the syringe and the pen needle standard?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"ISO 8537:2016 covers the complete insulin syringe as a product. ISO 11608-2:2022 covers a double-ended sterile pen needle used with a needle-based injection system, and it refers to ISO 11608-1 for dose accuracy on the system rather than on the needle alone.\"}}]}\u003c\/script\u003e","products":[{"product_id":"clinieco-blood-glucose-monitor-kit-complete-diabetes-testing-kit-with-50-test-strips","title":"CliniEco Blood Glucose Monitor Kit — Complete Diabetes Testing Kit with 50 Test Strips","description":"\u003cdiv class=\"product-description\"\u003e \u003ch2\u003eProduct Overview\u003c\/h2\u003e \u003cp\u003eA meter alone does not test anything — you also need strips, a lancing device, and lancets. This kit arrives with all four parts, including \u003cb\u003e50 test strips\u003c\/b\u003e, so a newly diagnosed patient can take a first reading the day it is delivered rather than waiting on a second order for consumables.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eKey Features:\u003c\/b\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cb\u003eComplete kit\u003c\/b\u003e — meter, 50 test strips, lancing device, and lancets in one box\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003e50 strips included\u003c\/b\u003e — roughly a month of twice-daily monitoring\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eSmall blood sample\u003c\/b\u003e — fingertip testing with the supplied lancing device\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eCompact meter\u003c\/b\u003e — fits a home-care bag or a bedside drawer\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eRefill strips available\u003c\/b\u003e — reorder consumables without replacing the meter\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cb\u003eUse Cases:\u003c\/b\u003e diabetes education programs, home-care nursing visits, family practice teaching for newly diagnosed patients, and long-term care residents on a monitoring schedule. Follow the meter's instructions for test-site preparation.\u003c\/p\u003e \u003cp\u003e\u003cb\u003eCommon questions:\u003c\/b\u003e Does it replace laboratory testing? No — self-monitoring supports day-to-day management; A1C and laboratory testing remain part of a clinician's diabetes plan. What should a reading be? Target ranges are set by the treating clinician and vary by patient; the monitor reports the number, the care team interprets it.\u003c\/p\u003e \u003cp\u003eDistributed by CliniEco Medical. Ask about availability and clinic pricing: \u003ca href=\"\/en-us\/pages\/wholesale\"\u003eRequest a quote →\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c!-- spec-align-20260919 --\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e \u003cstrong\u003eSize \/ Rating:\u003c\/strong\u003e Blood glucose test strips; match to your meter model\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003ePackaging:\u003c\/strong\u003e 50 \/ 100 strips per vial, desiccant included; use within 3 months of opening\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eCompatible with:\u003c\/strong\u003e Lancets (33G), available as a separate SKU\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eFull specification sheet available on request for institutional orders.\u003c\/em\u003e\u003c\/p\u003e\n\u003csection class=\"clinieco-answers\"\u003e\n\u003ch2\u003eWhat comes in a complete blood glucose monitoring kit?\u003c\/h2\u003e\n\u003cp\u003eA complete kit has four parts: a meter, a vial of test strips, a lancing device and lancets. This kit arrives with all four, including 50 test strips, so a first reading is possible on the day it is unpacked instead of waiting to re-source consumables. The meter is the durable part of the system; strips and lancets are the consumables that run out and get replaced.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeter:\u003c\/strong\u003e One per kit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest strips:\u003c\/strong\u003e 50 strips, one vial with desiccant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLancing device:\u003c\/strong\u003e One per kit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLancets:\u003c\/strong\u003e Matched to 33G, separate SKU\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests per day:\u003c\/strong\u003e Strips per 28 days\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMarket authorisation:\u003c\/strong\u003e Health Canada medical device licence under SOR\/98-282\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeter:\u003c\/strong\u003e One per kit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest strips:\u003c\/strong\u003e 50 strips, one vial with desiccant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLancing device:\u003c\/strong\u003e One per kit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLancets:\u003c\/strong\u003e Matched to 33G, separate SKU\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests per day:\u003c\/strong\u003e Strips per 28 days\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMarket authorisation:\u003c\/strong\u003e Health Canada medical device licence under SOR\/98-282\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003ePackaging \/ quantity\u003c\/th\u003e\n\u003cth\u003eUnit basis\u003c\/th\u003e\n\u003cth\u003eTypical setting\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter\u003c\/td\u003e\n\u003ctd\u003eOne per kit\u003c\/td\u003e\n\u003ctd\u003ePer device\u003c\/td\u003e\n\u003ctd\u003eHome care, clinic teaching room\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest strips\u003c\/td\u003e\n\u003ctd\u003e50 strips, one vial with desiccant\u003c\/td\u003e\n\u003ctd\u003eOne strip per reading\u003c\/td\u003e\n\u003ctd\u003eTwice-daily self-monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLancing device\u003c\/td\u003e\n\u003ctd\u003eOne per kit\u003c\/td\u003e\n\u003ctd\u003ePer device\u003c\/td\u003e\n\u003ctd\u003eSingle-patient use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLancets\u003c\/td\u003e\n\u003ctd\u003eMatched to 33G, separate SKU\u003c\/td\u003e\n\u003ctd\u003eOne lancet per reading\u003c\/td\u003e\n\u003ctd\u003eClinic or home\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHow many test strips does a monitoring schedule use in a month?\u003c\/h2\u003e\n\u003cp\u003eSize the strip quantity from the schedule, not from the vial size. At two tests a day, 50 strips cover about 25 days; at four tests a day, about 12 days. Strips are single-use, and the desiccant in the vial only protects them until the vial is opened — the specification on this page states use within three months of opening.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTests per day\u003c\/th\u003e\n\u003cth\u003eStrips per 28 days\u003c\/th\u003e\n\u003cth\u003eVials per month at 50 per vial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003ctd\u003eAbout 1.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e112\u003c\/td\u003e\n\u003ctd\u003eAbout 2.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e196\u003c\/td\u003e\n\u003ctd\u003eAbout 3.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhich lancets fit this kit, and what does the gauge number mean?\u003c\/h2\u003e\n\u003cp\u003eThis kit is matched to 33G lancets, listed as a separate item. Gauge is the nominal outer diameter of the lancet: ISO 9626:2016 lists 33G at 0.20 mm, 32G at 0.23 mm, 31G at 0.25 mm and 30G at 0.30 mm. A higher gauge is thinner, which most patients find more comfortable, but it also yields a smaller drop of blood — the sample volume the meter states is the limit to work within.\u003c\/p\u003e\n\u003ch2\u003eHow is a blood glucose system regulated in Canada compared with the United States?\u003c\/h2\u003e\n\u003cp\u003eCanada and the United States authorise a glucose system through different routes, and the difference that matters to a clinic is the lancing device. Health Canada's notice of 26 September 2014 (File 14-111696-560) states that lancing devices for use on more than one patient must be self-disabling or single-patient use, because a spring-loaded device can draw blood back into the housing even when the lancet is changed. The notice followed a 2012 event in Canada in which 72 people were notified after shared lancing.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eCanada\u003c\/th\u003e\n\u003cth\u003eUnited States\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarket authorisation\u003c\/td\u003e\n\u003ctd\u003eHealth Canada medical device licence under SOR\/98-282\u003c\/td\u003e\n\u003ctd\u003eClass II, 21 CFR 862.1345 (glucose test system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-patient lancing\u003c\/td\u003e\n\u003ctd\u003eSelf-disabling or single-patient use (File 14-111696-560)\u003c\/td\u003e\n\u003ctd\u003eSingle use as labelled by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrip vial marking\u003c\/td\u003e\n\u003ctd\u003eLot and expiry on the vial\u003c\/td\u003e\n\u003ctd\u003eLot and expiry on the vial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhat a clinic files\u003c\/td\u003e\n\u003ctd\u003eLicence number with the product record\u003c\/td\u003e\n\u003ctd\u003e510(k) number with the product record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor institutional supply of meters, strips and lancets, see the \u003ca href=\"\/en-us\/pages\/wholesale\"\u003einstitutional account enquiry page\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eLast reviewed: 2026-11\u003c\/em\u003e\u003c\/p\u003e\u003c\/section\u003e\n\u003ch3\u003eRelated articles\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/blood-glucose-monitor-kit-everything-you-need-for-accurate-diabetes-management-at-home\"\u003eBlood Glucose Monitor Kit: Everything You Need for Accurate Diabetes Management at Home\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/diabetes-management-supplies-canadian-patients-glucometers-test-strips\"\u003eDiabetes Management Supplies for Canadian Patients: Glucometers, Test Strips, Lancets, and Continuous Monitoring\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/blood-glucose-monitor-procurement-for-canadian-clinics-testing-kits-and-compliance\"\u003eBlood Glucose Monitor Procurement for Canadian Clinics: Testing Kits and Compliance\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"CliniEco Medical","offers":[{"title":"Default Title","offer_id":48409412665566,"sku":"CLI-BG-001","price":39.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/6d2d7314bff63929dd0bdaecdcab2aeb.png?v=1786473528"},{"product_id":"insulin-syringes-1cc-31g-100-box","title":"Insulin Syringes 1 cc — 31G × 5\/16\", 100\/Box","description":"\u003cp\u003eInsulin syringes with a 1 mL barrel and a 31 gauge needle, supplied 100 per box. The 1 mL barrel with half-unit or unit graduations is the format used for the smallest doses, where a larger barrel would make the dose hard to read.\u003c\/p\u003e\n\u003cp\u003eThis page documents the specification, sizing logic and sourcing position for these syringes for Canadian clinics, pharmacies, diabetes education programs and care homes.\u003c\/p\u003e\n\u003ch2\u003eWho it is for\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDiabetes education and outpatient clinics\u003c\/li\u003e\n\u003cli\u003eCommunity pharmacies running injection programs\u003c\/li\u003e\n\u003cli\u003eLong-term care homes administering insulin\u003c\/li\u003e\n\u003cli\u003ePublic health and travel clinics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBarrel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mL with fine graduations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeedle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31G, short bevel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntended use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulin administration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecification listing — availability pending supplier documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhy does syringe barrel size matter for insulin?\u003c\/h3\u003e\n\u003cp\u003eDose accuracy. A 1 mL barrel gives more space between graduations than a 3 mL barrel, so small doses are easier to read — which is also why insulin is commonly supplied in dedicated 0.3 mL, 0.5 mL and 1 mL formats.\u003c\/p\u003e\n\u003ch3\u003eWhat does 31G mean?\u003c\/h3\u003e\n\u003cp\u003eNeedle gauge, or outside diameter: 31G is thinner than 29G or 30G, which usually means less injection discomfort. Thin needles require more care with injection technique.\u003c\/p\u003e\n\u003ch3\u003eCan facilities buy syringes without a prescription?\u003c\/h3\u003e\n\u003cp\u003eIn Canada, the licensing classification of the device determines what documentation a supplier must hold. This listing is being prepared against that requirement; pricing and ordering will be enabled once it is complete.\u003c\/p\u003e\n\u003ch3\u003eHow do I ask about volume supply?\u003c\/h3\u003e\n\u003cp\u003eUse our B2B enquiry form. We will confirm documentation status and lead times.\u003c\/p\u003e\n\u003ch2\u003eWhat do 1 cc, 31G and 5\/16 inch each specify?\u003c\/h2\u003e\n\u003cp\u003eThree numbers, three different jobs. One cc is one millilitre of barrel capacity, and on a U-100 scale that barrel holds 100 units, so each unit is one hundredth of the barrel. 31G is the needle's outside diameter: 0.25 mm in the ISO 9626:2016 designated size series, finer than 30G at 0.30 mm and coarser than 32G at 0.23 mm. Five sixteenths of an inch is 7.94 mm of needle length, a short needle that reaches subcutaneous fat in most adults. The barrel is the part that decides dose accuracy, because graduation spacing shrinks as capacity grows: a 1 mL barrel leaves visibly more space between marks than a 3 mL barrel for the same dose. That is why insulin is drawn in 0.3, 0.5 or 1 mL formats rather than in whatever general-purpose syringe is nearest to hand.\u003c\/p\u003e\n\u003ch2\u003eWhich standard covers an insulin syringe, and which one does not?\u003c\/h2\u003e\n\u003cp\u003eISO 8537:2016 is the document written for this device: sterile, single-use syringes, with or without needle, intended solely for the injection of insulin and filled by the end user. ISO 7886-1:2017, the general standard for manual single-use hypodermic syringes, states in its scope that it excludes syringes for use with insulin and points instead to ISO 8537. A supplier sheet that cites only ISO 7886-1 for an insulin syringe is citing the wrong document, even when the same factory makes both product lines. Tubing dimensions come from ISO 9626:2016, sterilisation from ISO 11135:2014 or the ISO 11137 series, the sterile barrier from ISO 11607-1:2019, and the manufacturer's quality system should be certified to ISO 13485:2016. Both were confirmed as current at their last review, and both have a replacement in progress at ISO, so the edition belongs on the specification sheet.\u003c\/p\u003e\n\u003ch2\u003eWhy does the concentration on the vial have to match the scale?\u003c\/h2\u003e\n\u003cp\u003eA U-100 vial contains 100 units of insulin per millilitre, the concentration used for almost all human insulin supplied in Canada. Higher-strength products, U-200 and U-300, are supplied in pens built for that concentration. Drawing a U-200 or U-300 product into a U-100 syringe multiplies the intended dose by two or three, turning a 10-unit dose into 20 or 30 units with no visible change on the scale. Keep the vial and the syringe in the same conversation: a U-100 syringe is for U-100 insulin, and any product supplied in a pen stays in its pen. If a clinic holds more than one concentration, store them apart and label the shelf, not only the carton.\u003c\/p\u003e\n\u003ch2\u003eHow much insulin stays in the syringe after the plunger is fully depressed?\u003c\/h2\u003e\n\u003cp\u003eSome volume always remains in the hub and the needle, and no amount of plunger pressure moves it. That residual is a design property of the syringe, so it should be a stated number in millilitres rather than a figure a buyer estimates from a drawing. It matters most at the small end: a 2-unit dose from a syringe with a large hub residual delivers proportionally less insulin than a 20-unit dose from the same syringe. Ask for the measured residual volume and the method used to obtain it, and write it beside the product code in the protocol, because one clinic can hold two syringe brands with different hubs and one shared procedure.\u003c\/p\u003e\n\u003ch2\u003eWhat belongs in the batch record and the clinic protocol?\u003c\/h2\u003e\n\u003cp\u003eSingle use with no recapping by hand; a sharps container within reach at every injection point; gloves changed between patients when staff give the injection; storage that keeps the carton dry and away from direct heat; and lot traceability from receipt through to the patient record. Waste is provincial: in Ontario, human blood waste is listed in Table A of guideline C-4 with a yellow label and the universal biohazard symbol, while other provinces publish their own rules for the same stream. Our \u003ca href=\"\/en-us\/products\/sterile-blood-lancets-33g-100-box\"\u003e33G blood lancets\u003c\/a\u003e, \u003ca href=\"\/en-us\/products\/insulin-pen-needles-32g-4mm-100-box\"\u003e32G pen needles\u003c\/a\u003e and \u003ca href=\"\/en-us\/products\/sharps-container-1-quart-20-case\"\u003e1-quart sharps container\u003c\/a\u003e carry the same documentation pattern, and volume requirements run through the \u003ca href=\"\/en-us\/pages\/wholesale\"\u003ewholesale enquiry desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eInsulin syringe 1 cc × 31G × 5\/16 inch: specification and verification\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eAs listed on this page\u003c\/th\u003e\n\u003cth\u003eWhat to verify on the record\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarrel\u003c\/td\u003e\n\u003ctd\u003e1 mL with fine graduations\u003c\/td\u003e\n\u003ctd\u003eScale is U-100 (100 units per mL) and matches the vial in use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeedle gauge\u003c\/td\u003e\n\u003ctd\u003e31G\u003c\/td\u003e\n\u003ctd\u003e0.25 mm nominal outside diameter to ISO 9626:2016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeedle length\u003c\/td\u003e\n\u003ctd\u003e5\/16 inch (7.94 mm)\u003c\/td\u003e\n\u003ctd\u003eMeasured length and label agree with the requisition code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeedle attachment\u003c\/td\u003e\n\u003ctd\u003eFixed needle, single use\u003c\/td\u003e\n\u003ctd\u003eHub drawing, and no separate needle to attach\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct standard\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eDeclaration citing ISO 8537:2016; not ISO 7886-1 alone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterilisation\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eISO 11135:2014 for ethylene oxide, or the ISO 11137 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterile barrier\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eISO 11607-1:2019 qualification, with shelf life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual volume\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eMeasured hub and needle dead space, in mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality system\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eISO 13485:2016 certificate held by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003ctd\u003eCliniEco Medical, MDEL #35334\u003c\/td\u003e\n\u003ctd\u003eLicence number recorded on the supplier file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCliniEco Medical distributes injection consumables in Canada under MDEL #35334. This section is a specification reference for organisations building an insulin supply list; device and dose decisions stay with the treating team.\u003c\/p\u003e\n\u003ch2\u003eRelated reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/diabetes-management-supplies-canadian-patients-glucometers-test-strips\"\u003eDiabetes management supplies: glucometers, strips and lancets\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/medical-device-licensing-in-canada-class-i-vs-class-ii-vs-class-iv-explained\"\u003eMedical device classes in Canada explained\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/diabetes-education-clinic-supplies-foot-exam-and-injection-stock\"\u003eDiabetes education clinic supplies\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eListing note:\u003c\/em\u003e this page is published ahead of full catalogue onboarding so that specifications, documentation and sourcing details are available in one place. Pricing and ordering will be enabled once supplier documentation is complete. To be notified or to discuss volume requirements, use our \u003ca href=\"\/en-us\/pages\/wholesale\"\u003eB2B enquiry form\u003c\/a\u003e.\u003c\/p\u003e\n","brand":"CliniEco Medical","offers":[{"title":"2-Pack","offer_id":49081998999774,"sku":"CLI-INSSYR-100-2PK","price":69.98,"currency_code":"CAD","in_stock":true},{"title":"Single","offer_id":49039190032606,"sku":"CLI-INSSYR-100","price":34.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/insulin-syringes-1cc-31g-100-box-1.jpg?v=1789404341"},{"product_id":"sterile-blood-lancets-33g-100-box","title":"Sterile Blood Lancets 33G — 100\/Box","description":"\u003cp\u003eSterile single-use lancets with a 33 gauge point, supplied 100 per box, for capillary blood sampling in glucose monitoring and point-of-care testing. Each lancet is used once and disposed of in a sharps container.\u003c\/p\u003e\n\u003cp\u003eGauge and depth both affect sampling: a thinner lancet is usually less painful but needs good capillary flow, so clinics with cold-hand or low-perfusion patients often keep a second size on hand.\u003c\/p\u003e\n\u003ch2\u003eWho it is for\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDiabetes education and monitoring clinics\u003c\/li\u003e\n\u003cli\u003eFamily practices running point-of-care glucose tests\u003c\/li\u003e\n\u003cli\u003eLong-term care homes and retirement residences\u003c\/li\u003e\n\u003cli\u003ePharmacies offering screening services\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSterile, single use, 100 per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntended use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCapillary blood sampling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecification listing — availability pending supplier documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhat lancet gauge should a clinic stock?\u003c\/h3\u003e\n\u003cp\u003eMost clinics stock one mid-range gauge for routine use plus a smaller gauge for patients with reduced perfusion or when comfort is the priority. 33G sits at the fine end.\u003c\/p\u003e\n\u003ch3\u003eAre lancets reusable?\u003c\/h3\u003e\n\u003cp\u003eNo. Lancets are single use for both infection control and skin-trauma reasons, and each one goes straight into a sharps container.\u003c\/p\u003e\n\u003ch3\u003eDo lancets need to be disposed of as sharps?\u003c\/h3\u003e\n\u003cp\u003eYes. Lancets are a sharps stream even when the point is retracted into a housing, because the housing can be breached in waste handling.\u003c\/p\u003e\n\u003ch3\u003eHow do I ask about volume supply?\u003c\/h3\u003e\n\u003cp\u003eUse our B2B enquiry form and we will confirm documentation status and availability.\u003c\/p\u003e\n\u003ch2\u003eWhat does 33G mean on a blood lancet?\u003c\/h2\u003e\n\u003cp\u003eGauge describes the outside diameter of the point, not how deep it cuts. In the ISO 9626:2016 needle tubing series, 33G is the 0.20 mm designated size: one step finer than 32G at 0.23 mm, and the second-finest size in a series that stops at 34G (0.18 mm). A finer point parts less tissue, which is why fine gauges are associated with less discomfort at the puncture. Gauge alone does not set the sample, though, because the incision depth comes from the lancing device that holds and drives the lancet. A 33G lancet in a device set shallow can produce a smaller drop than a 30G lancet at a deeper setting, so clinics pair a fine gauge with an adjustable device instead of assuming that the finest lancet is the kindest one for every patient.\u003c\/p\u003e\n\u003ch2\u003eWhy is a multi-patient lancing device not acceptable, even with a new lancet?\u003c\/h2\u003e\n\u003cp\u003eHealth Canada addressed this directly in its notice of 26 September 2014 on licensing requirements for lancing devices and blood glucose monitoring systems (file 14-111696-560). The notice states that multi-patient use of lancing devices has been documented to pose a risk of disease transmission even if a new lancet is used for every patient. It also states that Health Canada will license lancing devices only if they are labelled as auto-disabling or for single-patient use, that point-of-care meters intended for multiple patients are licensed only with auto-disabling single-use lancing devices, and that the meter labelling must instruct health care personnel to change gloves between patients. The same notice records a 2012 Canadian incident in which a device designed for one person was used to obtain blood samples from 72 staff and students. A single-use lancet is therefore half of the control; the holder is the other half.\u003c\/p\u003e\n\u003ch2\u003eWhich documents belong in a lancet specification file?\u003c\/h2\u003e\n\u003cp\u003eSterility comes first: sterilisation validated to ISO 11135:2014 for ethylene oxide or to the ISO 11137 series for radiation, to a sterility assurance level of 10\u003csup\u003e−6\u003c\/sup\u003e, with the sterile barrier system qualified to ISO 11607-1:2019 and a stated shelf life. Biological safety is assessed under ISO 10993-1:2018, and the manufacturer's quality system should hold ISO 13485:2016 certification. In Canada the device licence belongs to the manufacturer, while the importer or distributor holds a Medical Device Establishment Licence; CliniEco Medical distributes under MDEL #35334. For the glucose side of the workflow, Health Canada recognised ISO 15197:2013 for blood glucose monitoring systems for self-testing in the same 2014 notice, with a one-year transition for new devices. Marks belong to jurisdictions too: a CE mark is the manufacturer's declaration of conformity for the European market and is not evidence of Canadian licensing, so a Canadian file still needs the licence reference and the establishment licence number beside it. A specification file that holds those documents answers most of a procurement review before it starts.\u003c\/p\u003e\n\u003ch2\u003eHow should used lancets be handled in a Canadian clinic?\u003c\/h2\u003e\n\u003cp\u003eA lancet is single use and goes into a sharps container at the point of use, point first, without recapping by hand. Waste rules are provincial rather than federal. In Ontario, guideline C-4, The Management of Biomedical Waste in Ontario, lists human blood waste in Table A with a yellow label and the universal biohazard symbol, and sharps go into a puncture-resistant, closeable container. A clinic in another province has to name its own rule instead of copying the Ontario one, and a policy written for sites in several provinces should cite the jurisdiction beside each requirement. Add the audit trail: container fill level, replacement date, and the person who closed and labelled it.\u003c\/p\u003e\n\u003ch2\u003eWhat should be checked when a box of lancets arrives?\u003c\/h2\u003e\n\u003cp\u003eCheck the label against the requisition for gauge, box count and single-use wording; check that the sterile barrier is intact and the expiry date has not passed; confirm the carton has been stored dry and away from heat; and record the lot number on the receiving record so a supplier notice can be traced to a drawer. Keep one opened sample with the training file if the clinic trains new staff on lancing technique. Our \u003ca href=\"\/en-us\/products\/clinieco-blood-glucose-monitor-kit-complete-diabetes-testing-kit-with-50-test-strips\"\u003eblood glucose monitor kit\u003c\/a\u003e, \u003ca href=\"\/en-us\/products\/insulin-syringes-1cc-31g-100-box\"\u003e1 cc insulin syringes\u003c\/a\u003e and \u003ca href=\"\/en-us\/products\/sharps-container-1-quart-20-case\"\u003e1-quart sharps container\u003c\/a\u003e are documented the same way, and volume requirements run through the \u003ca href=\"\/en-us\/pages\/wholesale\"\u003ewholesale enquiry desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003e33G blood lancet: what each specification changes\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eAs listed on this page\u003c\/th\u003e\n\u003cth\u003eWhat it changes at the bedside\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003e33G, 0.20 mm nominal outside diameter in the ISO 9626:2016 series\u003c\/td\u003e\n\u003ctd\u003eTissue trauma and discomfort at the puncture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCutting depth\u003c\/td\u003e\n\u003ctd\u003eSet by the lancing device, not by the lancet\u003c\/td\u003e\n\u003ctd\u003eDrop size, and whether a second puncture is needed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eSterile, single use, 100 per box\u003c\/td\u003e\n\u003ctd\u003eOne lancet per patient, then straight into sharps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice labelling\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eAuto-disabling or single-patient use, per Health Canada's 2014 notice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterilisation\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eISO 11135:2014 or the ISO 11137 series, sterility assurance level 10\u003csup\u003e−6\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterile barrier\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eISO 11607-1:2019 qualification and stated shelf life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBiocompatibility\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eISO 10993-1:2018 evaluation for skin contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality system\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eISO 13485:2016 certificate held by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003ctd\u003eCliniEco Medical, MDEL #35334\u003c\/td\u003e\n\u003ctd\u003eLicence number recorded on the supplier file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCliniEco Medical supplies blood sampling consumables to Canadian clinics under MDEL #35334. This section is a specification reference; lancet and lancing device selection remains a clinical decision.\u003c\/p\u003e\n\u003ch2\u003eRelated reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/diabetes-management-supplies-canadian-patients-glucometers-test-strips\"\u003eDiabetes management supplies: glucometers, strips and lancets\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/sharps-containers-in-canada-types-regulations-and-sizes-explained\"\u003eSharps containers in Canada: types and sizes\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/blood-glucose-monitor-procurement-for-canadian-clinics-testing-kits-and-compliance\"\u003eBlood glucose monitor procurement for Canadian clinics\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eListing note:\u003c\/em\u003e this page is published ahead of full catalogue onboarding so that specifications, documentation and sourcing details are available in one place. Pricing and ordering will be enabled once supplier documentation is complete. To be notified or to discuss volume requirements, use our \u003ca href=\"\/en-us\/pages\/wholesale\"\u003eB2B enquiry form\u003c\/a\u003e.\u003c\/p\u003e\n","brand":"CliniEco Medical","offers":[{"title":"4-Pack","offer_id":49081999392990,"sku":"CLI-LANCET-100-4PK","price":59.96,"currency_code":"CAD","in_stock":true},{"title":"Single","offer_id":49039190720734,"sku":"CLI-LANCET-100","price":14.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/sterile-blood-lancets-33g-100-box-1.jpg?v=1789404344"},{"product_id":"insulin-pen-needles-32g-4mm-100-box","title":"Insulin Pen Needles 32G × 4 mm — 100\/Box","description":"\u003cp\u003eInsulin pen needles measuring 32G with a 4 mm length, supplied 100 per box. 4 mm is the shortest commonly used pen needle length and is appropriate for most adults regardless of body size, provided injection technique lifts the skin appropriately.\u003c\/p\u003e\n\u003cp\u003eThis page documents the specification for organisations that standardise pen needles as part of an insulin supply list — clinics, care homes and diabetes education programs.\u003c\/p\u003e\n\u003ch2\u003eWhat does 32G × 4 mm actually specify?\u003c\/h2\u003e\n\u003cp\u003eGauge describes the outside diameter of the cannula, not its bore. 32G sits at 0.23 mm nominal outside diameter in the ISO 9626:2016 gauge series, which runs from 0.18 mm (34G) to 3.4 mm (10G). Wall thickness decides the inner diameter, so two needles both marked 32G can differ in flow and in the force needed to deliver a dose; thin-wall and extra-thin-wall variants are not the same product. Length is measured from the hub shoulder to the tip, and 4 mm is the short end of the adult range. Four millimetres reaches subcutaneous fat in most adults, including adults with a higher body mass index, which is why guidance moved away from 8 mm and 12 mm as default lengths. It is not universal: very young children, very lean adults and anyone injecting into a lifted skin fold need a clinical decision, and the injection technique (straight in at 90 degrees with or without a lift) belongs in the written protocol next to the product code.\u003c\/p\u003e\n\u003ch2\u003eWhich standard should the supplier's test report cite?\u003c\/h2\u003e\n\u003cp\u003eDouble-ended pen needles are covered by ISO 11608-2:2022, third edition, which refers to ISO 11608-1 for dose accuracy and functional compatibility and adapts the needle requirements of ISO 7864:2016; the tubing dimensions come from ISO 9626:2016. Sterility and the sterile barrier are separate questions: ask whether the process is validated to ISO 11135:2014 for ethylene oxide or to the ISO 11137 series for radiation, and whether the packaging system is qualified to ISO 11607-1:2019. A manufacturer working to ISO 13485:2016 can produce those reports on request. Distributors in Canada hold a Medical Device Establishment Licence; CliniEco Medical operates under MDEL #35334. A specification sheet that cites the standard and the edition answers most of a procurement review before it starts.\u003c\/p\u003e\n\u003ch2\u003eHow much insulin is left in the needle, and why does priming matter?\u003c\/h2\u003e\n\u003cp\u003eEvery pen needle has dead space between the cartridge septum and the needle tip. The manufacturer's priming step, commonly two units, fills that space so the dose dialled is the dose delivered. Skipping the prime under-delivers the first dose from a new needle; priming more than the instruction wastes insulin across a box of 100 and, in a facility, across a year. Write the priming volume into the protocol beside the product code, because it depends on the pen and needle combination rather than on the patient. Dose accuracy itself is what ISO 11608-1 is testing, and it is measured on the complete system, not on the needle alone.\u003c\/p\u003e\n\u003ch2\u003eWhat belongs in a care-home or clinic pen-needle standard?\u003c\/h2\u003e\n\u003cp\u003eOne gauge and length per pen model; compatibility verified against the pen manufacturer's own instructions rather than a generic fits-most-pens claim; single use with no recapping by hand; a sharps container within reach at every injection point; and a documented needlestick procedure. In Ontario, used needles are biomedical waste and are segregated into puncture-resistant sharps containers under Guideline C-4, The Management of Biomedical Waste in Ontario, which is the provincial document for that jurisdiction. Other provinces publish their own rules, so a policy written for sites in more than one province has to name the jurisdiction rather than treat the rule as national. Add the paper trail: lot number recorded at receipt, storage away from heat and light, and a par level that covers each pen station.\u003c\/p\u003e\n\u003ch2\u003eWhat should a buyer compare between two 32G × 4 mm boxes?\u003c\/h2\u003e\n\u003cp\u003eFive things change clinical performance, and two boxes with identical gauge and length can differ on all five: nominal outside diameter together with wall type, the pen models the hub has been validated for, the sterilisation method, the shelf life claimed for the sterile barrier, and the documentation package. Sourcing at volume is where those differences disappear into a spreadsheet, so keep a specification sheet per product code and attach the supplier's declaration to it. Our \u003ca href=\"\/en-us\/products\/clinieco-blood-glucose-monitor-kit-complete-diabetes-testing-kit-with-50-test-strips\"\u003eblood glucose monitoring kit\u003c\/a\u003e and \u003ca href=\"\/en-us\/products\/sterile-blood-lancets-33g-100-box\"\u003e33G blood lancets\u003c\/a\u003e follow the same documentation approach for the rest of a diabetes supply list, and the \u003ca href=\"\/en-us\/products\/sharps-container-1-quart-20-case\"\u003e1-quart sharps container\u003c\/a\u003e closes the disposal loop. Volume requirements are handled through the \u003ca href=\"\/en-us\/pages\/wholesale\"\u003ewholesale enquiry desk\u003c\/a\u003e.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ccaption\u003eInsulin pen needle 32G × 4 mm: specification and verification\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eAs listed on this page\u003c\/th\u003e\n\u003cth\u003eWhat to verify on the batch record\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003e32G, 0.23 mm nominal outside diameter under ISO 9626:2016\u003c\/td\u003e\n\u003ctd\u003eLot certificate stating the tube dimension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e4 mm\u003c\/td\u003e\n\u003ctd\u003eLabel and hub drawing agree with the requisition code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eRegular, thin or extra-thin wall, and the flow this gives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHub compatibility\u003c\/td\u003e\n\u003ctd\u003eStandard insulin pen platforms, verified per pen model\u003c\/td\u003e\n\u003ctd\u003eList of pen models the manufacturer tested\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDose accuracy basis\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eTest report citing ISO 11608-1 and ISO 11608-2:2022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterilisation\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003eISO 11135:2014 for ethylene oxide, or the ISO 11137 series for radiation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterile barrier\u003c\/td\u003e\n\u003ctd\u003eNot stated on this page\u003c\/td\u003e\n\u003ctd\u003ePackaging qualified to ISO 11607-1:2019, with shelf life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality system\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eISO 13485:2016 certificate held by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistribution\u003c\/td\u003e\n\u003ctd\u003eCliniEco Medical, MDEL #35334\u003c\/td\u003e\n\u003ctd\u003eLicence number on the supplier record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCliniEco Medical distributes diabetes and injection consumables in Canada under MDEL #35334. This page is a specification reference for organisations building an insulin supply list.\u003c\/p\u003e\n\u003ch2\u003eWho it is for\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLong-term care homes standardising insulin pen supplies\u003c\/li\u003e\n\u003cli\u003eDiabetes education programs and outpatient clinics\u003c\/li\u003e\n\u003cli\u003eCommunity pharmacies with injection support services\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 per box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard insulin pen platforms (verify per pen model)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecification listing — availability pending supplier documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhy do pen needle lengths come in 4, 5, 6, 8 and 12 mm?\u003c\/h3\u003e\n\u003cp\u003eLength is chosen to reach subcutaneous tissue reliably without reaching muscle. Short 4 mm needles have largely replaced longer lengths for adults because they reduce the risk of intramuscular injection.\u003c\/p\u003e\n\u003ch3\u003eShould a pen needle be reused?\u003c\/h3\u003e\n\u003cp\u003eNo. Reusing a pen needle blunts the point, increases pain and can affect dose delivery. Facilities usually issue needles per injection and drop each one into a sharps container.\u003c\/p\u003e\n\u003ch3\u003eDo pen needles fit every insulin pen?\u003c\/h3\u003e\n\u003cp\u003ePen needle platforms differ. Verify compatibility against the specific pen model you stock before setting a standard.\u003c\/p\u003e\n\u003ch3\u003eHow do I ask about volume supply?\u003c\/h3\u003e\n\u003cp\u003eSend your requirement through our B2B enquiry form.\u003c\/p\u003e\n\u003ch2\u003eRelated reading\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/diabetes-management-supplies-canadian-patients-glucometers-test-strips\"\u003eDiabetes management supplies: glucometers, strips and lancets\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/medical-device-licensing-in-canada-class-i-vs-class-ii-vs-class-iv-explained\"\u003eMedical device classes in Canada explained\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en-us\/blogs\/medical-supply-guide\/university-teaching-lab-supplies-ppe-and-specimen-essentials\"\u003eClinic and teaching program supply essentials\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eListing note:\u003c\/em\u003e this page is published ahead of full catalogue onboarding so that specifications, documentation and sourcing details are available in one place. Pricing and ordering will be enabled once supplier documentation is complete. To be notified or to discuss volume requirements, use our \u003ca href=\"\/en-us\/pages\/wholesale\"\u003eB2B enquiry form\u003c\/a\u003e.\u003c\/p\u003e\n","brand":"CliniEco Medical","offers":[{"title":"2-Pack","offer_id":49082000212190,"sku":"CLI-PENN-100-2PK","price":53.98,"currency_code":"CAD","in_stock":true},{"title":"Single","offer_id":49039191048414,"sku":"CLI-PENN-100","price":26.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0797\/5741\/0526\/files\/insulin-pen-needles-32g-4mm-100-box-1.jpg?v=1789404348"}],"url":"https:\/\/clinieco.ca\/en-us\/collections\/diabetes-care.oembed","provider":"CliniEco Medical","version":"1.0","type":"link"}